Records from 1991 to 2011. Most recent: inspection, 24 February 2011.
Inspection history · 23
24 February 2011
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3952809
5 February 2011
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3941898
5 February 2011
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3972033
29 October 2010
NPV Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3881090
7 November 2007
MARPOL Annex I Examination
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3095619
24 May 2007
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2948216
6 January 2005
MARPOL Annex I Examination
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2271219
11 July 2002
Type not recorded
No type recorded · USCG Oceania District (dpi) · USCG Oceania District (CGD-O) · Activity 1644855
4 September 2001
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 113287
22 August 2001
MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1450672
5 February 2001
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 717
30 October 2000
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 283624
6 May 1996
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 671802
9 March 1996
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 226908
9 March 1996
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 231670
9 March 1996
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 390916
5 April 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 676843
24 November 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 676841
29 October 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 354104
31 October 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 86650
24 April 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 998834
23 April 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 498195
17 April 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 343476
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 29 October 2010
Resolved
Instructions for fixed CO2 system is not present. Provide instructions prior to next U.S. port.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2010
Resolved 24 February 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 29 October 2010
Resolved
Fixed CO2 system does not have highly visible markings for activation.
Action required: 705 - Other - as specified
Due 29 November 2010
Resolved 24 February 2011
Communications › Alarms/Indicators › General Alarm
Issued 29 October 2010
Resolved
Ensure general alarm is visible and audible on wet deck and engine room.
Action required: 705 - Other - as specified
Due 29 November 2010
Resolved 25 February 2011
Documentation › Markings/Placards › Garbage Placard
Issued 29 October 2010
Resolved
Garbage Placard is missing and Oil Discharge Placard is out of date. USCG will provide proper placards but vessel needs to post in proper locations.
Action required: 705 - Other - as specified
Due 29 November 2010
Resolved 24 February 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 October 2010
Resolved
Stern light is not visible when nets are on board. Move stern light to a more visible location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 November 2010
Resolved 25 February 2011
Stability › Watertight Integrity › General
Issued 29 October 2010
Resolved
Ensure all water tight doors have proper gaskets.
Action required: 705 - Other - as specified
Due 29 November 2010
Resolved 24 February 2011
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 29 October 2010
Resolved
Provide oil transfer procedures with block diagram for vessel. Procedures were lost during crew transfers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2010
Resolved 25 February 2011
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 January 2005
Resolved
Install and demonstrate proper operation of oil discharge monitor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 January 2005
Resolved
Provide on board original certificate of documentation.
Due 5 February 2005
Resolved 8 January 2005
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 6 January 2005
Resolved
Replace wasted fuel tank vent piping on deck. 1 port side and 1 stbd side. Correct at next drydock no later than due date.
Due 31 August 2005
Resolved 10 May 2007
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 6 January 2005
Resolved
Install flame screens in all starboard fuel tank vents.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2005
Documentation
Issued 9 March 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 April 1996
Resolved 6 May 1996
Documentation
Issued 9 March 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 November 2000
Resolved 3 November 2000
Fire Fighting
Issued 29 October 1992
Resolved
CG BOARDING OFFICER FOUND THAT ALL PORTABLE FIRE EXTINGUISHERS NEEDED ANNUAL INSPECTION.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Documentation
Issued 17 April 1991
Resolved
OIL RECORD BOOK INCOMPLETE. ENTRIES MISSING FROM DEC89 TO DEC90._x001C_ _x001C_ 33CFR151.25(D)
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Documentation
Issued 17 April 1991
Resolved
VESSEL HAD NO VALID IOPP CERTIFICATE ON BOARD. CERT EXPIRED 15 APRIL 91._x001C_ DEFICIENCY CITATION: 33 CFR 151.19
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Documentation
Issued 17 April 1991
Resolved
OIL RECORD BOOK INCOMPLETE. SIGNATURES BY PERSON-IN-CHARGE NOT ENTERED._x001C_ _x001C_ 33CFR151.25(H)
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991