Records from 1988 to 2025. Most recent: inspection, 24 November 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 89
24 November 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8273155
4 November 2025
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8253423
3 March 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8081489
26 December 2024
Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8050969
21 March 2024
Internal Structural Exam · Drydock Exam · Deficiency Check · Drydock Extension
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7885052
8 March 2024
Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7946569
4 March 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7873828
27 February 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7641323
20 May 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7454807
11 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7409589
4 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7406112
13 August 2021
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7285456
23 December 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7119545
3 December 2020
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7100362
17 July 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7007049
22 May 2020
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6928670
16 January 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6890741
3 January 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6872904
26 February 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6631706
14 February 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6614472
25 January 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6614983
15 March 2018
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6373260
14 December 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6323585
22 March 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6109400
20 January 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6074081
3 January 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6064847
21 December 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6053522
24 February 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5818095
30 December 2015
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5795480
30 November 2015
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5764724
18 March 2014
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4818216
31 January 2012
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4235378
10 January 2012
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4223165
10 January 2012
DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 4224150
2 December 2011
Simplified Stability Test
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4182423
6 December 2010
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3912646
2 December 2010
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3879209
24 March 2010
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3701963
1 March 2010
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3687765
3 February 2010
DAPI Audit · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3675496
28 January 2009
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3401634
14 January 2009
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3374871
20 March 2008
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3162973
20 November 2007
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3098249
16 April 2007
Type not recorded
No type recorded · USCG East District (dp) · USCG East District (CGD-E) · Activity 2908986
29 January 2007
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2863255
24 January 2007
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2861110
23 January 2007
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2860550
29 March 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2612200
21 March 2005
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2315690
23 February 2005
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2297886
22 March 2004
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2028944
8 March 2004
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1974950
14 February 2003
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1737417
20 March 2002
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1494492
17 December 2001
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1480934
2 July 2001
Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1387040
27 February 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1058569
29 January 2001
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1056768
7 March 2000
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1417025
27 January 2000
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1446869
31 March 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1120548
10 February 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 793532
30 November 1998
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1404653
16 March 1998
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1424551
1 December 1997
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1438666
2 May 1997
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1100075
26 January 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1095661
25 November 1996
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1357794
11 March 1996
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1442364
29 December 1995
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1185107
3 December 1995
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 876707
30 November 1995
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1405814
1 December 1994
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1456221
1 April 1994
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1450838
2 December 1993
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1401784
3 December 1992
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 963182
28 October 1992
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1249366
8 October 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 670844
7 October 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1250184
4 December 1991
Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 941549
18 April 1991
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1226158
9 April 1991
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 909198
19 March 1991
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1252854
18 April 1990
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1243081
13 April 1990
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1246147
28 April 1989
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1198411
10 February 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1040386
12 December 1988
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1346467
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2025
Resolved
All vessels shall be provided with bilge pumps. Vessel unable to get suction and pump overboard in the engine room and hold below the bar. 46CFR182.25-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2025
Resolution: MI witnessed suction and dewatering in both spaces.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2025
Resolved
Portable fire extinguishers shall be installed to OCMI satisfaction. Mounting brackets seized and difficult to remove portable fire extinguisher in emergency. Replaced mounting brackets to satisfaction of attending MI. 46CFR181.30-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Portable fire extinguishers brackets that would freeze shut were all replaced with quick release mounting brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 November 2025
Resolved
The name of the vessel and person capacity shall be clearly marked on each life float. Life floats were not marked that the MI's were able to verify. 46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Pax capacity and vessel name stenciled on 03 life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 November 2025
Resolved
Each life ring shall have tipe II retroflective tape. Retro worn and inneffective and requires replacement. 46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Life ring retroflective tape replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2025
Resolved
Fixed fire extinguishing systems shall be installed and maintained are are subject to hydrostatic testing at intervals of 12-years or less. MI unable to identify proof of hydrostatic test within 12-years. 46CFR181.20-1, NFPA 7.3.2.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: O/O provided proof of a full visual inspection within 5-years. This is permitted in [name withheld] 02-12. Requalification Identification Number (RIN) is V113056.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 November 2025
Resolved
Each lighting fixture must be of the fixed type. Several portable overhead lights plugged into an outlet identified in interior spaces. Remove or make permanently fixed to the satisfaction of attending MI. 46CFR183.410
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: O/O opted to remove all plug in lighting in the snack bar and waste holding tank spaces.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 November 2025
Resolved
Wiring joints and splices shall be mechanically secure and made in a junction box. Several junction boxes and outlets found open, cracked or not watertight. 46CFR183.05-50
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: All outlets and junction boxes replaced and closed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2025
Resolved
Visual and audible alarm required at operating station for high water level in unmanned spaces. #3 hold, engine room and lazerette spaces high water light at the operating station visually displayed high water in several compartments when one compartment was tested. 46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Verified all four spaces with high water alarms were audible and visual on the bridge.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 March 2025
Resolved
Each vessel that operates beyond 3-NM from the coastline shall have an EPIRB intalled to automatically float free. Hydrostatic release expired. Vessel restricted to within 3-NM from shore until replaced and attested to by MI. 46CFR180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 March 2025
Resolution: New HRU placed in service on vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 March 2025
Resolved
Any vessel of at least 5 net tons must have a certificate of documentation. Vessel's COD onboard expired. Provide proof of valid COD and retain copy onboard. 46CFR67.7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2025
Resolution: O/O produced current COD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 March 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears and rotating machinery. Rotating belt exposed on the generator in an an exposed area in the engine room. 46CFR177.35-15.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2025
Resolution: Aluminum guard placed over belt.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 March 2025
Resolved
Penetrations and opendings in watertight bulkheads must be kept as high and as far inboard as practicable and have a means to make them watertight. Watertight bulkead aft of the anchor chamber has an opening low and center in the bulkhead wall with cables running through it that is not watertight. Make bulkhead watertight and ready for further inspection by MI. 46CFR171.114
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2025
Resolution: O/O filled holes, bulkhead watertight.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2024
Resolved
A vessel must carry either a first aid kit approved
under approval series 160.041 or a kit with equivalent
content and instructions. Vessel did not have all
required equivalent contents of a first aid kit approved
under 160.041. Provide equivalent contents or a first
aid kit approved under 160.041.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 7 March 2024
Resolution: Owner provided vessel with additional First Aid kit supplies
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 4 March 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessels two 22 man life floats where found to be not in serviceable condition as evidenced by extensive UV deterioration and large openings exposing the foam flotation material. The exposed foam flotation material was found to be severely UV damaged and crumbling into pieces. Both life floats must be replaced by vessel owner. A temporary repair of life floats may be authorized by attending MI until both life floats are permanently replaced. Owner must send MI repair proposal for life floats for approval. Upon approval of temporary repair proposal, life floats must be visually examined by attending MI and satisfactorily float tested in the water in the presence of the attending MI. Vessel is restricted from operating less then 1NM from shore until life floats are replaced or temporary repair is satisfactory.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2024
Resolved 8 March 2024
Resolution: Owner temporarily repaired life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2024
Resolved
An adult life jacket must be provided for each person carried onboard. Vessel owner/operator provided 120 adult life jackets which does provide the proper amount for 121 adult passengers listed on the COI. Vessel owner must provide an additional life jacket or reduce passenger count to a total of 120 adult passengers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 8 March 2024
Resolution: Owner provided aditional PFD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2023
Resolved
Vessel's less than 65' carrying more than 49 passengers shall have a piping system and bilge pump capable of pumping 25 gallons per minute, and a portable hand pump for each space aft of the collision bulkhead. Vessel's bilge pump is not operational. 46CFR182.25-5; 46CFR182.25-10
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 1 March 2023
Resolution: Witness operational test of the bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in unmanned spaces. The visual alarm worked in space #3 aft of the kitchen, however, the audible alarm was inoperable. 46CFR182.530
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 1 March 2023
Resolution: Witnessed operational audible and visual alarm test of the #3 hold aft of the kitchen.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 February 2023
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Two pipe penetrations from the tank room to the engine room need to be made watertight, and two pipe penetrations from the engine room to the steering gear room need to be made watertight. 46CFR171.114
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 1 March 2023
Resolution: Watertight bulkhead penetrations made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 27 February 2023
Resolved
A vessel must be fitted with ground tackle appropriate for the vessel and waters on which it operates. Forward starboard cleat not properly secured to the vessel. 46CFR184.10-1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2023
Resolved 4 December 2025
Resolution: Past deficiency that was corrected but not cleared.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 May 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel is not equipped with closure devices for the engine room's air intakes. Provide a means to readily close air intakes to the engine room to the satisfaction of the attending marine inspector prior to movement of the vessel and seal the penetrations in the engine rooms forward and aft bulkhead. 46 CFR 182.465
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 20 May 2022
Resolved 25 May 2022
Resolution: Adequately installed close device for engine room air intake.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 May 2022
Resolved
Collision bulkheads must not be fitted with any type of penetration or opening except penetrations may be made if they are located as high and as far inboard as practicable and they have a means to make them watertight. Make penetrations made by the vessel's hydraulic hoses watertight. 46 CFR 179.310 (a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 25 May 2022
Resolution: Collision bulkhead penatrations made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Repair or replace exposed wire above the aft of the port engine. 46 CFR 183.200
Action required: 60 - Rectify deficiencies prior to movement
Due 20 May 2022
Resolved 25 May 2022
Resolution: Exposed wire above port engine made repaired.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 May 2022
Resolved
emote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high. The labels for the vessel's fuel shut should be closer to the shutoff. Move label to its original position. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 25 May 2022
Resolution: Remote fuel shutoff properly labeled.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 May 2022
Resolved
Vessels with upper decks that permit passengers are limited by stability criteria to a maximum number of passenger permitted on the upper deck and must be indicated with a durable marking of at least 1" numbers and letters at the entranceway to the deck. Marine Inspectors observed the marking with maximum passenger count at the entranceway to the upper deck was missing. Install marking to indicate a maximum of 47 passengers permitted on upper deck. 46 CFR 185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 25 May 2022
Resolution: Upperdeck maximum passengers permitted labled on stairway leading to upperdeck.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 May 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation. Marine Inspector observed chart of large scale and area of operation was missing. Provide up-to-date chart for area of navigation. 46 CFR 184.420(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Due 20 May 2022
Resolved 25 May 2022
Resolution: Up to date charts provided on bridge.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 March 2022
Resolved
Marine inspectors shall inspect all accessible parts of the exterior and interior of the hull to ensure a satisfactory condition of the hull structure. In the vessels second compartment from the bow submit a written repair proposal to the the connection between the port side stiffener and the hull to the satisfaction of the attending marine inspector. 46 CFR 176.25-5(A)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2022
Resolved 26 May 2022
Resolution: Satisfactory repairs were made to the vessel stiffener.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 March 2022
Resolved
Marine inspectors shall inspect all railings and bulwarks and their attachment to the hull structure.
On the vessel’s port and starboard gangway access the connection between the handrail and the deck show signs of rot and water ingress. Submit a repair proposal to the satisfaction of the the attending marine inspector. 46 CFR176.24-5(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2022
Resolved 26 May 2022
Resolution: Satisfactory repaired rails.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2022
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 46 CFR 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel has not completed its annual inspection within the alloted period. 46 CFR 176.502
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2022
Resolved 25 May 2022
Resolution: Completed an annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2022
Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structural examinations required by 46 CFR 176.600(c)(1). Vessel has not completed its drydock and internal structural examinations within the alloted period. 46 CFR 176.600
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2022
Resolved 4 March 2022
Resolution: Completed hull inspection
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 August 2021
Resolved
At each inspection, galleys may be examined to determine serviceable condition. The grease extraction hood should be cleaned.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 27 September 2021
Resolution: Grease extraction hood cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 August 2021
Resolved
The life float’s floating water light must be attached around the body of the float with a lanyard of at least 18 feet. One of the vessel’s life float has an inadequate lanyard. Replace with an adequate lanyard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 27 September 2021
Resolution: Adequate lanyard installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 August 2021
Resolved
A vessel must carry either a first aid kit approval series 160.041 or equivalent contents. Provide vessel with an adequately equipped first aid kit.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 27 September 2021
Resolution: Proper first aid kit installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 August 2021
Resolved
Limited coastwise route vessels must carry six hand red flares and six orange smoke flares or 12 hand red flares. Vessel is currently equipped with four red hand flares and three orange smoke flares. Provide adequate number of flares. Vessel is limited to a lakes bays and sounds route until satisfied.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 27 September 2021
Resolution: Proper flares on board the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 August 2021
Resolved
Rails on passenger decks of a vessel engaged in excursion trips must be at least 39.5 inches high. Rail courses or equivalent must be installed between the top rail. On passenger vessels engaged in excursion trip must have bars, slats, or rail courses spaced not more than 4 inches. Vessel’s lower deck rail height is 36” and upper deck’s courses are 9.5” a part. Submit a repair proposal and conduct satisfactory installation prior to operating in the 2022 season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 January 2022
Resolved 26 May 2022
Resolution: All rails and courses have been corrected to meet excursion vessel standards.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 December 2020
Resolved
A vessel must carry either a first-aid kit approved under 46CFR160.041 or a kit with equivalent contents and instruction. Vessel's first-aid kit missing Aspirin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
Resolution: Verified aspirin in first-aid kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2020
Resolved
Vessel equipment shall be in working order to the cognizant OCMI as good Marine practice. Vessel's anchor winless inoperable preventing safe recovery of the anchor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
Resolution: Observed operation of anchor winless.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2020
Resolved
Vessel equipment shall be in working order to the cognizant OCMI as good Marine practice. STBD engine lube oil filter incorrectly installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2020
Resolved
Diesel fuel flexible hose shall be fabricated to ASTM D1692 standard. Port engine flexible fuel oil hose external coating waisted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
Resolution: Verified new flexible hoses installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2020
Resolved
All electrical installations shall be to the satisfaction of the Marine Inspector. Dead end wires located in the pilot house need to be terminated or removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
Resolution: Verified dead end wires removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 July 2020
Resolved
46 CFR 177.100 Construction & arrangement of the vessel must allow for safe operation of the vessel. The aft stbd corner of the superstructure has minor damage. Repair to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 January 2020
Resolved
Flexible electric cord and cables must meet Section 400-7 of the National Electric Code. Found household extension cord running to battery charger in engine room. Bring cable into compliance with National Electric Code to satisfaction of attending CGMI.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed boat cable running to battery charger.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020
Resolved
Machinery items shall be in proper operating condition and fit for the service in whcih they are intended. Found marine growth in port side fuel filter. O/O explained that he changes this filter frequently. Clean fuel tank and fuel filter to satisfaction and of attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed clean fuel filters and received paperwork from cleaned port fuel tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020
Resolved
Main propulsion machinery and cooling water system shall be fit for their intended service. Found leak in flexible hose on port side engine cooling system. Repair or replace hose to satisfaction of attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed replaced hose with engine running.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020
Resolved
Main propulsion machinery should be in proper operating condition and fit for intended service. Found oil leak from starboard side engine flexible hose. Repair or replace to satisfaction of attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed replaced hose with engine running.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020
Resolved
Main propulsion machinery should be in proper operating condition and fit for intended service. Port shaft showed excessive leaking. Repair or replace port side shaft packing to satisfaction of attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed replaced port shaft packing with engine running.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 January 2020
Resolved
Bilge systems should be in proper operating condition and fit for inteded service. Found several clogged bilge suction strainers. Clean or replace to satisfaction attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed cleaned bilge strainers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 January 2020
Resolved
Cable supports shall be supported by metal clips. Found plastic clips and zip ties throughout vessel. Replace cable supports to satisfaction of attending CGMI.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed new metal supports throughout vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2019
Resolved
A vessel of at least 26 feet in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Bilge suction in lazarette had hole in piping three inches above suction pad. Replace bilge pipe in accordance with appropriate specification and to the satisfaction of attending Coast Guard marine inspector. (46 CFR 182.510(a))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2019
Resolved 26 February 2019
Resolution: New pipe installed for bilge system in lazarette.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 December 2016
Resolved
Crew members shall conduct sufficient drills. Crew members were unable to safely recover person from water. Get suitable platform for recovery prior to carrying passengers to the satisfaction of the MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2017
Resolution: Crew demonstrated that they were successfully able to recover man overboard from water with new recovery ladder.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 21 December 2016
Resolved
Pipes that penetrate the hull below 6 inches above the deepest subdivision load line must have means to prevent water from entering the vessel. The gate valve on the nonfunctioning sewage overboard is broken in the closed position. Cap valve with a plug of equal material to the satisfaction of the MI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 20 January 2017
Resolution: Metal cap was placed over gate valve on nonfunctioning sewage overboard piping.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 December 2016
Resolved
Vessel should be issued a Safety Radiotelephony Certificate by a technician. Call sign listed on Safety Radiotelephony Certificate is incorrect. Have technician correct call sign on Safety Radiotelephony Certificate to the satisfaction of the MI.
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 3 January 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 30 November 2015
Resolved
A vessel must comply with applicable requirements for any radio... Renew expired FCC Radio Safety Cert. Provide proof to attending MI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 21 December 2015
Resolution: Owner provided proof of current FCC Radio Safety Certification.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 30 November 2015
Resolved
Generators designed for 40 degrees Celsius may be used if de-rated to 80% of full load rating and additional name plate specifying the de-rated capacity. Obtain data plate and install to the satisfaction of the attending MI,
Condition: Improper Installation
Due 30 December 2015
Resolved 30 December 2015
Resolution: Owner supplied letter confirming generator capacity had been de-rated from 16kw to 12.5kw. In addition the owner affixed a data plate specifying the de-rated capacity.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 January 2012
Resolved
Provide proof of servicing and proper operation of pre-engineered fixed fire suppression system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2012
Resolution: Demonstrated proper operation of Pre-Engineered FF System.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 10 January 2012
Resolved
Water hose for stbd shaft seal cooling damaged and leaking. Repair to satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 24 January 2012
Resolved 31 January 2012
Resolution: vessel replaced hose fitting and hose clamps which stopped the leaking. Cleared CG-835.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 10 January 2012
Resolved
Excessive leaking on port shaft seal. Repair to satisfaction of attending CG Marine Inspector.
Due 24 January 2012
Resolved 10 January 2012
Resolution: Corrected on the spot, tightened packing.
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 January 2012
Resolved
Conduct drills for fire and man overboard, test all applicable navigation and machinery equipment to satisfaction of attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2012
Resolution: Conducted satisfactory Fire fighting and man overboard drills.
Engineering › Bilge Water Management System › Piping
Issued 2 March 2011
Resolved
Prior to carrying passengers, prove installation of metallic piping for all vital bilge/fire system piping IAW 182.40-5. Prior to carrying passengers prove proper operation of bilge/fire system IAW 176.25. To be completed no later than 30 days and to be cleared by a CG Marine Inspector.
Action required: 705 - Other - as specified
Due 4 April 2011
Resolved 8 April 2011
Resolution: Metallic piping installed on all vital bilge/fire system piping. Bilge/fire system operating properly.
Engineering › Bilge Water Management System › Piping
Issued 6 December 2010
Resolved
Prior to carrying passengers vessel shall replace rigid non-metallic bilge piping with metallic bilge piping IAW 46CFR 182.40-5 (Old T). Submit plans to Sector Hampton Roads prior to conducting work. To be completed no later than 60 days and to be cleared by a CG Marine Inspector.
Due 4 March 2011
Resolved 2 March 2011
Resolution: Verified metallic bilge piping installed.
Engineering › Bilge Water Management System › Valve
Issued 6 December 2010
Resolved
Provide check valve in bilge system line IAW 46 CFR 182.520 w/in 7 days.
Action required: 705 - Other - as specified
Due 12 April 2011
Resolved 8 April 2011
Resolution: Check valves installed in bilge lines. Bilge system operationally tested; all sat.
Engineering › Bilge Water Management System › Piping
Issued 2 December 2010
Resolved
Replace all bilge piping with ferrous material piping IAW "old T" 46 CFR 182.40.5(b). Submit plans for replacement to Sector Hampton Roads prior to work. Work to be completed NLT 06 Dec 10. Work to be cleared by a CG marine inspector.
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 6 December 2010
Resolution: Bilge repair granted extension by Sector Hampton Roads. Re-issued CG-835 extending completion date to 60 days from 06 Dec 10.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 3 February 2010
Resolved
MARK UPPER DECK WITH MAXIMUM PASSENGERS ALLOWED WITHIN 30 DAYS.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 1 March 2010
Resolution: Upper deck marked with maximum passengers
Lifesaving › Lifefloat › Retroreflective Material
Issued 3 February 2010
Resolved
REPLACE RETRO ON LIFEFLOATS AS NECESSARY FOR WORN PIECES WITHIN 30 DAYS.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 1 March 2010
Resolution: New retro installed on life floats.
Engineering › Generator (propulsion-electric) › Generator Voltage Regulator Circuitry
Issued 14 January 2009
Resolved
Prove proper operation of required gauges on generator.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 28 January 2009
Resolution: Proved proper operation of required gauges on generator.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 20 November 2007
Resolved
Tighten starboard side tailshaft packing IAW 46 CFR 176.630.
Due 20 November 2007
Resolved 20 November 2007
Resolution: Tightened starboard side tailshaft packing IAW 46 CFR 176.630.
Stability › Watertight Integrity › General
Issued 20 November 2007
Resolved
Tighten the #2, #3, and #4 watertight hatches IAW 46 CFR 171.124.
Due 20 November 2007
Resolved 20 November 2007
Resolution: Tightened the #2, #3, and #4 watertight hatches IAW 46 CFR 171.124.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 24 January 2007
Resolved
Current testing being administered by company is 25% not 50% established by Coast Guard Regulations. Program is a company managed program.
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 16 February 2007
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 24 January 2007
Resolved
Company not prepared to perform Serious Marine Incident testing , no kits on board, or plan in place to test.
Due 7 March 2007
Resolved 16 February 2007
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 January 2007
Resolved
Employee Assistance Program training for supervisor and crew members, hotline numbers, substance abuse professional not identified.
Due 7 March 2007
Resolved 16 February 2007
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 January 2007
Resolved
Management Information Systems report has yet to be filed by company and no proof of this document ever being filed.
Due 7 March 2007
Resolved 16 February 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 January 2007
Resolved
Provide current Navagation publications Coast Pilot and Coast Guard Light List.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 29 January 2007
Resolution: Provided current Nav pubs.
Navigation › Piloting/Steering › Marine Charts
Issued 23 January 2007
Resolved
Provide current upto date nautical Charts.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 29 January 2007
Resolution: Provided current charts.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 23 January 2007
Resolved
Replace Floating Electric Waterlight batteries with approved type.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 29 January 2007
Resolution: Provided proper batteries for waterlights.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 24 February 2005
Resolved
Replace missing 50lb Halon cylinder or replace fixed extinguishing system
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2005
Resolved 8 April 2005
Resolution: Replace missing fixed fire extinguishing cylinder.
Lifesaving › Hand Flares › Quantity
Issued 24 February 2005
Resolved
Provide 3 red hand flares IAW 46 CFR 180.68
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2005
Resolved 8 April 2005
Resolution: Provided three red hand flares.
Lifesaving › Lifefloat › Painter
Issued 24 February 2005
Resolved
Secure painter to vessel and Lifefloat IAW 46 CFR 180.130.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2005
Resolved 8 April 2005
Resolution: Lifeboat secured to vessel via sea painter.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 February 2005
Resolved
Conduct U/W man overboard drill.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2005
Resolved 8 April 2005
Resolution: Conducted satisfactory U/W man overboard drills.
Engineering › Shafting/Propeller Arrangements
Issued 14 February 2003
Resolved
Provide repairs to port and starboard main propulsion shafts - excessive leakage at port shaft stuffing box and broken line on starboard shaft cooling water system. Vessel is restricted from carrying passengers until repairs to port and starboard shafts are made to satisfaction of attending [name withheld]: Propeller Shaft
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2003
Resolved 21 February 2003
Resolution: Replaced packing on port shaft. Replaced line for shaft cooling water system on starboard shaft. Got vessel underway to test repairs - both shafts satisfactory.
Lifesaving
Issued 30 November 1998
Resolved
CONDUCT MAN OVERBOARD, FIRE, AND EMERGENCY DRILLS WHILE UNDERWAY IN THE PRESENCE OF A MARINE INSPECTOR; VESSEL IS RESTRICTED FROM CARRYING PASSENGERS UNTIL COMPLETED.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Construction/Loadline
Issued 26 January 1997
Resolved
REPLACE MISSING GASKET AROUND FORWARD MOST HATCH.
Condition: Unknown
Due 26 January 1997
Resolved 26 January 1997
Construction/Loadline
Issued 3 December 1995
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE REPAIRS TO HOLE IN THE FUEL TANK SPACE ON THE PORT SIDE. REPAIRS ARE TO BE MADE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 December 1995
Resolved 3 December 1995
Accommodation/Occupational Safety
Issued 7 October 1992
Resolved
AFFECT PERMANENT REPAIRS TO LEAKING PORTSIDE MARINE SANITATION HOLDING TANK
Condition: Unknown
Due 7 October 1992
Resolved 7 October 1992
Navigation
Issued 9 April 1991
Resolved
PROVIDE VSL DAY SHAPES 3 BALLS 2 TRIANGLES. ENSURE CORRECT SIZE IAW NAV RULES.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Lifesaving
Issued 9 April 1991
Resolved
PROVIDE PADDLES FOR LIFEFLOATS X4 FOR 2 L/F.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Engineering
Issued 9 April 1991
Resolved
PROVIDE MEANS OF STOPPING PORTSIDE MDE FROM PILOTHOUSE.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Lifesaving
Issued 28 April 1989
Resolved
STENCIL NAME AND CAPACITY ON LIFE FLOATS.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Lifesaving
Issued 28 April 1989
Resolved
RAISE CHILDS JACKETS TO THE TOP OF THE BOX SO THAT THEY CAN BR REACHED. THE BOX IS TO TALL AND NARROW TO RETREIVE JACKETS FROM THE BOTTOM.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Construction/Loadline
Issued 12 December 1988
Resolved
MAKE ALL MAIN DECK HATCHES WATERTIGHT OR AS PERMITTED BY 46 CFR 171.124 OR DRAIN OVBD.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Deck/Cargo
Issued 12 December 1988
Resolved
INSTALL OVBD VENT WITH FLAME SCREEN FOR HOLDING TANK.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Lifesaving
Issued 12 December 1988
Resolved
PROVIDE ONE (1) ADDITIONAL CHILD PFD.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Documentation
Issued 12 December 1988
Resolved
MAINTAIN ORIGINAL CERTIFICATE OF DOCUMENTATION ON BOARD PRIOR TO OPERATING.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Accommodation/Occupational Safety
Issued 12 December 1988
Resolved
INSTALL MEANS TO INDICATE WHEN HOLDING TANK IS 3/4 FULL.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Deck/Cargo
Issued 12 December 1988
Resolved
INSTALL CHECK VALVE IN BILGE SYSTEM IAW 46 CFR 18.25-5(C).
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Accommodation/Occupational Safety
Issued 12 December 1988
Resolved
INSTALL FREQ. METER FOR AC GEN.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988