MAURY USCG vessel records Sign in
← All vessels

KASHMIR

KASHMIR is a 1988 tank ship. The Coast Guard has recorded 33 inspections since 1989, most recently in January 2008, along with 17 deficiencies and 3 operational controls.

Records from 1989 to 2008. Most recent: operational control imposed, 17 January 2008.

Built
1988
Last inspected
17 January 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8800248 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
324272
Flag
MALTA
—
Maury page id
psix-324272

Inspections, by type

…with no type recorded19
Years with a record 15 calendar years (1989–2008)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it27611 - Convention (Subpart B), Gross Ton
12344 - Convention (Subpart B), Net Ton
45003 - Dead Weight, Ton
53915 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

17 January 2008 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3132228
27 July 2007 Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 3008871
23 July 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3005170
18 March 2007 ISPS II Exam · MARPOL Annex II Examination · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2889330
4 May 2005 Ballast Water Examination · Deficiency Check · MARPOL Annex I Examination · COC-CHEM Annual · MARPOL Annex II Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2349141
4 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2349518
4 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2350242
4 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2352839
30 April 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2346569
22 April 2004 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2050344
12 February 2002 Deficiency Check · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1485955
18 October 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294805
18 October 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 294807
27 August 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 293216
27 May 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278326
27 January 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274057
27 January 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1045854
15 June 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 416770
15 June 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 792470
4 February 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 387389
4 February 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1183231
22 September 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 497994
29 December 1993 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1160598
20 May 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 442884
30 October 1992 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1245169
16 September 1992 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 953333
17 June 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1259764
27 March 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 342736
1 May 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 489636
26 April 1989 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1193998
1 April 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 459100
1 April 1989 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1205698
4 January 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 327667

Deficiency record · 17

Lifesaving › Launching Appliances › Falls
Issued 17 January 2008 Resolved
Vessels's STBD lifeboat fall was damaged during the last abandon ship drill. Vessel shall submit documentation from Certificate issuing authority attesting to the replacement of and testing of the lifeboat fall.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 17 January 2008 Resolved
Vessel has a straight stream leak of Hydraulic fluid from PTO on #1 Cargo pump. Pump must not be used in U.S. waters until satisfactory repairs have been completed.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 January 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 17 January 2008 Resolved
Vessel has a fuel oil leak on main engine's injectors for cylinders #2 and #5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Engineering › Fuel Oil Service System › Piping
Issued 17 January 2008 Resolved
Vessel's lagging on main engine's heavy fuel oil supply line IVO relief valve is wasted and oil soaked. Repair leak and replace lagging.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2008
Engineering › Steam System (main) › Piping
Issued 17 January 2008 Resolved
Vessel has a steam leak on the heating system of main engine's fuel oil supply IVO cylinder #2's high pressure fuel pump.
Due 17 February 2008
Resolved 19 January 2008
Engineering › Steam System (auxiliary) › Piping
Issued 17 January 2008 Resolved
Vessel has a steam leak on the boiler fuel oil supply line.
Due 17 February 2008
Resolved 19 January 2008
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 17 January 2008 Resolved
Vessel's IGS is inoperable. Request that vessel's certificate issuing authority dubmit a plan to USCG for repairs of IGS or removal of tanker certification as per vessel's IOPP.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 January 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 22 April 2004 Resolved
Cargo Gauging equipment in the cargo control room is showing inaccurate tank level readings, for cargo tanks 8C and 7C. Repair or replace gauging equipment to the satisfaction of the Certificate of Fitness issuing authority prior to loading tanks 8C and 7C. IBC regulation 13.1.1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2005
Resolution: Deficiency cleared by NEWMS inspection team.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 April 2004 Resolved
Vessel unable to demonstrate the proper operation of its portable vapor detection equipment. IBC regulation 13.2. Demonstrate proper operation of portable vapor detection equipment or replace equipment to the satisfaction of the Certificate of Fitness issuing authority prior to 29APR04.
Condition: Improper/Lack of Maintenance
Due 29 April 2004
Resolved 4 May 2005
Resolution: Deficiency cleared by NEWMS inspection team.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 22 April 2004 Resolved
Vessel unable to demonstrate that the ODME is operating properly. MARPOL Annex I, regulation 15. Demonstrate proper operation of the ODME to the satisfaction of the IOPP certificate issuing authority prior to operation on the ODME. LEGACY COMPONENT DESC: Oily Mixture Discharge Pump
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 4 May 2005
Resolution: Deficiency cleared by NEWMS inspection team.
Deck/Cargo
Issued 18 October 2001 Resolved
Prior to loading Grade B Cargo or lower, prove proper operation of IGS as per referenced class survey report dated 30 May 01.
Condition: Unknown
Due 12 February 2002
Resolved 12 February 2002
Resolution: Vessel is in dedicated Methanol trade and has blocked off their IGS. Vessel also has a Special note addressing this fact on their History.
Deck/Cargo
Issued 27 August 2001 Resolved
Prior to loading Grade B Cargo or lower, prove proper operation of IGS as_x001C_ per referenced class survey report dated 30 MAY 01.
Condition: Unknown
Due 19 October 2001
Resolved 19 October 2001
Documentation
Issued 27 August 2001 Resolved
Provide copy of Document of Compliance endorsement within 60 days IAW SOLASChap. IX Regulation 4.3.
Condition: Unknown
Due 19 October 2001
Resolved 19 October 2001
Unknown
Issued 27 August 2001 Resolved
Label chemical sample locker IAW 46 CFR 153.935(a)(1) designating space as such within 30 days.
Condition: Unknown
Due 19 October 2001
Resolved 19 October 2001
Lifesaving
Issued 27 January 2000 Resolved
Service all EEBAs and SCBAs. Provide servicing certificate IAW IBC 14.2.6.
Condition: Unknown
Due 28 May 2000
Resolved 28 May 2000
Deck/Cargo
Issued 17 June 1992 Resolved
Demonstrate proper operation of the Inert Gas Generator prior to carrying cargoes in the U.S. that are required to be inerted.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Deck/Cargo
Issued 1 April 1989 Resolved
PROVIDE TO [name withheld], TX CLASS SOCIETY VERIFICATION THAT AN IGS WITHOUT A WATER SEAL COMPLIES WITH SOLAS 1974, REG 62. NO CARGOES REQUIRING INERT- ING TO BE CARRIED IN U. S. WATER TILL DEFICIENCY IS CLEARED.
Condition: Unknown
Due 1 April 1989
Resolved 1 April 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.