MERIDIAN NAVIGATOR is a 1984 freight ship. The Coast Guard has recorded 33 inspections since 1989, most recently in March 2008, along with 17 deficiencies and 6 operational controls, 1 with no removal date recorded.

Records from 1989 to 2008. Most recent: inspection, 7 March 2008.

Built
1984
Last inspected
7 March 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8307492 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
322972
Flag
HONG KONG
—
Maury page id
psix-322972

Inspections, by type

…with no type recorded22
Years with a record 14 calendar years (1989–2008)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it12311 - Convention (Subpart B), Net Ton
33024 - Dead Weight, Ton
39715 - Displacement, Ton
19340 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

7 March 2008 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3160199
5 March 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3159280
5 March 2008 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3159505
12 February 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3146434
9 February 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3139829
26 July 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3008460
11 June 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2958108
9 June 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2955832
9 June 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2958268
27 May 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2941724
10 October 2005 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2511339
22 September 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2498619
21 September 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2502255
21 September 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2502442
13 June 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2390149
4 April 2005 Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2325972
16 February 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2293598
21 August 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2172300
7 August 2004 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2153840
24 February 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2012438
4 April 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 288796
15 February 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 274616
4 November 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 422086
21 July 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 418492
23 September 1997 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 407677
18 April 1996 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 390037
27 June 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 367894
25 February 1994 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 365225
14 November 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 354491
28 July 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 352104
9 September 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 345714
6 April 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 336060
11 March 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 328951

Deficiency record · 17

Engineering › Compressed Air System (control) › Piping
Issued 7 March 2008 Resolved
Vessel reported a loss of propulsion due to loss of control air to the main engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 7 March 2008
Resolution: Received report from the certificate issuing authority that the control air tubing and in-line filters were opened , cleaned and blown through. The vessels machinery was tested ans is fully operational and remains in class.
Engineering › Compressed Air System (control) › Piping
Issued 11 June 2007 Resolved
The vessel experienced a M/E power failure due to a failure of the signal from the bridge maneuvering station to the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2007
Resolved 11 June 2007
Resolution: Rcvd class report from BV satisfying requirement. Inspection of the M/E control failure was carried out and it was found that a filter inside the housing of the maneuvering unit was partially clogged it was changed and engine was tested w/ sat results.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 22 September 2005 Resolved
Marine Sanitation Device is inoperable. Vessel not able to remove liquids or solids from the retention tank. Sewage is currently being diverted to an aft tank in the steering gear room. Vessel has reported the condition to the company.
Action required: 705 - Other - as specified
Due 22 October 2005
Resolved 8 October 2005
Resolution: Received e-mail from captain of the vessel stating that the MSD had been repaired and repairs approved by class surveyor.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 22 September 2005 Resolved
Vessel's incinerator used to burn oily sludge / waste is inoperable. Repair to the satisfaction of class society to retain the validity of the IOPP certificate which requires an operable incinerator with 17.00 l/h capacity.
Action required: 705 - Other - as specified
Due 22 October 2005
Resolved 8 October 2005
Resolution: Received e-mail from captain of the vessel stating that incinerator has been inspected by a class surveyor and an interim IOPP has been issued.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 22 September 2005 Resolved
Mixed garbage found on vessel including plastic mixed with food waste. Garbage management plan is vague, and must include procedures for collecting, storing, processing and disposing of garbage, including the use of equipment on board. Update plan as per MARPOL requirements. Crew corrected mixed garbage onboard prior to USCG departure.
Action required: 705 - Other - as specified
Due 22 October 2005
Resolved 8 October 2005
Resolution: Received e-mail from the captain of the vessel stating that a revised and updated garbage management plan has been received and is being implemented by the crew.
Engineering › Diesel Engine (propulsion-direct drive) › Piston Ring
Issued 21 September 2005 Resolved
6 broken piston rings, 4 in cyclinder #1 and 2 in cyclinder #6. SOLAS 2004 Chapter II-1 Reg. 26.3. Correct to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2005
Resolution: 24-Sept-2005 - Received Class report attesting to repairs made to the #1 and #6 cyclinder piston rings.
Engineering › Diesel Engine (propulsion-direct drive) › Piston
Issued 14 June 2005 Resolved
01 piston inoperable; SOLAS 74 Am I/ 11; Provide attestation from class.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2005
Resolved 17 June 2005
Resolution: Received class report verifying repairs made to the piston on the main engine.
Fire Fighting
Issued 15 February 2000 Resolved
Correct exaust leaks on emergency fire pump and emergency fire pump exaust piping._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 16 April 2000
Resolved 28 February 2000
Construction/Loadline
Issued 15 February 2000 Resolved
Make permanent repairs to suction side of #3 ballast pump were soft patch exists._x001C_ _x001C_ SOLAS 74(A) II-2/4
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 15 February 2000 Resolved
Class attest to proper operation of port lifeboat davit recovery system.
Condition: Unknown
Due 16 February 2000
Resolved 28 February 2000
Lifesaving
Issued 15 February 2000 Resolved
Correct exaust leak on starboard lifeboat.
Condition: Unknown
Due 16 February 2000
Resolved 28 February 2000
Accommodation/Occupational Safety
Issued 15 February 2000 Resolved
Class to attend vessel and recommend repairs to sewage overboard pipe wheresoftpatches exist between checkvalve and hull below the waterline._x001C_ _x001C_ ILLC 66
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Accommodation/Occupational Safety
Issued 15 February 2000 Resolved
Class to attest to adequacy of all weathertight doors on superstructure._x001C_ _x001C_ ILO147
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 15 February 2000 Resolved
Replace rotten wood to the satisfaction of class in port lifeboat._x001C_ _x001C_ SOLAS 74(A) III- 19.2
Condition: Unknown
Due 16 February 2000
Resolved 28 February 2000
Navigation
Issued 23 September 1997 Resolved
SOLAS 74 REG II-1/29.11: Correct 4-to-5-degree discrepancy between bridge and after steering rudder angle indicators.
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Fire Fighting
Issued 23 September 1997 Resolved
SOLAS 74, REG 18: Conduct satisfactory fire/abandon ship drills prior to departure from Searsport, ME.
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Construction/Loadline
Issued 23 September 1997 Resolved
ILLC 66, ANNEX I/12: Make repairs to superstructure watertight doors, including channels (gasket coaming)/dogs/gaskets, to satisfaction of class society.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998

Ownership record