MAURY USCG vessel records Sign in
← All vessels

OCEAN GLORY

OCEAN GLORY is a 2001 freight ship. The Coast Guard has recorded 11 inspections since 2002, most recently in March 2009, along with 4 deficiencies and 2 operational controls.

Records from 2002 to 2009. Most recent: inspection, 18 March 2009.

Built
2001
Last inspected
18 March 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9227637 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-32296

Inspections, by type

…with no type recorded3
Years with a record 5 calendar years (2002–2009)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it27575 - Convention (Subpart B), Gross Ton
16641 - Convention (Subpart B), Net Ton
48437 - Dead Weight, Ton
56178 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

18 March 2009 MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3433579
12 September 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3323340
3 March 2008 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3150448
26 December 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3122358
19 December 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3118281
10 October 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3077207
24 May 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2932444
20 February 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2874346
4 February 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1740184
3 February 2003 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1737694
27 April 2002 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1606483

Deficiency record · 4

Fire Fighting › Firemans Outfit › Lifeline
Issued 20 February 2007 Resolved
Fireproof lifeline on firefighter's outfit was not attached correctly. SOLAS 2001, Ch.II-2, Reg. 17.2
Action required: 705 - Other - as specified
Resolved 20 February 2007
Operations/Management › Drills/Instruction › Fire
Issued 20 February 2007 Resolved
During fire drill, fire damper ventilation was not secured. SOLAS 2004, Reg. 19.2.4.2.5 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 May 2007
Resolution: Received proper documentation from vessel''s master satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 February 2003 Resolved
Prove proper operation of oil-water separating equipment and waste oil incinerator to the satisfaction of attending class surveyor, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2003
Resolution: Oil-water separating equipment was repaired to the satisfaction of class.
Navigation › Piloting/Steering
Issued 27 April 2002 Resolved
Provide currently corrected charts and light list and coast pilot for areas to be transited while in U. S. This item to be corrected prior to departure from port. 33 CFR 164.33 LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2002
Resolution: Rcvd receipts by fax from master for required charts and publications.