MAURY USCG vessel records Sign in
← All vessels

LAND ANGEL

LAND ANGEL is a 1987 tank ship. The Coast Guard has recorded 42 inspections since 1989, most recently in April 2018, along with 32 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1989 to 2018. Most recent: inspection, 16 April 2018.

Built
1987
Last inspected
16 April 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8600791 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
322920
Flag
CHINA
—
Maury page id
psix-322920

Inspections, by type

…with no type recorded30
…past their stated due date1
Years with a record 14 calendar years (1989–2018)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it68746 - Dead Weight, Ton
39314 - Convention (Subpart B), Gross Ton
17516 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 42

16 April 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6392874
7 March 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 287905
29 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 279407
5 January 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 273426
17 May 1999 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 428097
30 November 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 423492
30 November 1998 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404663
8 March 1998 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 531072
5 March 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788557
4 March 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 19805
27 November 1997 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1409792
26 November 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 410235
11 March 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 522755
11 October 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 396435
9 August 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 393975
10 July 1996 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 393156
17 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 390272
13 October 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1190299
12 October 1995 Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1188835
10 June 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 466992
15 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 372479
15 November 1994 Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 865416
14 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 137398
14 March 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 365181
23 November 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 362610
23 November 1993 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1399940
25 September 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 361015
25 September 1993 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1153832
13 December 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 532263
18 May 1992 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 943113
13 April 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 350106
13 April 1992 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1263298
13 February 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 135421
10 March 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 342407
10 March 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937620
4 February 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 335305
4 February 1990 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 907517
30 October 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 333372
22 September 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 462985
9 August 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 505612
30 January 1989 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1208765
28 January 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 460477

Deficiency record · 32

Deck/Cargo
Issued 7 March 2001 No resolution recorded
Pump room not gas-freed. Gas free and make ready for USCG inspection the cargo pump room not later than 21MAR01.
Condition: Unknown
Due 21 March 2001 — due date passed with no resolution recorded
Lifesaving
Issued 11 October 1996 Resolved
lifeboat limit switches were inoperable. SOLAS 74 Chapter III Reg. 48.2.5._x001C_
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Deck/Cargo
Issued 10 July 1996 Resolved
Make permanent repair to deck water seal drain pipe that has a temporary soft patch, as required by China Classification Society report of survey dated 10JUL96.
Condition: Unknown
Due 11 August 1996
Resolved 11 August 1996
Deck/Cargo
Issued 10 July 1996 Resolved
At next U.S. port of call and prior to cargo operations, demonstrate that both IGS blowers can properly operate in accordance with operation manual. Computer card E-41 on No. 2 blower is sensing that the flute air cocks are not open and will not allow the blower to go to a run mode.
Condition: Unknown
Due 11 August 1996
Resolved 11 August 1996
Deck/Cargo
Issued 13 October 1995 Resolved
Make a permanent repair to the deck water seal heating coil trunk area.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Engineering
Issued 13 October 1995 Resolved
Make a permanent repair to the auxiliary generator heat exchanger as outlined in Det Norske Veritas survey report dated 13OCT95.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Lifesaving
Issued 13 October 1995 Resolved
Make permanent repair to step going into the bow bosun hold hatch as outlined in DNV classification society survey report dated 13OCT95.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Deck/Cargo
Issued 12 October 1995 Resolved
Prior to next discharge of cargo in an U.S. port, provide mechanical closing plugs for aft main deck scuppers.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Lifesaving
Issued 12 October 1995 Resolved
Prior to next U.S. port of call, demonstrate that the port liferaft can be wheeled to the starboard side of the vessel (one wheel is currently broken).
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Electrical
Issued 12 October 1995 Resolved
Prior to next U.S. port of call, demonstrate that the vessel is in compliance with classification societies recommendations on the ballast pump circuit breaker overheating problem which is requiring additional cooling to maintain system on line.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Fire Fighting
Issued 12 October 1995 Resolved
Prior to next U.S. port of call, demonstrate that the aft lower engineroom emergency escape door will properly self close.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Fire Fighting
Issued 12 October 1995 Resolved
Prior to next U.S. port of call, demonstrate that the engineroom door into the starboard main deck passageway will self close.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Deck/Cargo
Issued 12 October 1995 Resolved
Prior to next cargo operation in the United States, make a proper repair tothe deck water seal unit in accordance with classification society recommendations.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Lifesaving
Issued 12 October 1995 Resolved
Prior to departure from San Francisco Bay, demonstrate proper operation of starboard lifeboat rudder.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Engineering
Issued 12 October 1995 Resolved
Prior to bunkering operations in the U.S., install mechanical plugs for theport and starboard buker line containment box.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Lifesaving
Issued 12 October 1995 Resolved
Prior to next U.S. port of call, make proper repair to the step going into the bow bosun hold hatch.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Fire Fighting
Issued 12 October 1995 Resolved
Prior to next U.S. port of call, renew clamp on emergecny fire pump priminghose.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Deck/Cargo
Issued 12 October 1995 Resolved
Prior to next U.S. port of call, renew battery in O2 meter and demonstrate proper operation upon boarding.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Engineering
Issued 12 October 1995 Resolved
Have vessels classification society visit and make recommendations on generator heat exchanger pipe repair.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Deck/Cargo
Issued 25 September 1993 Resolved
Verify ventilation design of cargo pumproom--port ventilation fan is labeled exhaust, but is acting as supply. Reverse direction of port forcedventilation to comply with design standard. Provide report from class society to [name withheld], Texas prior to next U.S. port._x001C_
Condition: Unknown
Due 25 September 1993
Resolved 25 September 1993
Engineering
Issued 25 September 1993 Resolved
Replace bunker and lube oil vent flame screens with 30x30 mesh screens prior to next U.S. Port.
Condition: Unknown
Due 25 September 1993
Resolved 25 September 1993
Construction/Loadline
Issued 13 April 1992 Resolved
INSTALL FLAME SCREENS ON BALLAST TANK VENTS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 13 April 1992
Resolved 13 April 1992
Electrical
Issued 13 April 1992 Resolved
DEMONSTRATE PROPER OPERATION OF THE EMERGENCY GENERATOR AUTOMATIC START ANDAUTOMATIC LOAD TRANSFER PRIOR TO NEXT U.S. PORT (REQUIRED BY SOLAS CH. II-1REG 43, 3.1.2)._x001C_
Condition: Unknown
Due 13 April 1992
Resolved 13 April 1992
Deck/Cargo
Issued 13 April 1992 Resolved
CONDUCT PRESSURE TEST OF CARGO PIPING TO 225 PSI NO LATER THAN NEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 13 April 1992
Resolved 13 April 1992
Navigation
Issued 10 March 1991 Resolved
CHARTS 12326(ED39) AND 12327(ED82) NOT CORRECTED UP TO DATE THROUGH THE LATEST NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33(A)(1)(II)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Navigation
Issued 10 March 1991 Resolved
VESSEL'S ARPA LABLE NOT DISPLAYED ON UNIT AS REQUIRED BY 33 CFR 164.38(D)(2)(II)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Documentation
Issued 10 March 1991 Resolved
VESSEL'S CARGO OIL TRANSFER PROCEDURES DID NOT MEET THE REQUIREMENTS OF 33 CFR 155.750_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Navigation
Issued 10 March 1991 Resolved
VESSEL'S COAST PILOT FOR THE AREA TO BE TRANSITED WAS NOT CURRENTLY CORRECTED AS REQUIRED BY 33 CFR 164.33(A)(2)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Navigation
Issued 10 March 1991 Resolved
VESSEL FAILED TO PROPERLY CONDUCT AND LOG PRE-ARRIVAL TEST 33 CFR 164.25(A)AS REQUIRED BY 33 CFR 164.11(Q)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Navigation
Issued 10 March 1991 Resolved
VESSEL FAILED TO LOG THE EMERGENCY STEERING DRILL WITHIN 48 HOURS PRIOR TO ENTERING PORT AS REQUIRED BY 33 CFR 164.25(D)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Navigation
Issued 10 March 1991 Resolved
OPERATING INSTRUCTIONS AND A BLOCK DIAGRAM SHOWING STEERING CHANGE OVER PROCEDURES FOR THE REMOTE STEERING CONTROL WEREN'T DISPLAYED ON THE BRIDGE AS REQUIRED BY 33 CFR 164.35(K)_x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Deck/Cargo
Issued 10 March 1991 Resolved
PROVE PROPER OPERATION OF IGS SYSTEM PRIOR TO THE CARRIAGE OF GRADES AND ABOVE CARGOES, TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 10 March 1991
Resolved 10 March 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.