Records from 2016 to 2025. Most recent: inspection, 24 November 2025.
Inspection history · 28
24 November 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8273155
4 November 2025
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8253423
3 March 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8081489
26 December 2024
Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8050969
21 March 2024
Internal Structural Exam · Drydock Exam · Deficiency Check · Drydock Extension
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7885052
8 March 2024
Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7946569
4 March 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7873828
27 February 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7641323
20 May 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7454807
11 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7409589
4 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7406112
13 August 2021
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7285456
23 December 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7119545
3 December 2020
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7100362
17 July 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7007049
22 May 2020
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6928670
16 January 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6890741
3 January 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6872904
26 February 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6631706
14 February 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6614472
25 January 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6614983
15 March 2018
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6373260
14 December 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6323585
22 March 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6109400
20 January 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6074081
3 January 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6064847
21 December 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6053522
24 February 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5818095
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2025
Resolved
All vessels shall be provided with bilge pumps. Vessel unable to get suction and pump overboard in the engine room and hold below the bar. 46CFR182.25-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2025
Resolution: MI witnessed suction and dewatering in both spaces.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2025
Resolved
Portable fire extinguishers shall be installed to OCMI satisfaction. Mounting brackets seized and difficult to remove portable fire extinguisher in emergency. Replaced mounting brackets to satisfaction of attending MI. 46CFR181.30-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Portable fire extinguishers brackets that would freeze shut were all replaced with quick release mounting brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 November 2025
Resolved
The name of the vessel and person capacity shall be clearly marked on each life float. Life floats were not marked that the MI's were able to verify. 46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Pax capacity and vessel name stenciled on 03 life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 November 2025
Resolved
Each life ring shall have tipe II retroflective tape. Retro worn and inneffective and requires replacement. 46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Life ring retroflective tape replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2025
Resolved
Fixed fire extinguishing systems shall be installed and maintained are are subject to hydrostatic testing at intervals of 12-years or less. MI unable to identify proof of hydrostatic test within 12-years. 46CFR181.20-1, NFPA 7.3.2.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: O/O provided proof of a full visual inspection within 5-years. This is permitted in [name withheld] 02-12. Requalification Identification Number (RIN) is V113056.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 November 2025
Resolved
Each lighting fixture must be of the fixed type. Several portable overhead lights plugged into an outlet identified in interior spaces. Remove or make permanently fixed to the satisfaction of attending MI. 46CFR183.410
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: O/O opted to remove all plug in lighting in the snack bar and waste holding tank spaces.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 November 2025
Resolved
Wiring joints and splices shall be mechanically secure and made in a junction box. Several junction boxes and outlets found open, cracked or not watertight. 46CFR183.05-50
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: All outlets and junction boxes replaced and closed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2025
Resolved
Visual and audible alarm required at operating station for high water level in unmanned spaces. #3 hold, engine room and lazerette spaces high water light at the operating station visually displayed high water in several compartments when one compartment was tested. 46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Verified all four spaces with high water alarms were audible and visual on the bridge.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 March 2025
Resolved
Each vessel that operates beyond 3-NM from the coastline shall have an EPIRB intalled to automatically float free. Hydrostatic release expired. Vessel restricted to within 3-NM from shore until replaced and attested to by MI. 46CFR180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 March 2025
Resolution: New HRU placed in service on vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 March 2025
Resolved
Any vessel of at least 5 net tons must have a certificate of documentation. Vessel's COD onboard expired. Provide proof of valid COD and retain copy onboard. 46CFR67.7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2025
Resolution: O/O produced current COD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 March 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears and rotating machinery. Rotating belt exposed on the generator in an an exposed area in the engine room. 46CFR177.35-15.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2025
Resolution: Aluminum guard placed over belt.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 March 2025
Resolved
Penetrations and opendings in watertight bulkheads must be kept as high and as far inboard as practicable and have a means to make them watertight. Watertight bulkead aft of the anchor chamber has an opening low and center in the bulkhead wall with cables running through it that is not watertight. Make bulkhead watertight and ready for further inspection by MI. 46CFR171.114
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2025
Resolution: O/O filled holes, bulkhead watertight.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2024
Resolved
A vessel must carry either a first aid kit approved
under approval series 160.041 or a kit with equivalent
content and instructions. Vessel did not have all
required equivalent contents of a first aid kit approved
under 160.041. Provide equivalent contents or a first
aid kit approved under 160.041.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 7 March 2024
Resolution: Owner provided vessel with additional First Aid kit supplies
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 4 March 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessels two 22 man life floats where found to be not in serviceable condition as evidenced by extensive UV deterioration and large openings exposing the foam flotation material. The exposed foam flotation material was found to be severely UV damaged and crumbling into pieces. Both life floats must be replaced by vessel owner. A temporary repair of life floats may be authorized by attending MI until both life floats are permanently replaced. Owner must send MI repair proposal for life floats for approval. Upon approval of temporary repair proposal, life floats must be visually examined by attending MI and satisfactorily float tested in the water in the presence of the attending MI. Vessel is restricted from operating less then 1NM from shore until life floats are replaced or temporary repair is satisfactory.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2024
Resolved 8 March 2024
Resolution: Owner temporarily repaired life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2024
Resolved
An adult life jacket must be provided for each person carried onboard. Vessel owner/operator provided 120 adult life jackets which does provide the proper amount for 121 adult passengers listed on the COI. Vessel owner must provide an additional life jacket or reduce passenger count to a total of 120 adult passengers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 8 March 2024
Resolution: Owner provided aditional PFD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2023
Resolved
Vessel's less than 65' carrying more than 49 passengers shall have a piping system and bilge pump capable of pumping 25 gallons per minute, and a portable hand pump for each space aft of the collision bulkhead. Vessel's bilge pump is not operational. 46CFR182.25-5; 46CFR182.25-10
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 1 March 2023
Resolution: Witness operational test of the bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in unmanned spaces. The visual alarm worked in space #3 aft of the kitchen, however, the audible alarm was inoperable. 46CFR182.530
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 1 March 2023
Resolution: Witnessed operational audible and visual alarm test of the #3 hold aft of the kitchen.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 February 2023
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Two pipe penetrations from the tank room to the engine room need to be made watertight, and two pipe penetrations from the engine room to the steering gear room need to be made watertight. 46CFR171.114
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 1 March 2023
Resolution: Watertight bulkhead penetrations made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 27 February 2023
Resolved
A vessel must be fitted with ground tackle appropriate for the vessel and waters on which it operates. Forward starboard cleat not properly secured to the vessel. 46CFR184.10-1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2023
Resolved 4 December 2025
Resolution: Past deficiency that was corrected but not cleared.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 May 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel is not equipped with closure devices for the engine room's air intakes. Provide a means to readily close air intakes to the engine room to the satisfaction of the attending marine inspector prior to movement of the vessel and seal the penetrations in the engine rooms forward and aft bulkhead. 46 CFR 182.465
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 20 May 2022
Resolved 25 May 2022
Resolution: Adequately installed close device for engine room air intake.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 May 2022
Resolved
Collision bulkheads must not be fitted with any type of penetration or opening except penetrations may be made if they are located as high and as far inboard as practicable and they have a means to make them watertight. Make penetrations made by the vessel's hydraulic hoses watertight. 46 CFR 179.310 (a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 25 May 2022
Resolution: Collision bulkhead penatrations made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Repair or replace exposed wire above the aft of the port engine. 46 CFR 183.200
Action required: 60 - Rectify deficiencies prior to movement
Due 20 May 2022
Resolved 25 May 2022
Resolution: Exposed wire above port engine made repaired.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 May 2022
Resolved
emote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high. The labels for the vessel's fuel shut should be closer to the shutoff. Move label to its original position. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 25 May 2022
Resolution: Remote fuel shutoff properly labeled.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 May 2022
Resolved
Vessels with upper decks that permit passengers are limited by stability criteria to a maximum number of passenger permitted on the upper deck and must be indicated with a durable marking of at least 1" numbers and letters at the entranceway to the deck. Marine Inspectors observed the marking with maximum passenger count at the entranceway to the upper deck was missing. Install marking to indicate a maximum of 47 passengers permitted on upper deck. 46 CFR 185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 25 May 2022
Resolution: Upperdeck maximum passengers permitted labled on stairway leading to upperdeck.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 May 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation. Marine Inspector observed chart of large scale and area of operation was missing. Provide up-to-date chart for area of navigation. 46 CFR 184.420(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Due 20 May 2022
Resolved 25 May 2022
Resolution: Up to date charts provided on bridge.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 March 2022
Resolved
Marine inspectors shall inspect all accessible parts of the exterior and interior of the hull to ensure a satisfactory condition of the hull structure. In the vessels second compartment from the bow submit a written repair proposal to the the connection between the port side stiffener and the hull to the satisfaction of the attending marine inspector. 46 CFR 176.25-5(A)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2022
Resolved 26 May 2022
Resolution: Satisfactory repairs were made to the vessel stiffener.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 March 2022
Resolved
Marine inspectors shall inspect all railings and bulwarks and their attachment to the hull structure.
On the vessel’s port and starboard gangway access the connection between the handrail and the deck show signs of rot and water ingress. Submit a repair proposal to the satisfaction of the the attending marine inspector. 46 CFR176.24-5(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2022
Resolved 26 May 2022
Resolution: Satisfactory repaired rails.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2022
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 46 CFR 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel has not completed its annual inspection within the alloted period. 46 CFR 176.502
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2022
Resolved 25 May 2022
Resolution: Completed an annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2022
Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structural examinations required by 46 CFR 176.600(c)(1). Vessel has not completed its drydock and internal structural examinations within the alloted period. 46 CFR 176.600
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2022
Resolved 4 March 2022
Resolution: Completed hull inspection
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 August 2021
Resolved
At each inspection, galleys may be examined to determine serviceable condition. The grease extraction hood should be cleaned.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 27 September 2021
Resolution: Grease extraction hood cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 August 2021
Resolved
The life float’s floating water light must be attached around the body of the float with a lanyard of at least 18 feet. One of the vessel’s life float has an inadequate lanyard. Replace with an adequate lanyard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 27 September 2021
Resolution: Adequate lanyard installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 August 2021
Resolved
A vessel must carry either a first aid kit approval series 160.041 or equivalent contents. Provide vessel with an adequately equipped first aid kit.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 27 September 2021
Resolution: Proper first aid kit installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 August 2021
Resolved
Limited coastwise route vessels must carry six hand red flares and six orange smoke flares or 12 hand red flares. Vessel is currently equipped with four red hand flares and three orange smoke flares. Provide adequate number of flares. Vessel is limited to a lakes bays and sounds route until satisfied.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 27 September 2021
Resolution: Proper flares on board the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 August 2021
Resolved
Rails on passenger decks of a vessel engaged in excursion trips must be at least 39.5 inches high. Rail courses or equivalent must be installed between the top rail. On passenger vessels engaged in excursion trip must have bars, slats, or rail courses spaced not more than 4 inches. Vessel’s lower deck rail height is 36” and upper deck’s courses are 9.5” a part. Submit a repair proposal and conduct satisfactory installation prior to operating in the 2022 season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 January 2022
Resolved 26 May 2022
Resolution: All rails and courses have been corrected to meet excursion vessel standards.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 December 2020
Resolved
A vessel must carry either a first-aid kit approved under 46CFR160.041 or a kit with equivalent contents and instruction. Vessel's first-aid kit missing Aspirin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
Resolution: Verified aspirin in first-aid kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2020
Resolved
Vessel equipment shall be in working order to the cognizant OCMI as good Marine practice. Vessel's anchor winless inoperable preventing safe recovery of the anchor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
Resolution: Observed operation of anchor winless.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2020
Resolved
Vessel equipment shall be in working order to the cognizant OCMI as good Marine practice. STBD engine lube oil filter incorrectly installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2020
Resolved
Diesel fuel flexible hose shall be fabricated to ASTM D1692 standard. Port engine flexible fuel oil hose external coating waisted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
Resolution: Verified new flexible hoses installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2020
Resolved
All electrical installations shall be to the satisfaction of the Marine Inspector. Dead end wires located in the pilot house need to be terminated or removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 23 December 2020
Resolution: Verified dead end wires removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 July 2020
Resolved
46 CFR 177.100 Construction & arrangement of the vessel must allow for safe operation of the vessel. The aft stbd corner of the superstructure has minor damage. Repair to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 January 2020
Resolved
Flexible electric cord and cables must meet Section 400-7 of the National Electric Code. Found household extension cord running to battery charger in engine room. Bring cable into compliance with National Electric Code to satisfaction of attending CGMI.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed boat cable running to battery charger.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020
Resolved
Machinery items shall be in proper operating condition and fit for the service in whcih they are intended. Found marine growth in port side fuel filter. O/O explained that he changes this filter frequently. Clean fuel tank and fuel filter to satisfaction and of attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed clean fuel filters and received paperwork from cleaned port fuel tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020
Resolved
Main propulsion machinery and cooling water system shall be fit for their intended service. Found leak in flexible hose on port side engine cooling system. Repair or replace hose to satisfaction of attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed replaced hose with engine running.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020
Resolved
Main propulsion machinery should be in proper operating condition and fit for intended service. Found oil leak from starboard side engine flexible hose. Repair or replace to satisfaction of attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed replaced hose with engine running.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020
Resolved
Main propulsion machinery should be in proper operating condition and fit for intended service. Port shaft showed excessive leaking. Repair or replace port side shaft packing to satisfaction of attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed replaced port shaft packing with engine running.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 January 2020
Resolved
Bilge systems should be in proper operating condition and fit for inteded service. Found several clogged bilge suction strainers. Clean or replace to satisfaction attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed cleaned bilge strainers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 January 2020
Resolved
Cable supports shall be supported by metal clips. Found plastic clips and zip ties throughout vessel. Replace cable supports to satisfaction of attending CGMI.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2020
Resolution: Observed new metal supports throughout vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2019
Resolved
A vessel of at least 26 feet in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Bilge suction in lazarette had hole in piping three inches above suction pad. Replace bilge pipe in accordance with appropriate specification and to the satisfaction of attending Coast Guard marine inspector. (46 CFR 182.510(a))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2019
Resolved 26 February 2019
Resolution: New pipe installed for bilge system in lazarette.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 December 2016
Resolved
Crew members shall conduct sufficient drills. Crew members were unable to safely recover person from water. Get suitable platform for recovery prior to carrying passengers to the satisfaction of the MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2017
Resolution: Crew demonstrated that they were successfully able to recover man overboard from water with new recovery ladder.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 21 December 2016
Resolved
Pipes that penetrate the hull below 6 inches above the deepest subdivision load line must have means to prevent water from entering the vessel. The gate valve on the nonfunctioning sewage overboard is broken in the closed position. Cap valve with a plug of equal material to the satisfaction of the MI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 20 January 2017
Resolution: Metal cap was placed over gate valve on nonfunctioning sewage overboard piping.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 December 2016
Resolved
Vessel should be issued a Safety Radiotelephony Certificate by a technician. Call sign listed on Safety Radiotelephony Certificate is incorrect. Have technician correct call sign on Safety Radiotelephony Certificate to the satisfaction of the MI.
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 3 January 2017