ISLAND PRINCESS

ISLAND PRINCESS is a 1988 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1988, most recently in April 2026, along with 89 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1988 to 2026. Most recent: inspection, 28 April 2026.

Built
1988
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTC9542
323255
Flag
UNITED STATES
367331570
Maury page id
psix-323255

Inspections, by type

…with no type recorded6
Years with a record 36 calendar years (1988–2026)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.0 ft × 21.0 ft × 6.5 ft
Registered tonnagegross 65 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS OF STUART INC · STUART, FL, UNITED STATES · built 1988
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSTUART, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 4 December 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5949MMSI 367331570 · active · compulsorily equipped · granted 16 May 2024, expires 16 May 2034
WTC9542MMSI 367331570 · cancelled · compulsorily equipped · granted 3 January 2018, cancelled 8 April 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PONTCHARTRAIN Industrial Vessel · MISLE 81458 · 16 January 1997 · activity 72925

Inspection history · 74

28 April 2026 Damage Survey · Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8373299
13 March 2026 Drydock Extension · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8323687
10 June 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8156496
22 January 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8067616
17 January 2024 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7851805
16 October 2023 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7809510
5 April 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7663600
14 June 2022 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7477285
11 February 2022 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7393633
6 October 2021 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7340720
12 May 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7340860
21 May 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6957845
12 August 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6781307
7 May 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6677984
19 February 2019 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6628119
21 August 2018 Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6518762
15 May 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6414879
22 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6341472
15 February 2017 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6088478
30 August 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5988031
17 May 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5879774
20 May 2014 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4864210
11 May 2012 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4308778
22 February 2012 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4248117
1 October 2010 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3860390
1 May 2009 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3469417
1 October 2008 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3336205
7 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3200706
19 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2938992
21 February 2007 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2877864
28 September 2006 Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2788781
17 April 2006 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2628343
4 February 2005 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2286745
22 September 2004 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2201064
5 May 2004 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2064869
11 April 2003 Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1771639
4 September 2002 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1670742
25 February 2002 COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1488814
16 March 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1059778
5 March 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1426539
8 September 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1365974
3 March 2000 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1389020
27 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781095
4 June 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1360925
23 April 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1126830
26 March 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 778398
8 March 1999 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375674
29 September 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 804714
13 March 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 788020
7 October 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1109882
17 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098690
16 January 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 72925
10 October 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1102300
20 September 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 833592
5 September 1996 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1254913
18 March 1996 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1077556
20 September 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1185885
12 July 1995 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 884091
24 March 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1183776
4 October 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1180467
1 April 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1169206
4 October 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1157776
30 April 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1150963
2 April 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840593
29 September 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1266289
3 April 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1261689
18 September 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1002684
5 April 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 916710
10 October 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 916679
18 September 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 911584
13 April 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 903075
12 September 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1225938
14 April 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1045079
15 April 1988 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1043624

Deficiency record · 89

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 March 2026 No resolution recorded
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed water instrusion coming into the vessel in the steering space port aft where the side shell meets the transom. Haul out required. 46CFR176.830
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 3 May 2023 Resolved
Master shall conduct sufficient fire drills to make sure that each crew member is familiar with his/her duties, crew was not available to evaluate drill.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2025
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 May 2023 Resolved
Master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties, crew was not available to demonstrate proficiency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2025
Resolution: completed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2023 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Main deck accommodation space emergency lighting would not illuminate and below deck crew galley did not have emergency lighting installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2025
Resolution: rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 May 2023 Resolved
On a vessel of more than 65' in length, the minimum capacity of the fire pump must be 189 liters per minute at a pressure of not less than 60 PSI at the pump. The pump outlet must be fitted with a pressure gauges. Electric power driven pump gauge was showing improper pressure of 40 PSI and the PTO driven pump did not have a gauge to determine proper pressure. Both pumps displayed good stream at the hose outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2025
Resolution: Rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 May 2023 Resolved
Each vessel that relies on electricity to power vital systems, including interior lighting, commas system, nav systems and ship's service power must be arranged so that the loads can be energized from two sources of electricity. Port gen-set was non-operational at the time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2025
Resolution: Rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 May 2023 Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator must be provided for a generator rated above 50 volts or more and each gen-set must also have a means for measuring frequency. Port gen-set was inoperable and STBD gen-sets required gauges were not functioning properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2025
Resolution: Rectified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 May 2023 Resolved
Owner or managing operator shall be prepared shall be prepared to conduct tests to include the following, inspection and and operation of all watertight closures in the hull. Aft bottom hull sewage discharge valve was missing its handle and could not function. Discharge appears locked in the closed position.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2025
Resolution: Rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2023 Resolved
Except when individual pumps are provided for sperate spaces, individual bilge suction lines must be led to a central control point or manifold and be provided with a stop valve and a check valve at some accessible point in the bilge line. Lazarette bilge line does not have a check valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 May 2023 Resolved
Spanner wrenches must be provided where a 1.5" fire hose is required. Vessel is missing 01 spanner wrenches.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2023
Resolution: Additional new spanner wrench onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2023 Resolved
A vessel must carry either a 1st aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents. 1st aid kit has expired items.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2025
Resolution: Rectified.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 3 May 2023 Resolved
The employer shall provide EAP for all crew members. There is no evidence of a EAP program in place, no evidence of supervisory personnel receiving 60 min of training, no evidence of crew training and no displayed documentation listing the EAP program.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2025
Resolution: Rectified.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 3 May 2023 Resolved
The bridge to bridge act and the regulations of this part apply to the following vessels in the navigable waters of the U.S.; (a)Every power driven vessel of 20 meters or over in length while navigating per 47 CFR 80.1001(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2025
Resolution: Rectified.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and in the other at the access to the machinery space. No portable lights found.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2023
Resolution: 2 new lights purchased and provided.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 3 May 2023 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 47 CFR 80.1101(c)(2). VHF radio onboard does not have MMSI number nor location capabilities installed per 47 CFR 80.905(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2025
Resolution: Rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2023 Resolved
Piping used in a vital system (bilge) must be composed of ferrous materials except when nonferrous metallic piping materials are permitted. Throughout the bilge piping there is non-metallic flexible hose connecting the metallic piping of the bilge system. Replace all flexible hosing in bilge system with like metallic piping currently installed in the bilge system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2025
Resolution: Rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Starboard propulsion engine turbo lagging is covered in oil, turbo hose loose, the top of the starboard engine is covered in oil and starboard oil filter leaking excessively.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 June 2022
Resolution: Starboard engine and components are in satisfactory condition.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 June 2022 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Vessel's machinery space has excessive accumulation of oil in the bilges creating a fire hazard in this space. 46 CFR 176.830(b)
Action required: 30 - Ship detained
Resolved 23 June 2022
Resolution: All oil removed from bilges.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 June 2022 Resolved
A fire pump may be driven by a propulsion engine. A fire pump must be permanently connected to the fire main and may be connected to the bilge system to meet the requirements of 182.520 of this chapter. Vessel's propulsion engine driven fire pump overboard discharge connection in the machinery space is not connected to the overboard valve allowing the possibility of flooding the machinery space is used. 46 CFR 181.300(d)
Action required: 30 - Ship detained
Resolved 23 June 2022
Resolution: Both fire pumps are plumbed SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 June 2022 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline; (2) A machinery space bilge, bilge well, shaft alley, bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. All of the required high water visual and audible alarms are inoperable at the operating station. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 11 August 2022
Resolution: Alarms operate SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 February 2022 Resolved
Fire Safety. Install metallic drip pans under both racor filters.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Corrected to the satisfaction of the attending Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 February 2022 Resolved
Manholes/ Flush scuttles. The vessel was actively dewatering the fwd peak when the MI arrived; replace the manhole gasket as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 February 2022
Resolution: Corrected to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 February 2022 Resolved
Hull structural condition. Superficial damage was noted above the waterline at the rub rail on both sides of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 February 2022
Resolution: Corrected to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2022 Resolved
Battery installations. Several battery terminals were found loose; clean and tighten all connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Connections secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2022 Resolved
Cable and wiring requirements. Found a 220V power cord plugged into an outlet for the warming oven. Make permanent connection or remove the cord as discussed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Cord removed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 February 2022 Resolved
Operational readiness. Found multiple adult PFD's beyond their service life. Owner is replacing as discussed.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2022
Resolution: Owner replaced 80 PFD's and discarding of the old ones to the satisfaction of the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2022 Resolved
Main steering gear. Found the STBD hydraulic hose chaffing on the steering ram; install chaffing as discussed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2022
Resolution: Chaffing gear installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 February 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline and vessels constructed of wood must, provide bilge level alarms in all watertight compartments except small buoyancy chambers. The bilge audible high level alarm for the fwd peak was found not working. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2022
Resolution: Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 October 2021 Resolved
Numerous areas on the hull found to either be blistered or have some type of corrosion. Marked areas to be ground back and repaired prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 18 October 2021
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 October 2021 Resolved
Repair/ replace damaged rub rail throughout the vessel prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 18 October 2021
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2021 Resolved
Port main cutlass bearing was found wore beyond acceptable tolerances. Replace in kind prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 18 October 2021
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 May 2021 Resolved
Each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape, one of which must not be a watertight door. A box fan was found blocking egress to the emergency escape scuttle. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 12 May 2021
Resolved 12 May 2021
Resolution: Corrected on the spot.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 May 2020 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline and vessels constructed of wood must, provide bilge level alarms in all watertight compartments except small buoyancy chambers. The bilge audible high level alarm for the fwd peak and galley are not working or not installed and need to be labeled at the operation station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2020
Resolution: Received pictures and video of high water alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2020 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Replace both worn and leaking hydraulic lines for the steering system in the tank room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2020
Resolution: Received pictures of the new hoses.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 May 2020 Resolved
In a vessel of 12 meters or more in length but less than 50 meters in length must have a: (i) A masthead light, 5 miles; except that where the length of the vessel is less than 20 meters, 3 miles;(ii) A sidelight, 2 miles. The mast light and port running light were not operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2020
Resolution: Received pictures of operational lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. The Galley breaker panel is missing blanks and remove all dead end wires as discussed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2020
Resolution: Received pictures of the corrected deficiency.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 May 2020 Resolved
Licensees of radio stations are required to have current station documents as indicated in the table. The FCC Safety Certificate is expired. Vessel is restricted to no more than 1000ft from shore.
Action required: 705 - Other - as specified
Resolved 25 May 2020
Resolution: Received pictures of the new certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 21 May 2020 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The STBD ventilation fan needs a safety cage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2020
Resolution: Received pictures of the new fan and guard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2020 Resolved
No flexible cord may be used except: (1) As allowed under Sections 400-7 and 400-8 of NFPA NEC 2002; and (2) In accordance with Table 400-4 in NFPA NEC 2002. Extension cords must not be used as a permanent connection to a source of electrical power. Remove all permanently installed extension cords (port A/c compressor and galley)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2020
Resolution: Received pictures of the corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following: Inspection of batteries for condition and security of stowage. The STBD SSDG Battery terminals were found excessively corroded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2020
Resolution: Received picture of corrected deficiencies.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 May 2020 Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Make all cable runs watertight in the watertight bulkhead in the tank room as discussed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2020
Resolution: Received pictures of the repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2020 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. No training has taken place.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2020
Resolution: Received pictures of the corrected deficiency
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 May 2019 Resolved
Demonstrate operation of visual alarm for lazarette high bilge water indicator.
Action required: 10 - Deficiency Rectified
Due 7 May 2019
Resolved 7 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2019 Resolved
Provide and mark seperate stowage for child PFDs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 June 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 May 2019 Resolved
Demonstrate operation of engineroom ventilation closers.
Action required: 10 - Deficiency Rectified
Due 7 May 2019
Resolved 7 May 2019
Resolution: Temporary closures were fabricated while permanent repairs to the louvered vents could be completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2018 Resolved
Repair or replace propellers due to cracking, bending and excessive pitting on blades prior to credit dry-dock. 46 CFR 176.25-5
Action required: 705 - Other - as specified
Resolved 4 September 2018
Resolution: Propellers replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 August 2018 Resolved
Repair all blistered areas on hull that penetrate fiberglass prior to credit dry-dock. 46 CFR 176.25-5
Action required: 705 - Other - as specified
Resolved 4 September 2018
Resolution: Repairs made.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 August 2018 Resolved
Repair rotted transverse frame around bolt at center line, forward bulkhead in lazerette prior to credit dry-dock. 46 CFR 176.25-5
Action required: 705 - Other - as specified
Resolved 4 September 2018
Resolution: Rotted wood removed and frame sistered with 12" section of mahogony.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 August 2018 Resolved
Arrest wood decay/rot under MSD holding tank in lazerette prior to credit dry-dock. 46 CFR 176.25-5
Action required: 705 - Other - as specified
Resolved 4 September 2018
Resolution: Wood rot removed. Remaining wood covered with fiberglass and resin.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 August 2018 Resolved
Seal port quarter open seam on transom at waterline to make watertight prior to credit dry-dock. 46 CFR 176.25-5
Action required: 705 - Other - as specified
Resolved 4 September 2018
Resolution: Seam sealed with 5200.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 August 2018 Resolved
Secure loose upper deck starboard side railing and stanchions prior to credit dry-dock. 46 CFR 176.25-25
Action required: 705 - Other - as specified
Resolved 4 September 2018
Resolution: Railing secured.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 August 2018 Resolved
Repair loose and rotted steps going to upper deck prior to credit dry-dock. 46 CFR 176.25-5
Action required: 705 - Other - as specified
Resolved 4 September 2018
Resolution: Steps repaired.
Fire Fighting › Fire Main › Valves
Issued 15 February 2017 Resolved
Stop leak on fire main gate valve to overboard discharge.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Stability › Incline Test › General
Issued 22 February 2012 Resolved
Provide amended stability letter by G-MSC indicating compliance with AAWPP of 185 lbs effective 01 Dec 2011.
Due 31 May 2012
Resolved 11 May 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 February 2007 Resolved
Provide rotating machinery guard on the FWD port main engine.
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 7 May 2008
Resolution: Provided rotating machinery guard on the FWD port main engine.
Fire Fighting › Fire Hoses › Condition
Issued 21 February 2007 Resolved
Renew fire hoses IAW 46 CFR 181.320.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2007
Resolved 23 February 2007
Resolution: Renewed fire hoses IAW 46 CFR 181.320.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 February 2007 Resolved
Prove port NAV light meets UL 1104 standards IAW 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 7 May 2008
Resolution: Provided port UL NAV light.
Lifesaving › Hand Flares › Storage
Issued 21 February 2007 Resolved
Provide proper container for distress flares IAW 46 CFR 185.614.
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 7 May 2008
Resolution: Provided proper container.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 17 April 2006 Resolved
Properly arrange mechanical ventilation to de-energize upon automatic activation of fixed firefighting system IAW 46CFR181.410 (b)(10).
Due 30 April 2006
Resolved 21 February 2007
Resolution: Done
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 April 2006 Resolved
Provide documentation showing Yellow Jacket wiring meets U/L marine grade cable requirements.
Due 30 April 2006
Resolved 28 September 2006
Resolution: Owner removed all questionable wiring and installed marine grade cable.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 17 April 2006 Resolved
Provide current Compass Deviation Table.
Due 30 April 2006
Resolved 28 September 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 17 April 2006 Resolved
Properly repair audible alarm for bilge alarm in the Galley.
Due 30 April 2006
Resolved 17 April 2006
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 17 April 2006 Resolved
Provide updated Coast Pilot.
Due 30 April 2006
Resolved 28 September 2006
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 17 April 2006 Resolved
Properly arrange Emergency Escape ladder in galley and make exit easily accessible.
Due 30 April 2006
Resolved 28 September 2006
Stability › Watertight Integrity › General
Issued 4 February 2005 Resolved
Remove newly installed PVC pipng or install metallic valves IAW 46CFR182.770(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 28 September 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 5 May 2004 Resolved
PROVIDE CURRENT COPIES OF TIDES AND CURRENT TABLES IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 18 June 2004
Resolved 18 June 2004
Personnel › Training › Fire Fighting Basic
Issued 5 May 2004 Resolved
DEMONSTRATE PROPER OPERATION OF MAN OVERBOARD RECOVERY SYSTEM IAW 46 CFR 180.210.
Action required: 705 - Other - as specified
Due 18 June 2004
Resolved 18 June 2004
Documentation › Certificates/Documents › FCC SSL
Issued 11 April 2003 Resolved
RADIO SAFETY TELEPHONEY CERTIFICATE NOT PROVIDED. LEGACY COMPONENT DESC: RADIO SAFETY TELEPHONEY CERTIFICATE
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 5 May 2004
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 11 April 2003 Resolved
CPR CARDS NOT PROVIDED FOR 50% OF CREW.
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 5 May 2004
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 April 2003 Resolved
NAV RULES, TIDE AND CURRENTS TABLES NOT PROVIDED.
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 5 May 2004
Documentation › Logs/Records › Logbook (official)
Issued 11 April 2003 Resolved
ALL REQUIRD DRILLS AND GARBAGE DISPOSAL NOT BEING LOGGED. LEGACY COMPONENT DESC: Logbook (official)
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 5 May 2004
Deck/Cargo
Issued 5 March 2001 Resolved
Properly store co2 cylinders used for the bar.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Fire Fighting
Issued 5 March 2001 Resolved
Provide proof of fire extinguisher servicing by 30April01.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Lifesaving
Issued 5 March 2001 Resolved
Provide reflective tape, light floats, and paddles on life floats. Life_x001C_ floats are not required for vessel but, since they are onboard they must_x001C_ meet applicable requirements.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Lifesaving
Issued 5 March 2001 Resolved
Replace coarsing on ring buoy
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Documentation
Issued 5 March 2001 Resolved
Provide current DAPI consortium contract and copy of latest mis form submitted to the USCG.
Condition: Unknown
Due 19 March 2001
Resolved 6 March 2001
Fire Fighting
Issued 3 March 2000 Resolved
Prove operation of (2) multi-purpose nozzles for fire hoses.
Condition: Unknown
Due 7 March 2000
Resolved 13 March 2000
Construction/Loadline
Issued 3 March 2000 Resolved
Prove operation of bilge high level alarms in forepeak.
Condition: Unknown
Due 7 March 2000
Resolved 13 March 2000
Construction/Loadline
Issued 4 June 1999 Resolved
PROVIDE PROPER REPAIR IN WAY OF PORT GARBOARD STRAKE TANK ROOM.
Condition: Unknown
Due 16 June 1999
Resolved 17 June 1999
Construction/Loadline
Issued 4 June 1999 Resolved
CROP & RENEW HULL PLATING IN WAY OF STBD GARBOARD STRAKE FM KEEL AT FRAME 1-12 AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 16 June 1999
Resolved 17 June 1999
Construction/Loadline
Issued 4 June 1999 Resolved
CROP & MAKE PROPER REPAIR TO FLOOR FRAMES AS REQUIRED TO GOOD WOOD.
Condition: Unknown
Due 16 June 1999
Resolved 17 June 1999
Documentation
Issued 8 March 1999 Resolved
PROVIDE CONSORTIUM INFORMATION TO COMPLETE CHEMICAL TESTING AUDIT.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Fire Fighting
Issued 8 March 1999 Resolved
PROVIDE FOR AUTOMATIC DISCHARGE OR INSTALL CG APPROVED DETECTION SYSTEM FORENGINE ROOM MANUALLY ACTIVATED FIXED FIRE EXT. SYSTEM.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Lifesaving
Issued 8 March 1999 Resolved
RENEW RETRO-REFLECTIVE TAPE ON 8 CHILD LIFE PRESERVERS.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Lifesaving
Issued 18 March 1996 Resolved
REPLACE LIFELINE ON LF #2 AND #3.
Condition: Unknown
Due 18 April 1996
Resolved 15 April 1996
Documentation
Issued 2 April 1993 Resolved
SCHEDUAL INSPECTOR VISIT TO MEASURE UPPER DECK TO ASERTAIN MAXIMUM NUMBER OF PASSENGERS ALLOWED.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993 Resolved
PROVIDE 10 ADDITIONAL ADULT LIFEJACKETS, VESSEL RESTRICTED TO 148 TOTAL PERSONS UNTIL COMPLIANCE.
Condition: Unknown
Due 2 May 1993
Resolved 12 April 1993
Documentation
Issued 2 April 1993 Resolved
HAVE BUILDER SUBMIT CORRECTED BUILDERS CERTIFICATE TO DOCUMENTATION TO REFLECT PROPER HULL MATERIAL. THIS VESSEL IS CONSIDERED TO BE OF WOOD CONSTRUCTION, NOT THE FRP INDICATED.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 13 April 1990 Resolved
PROVIDE RESCUE BOAT OR RESCUE PLATEFORM IAW 46 CFR 180.10-35.
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990