MAURY USCG vessel records Sign in
← All vessels

AMERA

AMERA is a 1988 passenger vessel (inspected). The Coast Guard has recorded 123 inspections since 1988, most recently in February 2026, along with 89 deficiencies and 4 operational controls.

Records from 1988 to 2026. Most recent: inspection, 13 February 2026.

Built
1988
Last inspected
13 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8700280 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
322151
Flag
BAHAMAS, THE
—
Maury page id
psix-322151

Inspections, by type

…with no type recorded51
Years with a record 32 calendar years (1988–2026)
The 123 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it39051 - Convention (Subpart B), Gross Ton
39051 - Regulatory (Subpart C or D), Gross Ton
14851 - Convention (Subpart B), Net Ton
21410 - Displacement, Ton
6150 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BOSTON Freight Barge · MISLE 43223 · 18 April 1997 · activity 523470CSM 30 Tank Barge · MISLE 45642 · 24 April 1995 · activity 497484MONTE VERDE Tank Ship · MISLE 227786 · 6 October 1992 · activity 174677

Inspection history · 123

13 February 2026 COC-CVE Quarterly · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8312451
3 April 2025 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8103828
31 March 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8102290
8 May 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7908496
25 April 2024 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7900539
22 April 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7899320
28 March 2023 COC-CVE Initial · PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7654906
27 March 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7657840
29 November 2022 COC-CVE Initial
Administrative · Activities Europe · Activity 7594493
9 November 2018 ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6577274
5 May 2018 Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6403263
18 December 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6325927
13 November 2017 COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6305871
18 November 2016 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6043846
8 January 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5793807
24 November 2015 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5766532
14 March 2014 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4816916
22 December 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3916849
17 December 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3915171
29 November 2010 ISPS II Exam · Deficiency Check · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3898046
4 January 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3658927
27 April 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3461821
23 November 2008 MARPOL Annex I Examination · ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3366788
28 December 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3121653
17 December 2007 PII Safety Exam · MARPOL Annex II Examination · Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3112504
4 May 2007 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2922420
5 January 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2850510
2 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2849014
4 January 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2561555
1 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2559042
28 November 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2587067
24 November 2005 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2538944
4 February 2005 NPV Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2287287
30 January 2005 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2283110
19 December 2004 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2263266
19 November 2004 ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2244194
7 May 2004 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2061989
26 January 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1993109
20 January 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1988396
20 January 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1989098
19 December 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1967071
9 December 2003 Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1959021
9 December 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1961354
23 October 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1934368
22 October 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1934297
21 October 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1933199
2 October 2003 Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1919625
12 September 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1903441
21 July 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1868364
7 July 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1843455
28 June 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1874434
31 May 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1806646
8 May 2003 Control Verification · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1789988
8 May 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1804994
21 December 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1476819
18 December 2001 Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1477064
28 September 2001 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 293675
28 September 2001 Quarterly Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 773198
16 April 2001 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466208
30 October 2000 MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379217
7 August 2000 Quarterly Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1430900
27 March 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 276205
18 March 2000 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1372966
12 January 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 273625
12 January 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1047988
12 December 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 811770
9 December 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 434296
9 December 1999 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 813375
17 May 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 428735
12 May 1999 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 796658
18 April 1999 Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1472350
22 January 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 424835
22 January 1999 Quarterly Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386412
21 October 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 484596
21 October 1998 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 806825
7 May 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 469519
21 April 1998 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1430534
28 November 1997 Control Verification · MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1450103
18 April 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 523470
16 April 1997 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1371759
16 December 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 398562
16 December 1996 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1357837
23 December 1995 MARPOL Annex V Examination · Control Verification · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1430124
28 October 1995 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879530
19 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 882463
19 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 882467
24 April 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 447864
24 April 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 497484
18 April 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 376971
18 April 1995 MARPOL Annex V Examination · Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 854402
15 December 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396218
14 December 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 373099
17 October 1994 Control Verification · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1177610
9 May 1994 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 859279
2 May 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 652897
26 April 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 366356
19 April 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 366305
19 April 1994 Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1455150
5 December 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 362809
19 November 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1356538
8 November 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850709
24 March 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 652890
29 January 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 831373
6 January 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 451967
13 December 1992 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 355608
13 December 1992 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1428166
6 October 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 174677
1 October 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1389585
16 September 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 353133
16 September 1992 Control Verification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1257024
5 April 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 349936
5 April 1992 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1267973
14 November 1991 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 932317
5 September 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 942685
22 April 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 343498
22 April 1991 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1306808
5 January 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 341520
5 January 1991 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 901395
25 April 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 900154
11 December 1989 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 922756
26 August 1989 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 887592
18 April 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1340636
13 December 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1211970

Deficiency record · 89

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2024 Resolved
Before the ship and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Port side rescue boat engine is unable to start. 74 SOLAS 20 CH III/Reg 20.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 25 April 2024
Resolution: Received email from staff captain the vessel's rescue boat is operational.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 April 2024 Resolved
The speed of door closure shall, if necesssary, be controlled so as to prevent undue danger to persons. Fire screen doors 465 & 463 slammed closed so quickly that anyone in the door would possibly be injured. 74 SOLAS 81 Amend. II-2/ Reg 30.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 April 2024
Resolved 25 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 April 2024 Resolved
Furniture in stairway enclosures shall be limited to seating. It shall be fixed, limited to six seats on each deck in each stairway enclosure, be of restricted fire risk, and shall not restrict the passenger and crew corridors forming escape routes in cabin areas. Inaddition lockers of non-combustible material , providing storage for safety equipment required by regulations, may be permitted. Seating in passenger stairway enclosure Deck 4 MVZ 4 and in front of the hospital was not fixed. 74 SOLAS 01 Ch II-2/Reg 41-2.4.10
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 25 April 2024
Resolved 25 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2024 Resolved
In interior locations in passenger ships carrying more than 36 passengers fire hoses shall be connected to the hydrants at all times. Interior fire hoses located in the Medical Space and FP 0621 on deck 6 was present but not connected to the hydrant. 74 SOLAS 97 II-2/4.7.1
Action required: 10 - Deficiency Rectified
Due 25 April 2024
Resolved 25 April 2024
Engineering › Thrusters › Seal
Issued 18 December 2017 Resolved
7499- After any survey of the ship no change shall be made in the machinery with the sanction of the administration. Vessels stern thruster has been taken out of service due to leaking gasket. 74 SOLAS (14 CONS.) CH.I/11(b)
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 18 January 2018
Resolution: Class survey report dated 15JAN2018 attested to the correction of deficiency.
Construction/Loadline › Structures › Superstructure
Issued 24 November 2015 Resolved
Every ship when in a part of another contracting government is subject to control by officers duly authorized by such government. Existing vessels that have undergone a major modification must complete plan review with USCG Marine Safety Center (MSC). Vessel has not completed plan review with MSC after completing major modifications, on deck 8 aft passenger cabins.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 8 January 2016
Resolution: MSC Letter provided
Engineering › Fuel Oil Service System › Tank
Issued 24 November 2015 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. The tops of tanks 801 and 802 have multiple holes and fuel leakage. Previous repairs have failed, creating a potential fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2015
Resolved 24 November 2015
Resolution: Class attended the vessel and issued a condition for temporary repairs to the tanks with permanent repairs to be made at drydock in 2016.
Construction/Loadline › Structures › Trunk
Issued 24 November 2015 Resolved
Condition: Improper Installation
Due 24 November 2015
Resolved 24 November 2015
Resolution: deficiency rectified on the spot. Combustable material was moved to a secured location.
Lifesaving › Launching Appliances › Winch
Issued 22 December 2010 Resolved
Passenger ships which are not short I'ntl voyages shall carry life rafts in substitution of life boats provided that there shall never be less than 37.5% the total number of persons on board in the life boats on each side of the ship. Life boat winch hydro motor failed on #7 life boat rendering the life boat davit inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 January 2011
Resolved 5 January 2011
Resolution: Recieved replacement part. Class report being sent.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 29 November 2010 Resolved
Fire screen doors 465 and 9-1-6 did not close completely.
Due 29 November 2010
Resolved 29 November 2010
Engineering › Compressed Air System (control) › Compressor
Issued 29 November 2010 Resolved
Modifications have been made to the ventialation in the AC Room and electrical motors have been replaced. Class must attest to the operating performance of the AC system.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 30 December 2010
Resolution: Received Class report attesting to rectification of deficiency.
Engineering › Compressed Air System (control) › Compressor
Issued 29 November 2010 Resolved
AC #2 has excessive condensation and is causing puddles.
Due 29 November 2010
Resolved 29 November 2010
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 29 November 2010 Resolved
AC Room #3 has excessive combustibles stored within thereby exceeding the fire load limitation of the space.
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 30 December 2010
Resolution: Received Class report attesting to rectification of deficiency.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 November 2010 Resolved
Found excessive load on surge protector in electronics workshop, deck 6. Also, found dead end wires on electrical panels in AC room #1.
Due 29 November 2010
Resolved 29 November 2010
Lifesaving › Buoyant Smoke Signals › General
Issued 29 November 2010 Resolved
Lifebouys on bridge wings are faded in color, not orange or red.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 30 December 2010
Resolution: Received Class report attesting to rectification of deficiency.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 November 2010 Resolved
Waste receptacles in garbage room were constructed of combustible materials. Rectify def by next US ort after sailing foreign
Action required: 15 - Rectify deficiencies by next port
Resolved 30 December 2010
Resolution: Received Class report attesting to rectification of deficiency.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 29 November 2010 Resolved
All A/C spaces, electronic work shops on deck 6 and medical spaces on 4 are missing escape markings
Due 29 November 2010
Resolved 29 November 2010
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 29 November 2010 Resolved
Quantitiy of flammable liquids in Flam Lockers in #2 Pump Room, upper level engine room, as well as the X-Ray room in medical should be limited to daily use
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 5 January 2011
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 29 November 2010 Resolved
Heat/smoke detectors in male and female saunas are inoperable
Due 29 November 2010
Resolved 29 November 2010
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 November 2010 Resolved
The IOPP does not relect the actual operating performance of the OWS due to a more powerful feeder pump having been installed
Action required: 705 - Other - as specified
Due 29 January 2011
Resolved 13 May 2011
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 20 November 2008 Resolved
Flag administration to provide written approval of liferafts servicing extension as per SOLAS ch III, reg 20
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2008
Resolution: Def corrected
Lifesaving › Inflatable Liferafts › Approval
Issued 20 November 2008 Resolved
Conduct the deployment/inflation of liferaft in presence of U.S. Coast Guard inspector.
Due 13 January 2009
Resolved 19 December 2008
Resolution: Def corrected
Fire Fighting › Ventilation Systems › Operating Controls
Issued 20 November 2008 Resolved
Prove proper operation of fire dampers #197 and #198. Currently there is no indication of closure.
Action required: 705 - Other - as specified
Due 13 January 2009
Resolved 27 April 2009
Resolution: Witnessed satisfactory operation of fire dampers #197 and 198 from the detection panel. Deficiency cleared.
Fire Fighting › Fire Hydrants › Location/Position
Issued 20 November 2008 Resolved
Flag administration to approve current Fire Control Plan onboard.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 19 December 2008
Resolution: Def corrected
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 December 2007 Resolved
On board training and instruction must be given to newly arrived crew members according to vsl policy, SMS, and SOLAS.
Action required: 705 - Other - as specified
Due 3 January 2008
Resolved 17 December 2007
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 17 December 2007 Resolved
Crew need to demonstrate liferaft proficiency thru deployment at follow-up inspeciton on Jan 3, 2008
Action required: 705 - Other - as specified
Due 3 January 2008
Resolved 3 January 2008
Lifesaving › Lifeboat Equipment › Food Ration
Issued 17 December 2007 Resolved
Lifeboat equipement had been removed from the boats at drydock and had not been placed back in the vsls upon CG inspection. Vsl was required to fix this def prior to departure.
Action required: 705 - Other - as specified
Due 17 December 2007
Resolved 3 January 2008
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 17 December 2007 Resolved
FSD's 810, 429, 206, 207, 213, 217, 305, 722 were malfunctioning. Vsl must fixed doors prior to departure or come up with alternative plan. (4 hours later) FSD 207 is now the only door that is inoperable. A 24 hour watch was placed by the door until the door is fixed. Jan 3, 2008 follow up inspection is required and these doors are to be checked.
Action required: 705 - Other - as specified
Due 3 January 2008
Resolved 3 January 2008
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 4 May 2007 Resolved
Two flammable lockers with fire protection on aft mooring deck not on fire control plan.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 4 May 2007
Resolution: All flammable lockers with fire protection on aft mooring deck now put on main fire plan and all plans are in progress of being updated.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 4 May 2007 Resolved
Excessive oily waste in engine room bilge and sludge tanks full.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 4 May 2007
Resolution: Sludge tanks and oily bilges now pumped ashore. Verified vessel has sufficient capacity for intended voyage and found satisfactory. Grey water in E/R bilge to be pumped ashore. #2 stbd bilge in pump room pumped ashore w/residue to be cleaned.
Lifesaving › Lifeboat › Hull
Issued 4 May 2007 Resolved
Life boat tenders have numerous locations of hull damage.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 4 May 2007
Resolution: Damage to various hull locations of life boat tenders (No''s 5,6,7, & 8) above waterline assessed and found to be temporarily satisfactory. Permanent repairs to be carried out by manufacturer''s rep. within 2 months.
Fire Fighting › Means of Escape › Doorways
Issued 4 May 2007 Resolved
Fire doors 511 and 706B did not close. 706B did not close while glass doors were in open position.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 4 May 2007
Resolution: Fire door 511- counter weight adjusted, tested and now fully closes. Fire door 706B - spring tensions adjusted, tested with glass doors in open position, and now fully closes. Both doors are now found to be satisfactory.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 November 2005 Resolved
Fire screen door #422 does not close properly.
Action required: 705 - Other - as specified
Due 8 December 2005
Resolved 24 December 2005
Resolution: Recieved Class report attesting satisfactory repair to the Fire screen door #422.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 November 2005 Resolved
Tailor storage of combustibles is above maximum allowable hieght.
Action required: 705 - Other - as specified
Due 8 December 2005
Resolved 24 December 2005
Resolution: Recieved Class report attesting satisfactory storage of combustibles.
Lifesaving › Lifeboat › Hull
Issued 19 November 2004 Resolved
Lifeboat tender #7 has temporary repairs by stern/port. Make permanent repairs to satisfaction of flag state rep NLT 15JAN05.
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 13 January 2005
Lifesaving › Lifeboat › Propulsion Engine
Issued 19 November 2004 Resolved
Lifeboat tender #5 has one inop engine. Vessel is not to use this lifeboat as a tender until permanent repairs are made. NLT 15JAN05.
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 13 January 2005
Fire Fighting › Structural - B Class Divisions › Doors
Issued 19 November 2004 Resolved
The following FSD's do not slose correctly: 807, B625, 506, 604. B doors need more attention.
Due 20 December 2004
Resolved 19 December 2004
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pressure
Issued 19 November 2004 Resolved
Flexi-Fog system is not funtioning properly causing system to over pressurize. Pumps are not sequencing properly and Flexi-Fog heads cannot withstand the increased pressure causign them to leak.
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 13 January 2005
Construction/Loadline › Structures › Ventilators
Issued 19 November 2004 Resolved
Indicator for damper #78 is Inop.
Due 20 December 2004
Resolved 19 December 2004
Engineering › Feedwater/Condensate Water System › Conditioner
Issued 7 May 2004 Resolved
MAKE PROPER REPAIRS TO POTABLE WATER PIPING IN PUMPROOM #1 TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 20 November 2004
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 7 May 2004 Resolved
LIFEBOAT OPS DURING ABANDON SHIP, CONDUCT OPERATIONAL TEST OF LIFEBOATS INCLUDING LOWERING, DISCONNECTING AND MANEUVERING DURING ABANDON SHIP DRILL AT NEXT U.S. PORT.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 December 2004
Resolution: Abandoned ship drill completed.
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 December 2003 Resolved
Repair leaky potable water system in pump room #2 in accordance with SOLAS CH II-1 REG 26. LEGACY COMPONENT DESC: Potable water system in pump room #2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 20 November 2004
Accommodation/Occupational Safety › Potable Water System
Issued 9 December 2003 Resolved
Repair leaking flange for 6.5 bar hot water heater in accordance with CH II-1 REG. 26. LEGACY COMPONENT DESC: 6.5 bar Hot water heater
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 4 January 2004
Resolution: New gasket now fitted to potable water tank.
Fire Fighting
Issued 28 September 2001 Resolved
WIRE RUN ABOVE DOOR #305, ELECTRICAL STUFFING TUBE TO BE CLOSED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Accommodation/Occupational Safety
Issued 28 September 2001 Resolved
FLOOR GRADING IN PASSENGER AREA IS VERY SLIPPERY - NEEDS CORRECTIVE ACTION (LOCATION: PORT SIDE, DECK 7)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 28 September 2001 Resolved
LOOSE ACTUATOR LINE ON HALON BOTTLE.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 28 September 2001 Resolved
STRUCTURAL FIRE PROTECTION (INSULATION) NEEDS TO BE REPLACED WHERE STRUCTURAL REPAIRS HAVE BEEN CONDUCTED. (LOCATIONS: SHIP'S LAUNDRY ROOM ANDLAUNDRY STORES.)
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 28 September 2001 Resolved
ELECTRICAL PIPING PENETRATIONS IN SHIP'S LAUNDRY ROOM MISSING STUFFING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 28 September 2001 Resolved
BOX W/CABLE PASS MISSING (SFP) INSULATION. (LOCATION: NEXT TO SHIP'S LAUNDRY ROOM).
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 28 September 2001 Resolved
MISSING OVERHEAD (SFP) INSULATION FOR SHIP'S INCINERATOR ROOM._x001C_
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 30 October 2000 Resolved
Submit Flag-approved Fire Control Plans to Coast Guard Marine Safety CenterIAW 46 CFR 71.65-15.
Condition: Unknown
Due 30 October 2000
Resolved 30 October 2000
Lifesaving
Issued 30 October 2000 Resolved
The vessel did not have written proof that both EPIRB's were properly registered with NOAA IAW 47 CFR 80.1061.
Condition: Unknown
Due 7 November 2000
Resolved 8 November 2000
Documentation
Issued 18 March 2000 Resolved
Prior to transfering fuel in U.S. Waters update Oil Transfer Procedures to include a description of each transfer system on the vsl IAW 33 CFR 155.750(a)(2) and provide in one manual.
Condition: Unknown
Due 18 March 2000
Resolved 18 March 2000
Documentation
Issued 18 March 2000 Resolved
Provide local contact phone numbers in SOPEP.
Condition: Unknown
Due 18 March 2000
Resolved 18 March 2000
Fire Fighting
Issued 9 December 1999 Resolved
Prior to next U.S. port, repair the malfunctioning indicators on fire screen doors #918,919,& 920._x001C_ SOLAS 74/78 II-2 Reg.30.4
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Lifesaving
Issued 9 December 1999 Resolved
Prior to next U.S. port, remove combustible materials from aft lift machinery room._x001C_ SOLAS 74/78 II-2 Reg.2.2.3
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Fire Fighting
Issued 9 December 1999 Resolved
Prior to next U.S. port, repair fire screen doors #411,515,909,& 923 which do not close completely._x001C_ SOLAS 74/78 II-2 Reg.30.4
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Accommodation/Occupational Safety
Issued 18 April 1999 Resolved
Remove pizza oven from Garden Cafeteria on Deck 11.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Accommodation/Occupational Safety
Issued 22 January 1999 Resolved
Prior to next boarding contact MOC/[name withheld] for guidance on verifying installation of oven in Garden Cafateria, deck 2.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Documentation
Issued 22 January 1999 Resolved
Provide current flag approved fire control plans to MOC for review.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Fire Fighting
Issued 28 November 1997 Resolved
Prove proper communications between the fire team and on scene leader. _x001C_ Note: Vessel has added radios to firefighter harness' to improve comms. Test at next fire drill.
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Documentation
Issued 28 November 1997 Resolved
Provide Class Society and MSC approved plans for Garden Cafeteria, deck 2, showing installation of ovens in public spaces. _x001C_ Note: Class has accepted arrangement. To confirm interpretation with MSC.
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Fire Fighting
Issued 28 November 1997 Resolved
Prove proper operation of the indicator light for fire screen door 429.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Documentation
Issued 28 November 1997 Resolved
Provide proof of USCG Marine Safety Center approval to comments in DNV letter dated June 25, 1997, in response to MSC letter dated June 16, 1997.
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Accommodation/Occupational Safety
Issued 28 November 1997 Resolved
Remove all storage above the false ceiling in space 309 located forward of fire screen door # A13 (deck 3)
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Documentation
Issued 28 November 1997 Resolved
Provide an operational limitations manual.
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Accommodation/Occupational Safety
Issued 28 November 1997 Resolved
Remove lockers from passageways in crew accommodations; decks 3,4, and 5. Note: Item pends. Class society requiring lockers to be upgraded to correct standards, or be removed.
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Fire Fighting
Issued 28 November 1997 Resolved
Install smoke detectors in all electrical lockers and storerooms.
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Accommodation/Occupational Safety
Issued 28 November 1997 Resolved
Remove suitcases and stores from housekeeping stores 6208 & 6207. At this time, housekeeping carts cannot be properly stored in rooms.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Fire Fighting
Issued 28 November 1997 Resolved
Install structural insulation (structural fire protection) behind low levellighting box in closet adjacent to fire screen door 914. (Typical for all low level lighting installation points). _x001C_ Note: Reported complete by class. check at next inspection.
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Lifesaving
Issued 28 November 1997 Resolved
Prove proper operation of low location lighting.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Fire Fighting
Issued 28 November 1997 Resolved
Install smoke detectors throughout cold storage rooms. At this time there are heat detectors in cold stores with very few smoke detectors. _x001C_
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Lifesaving
Issued 28 November 1997 Resolved
Provide a Bridge Radio Distress Panel.
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Documentation
Issued 28 November 1997 Resolved
Provide a U.S. Coast Guard Approved SAR plan.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Fire Fighting
Issued 28 November 1997 Resolved
Install smoke detectors in box rooms 8105A and 8105B.
Condition: Unknown
Due 28 November 1997
Resolved 28 November 1997
Fire Fighting
Issued 28 November 1997 Resolved
Effect repairs to fire screen door 1010.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Accommodation/Occupational Safety
Issued 28 November 1997 Resolved
Remove (2) mattresses in "Reeperbahn" #306 (deck 3).
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Fire Fighting
Issued 28 November 1997 Resolved
Repair smoke detector in fan room 12119.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Fire Fighting
Issued 28 November 1997 Resolved
Remove clothes hooks, etc. from fire hose locker 404C.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Engineering
Issued 16 April 1997 Resolved
REPAIR WATER LEAK ON OUTBOARD INCINERATOR BOILER PUMP.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Engineering
Issued 16 April 1997 Resolved
REPAIR FUEL OIL LEAK ON BUNKER LINE IN VICINITY OF BULKHEAD ADJACENT TO FIRESCREEN DOOR #302.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Accommodation/Occupational Safety
Issued 16 April 1997 Resolved
PERMANENTLY FIX DECK PLATE TO DECK IN VICINITY OF FIRE SCREEN DOOR #302.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Fire Fighting
Issued 17 October 1994 Resolved
UPDATED ONBOARD FIRE CONTROL PLAN TO REFLECT EXISTING STEAM SMOTHERING SYSTEMS FOR GALLEY, GARBAGE ROOM AND LAUNDRY.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Fire Fighting
Issued 17 October 1994 Resolved
MAKE PERMANENT REPAIRS TO FIRE SCREEN DOOR #814. PROVIDE WATCH PERSONNEL ATTHE DOOR WHEN EVER THE DOORS ARE OPERATED UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Lifesaving
Issued 17 October 1994 Resolved
REPLACE WORN LIFE-LINE BIGHTS ON OUTBOARD SIDE OF L/B #6.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Documentation
Issued 17 October 1994 Resolved
PROVIDE UPDATED LOADLINE CERTIFICATE REFLECTING THE C 1 MARK ON HULL.
Condition: Unknown
Due 17 October 1994
Resolved 17 October 1994
Navigation
Issued 26 April 1994 Resolved
VESSEL SPEED WAS IN EXCESS OF 12 KNOTS IN A REGULATED NAVIGATIONAL AREA. VESSEL WAS OPERATED IN A REGULATED NAVIGATION AREA CONTRARY TO THE REGULATIONS IN PRESCRIBED IN TITLE 33 C.F.R. 165.
Condition: Unknown
Due 26 April 1994
Resolved 2 May 1994
Navigation
Issued 26 April 1994 Resolved
VESSEL FAILED TO LEAVE LOS ANGELES APPROACH BOUY "LA" TO PORT. VESSEL WAS OPERATED IN A REGULATED NAVIGATION AREA CONTRARY TO THE REGULATIONS IN TITLE 33 C.F.R. 165.
Condition: Unknown
Due 26 April 1994
Resolved 2 May 1994
Fire Fighting
Issued 11 December 1989 Resolved
PROVE SATISFACTORY OPERATION OF FIRE DAMPERS 103, 106, 109 AND 114 PRIOR TOARRIVAL NEXT U.S. PORT.
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.