Records from 1988 to 2002. Most recent: inspection, 18 November 2002.
Inspection history · 22
18 November 2002
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1708533
16 July 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 292162
26 April 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 278201
7 April 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 427101
22 April 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 415264
2 January 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 163473
26 April 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 474796
26 April 1997
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1100286
26 May 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 391803
16 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 379664
17 March 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 704094
16 March 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 60554
16 March 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 507484
30 March 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 365684
30 March 1994
Tank Vessel Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359764
30 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 357312
30 March 1993
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428193
13 September 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 339391
13 September 1990
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232061
31 October 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 333604
31 October 1989
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1316490
8 December 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 327309
Lifesaving
Issued 7 April 1999
Resolved
_x001C_ FREEZER SPACE ALARM INOP
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Deck/Cargo
Issued 30 March 1993
Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM BLOWER SHUTDOWN FOR LOSS OF NORMAL WATER SUPPLY TO THE DECK WATER SEAL, IAW 46 CFR 32.53-70(b)(3).
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Deck/Cargo
Issued 30 March 1993
Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM BLOWER SHUTDOWN WHEN INERT GAS BEING DELIVERED TO THE CARGO TANKS IS MORE THAN 65.5 DEGREES C. OR 150 DEGREES F., IAW 46 CFR 32.53-70(b)(4).
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993