Documentation record
Registered dimensions (L × B × D)64.8 ft × 18.5 ft × 8.0 ft
Registered tonnagegross 64 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLITTLE HOQUIAM BOAT SHOP · HOQUIAM, WA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, fi, rec, reg
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Simplified, Gross Ton
51 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 18 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
20 January 2026
Annual Inspection · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299452
4 November 2025
Internal Structural Exam · Drydock Exam · Vessel Attendance · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8264318
6 February 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8076005
5 March 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7875038
23 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7858057
27 February 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7642895
15 March 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7408640
17 February 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7398208
18 April 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7177809
18 April 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7177870
1 February 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134374
4 March 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6920121
18 February 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6911214
27 February 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6630116
7 March 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6368666
21 February 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6357993
9 March 2017
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6096589
9 March 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5973442
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2026
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used.
Vessel has dead end wires in the FWD void. Vessel to remove dead end wires or install suitable junction box for the connections.
46 CFR 183.10-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2026
Resolved 19 February 2026
Resolution: Dead end waring properly terminated/boxed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 February 2025
Resolved
certification and reinspection the inspector shall examine and test... navigation lights... which are required. Vessel's stern light was inoperable at the time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2025
Resolved 12 February 2025
Resolution: Stern light repaired.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 6 February 2025
Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date charts. The electronic charts the vessel is using are not being updated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2025
Resolved 12 February 2025
Resolution: Electronic charts received updates and are now current.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 February 2025
Resolved
Shutoff valves... shall be fitted in the fuel supply lines... to stop fuel. The shutoff valve at the tank shall be operable from outside the tank compartment. The STBD Aft Fuel Shutoff valve would not operate when actuated from outside the space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2025
Resolved 19 February 2025
Resolution: Operator completed repair to the STBD AFT S/O valve. Functions as intended.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 February 2023
Resolved
Vessel required to carry 6 orange smoke and 6 red flare visual distress signals. Only 5 red flares onboard at the time of inspection. Provide one additional red flare.
Action required: 10 - Deficiency Rectified
Due 27 February 2023
Resolved 27 February 2023
Resolution: Additional red flare was provided prior to the completion of the inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 March 2022
Resolved
EAP information not posted. Post EAP information.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 15 March 2022
Resolution: EAP information posted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 March 2022
Resolved
Stern light not functioning. Repair stern light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 15 March 2022
Resolution: Light replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 April 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. While underway, with passengers, the vessel reported a loss of electrical power to the main engine. Vessel to determine root cause of failure and make permanent repairs prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2021
Resolved 22 April 2021
Resolution: A new voltage converter was installed and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2020
Resolved
Life ring plug missing. ring no longer serviceable. Replace ring. 46CFR180.70(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2020
Resolved 7 March 2020
Resolution: Ring replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 March 2020
Resolved
Weekly, quarterly, and annual inspection of life saving equipment is not being logged or otherwise documented. Provide proper records for required safety equipment inspections. 46CFR185.702(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2020
Resolved 7 March 2020
Resolution: Logs provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 March 2020
Resolved
Vessel not equipped with Cat. 1, 406 mhz, EPIRB yet certificated for and operating on a LBS plus LC route. Cat. 1, 406 mhz, EPIRB is required to operate more than 3nm from the baseline(shore). Provide Cat. 1, 406 mhz, EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2020
Resolution: Properly registered EPIRB provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 February 2019
Resolved
PROVIDE A COMPANY CORRECTIVE ACTION PLAN TO ENSURE COMPLIANCE WITH RECORDS AND LOGS, DRILLS TRAINING AND EMERGENCY. EQUIPMENT MAINTENANCE LOGS WERE NOT ON BOARD AT THE TIME OF INSPECTION.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 25 March 2019
Resolution: POC provided evidence of current maintenance and training logs via photos
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 February 2019
Resolved
PROVIDE UPDATED AND CORRECTED CHARTS
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 25 March 2019
Resolution: POC provided evidence of updated and corrected charts on board vessel
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 February 2019
Resolved
BULWARK ON PORT QUARTER IS SEPARATED FROM STANCHION
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 15 March 2019
Resolution: POC provided photo of repairs
Navigation › Piloting/Steering › Magnetic Compass
Issued 9 March 2017
Resolved
Magnetic compass light is inoperable. Replace necessary parts to restore illumination function.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 7 April 2017
Resolution: Recieved photograph of illuminated magnetic compass.
Documentation › Certificates/Documents › FCC SSL
Issued 9 March 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 7 April 2017
Resolution: Renewed certificate.
Engineering › Bilge Water Management System › Pump
Issued 9 March 2017
Resolved
Bilge pump located in lazarette inoperable. Replace bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 7 April 2017
Resolution: Recieved photograph of new pump.
Engineering › Fuel Oil Service System › Hose
Issued 9 March 2017
Resolved
Return fuel oil hose on generator not listed on SAE J-1942-1; not fire rated. Replace with approved hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 7 April 2017
Resolution: Recieved photograph of new compliant hose.