Records from 2009 to 2026. Most recent: inspection, 5 August 2026.
Inspection history · 36
5 August 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8456649
21 July 2026
Vessel Attendance
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8443438
18 March 2026
Administrative Inspection · MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8304858
22 September 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8238733
26 February 2025
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8084823
26 January 2025
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8069893
26 January 2025
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8085013
23 December 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8050399
18 December 2024
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8083821
13 December 2024
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8047287
2 December 2024
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8041911
2 June 2024
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7924926
13 March 2024
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7877676
28 February 2024
Plan Review (Other than "T") · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7871503
17 January 2024
Hull Examination · Deficiency Check · Internal Structural Exam · Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7847076
18 August 2023
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7771369
15 May 2023
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7688774
8 March 2023
Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7646378
15 September 2022
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7548894
26 January 2022
MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7371605
24 March 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7162278
4 March 2020
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6919546
10 August 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6791301
12 July 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6747373
3 May 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6606985
1 May 2019
Annual Inspection · Deficiency Check · Administrative Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6674551
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505609
28 February 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6362757
19 November 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6350801
13 November 2017
Plan Review (Other than "T")
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6316497
9 August 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6235016
19 June 2017
Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6180767
17 June 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6194105
13 June 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6294988
31 January 2017
Administrative Inspection · COI Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6080555
16 February 2016
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5834199
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 18 March 2026
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159. MI observed a small pinhole in the main sanitation pipe that allowed residual sewage in bilge. Operator is to supply a repair proposal to OCMI, if a temporary repair clamp is used the Operator shall ensure a permanent repair is proposed prior to next drydock. Permanent repair shall be made in sufficient time with approved proposal, final inspection of pipe shall be made to satisfaction of attending MI. Vessel shall not carry passengers until a temp repair has been completed iaw the OCMI approved repair proposal.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2026
Resolution: Temp repairs were made.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2026
Resolved
A vessel more than 65 feet in length must carry a minimum of 3 ife buoys, each life buoy must follow; iaw Sub-chapter Q 160,050; line around life buoy must not be permanently attached and a corrosion resistant clip around waterlight attached to life buoy. MI noticed 01 life ring buoy with waterlight did not have lanyard attached with corrosion resistant clip. Operator is to make repairs to life buoy to satisfaction of MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 20 March 2026
Resolution: Corrosion resistant clip was added to life ring.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 March 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: provide services necessary for safety under normal and emergency conditions: MI observed equipment in the lazarette space that is no longer being used. Operator is to remove or tag out equipment in space to comply with regs.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 31 March 2026
Resolution: Received phots of compressor removed from space
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 March 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect crew, other persons, and the vessel from electrical hazards. MI observed that a receptacle was not attached to bulkhead and free-floating in the lazarette space. Operator shall attach receptacle to ensure it is not free-floating to satisfaction of MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 31 March 2026
Resolution: Removed outlet completely.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 March 2026
Resolved
New installations of fire protection equipment on an existing vessel, which are completed to the satisfaction of the OCMI on or after March 11, 1996 must comply with regulations of this part. Vessel had new fire-fighting panel and equipment installed. The new fire panel was tested and operational. MI observed the old fire alarm in pilothouse still had power. Operator shall remove or secure and tag-out the old fire panel to satisfaction on attending MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 6 April 2026
Resolution: Verified fire detection from old alarm was removed and met satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 January 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of hull in which it is installed and capable of operating at constant marine load; Port engine starved of fuel, causing temporary loss of power/ propulsion. Vessel restricted prior to movement pending attendance from marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 January 2025
Resolution: Verified operational propulsion system, cleared def accordingly.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 December 2024
Resolved
(a) Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable.
Vessel had moving blankets stuffed into the ventilation of the steering room and other compartments to keep the spaces warm so the pipes didn't freeze. When the blanket fell or was placed on the exhaust by a contractor from a previous installation, the hot dry exhaust pipe caught the blanket fire.
Vessel is restricted prior to movement until a damage survey can be completed by the attending marine inspector.
46 CFR 116.405 (a)
60C
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 December 2024
Resolution: No major damage was found
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 December 2024
Resolved
(b) At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes.
MI observed excessive 5 gallon buckets of oil and excessive # of oil absorbent pads in the engine room.
Vessel is restricted prior to movement until the fire hazards have been removed.
46 CFR 115.830 (b)
60C
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 December 2024
Resolution: Oil and absorbents were removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 February 2024
Resolved
Provide approval letter from Marine Safety Center for Fixed Fire Detection System.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 28 February 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 February 2024
Resolved
Provide approval letter from Marine Safety Center for Fire Detection System.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 28 February 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 January 2024
Resolved
Grind out clad weld in bow thruster tunnel. Provide UT shots on the ring.
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: UT shots were acceptable. Installed new stainless steel sacrificial ring in bow thruster tunnel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 August 2023
Resolved
Auxiliary machinery. All machinery necessary to the routine operation of the vessel shall be checked. The stbd generator lube oil pressure switch was leaking oil. Vessel is to operate on the port generator only until the switch can be renewed. In the event it becomes necessary to operate the stbd generator the master shall notify the CG Sec Del Bay Command Center immediately.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2023
Resolved 23 August 2023
Resolution: Switch was renewed. Operational test witnessed, all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 March 2023
Resolved
The marine employer shall ensure that all individuals engaged or employed on board a vessel are fully indoctrinated in the requirements of this subpart, and that appropriate vessel personnel are trained as necessary in the practical applications of these requirements. Vsl recently transitioned to a new consortium for their DAPI program but was unable to provide enrolment documentation. Vsl was able to provide us the MIS report from 2021 and are waiting for the 2022 report. New consortium started February 01 2023.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2023
Resolved 7 April 2023
Resolution: Conducted DAPI audit IAW Chemical Testing Program Compliance Audit form, vsl was found in compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 March 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Notice unauthorized power strip surge protector was being utilized in the pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 17 March 2023
Resolution: Vsl provided objective evidence of an approved receptacle outlet installed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 8 March 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 degrees F must be insulated where necessary to prevent injuries. Lagging on the Port engine and the STBD generator are deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 17 March 2023
Resolution: Vsl provided objective evidence of areas where lagging was addressed with heat resistant wrap. Vsl ordered new blankets and flange covers, invoice provided as objective evidence as well.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 March 2023
Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. Cable and wire run in the galley penetrating the ceiling does not prevent the passage of flame or smoke.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 17 March 2023
Resolution: Vsl provided objective evidence of approved fire stop putty and sealant from STI Marine was used.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 March 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Various first aid kits had expired contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 17 March 2023
Resolution: Vsl provided objective evidence of discarding expired items in the first aid kit and replacing with in kind.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 March 2023
Resolved
A door in a bulkhead required to be A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead. Noticed that the double swinging doors from the galley (A-Class boundary) into a accommodation space was not a rated boundary door that was noted in Vessels structural fire protection plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2023
Resolved 30 November 2023
Resolution: Attend vessel and witnessed proper install and operation of new A-15 fire doors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2022
Resolved
No major repairs or alterations shall be made without the knowledge and approval of the [name withheld] thruster's rudder feedback linkage had rope lashing to prevent the worn ball joint from disconnecting. Replace worn ball joint. 46 CFR 176.20-1(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2022
Resolved 2 February 2022
Resolution: Replaced in kind, video sent showing full range working range with no issues.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 January 2022
Resolved
at re inspection the marine inspector shall require that all unsafe practices and hazardous situations be corrected. Exhaust hood above the dish washer had excessive accumulation. Clean ventilation above dishwater. 46 CFR 176.25-50.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2022
Resolved 31 January 2022
Resolution: Exhaust hood cleaned
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2021
Resolved
02 light fixtures in pilothouse have exposed lamps. Provide suitable lens for fixture or alternatively replace fixture if lens is not available.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 25 May 2021
Resolution: Lens provided and fitted for each fixture.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 May 2021
Resolved
Life buoy was found with wasted grab lines. Replace in kind with life buoy approved under 160.050.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 25 May 2021
Resolution: Life buoy replaced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 May 2021
Resolved
Fire detection system requires servicing. Have fire panel inspected and serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 11 June 2021
Resolution: 01 detector replaced and 01 end of line resistor replaced. Attending inspector witnessed full function of system.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 7 May 2021
Resolved
Galley fans and vents require cleaning of foreign matter for cleanliness and fire hazard. Clean fans and vents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 25 May 2021
Resolution: Vents and fans cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 7 May 2021
Resolved
Tank space exit is not labeled. Label on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 25 May 2021
Resolution: Labeling put in place.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: Incorrect NAME.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 November 2018
Resolution: AIS information updated.
Engineering › Pressure Vessel › Relief Valve
Issued 28 February 2018
Resolved
Make air reciever available for hydrostatic testing and make arrangements for testing of air relief valve to the satisfaction of attending marine inspector. 46 CFR "Old T" 182.10-5(d)
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 19 March 2018
Resolution: Air receiver had satisfactory internal inspection in 2015 by USCG MI, hydro not required. New relief valve installed, witness operation, lifted at 136 psi.
Engineering › Fuel Oil Service System › Hose
Issued 28 February 2018
Resolved
Install chaffe gear on main engine flex hose as discussed. Replace damaged flex hose on starboard engine. 46 CFR 115.800(a)
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 19 March 2018
Resolution: New hoses (J1942) installed and chaffe gear installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 28 February 2018
Resolved
Investigate location of exhaust leak in muffler void and repair as necessary. 46 CFR "Old T" 182 20-20
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 3 May 2019
Resolution: Exhaust muffler replaced during drydock. Witnessed operation underway. All sat.
Electrical › Electric Supply System (service) › Cable
Issued 19 June 2017
Resolved
EKO01: Submit electrical load analysis for port and starboard generators for review by USCG Marine Inspector. Prior to Carrying Passengers Underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 10 July 2017
Resolution: Cleared in Person by [name withheld]
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 19 June 2017
Resolved
EKO02: Develop and submit repair proposal for damaged legs on port generator for review by USCG Marine Inspector. Prior to Carrying Passengers Underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 10 July 2017
Resolution: Cleared in person by [name withheld].
Electrical › Electric Generation Source (service) › Generator Cable
Issued 19 June 2017
Resolved
ML01: Develop and submit to satisfaction of CGMI, load sharing policy for vessel when operating with 3 compressors to operate 1/both gensets to prevent further loss of power incidents.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 10 July 2017
Resolution: Cleared in person by [name withheld]
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 16 March 2016
Resolved
Repair water tight door indicator for the pumproom watertight door.
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 30 March 2016
Resolution: Verified proper operation onboard.
Engineering › Fuel Oil Service System › Gauge
Issued 16 March 2016
Resolved
Make port fule tank sight glass availalbe for inspection.
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 30 March 2016
Resolution: Vessel installed new sightglass.
Engineering › Compressed Air System (control) › Valve
Issued 16 March 2016
Resolved
Prove proper function of ER air reciever relief valve.
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 4 May 2016
Resolution: New safety relief valve was purchased and installed.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 March 2016
Resolved
Properly lable circuit breaker on vent panel outside ER and port side 2nd deck (GFCI breakers)
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 30 March 2016
Resolution: All breakers properly labeled.