SUNSHINE II is a 1988 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 1996, most recently in June 2026, along with 38 deficiencies and 1 casualty investigation in 2013.

Records from 1996 to 2026. Most recent: inspection, 25 June 2026.

Built
1988
Last inspected
25 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4072
321081
Flag
UNITED STATES
367532660
Maury page id
psix-321081

Inspections, by type

…with no type recorded1
Years with a record 25 calendar years (1996–2026)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)39.4 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOFFSHORE CATAMARANS INC · STUART, FL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Faired Keel)
Hull configurationTwin Hull
Hailing portCHARLEVOIX, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP8035MMSI 367532660 · active · compulsorily equipped · granted 11 September 2024, expires 11 September 2034
WDG4072MMSI 367532660 · expired · compulsorily equipped · granted 30 May 2012, cancelled 30 July 2022
WCY5508MMSI 367368560 · expired · compulsorily equipped · granted 16 July 2008, cancelled 15 September 2018 · licensed under a name not among this hull’s recorded names (not shown)
WCW2432MMSI not assigned · expired · compulsorily equipped · granted 1 March 1996, cancelled 6 May 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 41

25 June 2026 COI Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8395487
3 September 2025 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8227533
9 October 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8034034
11 September 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7790211
20 October 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7587928
8 September 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7568003
28 April 2022 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7458761
23 August 2021 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7272615
10 September 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6809463
7 June 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6713553
12 September 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6540371
11 September 2017 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6267452
22 November 2016 Hull Examination · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6130585
18 September 2016 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6007872
1 September 2016 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5988807
9 September 2015 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5723608
9 October 2014 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5002276
14 August 2014 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4954860
17 June 2012 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4346194
14 June 2012 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4346188
11 May 2012 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4308622
16 July 2009 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3542546
16 May 2008 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3212182
31 May 2007 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2954094
25 May 2006 Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2667063
4 June 2004 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2087520
7 May 2004 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2059111
6 June 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1812945
23 July 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1362367
28 June 2000 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1423409
16 June 1999 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 881287
3 May 1999 Hull Examination · Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1096759
3 May 1999 Hull Examination · COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1378705
29 June 1998 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1444092
22 June 1998 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 792173
28 April 1998 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1124008
16 April 1998 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 788725
16 March 1998 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1113668
24 April 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1102035
22 April 1997 Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1394718
22 March 1996 Initial Certification · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1390234

Deficiency record · 38

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2022 Resolved
1 adult PFD & 1 child PFD rejected due to UV damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 8 September 2022
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 August 2021 Resolved
Port sponson bilge alarm inop. Must be repaired/replaced & proper operation demonstrated to CG Marine Inspector. Vessel crew must check port sponson bilges every 15 minutes while underway or when passengers are aboard until properly repaired & demonstrated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 9 September 2021
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 August 2021 Resolved
Emergency fuel shut-offs need to be properly marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 9 September 2021
Resolution: marked.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 September 2019 Resolved
Vessel needs current COD onboard. 46 CFR 67.7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 13 September 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 September 2019 Resolved
Replace expired flares. 46 CFR 180.68
Action required: 10 - Deficiency Rectified
Due 10 September 2019
Resolved 11 September 2019
Resolution: Replaced expired flares.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 September 2018 Resolved
Ring buoy must be marked in clearly legible block capital letters with the vessel's name. Ring buoy must be properly marked prior to carrying passengers and prior to next operating season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2019
Resolved 7 June 2019
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2018 Resolved
Each accommodation space must have a 2-A portable fire extinguisher or larger. Provide 2-A portable fire extinguisher or larger for each accommodation space prior to carrying passengers and prior to next operating season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2019
Resolved 7 June 2019
Resolution: provided & properly mounted.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 12 September 2018 Resolved
Each vessel carrying more than 6 passengers for hire equipped with a radio must have onboard a marine radio operators permit. Obtain a marine radio operators permit prior to carrying passengers and prior to next operating season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2019
Resolved 7 June 2019
Resolution: Obtained permit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 September 2018 Resolved
A power driven vessel underway must exhibit a masthead light. Masthead light is inoperable. Prove operable masthead light by 12 October 2018. Vessel is limited to day time operations until discrepancy is corrected.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2018
Resolved 7 June 2019
Resolution: Corrected.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 1 September 2016 Resolved
Mark vessel name in visible location on stern.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 18 September 2016
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 1 September 2016 Resolved
Replace plastic trash cans with noncombustible receptacles.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 18 September 2016
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 1 September 2016 Resolved
Provide overcurrent protective devices for feeder wires powering breaker panels.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 18 September 2016
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 1 September 2016 Resolved
Provide current copy of Navigation Rules.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 18 September 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 September 2015 Resolved
Demonstrate proper operation of port bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 20 September 2015
Resolution: Demonstrated proper operation.
Engineering › Bilge Water Management System › Interface Detector
Issued 20 August 2014 Resolved
Install high level bilge alarm in port hull and demonstrate satisfactory operation to an attending USCG Inspector prior to 08 October when vessel is in Mackinaw City.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 October 2014
Resolved 9 October 2014
Resolution: Verified as resolved this date
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 11 May 2012 Resolved
Man-overboard recovery methods unsafe. Deckhand needed to have lifeline/tether for man-overboard recovery. Corrected during inspection.
Due 25 May 2012
Resolved 25 May 2012
Resolution: corrected during inspection.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 May 2012 Resolved
Provide FCC Operators permit per 467 CFR 80.
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 14 June 2012
Resolution: Provided copy of FCC Operators Permit.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 May 2012 Resolved
Provide Great Lakes Agreement radio inspection certificate as per 47 CFR 80..
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 14 June 2012
Resolution: Provided copy of Great Lakes radio inspection.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 May 2012 Resolved
First attempt at MOB recovery drill failed, unsafe. Deckhand not tethered, not wearing PFD while outside lifelines/railing. Coached improvement. Second MOB drill was satisfactory.
Due 25 May 2012
Resolved 25 May 2012
Resolution: corrected during inspection
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 May 2012 Resolved
Mark location of adult size life preservers where stowed next to P/S keel daggers.
Due 25 May 2012
Resolved 25 May 2012
Resolution: corrected during inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2012 Resolved
Replace missing and expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Due 25 May 2012
Resolved 25 May 2012
Resolution: Corrected during inspection
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 25 May 2006 Resolved
Replace worn/torn PFD.
Condition: Unknown
Due 5 June 2006
Resolved 5 June 2006
Lifesaving
Issued 23 July 2001 Resolved
Install retro-reflective tape on lifering prior to the compliance date.
Condition: Unknown
Due 31 July 2001
Resolved 6 August 2001
Lifesaving
Issued 3 May 1999 Resolved
LABEL 6 ADULT LIFEJACKETS PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Lifesaving
Issued 3 May 1999 Resolved
PROVIDE 18 FOOT LANYARD FOR SURVIVAL CRAFT WATERLIGHT PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Documentation
Issued 3 May 1999 Resolved
PROVIDE LOGBOOK TO DOCUMENT REQUIRED DRILLS, TRAINING AND EQUIPMENT INSPECTIONS PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Documentation
Issued 16 March 1998 Resolved
PROVIDE PROOF OF CURRENT DOCUMENTATION.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Fire Fighting
Issued 16 March 1998 Resolved
RECHARGE ONE B-II FIRE EXTINGUISHER PRIOR TO SAILING.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Documentation
Issued 16 March 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Navigation
Issued 16 March 1998 Resolved
CLEAN HYDRAULIC FLUID FROM STBD STEERING COMPARTMENT.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Navigation
Issued 16 March 1998 Resolved
SECURE PORT RUNNING LIGHT PRIOR TO SAILING.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Navigation
Issued 16 March 1998 Resolved
REPLACE STBD RUNNING LIGHT PRIOR TO SAILING.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Accommodation/Occupational Safety
Issued 16 March 1998 Resolved
WELD BASE OF LIFE RAIL STANCHION ON PORT SIDE.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Lifesaving
Issued 16 March 1998 Resolved
REPLACE LIFERING AND ITS LINE WITH AT LEAST 60 FEET OF UV RESISTANT FLOTATION LINE PRIOR TO SAILING.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Lifesaving
Issued 16 March 1998 Resolved
PROVIDE PRIMARY LIFESAVING EQUIPMENT FOR AT LEAST 18 PERSONS FOR NEW GREAT LAKES OPERATING AREA.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Accommodation/Occupational Safety
Issued 22 April 1997 Resolved
Renew engine cover (deck) prior to carrying passengers.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Fire Fighting
Issued 22 April 1997 Resolved
Service or renew one B1 and two BII fire extinguishers in accordance with Federal Register Vol.61, No.7 176.810. To be completed prior to carrying passengers.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 22 April 1997 Resolved
Mark emergency exits on weather deck in accordance with Federal Register Vol.61, No.7 185.606.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997

Casualty record · 1

23 August 2013Routine · role: Involved in a Marine Casualty · at CHARLEVOIX DRAW BRIDGE · activity 4699934
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.