MAURY USCG vessel records Sign in
← All vessels

NORMAN MCCALL

NORMAN MCCALL is a 1989 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1989, most recently in October 2016, along with 51 deficiencies and 1 operational control.

Records from 1989 to 2016. Most recent: inspection, 31 October 2016.

Built
1989
Last inspected
31 October 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8978423 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WUS5526
324202
Flag
VANUATU
366743110 (licence lapsed)
Maury page id
psix-324202

Inspections, by type

…with no type recorded10
Years with a record 19 calendar years (1989–2016)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it117 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
390 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WUS5526MMSI 366743110 · cancelled · voluntarily equipped · granted 14 January 2004, cancelled 13 September 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 47

31 October 2016 Type not recorded
No type recorded · Activities Europe · Activity 6032245
17 July 2006 Administrative Inspection
Administrative · Activities Europe · Activity 2715538
23 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571519
4 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303754
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290170
10 November 2004 Type not recorded
No type recorded · Activities Europe · Activity 2238243
1 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232645
21 August 2004 Hull Examination · Annual Inspection
Physical examination · Activities Europe · Activity 2171351
23 June 2004 MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2098821
3 June 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2087745
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971726
28 October 2003 Deficiency Check
Physical examination · Activities Europe · Activity 1968700
12 September 2003 Type not recorded
No type recorded · Activities Europe · Activity 1903309
12 August 2003 Deficiency Check · COI Inspection
Physical examination · Activities Europe · Activity 1859137
8 August 2002 Hull Examination · Annual Inspection
Physical examination · Activities Europe · Activity 1632355
7 January 2002 Deficiency Check
Physical examination · Activities Europe · Activity 1475855
27 August 2001 COI Inspection
Physical examination · Activities Europe · Activity 1362481
14 September 2000 Hull Examination · Re-Inspection
Physical examination · Activities Europe · Activity 1361809
15 June 2000 Re-Inspection
Physical examination · Activities Europe · Activity 1051789
26 July 1999 Administrative
Administrative · Activities Europe · Activity 1106396
26 August 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388600
3 February 1998 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122563
4 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776701
22 August 1997 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428844
6 January 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 754129
31 December 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 196340
25 August 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085455
23 August 1996 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1442447
20 November 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 73523
25 August 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358877
12 August 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356760
29 March 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 855541
17 November 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 91813
17 November 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 159349
16 August 1993 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387383
11 August 1992 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439330
31 December 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953239
28 December 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 120205
28 December 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 228977
26 August 1991 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 937115
26 August 1991 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1246835
9 July 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247675
18 December 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218263
30 January 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911275
22 August 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205616
24 February 1989 Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1039787
17 February 1989 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification · Plan Review "T" Boat
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344926

Deficiency record · 51

Accommodation/Occupational Safety › Sleeping Accommodations › Area Per Person
Issued 10 September 2004 Resolved
Provide plans for accommodations added without USCG approval. Accommodations were added for 6 additional crewmembers (three, two man staterooms) on port side of passenger space. With passenger seating removed, max 40 passengers allowed onboard. Lifesaving remained unchanged.
Due 10 October 2004
Resolved 18 February 2005
Resolution: resolved, to be verified next inspection. T.G. [name withheld], LT
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 September 2004 Resolved
Provide adaquate drug and alcohol testing program. Current program only tests U.S. master or crew upon knowledge of impending test date.
Due 10 October 2004
Resolved 1 November 2004
Resolution: Provided. T.G. [name withheld], LT
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 10 September 2004 Resolved
Replace expired lifejacket lights with USCG approved lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2004
Resolved 17 September 2004
Resolution: Lights replaced. M.E. [name withheld], [name withheld]
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 September 2004 Resolved
Provide emergency lighting for escape scuttle from passenger accommodation space.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2004
Resolved 17 September 2004
Resolution: [name withheld], [name withheld]
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 September 2004 Resolved
Provide operational magnetic compass.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2004
Resolved 17 September 2004
Resolution: Cleared M. E. [name withheld], [name withheld]
Electrical › Electric Supply System (service) › Cable
Issued 10 September 2004 Resolved
Install proper stuffing tubes and approved fire stop as required for all water tight bhds.
Due 10 October 2004
Resolved 17 September 2004
Resolution: Cleared M. E. [name withheld], [name withheld]
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 10 September 2004 Resolved
Provide metal vent hose for clothes dryer.
Due 10 October 2004
Resolved 10 October 2004
Resolution: Provided.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 9 September 2004 Resolved
Provide approved mattresses for accomidations in accordance with 46 CFR 177.405 (g)
Due 10 October 2004
Resolved 1 November 2004
Resolution: Provided. T.G. [name withheld], LT
Electrical › Electrical Distribution System (service) › Cable
Issued 21 August 2004 Resolved
Provide romex connestors for electrical cables entering breaker panel. Provide protection for electrical cables routed thourgh the overhead of accomidation spaces; either by installing a junction box or ensuring the sheathing is intact through the penetrations. Items required for accomidation plan approval.
Due 13 January 2005
Resolved 18 February 2005
Resolution: Resolved, to be verified next inspection. T.G. [name withheld], LT
Electrical › Electrical Distribution System (service) › Cable
Issued 21 August 2004 Resolved
Remove 220 volt outlet, routed w/extension cord, from bridge distribution panel to galley.
Due 13 January 2005
Resolved 18 February 2005
Resolution: Resolved, to be verified next inspection. T.G. [name withheld], LT
Documentation › Certificates/Documents › International Load Line Certificate
Issued 25 June 2004 Resolved
Provide onboard valid International Load Line Certificate. Current certificate expired before the issue date (2003) and the based on survey date was listed as 2008.
Due 25 September 2004
Resolved 9 September 2004
Resolution: Cleared and verified onboard during annual and drydock exam. MED
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 25 June 2004 Resolved
Provide onboard valid radio safety certificate. Current certificate expired on 26MAR04.
Due 25 September 2004
Resolved 9 September 2004
Resolution: Cleared and verified onboard during annual and drydock exam. MED
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 25 June 2004 Resolved
Repair inoperative port inboard main engine low lube oil alarm.
Due 25 September 2004
Resolved 9 September 2004
Resolution: Cleared and verified onboard during annual and drydock exam. MED
Fire Fighting › Semiportable CO2 Fire Extinguishers › Dsicharge Nozzle
Issued 25 June 2004 Resolved
Replace cracked/busted CO2 hose for paint locker semi-portable fire fighting system
Due 25 September 2004
Resolved 9 September 2004
Resolution: Cleared and verified onboard during annual and drydock exam. MED
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 25 June 2004 Resolved
Remove non-USCG approved portable fire extinguishers and if necessary replace with USCG approved extinguishers as per COI.
Due 25 September 2004
Resolved 9 September 2004
Resolution: Cleared and verified onboard during annual and drydock exam. MED
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 June 2004 Resolved
Removed non-USCG approved water light and smoke signal attached to port and starboard life rings.
Due 25 September 2004
Resolved 9 September 2004
Resolution: Cleared and verified onboard during annual and drydock exam. MED
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 June 2004 Resolved
Re-stencil vessel's name on port and starboard life rings.
Due 25 September 2004
Resolved 9 September 2004
Resolution: Cleared and verified onboard during annual and drydock exam. MED
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 25 June 2004 Resolved
Replace all expired life jacket water lights.
Due 25 September 2004
Resolved 9 September 2004
Communications › Radio Communications
Issued 12 August 2003 Resolved
1. EPIRB missing NOAA registration sticker. Obtain and properly affix NOAA registration sticker to the EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 12 August 2003
Resolved 28 October 2003
Resolution: Received notification from the vessel master dated 28 October 2003 that the EPIRB registration sticker was received onboard the vessel. Verify at next visit to the vessel.
Documentation › Certificates/Documents
Issued 12 August 2003 Resolved
2. Properly post the Certificate of Inspection in accordance with 46CFR 176.302 LEGACY COMPONENT DESC: Certificate of Inspection
Due 5 September 2003
Resolved 5 September 2003
Resolution: Received notification from the vessel master dated 5 September that the Certificate of Inspection was properly posted under glass in the wheel house with all pages visible. Verify at next visit to the vessel.
Documentation › Certificates/Documents
Issued 12 August 2003 Resolved
3. Post the stability letter with all the pages visible in accordance with 46CFR 176.302 LEGACY COMPONENT DESC: Stability Letter
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 5 September 2003
Resolution: Received notification from the vessel master dated 5 September that the Stability Letter was properly posted under glass in the wheel house. Verify at next visit to the vessel.
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 August 2003 Resolved
4. Properly secure the life preserver lights to the shoulder area of the life jackets. IAW 46CFR 180.75 LEGACY COMPONENT DESC: Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 5 September 2003
Resolution: Received e mail notification from the vessel master dated 5 September that the life jacket water lights were properly secured to the shoulder area of the life jackets. Verify at next visit to the vessel.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 12 August 2003 Resolved
5. Properly mount the portable fire extinguishers in accordance with National Fire Protection Association (NFPA) 10. i.e. 4 inches above the floor with the approved brackets for the manufacturer of the fire extinguisher.. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 5 September 2003
Resolution: Received notification from the vessel master dated 5 September that the fire extinguishers were properly mounted. Verify at next visit to the vessel.
Electrical › Lighting (emergency)
Issued 12 August 2003 Resolved
6. Emergency light fixture lens discolored, renew/refurbish light fixture lens to permit the passage of light. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 5 September 2003
Resolution: Lens cleaned. Verify at the next visit to the vessel.
Electrical › Lighting (emergency)
Issued 12 August 2003 Resolved
7. Emergency light fixture located in the upper lounge has the socket adrift in fixture renew/repair as original. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 5 September 2003
Resolution: New socket installed. Verify at next visit to the vessel.
Communications › Alarms/Indicators
Issued 12 August 2003 Resolved
8. Replace/Renew as original the broken main engine tachometers located in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 28 October 2003
Resolution: Received notification from the vessel master dated 28 October 2003 that requirements the tachometers were renewed. Verify at next visit to the vessel.
Communications › Visual Communication
Issued 12 August 2003 Resolved
9. Renew missing lenses on the engine alarm panel on bridge. Provide lamp test for the alarm panel and restore as original. LEGACY COMPONENT DESC: Red Warning Signal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 5 September 2003
Resolution: Lens renewed and lamp test restored. Verify at next visit to the vessel.
Communications › Visual Communication
Issued 12 August 2003 Resolved
10. Renew broken and discolored control air pressure gauge lenses on the bridge console.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 28 October 2003
Resolution: Received notification from the vessel master dated 28 October 2003 all requirements were cleared. Verify at next visit to the vessel.
Operations/Management › Drills/Instruction
Issued 12 August 2003 Resolved
11. Post a durable emergency broadcast placard next to all radio telephone installations as required by 46CFR 184.506. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 5 September 2003
Resolution: Emergency broad cast placard posted at radio stations.
Lifesaving › Lifebuoys
Issued 12 August 2003 Resolved
12. Provide buoyant life line for the ring buoy IAW 46CFR 180.70 (c). LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 5 September 2003
Resolution: Bouyant line provided for ring buoy. Verify at next visit to the vessel.
Stability › Watertight Integrity › General
Issued 12 August 2003 Resolved
13. Make permanent repair to pitted area in way of the bilge forward side of the fuel tank at the next dry-dock exam.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 10 September 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 8 August 2002 Resolved
Provide hydrostatic testing of portable fire extinguishers on aft bulkhead of accommodation space (X2) and on stbd side of bridge (X1) 46CFR176&181. CLEARED VIA LETTER. INSPECT AT NEXT ANNUAL (2003) LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 8 August 2003
Resolved 11 August 2003
Resolution: inspected
Navigation › Collision/Grounding Avoidance
Issued 8 August 2002 Resolved
Repair and prove operational general alarm and fog signal 46CFR183.550 & 33CFR86 CLEARED VIA LETTER. INSPECT AT NEXT ANNUAL (2003) LEGACY COMPONENT DESC: Danger Messages
Due 8 August 2003
Resolved 11 August 2003
Resolution: inspected
Lifesaving › Inflatable Liferafts
Issued 8 August 2002 Resolved
Provide liferafts (total 75 persons) onboard and serviced 46CFR180.175&200 CLEARED VIA LETTER. INSPECT AT NEXT ANNUAL (2003)
Due 11 August 2003
Resolved 11 August 2003
Resolution: inspected
Accommodation/Occupational Safety › Occupational Safety
Issued 8 August 2002 Resolved
Provide public address system for all spaces normally manned by the crew and passengers. (ie. accommodation space, engine room, galley, etc.) 46CFR184.610 CLEARED VIA LETTER. INSPECT AT NEXT ANNUAL (2003)
Due 11 August 2003
Resolved 11 August 2003
Resolution: inspected
Engineering
Issued 8 August 2002 Resolved
The following tests are to be completed prior to receiving credit for annual exam; single side band, radar, main propulsion & bridge control of main propulsion engines, generators incl: LO & overspeed alarms, bilge pump incl: suction from each bilge well, fire pumps incl: hoses & drills
Due 26 November 2002
Resolved 26 September 2002
Resolution: CLEARED VIA LETTER BY VESSEL MASTER, [name withheld] LIC 914423 CONFIRMING ALL TEST WERE COMPLETED SAT.
Construction/Loadline
Issued 27 August 2001 Resolved
REPAIR STEERING GEAR HIGH LEVEL BILGE ALARM TO INDICATE BOTH AUDIABLY AND VISUALLY ON THE BRIDGE.
Condition: Unknown
Due 26 September 2001
Resolved 14 October 2001
Documentation
Issued 27 August 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 October 2001
Resolved 7 January 2002
Resolution: REQUIREMENT CLEARED VIA FAX DATED 13 NOV 01.
Documentation
Issued 27 August 2001 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING FOR ALL CREW (IE. TESTING LOG, PREVIOUS TEST REPORTS, ECT.) 46CFR16.
Condition: Unknown
Due 27 October 2001
Resolved 7 January 2002
Resolution: Deficiency cleared via fax dated 13NOV01.
Fire Fighting
Issued 27 August 2001 Resolved
PROVIDE HYDROSTATIC TESTING FOR THE BRIDGE (BC1) AND AFT PASSENGER CABIN (BCII) EXTINGUISHERS. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 October 2001
Resolved 7 January 2002
Resolution: Deficiency cleared via fax dated 13NOV01.
Documentation
Issued 27 August 2001 Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD FRO PASSENGERS TO OPERATE THE VHF IN CASE OF EMERGENCY. 46CFR184.506
Condition: Unknown
Due 26 September 2001
Resolved 14 October 2001
Fire Fighting
Issued 27 August 2001 Resolved
PROVIDE CERTIFICATION PROVING PAINT LOCKER FIXED EXTINGUISHER IS CG APPROVED. 46CFR176.
Condition: Unknown
Due 27 October 2001
Resolved 7 January 2002
Resolution: Deficiency cleared via fax dated 13NOV01.
Construction/Loadline
Issued 27 August 2001 Resolved
REPAIR (V AND WELD) BROKEN FORWARD BULKHEAD WELD (BETWEEN 2ND AND 3RD LONGITUDINAL BULKHEAD STIFFENER/80-90 CM FROM PORT SIDESHELL AT INTERCONNECTION WITH MAIN DECK) IN STEERING GEAR COMPARTMENT PORT SIDE.
Condition: Unknown
Due 4 October 2001
Resolved 14 October 2001
Construction/Loadline
Issued 27 August 2001 Resolved
REPAIR (V AND WELD BROKEN WELD IN THE AFT PORT QUARTER OF THE STEERING GEARCOMPARTMENT AT THE INTERCONECTION BETWEEN THE PORT SIDESHELL AND MAIN DECK.
Condition: Unknown
Due 4 October 2001
Resolved 14 October 2001
Construction/Loadline
Issued 27 August 2001 Resolved
REPAIR (V AND WELD) CRACKED FULL ROUND MAIN DECK TO SIDE SHELL STIFFENER ATPORT QUARTER OF STEERING GEAR.
Condition: Unknown
Due 4 October 2001
Resolved 14 October 2001
Construction/Loadline
Issued 27 August 2001 Resolved
REPAIR (V AND WELD) BROKEN WELD ON FORWARD SIDE OF 5TH FRAME FROM BOW BETWEEN 1ST AND 2ND SIDESHELL LONGITUDINAL STIFFENER FROM THE MAIN DECK IN FORWARD PEAK TANK.
Condition: Unknown
Due 4 October 2001
Resolved 14 October 2001
Construction/Loadline
Issued 27 August 2001 Resolved
REPAIR (V AND WELD BOTH SIDES) 3RD FRAME FROM BOW BETWEEN 1ST AND 2ND TRANSVERSE DECK STIFFENER IN THE FORWARD PEAK TANK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 2001
Resolved 14 October 2001
Construction/Loadline
Issued 27 August 2001 Resolved
REPAIR (V AND WELD) BROKEN WELD AT 5TH FRAME FROM BOW ANTD 1ST SIDESHELL LOGITUDINAL FROM THE MAIN DECK IN THE FORWARD PEAK TANK.
Condition: Unknown
Due 4 October 2001
Resolved 14 October 2001
Construction/Loadline
Issued 27 August 2001 Resolved
REPAIR (V AND WELD) BROKEN WELD AT THE AFT FORWARD PEAK TANK BULKHEAD AND 3RD SIDESHELL LONGITUDINAL.
Condition: Unknown
Due 4 October 2001
Resolved 14 October 2001
Construction/Loadline
Issued 27 August 2001 Resolved
REPAIR (V AND WELD) BROKEN WELD FOR UNDER DECK BITT SUPPORT IN PORT SIDE CRAWL SPACE AFT OF THE 3RD FRAME FORWARD OF THE AFTER BULKHEAD.
Condition: Unknown
Due 4 October 2001
Resolved 14 October 2001
Navigation
Issued 15 June 2000 Resolved
Install rudder angle indicators at all steering control stations in accordance with 46 CFR 182.610(f)(2).
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.