Records from 1988 to 2006. Most recent: inspection, 5 October 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
5 October 2006
Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2784205
13 July 2006
Initial Certification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2711952
15 June 2006
Hull Examination · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2681128
30 March 2005
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2323362
28 February 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1749546
28 March 2002
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1597692
4 April 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1062222
3 April 2001
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1397614
27 September 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 822327
28 April 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048902
10 March 1999
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1434841
28 December 1998
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 809200
30 September 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 214281
20 January 1998
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1388438
16 January 1997
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1424323
26 January 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1190784
25 January 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1190783
11 October 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1187007
24 July 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1191156
9 June 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 876243
6 October 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1175439
16 September 1994
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1471111
30 September 1993
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382648
21 December 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 826230
27 November 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1139013
8 October 1992
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1245469
3 October 1991
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937256
23 May 1991
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235480
13 November 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 927035
16 October 1990
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1237114
9 April 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 910006
2 February 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 930415
16 October 1989
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1352627
12 October 1988
Plan Review "T" Boat · COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1038027
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 June 2006
No resolution recorded
Provide seating plan prior to conducting simplified stability test to local OCMI.
Condition: Unknown
Due 11 September 2006 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing
Issued 28 February 2003
No resolution recorded
Prove compliance with the annual drug and alcohol program in accordance with 46 CFR 16.
Action required: 701 - Prior to carriage of passengers/cargo
Personnel › Certificates/Documents/Licenses
Issued 28 February 2003
No resolution recorded
Provide Red Cross First Aid/CPR cards for 50% of crew in accordance with NVIC 1-91.
Action required: 701 - Prior to carriage of passengers/cargo
Navigation › Piloting/Steering
Issued 28 February 2003
No resolution recorded
Provide navigation publications (current charts, US Coast Pilot, and Coast Guard Light List,) in accordance with 46 CFR 184.420.
Action required: 701 - Prior to carriage of passengers/cargo
Communications › Radio Communications
Issued 28 February 2003
No resolution recorded
Provide an emergency broadcast placard in accordance with 46 CFR 184.506.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Equipment Service/Testing
Issued 28 February 2003
No resolution recorded
Test EPIRB monthly and log results in accordance with 46 CFR 180.64. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Buoyant Apparatus
Issued 28 February 2003
Resolved
Stow lifefloat in a float free arrangement and so that the painter will pay out properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2003
Resolution: Corrected prior to completion of inspection.
Navigation › Piloting/Steering
Issued 28 March 2002
Resolved
The light required for night operation in inoperative. Provide working light for the magnetic compass in accordance with 46 CFR 184.402. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 28 March 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 28 March 2002
Resolved
The footstraps required for passengers riding on the sponsons were missing. Provide footstraps for passengers in accordance with MSO Honolulu CIDNOTE 22. LEGACY COMPONENT DESC: Footstraps
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2002
Resolved 28 March 2002
Lifesaving › Buoyant Apparatus
Issued 28 March 2002
Resolved
The waterlight required for the installed lifefloat was missing. Provide waterlight for lifefloat in accordance with 46 CFR 180.175(d). LEGACY COMPONENT DESC: Waterlight
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2002
Resolved 1 April 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 28 March 2002
Resolved
Found only 18 of 20 adult lifejackets required by COI. Provide 2 additional adult lifejackets in accordance with 46 CFR 180.71. Passenger count is limited to 16 until corrected. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 1 April 2002
Documentation › Markings/Placards
Issued 28 March 2002
Resolved
Vessel was missing the required lifejacket donning placard. Provide lifejacket donning procedures in accordance with 46 CFR 185.516. LEGACY COMPONENT DESC: Lifejacket Donning Procedures
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 1 April 2002
Lifesaving › Lifebuoys
Issued 28 March 2002
Resolved
Found the ring lifebuoy waterlight inoperative due to spent battery. Provide working waterlight for ring lifebuoy in accordance with 46 CFR 180.70. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2002
Resolved 1 April 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 28 March 2002
Resolved
Found unapproved fuel hoses in use in the fuel transfer system. Provide proper SAE J-1527 fuel hose (esp. from fuel filter to engine manifold), in accordance with 46 CFR 182.720. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 1 April 2002
Operations/Management › Drills/Instruction
Issued 28 March 2002
Resolved
Vessel is not currently in service carrying passengers. No drills have been documented in log. Conduct fire and man overboard drills in the presence of a Coast Guard inspector prior to operating with passengers in accordance with 46 CFR 185.520 and 185.524. LEGACY COMPONENT DESC: Fire and Man Overboard
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2002
Resolved 1 April 2002
Construction/Loadline › Hull
Issued 28 March 2002
Resolved
Found the valve for the "starboard #2" buoyancy chamber frozen in the closed position. Prove proper operation of starboard #2 bouyancy chamber valve in accordance with CIDNOTE 22. LEGACY COMPONENT DESC: Sponson Valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2002
Resolved 1 April 2002
Fire Fighting › Ventilation Systems
Issued 28 March 2002
Resolved
Found cracked and chipped vent closure housing. Make repair to starboard vent closure for engine compartment in accordance with 46 CFR 182.465. LEGACY COMPONENT DESC: Vent Closure
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 1 April 2002
Engineering › Steering Gear System
Issued 28 March 2002
Resolved
Vessel is not fitted with an auxiliary method of steering in event of failure of primary system. Demonstrate means of auxiliary steering in accordance with 46 CFR 182.620. LEGACY COMPONENT DESC: Auxiliary Steering Tiller
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 1 April 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 28 March 2002
Resolved
The vessel's pre-engineered fixed gas firefighting system is not provided with a means to manually actuate the system. Provide a means to manually actuate the fixed fire fighting system in accordance with 46 CFR 181.420(a)(2). LEGACY COMPONENT DESC: Operating Controls
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2002
Resolved 1 April 2002
Fire Fighting
Issued 3 April 2001
Resolved
Provide (3) 2 1/2 gallon fire buckets IAW 46 CFR 181.610.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 3 April 2001
Resolved
Mark lifejacket stowage IAW 46 CFR 185.604(f).
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 3 April 2001
Resolved
Provide footstraps for passengers riding on buoyancy pontoons IAW USCG MSO Honolulu CIDNOTE 22.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 24 July 1995
Resolved
PROVIDE BUOYANT APPARATUS FOR 10 PERSONS. UNTIL THIS IS PROVIDED YOU MAY ONLY CARRY 8 PASSENGERS AND 2 CREW. TO BE COMPLETED TO THE SATISFACTION OFTHE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 July 1995
Resolved 24 July 1995
Documentation
Issued 16 September 1994
Resolved
PROVIDE POLLUTION PREVENTION PLACARD.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Documentation
Issued 16 September 1994
Resolved
PROVIDE PROOF OF DRUG TESTING POLICY IN ACCORDANCE WITH 46 CFR 16.250, 16.240. TO BE PROVIDED PRIOR TO 23SEP94.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Lifesaving
Issued 16 September 1994
Resolved
PROVIDE PROOF OF TWO LIFE PRESERVERS. VESSEL IS RESTRICTED TO 18 TOTAL PERSONS UNTIL IN COMPLIANCE.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Lifesaving
Issued 16 September 1994
Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Lifesaving
Issued 16 September 1994
Resolved
PROVIDE TWO PADDLES FOR LIFE FLOAT IN ACCORDANCE WITH 46 CFR 180.15-1(a).
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Lifesaving
Issued 16 September 1994
Resolved
PERMANENTLY MARK TOTAL PERSONS ALLOWED ON THE LIFE FLOAT IN ACCORDANCE WITH46 CFR 185.30-5(b).
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Lifesaving
Issued 16 September 1994
Resolved
PERMANENTLY MARK LOCATION OF LIFE PRESERVERS IN ACCORDANCE WITH 46 CFR 180.25-15(b).
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Fire Fighting
Issued 16 September 1994
Resolved
PROVIDE PROOF OF SERVICING ONE B-II FIRE EXTINGUISHER IN ACCORDANCE WITH 46CFR 176.30-1(a).
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Documentation
Issued 8 October 1992
Resolved
PROVIDE A CURRENT COPY OF FCC RADIO OPERATORS PERMIT.
Condition: Unknown
Due 8 October 1992
Resolved 8 October 1992
Documentation
Issued 8 October 1992
Resolved
PROVIDE PROOF OF COMPLIANCE WITH MANDATORY RANDOM DRUG TETSING REQUIREMENTS.
Condition: Unknown
Due 8 October 1992
Resolved 8 October 1992
Engineering
Issued 16 October 1990
Resolved
INSTALL A METAL HEAT DEFLECTOR SHIELD ON THE RACOR FUEL FILTER OR REPLACE IT WITH AN ACCEPTED TYPE.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Engineering
Issued 12 October 1988
Resolved
PROVIDE CALCULATIONS DEMONSTRATING THE STRENGTH OF INDEPENDENT FUEL TANKS AS DETAILED IN MSO HONOLULU LETTER 16715/13 OF 07OCT88 BY 01JUN89, OR REPLACE BOTH TANKS WITH COAST GUARD APPROVED FUEL TANKS AS PER REFERENCED LETTER.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Fire Fighting
Issued 12 October 1988
Resolved
PROVIDE ONE USCG TYPE/SIZE B-II PORTABLE FIRE EXTINGUISHER ON THE VESSEL. (ADMINISTRATIVELY ISSUED).
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Documentation
Issued 12 October 1988
Resolved
PROVIDE COPY OF AND PLACE ON BOARD VESSSSSEL, CURRENT FCC 824, SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Engineering
Issued 12 October 1988
Resolved
INSTALL REMOTE FUEL SHUT OFF VALVES FOR 2 INSTALLED INDEPENDENT TANKS.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988