MAURY USCG vessel records Sign in
← All vessels

JO EBONY

JO EBONY is a 1986 tank ship. The Coast Guard has recorded 43 inspections since 1988, most recently in December 2007, along with 22 deficiencies and 4 operational controls.

Records from 1988 to 2007. Most recent: inspection, 12 December 2007.

Built
1986
Last inspected
12 December 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8500135 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
322650
Flag
LIBERIA
—
Maury page id
psix-322650

Inspections, by type

…with no type recorded31
Years with a record 13 calendar years (1988–2007)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4072 - Regulatory (Subpart C or D), Net Ton
12152 - Dead Weight, Ton
7915 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 43

12 December 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3111953
20 June 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2968136
14 June 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2961416
10 May 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2927004
1 April 2007 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2899200
19 July 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2718345
13 May 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2648924
6 April 2006 Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 2618654
11 March 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2600350
9 March 2006 Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2599565
9 December 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2565744
11 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2460821
18 April 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2336184
24 March 2005 COC-CHEM Renew · ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2315718
10 November 2002 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1703806
3 October 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 294357
28 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294264
26 September 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 294045
26 September 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1077123
29 May 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 429152
29 May 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 801324
24 May 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 487362
3 December 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 362751
2 December 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 3640
16 August 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 439977
29 July 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1373893
10 February 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 531160
6 February 1993 MARPOL Annex I Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827847
28 April 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1267159
6 December 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 347511
2 December 1991 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 540446
26 November 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006721
10 September 1991 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 933825
28 December 1990 Certificate of Compliance
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 919353
13 June 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 337687
28 May 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 337374
16 February 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 335337
15 February 1990 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 924285
26 July 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 331673
4 June 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 479317
5 April 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 329540
26 December 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 327554
26 December 1988 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039211

Deficiency record · 22

Operations/Management › Cargo Transfer/Lightering › Use of Vapor Control System
Issued 24 March 2005 Resolved
Provide Class Society documentation detailing what cargos are permitted to be transferred using the vapor collection system (proper cargo names).
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 18 April 2005
Resolution: CLEARED VIA CLASS REPORT
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Electric Bonding
Issued 24 March 2005 Resolved
Connect broken ground wires on various flanges in cargo block (1C, 5's) manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 25 March 2005
Resolution: Broken ground wires repaired/corrected.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 24 March 2005 Resolved
Make Flame screens tight for fuel oil vents iwo port side of aft house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 25 March 2005
Resolution: Flame screens tightened/corrected to satisfaction of attending CG Marine Inspector.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 24 March 2005 Resolved
Renew gaskets on three (3) Class A doors around galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 25 March 2005
Resolution: Gaskets around Class A doors replaced.
Documentation › Manuals/Policy Documentation › Tank Vessel Loading Information
Issued 24 March 2005 Resolved
Document that PIC has been trained per 46 CFR 39.10-11 for Vapor Control System.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 25 March 2005
Resolution: Documentation provided.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 24 March 2005 Resolved
Provide cross-reference index for cargo transfer procedures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 25 March 2005
Resolution: Cross reference index provided.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 24 March 2005 Resolved
Provide documented proof of 46CFR 39.20-13 testing & results of vapor piping in vapor pressure system. Identify if system maintenance & testing frequencies are specified by company SMS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 18 April 2005
Resolution: CLEARED VIA CLASS REPORT
Lifesaving › Lifeboat › Propulsion Engine
Issued 24 March 2005 Resolved
Port lifeboat overheated with in 15 minutes of being in water. Vessel must make necessary re[pairs to engine enabling lifeboat to comply with SOLAS Regulations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 25 March 2005
Resolution: Deficiency rectified.
Deck/Cargo
Issued 26 September 2001 Resolved
MARK ALL CARGO HOSES IAW 33 CFR 154.500(e)(3) and (f)(1), PRIOR TO USE IN THE U.S. 33 CFR 155.800
Condition: Unknown
Due 3 October 2001
Resolved 3 October 2001
Deck/Cargo
Issued 26 September 2001 Resolved
PERMANENTLY INSTALL VAPOR LINE STUD IAW 46 CFR 39.20-1(e) PRIOR TO CONDUCTING CLOSED LOADING OPERATIONS IN THE U.S.
Condition: Unknown
Due 3 October 2001
Resolved 3 October 2001
Fire Fighting
Issued 26 September 2001 Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS PROVIDE CURRENT FOAM ANALYSIS.
Condition: Unknown
Due 26 September 2001
Resolved 28 September 2001
Deck/Cargo
Issued 26 September 2001 Resolved
PROVIDE TWO SETS OF 6", 8", AND 10" REDUCERS IAW 33 CFR 157.410.
Condition: Unknown
Due 26 October 2001
Resolved 10 November 2002
Resolution: Sited reducers onboard vessel.
Lifesaving
Issued 26 September 2001 Resolved
REPAIR LOW WATER PRESSURE TO EMERGENCY SHOWER STATIONS ON DECK._x001C_ BCH CODE 3.16.12
Condition: Unknown
Due 26 December 2001
Resolved 10 November 2002
Resolution: Witnessed proper operation.
Fire Fighting
Issued 29 May 1999 Resolved
INEFFECTIVE FOAM FOR CARGO FIRE FIGHTING._x001C_ (IBC 11.3.2 AND 17 COLUMN l)
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Deck/Cargo
Issued 29 May 1999 Resolved
VCS PRESSURE ALARM INOPERATIVE._x001C_ (46 CFR 39)
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Documentation
Issued 16 February 1990 Resolved
CARGO RECORD BOOK WAS NOT SIGNED AFTER EACH ENTRY AS REQUIRED BY 46 CFR 155.909(C).
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Navigation
Issued 5 April 1989 Resolved
VESSEL HAD A BRITISH ADMIRALTY EDITION OF THE COAST PILOT ON BOARD NOT CORRCETED UP TO DATE.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Deck/Cargo
Issued 26 December 1988 Resolved
VESSEL CARRYING AN NLS CARGO (FATTY ALCOHOL) WITHOUT THE INFORMATION REQUI-RED BY THE SPECIAL REQUIREMENTS IN 46 CFR 153 TABLE 1.
Condition: Unknown
Due 26 December 1988
Resolved 26 December 1988
Navigation
Issued 26 December 1988 Resolved
BRITISH ADMIRALTY CHARTS 2755 (23NOV84) AND 3204 (15JUN84) NOT PROPERLY CORRECTED UP TO DATE THROUGH THE LATEST NOTICE TO MARINERS.
Condition: Unknown
Due 26 December 1988
Resolved 26 December 1988
Navigation
Issued 26 December 1988 Resolved
VESSEL HAD A 1985 EDITION OF THE BRITISH ADMIRALTY LIGHT LIST ON BOARD NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 26 December 1988
Resolved 26 December 1988
Deck/Cargo
Issued 26 December 1988 Resolved
VESSEL HAD NOT CONDUCTED A STATIC LIQUID PRESSURE TEST SINCE BEING BUILTED.
Condition: Unknown
Due 26 December 1988
Resolved 26 December 1988
Navigation
Issued 26 December 1988 Resolved
VESSEL HAD A 1988 VOL 2 COAST PILOT ON BOARD NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 26 December 1988
Resolved 26 December 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.