MAURY USCG vessel records
← All vessels

BAREFOOT QUEEN

BAREFOOT QUEEN is a 1989 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in April 2026, along with 50 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 17 April 2026.

Built
1989
Last inspected
17 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

324405
Flag
UNITED STATES
Maury page id
psix-324405

Documentation record

Tonnage as PSIX records it58 - Simplified, Net Ton
72 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 22

17 April 2026 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8341118
21 May 2025 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8142112
15 July 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7960540
23 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7853509
17 October 2023 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7809860
17 October 2023 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7811701
7 June 2023 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7706673
20 July 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7500966
8 June 2022 Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7472611
5 November 2021 Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7347188
19 April 2021 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7176030
22 September 2020 Administrative Inspection · Deadweight Survey
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7073958
11 August 2020 Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7030181
20 July 2020 Annual Inspection · DAPI Audit · In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6998173
29 January 2020 Examination of Repairs · Plan Review "T" Boat · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6899277
28 October 2019 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6843960
26 June 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6725915
29 May 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6420247
1 November 2017 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6298411
1 May 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6110763
23 August 2016 Administrative Inspection · Spot Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5987797
19 April 2016 Deficiency Check · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5857919

Deficiency record · 50

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 October 2023 Resolved
Failure to make the vessel available for annual inspection within 3 months before or after the anniversary date of issuance of the COI. Vessel did not schedule the Annual Inspection within the required dates and went past the 90 days over the anniversary date on the COI of April 19, 2022.
Action required: 10 - Deficiency Rectified
Resolved 17 October 2023
Resolution: Conducted satisfactory Annual Inspection 17OCT23
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 October 2023 Resolved
Failure to be in compliance with the terms of the COI when operating with passengers onboard. Vessel operated with passengers from April 20, 2023 until October 17, 2023 without undergoing the required Annual inspection.
Action required: 10 - Deficiency Rectified
Resolved 17 October 2023
Resolution: Completed Annual Inspection on 17OCT23.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 July 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. The vessel's fixed CO2 system in the engine space was not currently serviced.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 July 2022
Resolution: System was serviced by Pye Barker Fire and Safety.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2022 Resolved
Life preserver stowage must be properly marked with the number and type of PFD. Life preserver stowage on the vessel was improperly marked or missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 July 2022
Resolution: PFD locations properly marked
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2022 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Adult and child PFDs on the vessel were stowed in the same location.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 July 2022
Resolution: Child PFDs were moved to the bow of the vessel in their own stowage location
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. The vessel was missing twenty-four(24) adult life jackets and (1) child life jacket. Passenger count is reduced to one hundred and twenty-six (126) adults until new PFDs are provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 July 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Existing first aid kit was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
Resolution: New first aid kit provided
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 July 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot [name withheld] List, tides and currents tables. All publications were outdated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
Resolution: New publications printed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 July 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the Navigation Rules. Forward mast light was not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
Resolution: new bulbs provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2022 Resolved
Electrical equipment on a vessel must be of suitable construction and corrosion-resistant and suitable for the roll, pitch, and vibration of the vessel underway. Battery chargers in the engine room were not marine type and were not secured as to prevent movement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
Resolution: new marine battery chargers properly installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2022 Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Provided receptacles were made with plastic, open bottoms.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
Resolution: metal receptacles provided
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2022 Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Remove plastic engine crank case catch cans and replace with non combustible material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
Resolution: switched to metal
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 July 2022 Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made. Speakers on the bow were not operable. Ensure public announcements can be heard throughout the entire vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
Resolution: PA system was figured out and is operational
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2022 Resolved
The control cabinets or spaces containing valves, manifolds or controls for the various fire extinguishing systems must be marked in conspicuous red letters at least 2 inches high. Properly mark fire hydrants.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
Resolution: hydrants properly marked
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 July 2022 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent. CO2 system diagram was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 June 2022 Resolved
For portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure test required by CH 4 of NFPA 10 with the frequency specified in NFPA 10. Fire extinguishers were missed annual servicing by a year. The last servicing date by Pye Barker was Jun 2020.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 June 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2021 Resolved
Repairs to the vessels deck shall not be made without the approval of the cognizant [name withheld] main deck planking in way of the vessels bow requires repair due to damage(s)/rot (soft spots). Owner/Operator to submit repair proposal to OCMI prior to commencing repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2021
Resolved 22 July 2022
Resolution: Proper repairs made to structures and tested with water hose.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2021 Resolved
Vessel required to be equipped with draft marks or loading marks. Vessel is not equipped with any type of draft/loading marks as outlined in its stability letter.
Action required: 705 - Other - as specified
Due 31 December 2021
Resolved 8 June 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 April 2021 Resolved
Vessel required to display navigational side lights between sunset & sunrise and in periods of restricted visibility. Existing navigational side lights were inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2021
Resolved 3 May 2021
Resolution: Attending Inspector(s) witnessed operation of navigational side lights.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 April 2021 Resolved
Vessel required to be equipped with fire detections system for machinery space. Existing fire detection system requires servicing/re-certification.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2021
Resolved 3 May 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 April 2021 Resolved
Vessel required to be equipped with emergency fuel shut-off valves with operating instructions. Existing fuel shut-off valves are missing operating instructions (direction of operation).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 3 May 2021
Resolution: Attending Inspector(s) verified installation of markings for emergency fuel shut-off valves.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 April 2021 Resolved
Vessels emergency escapes are required to be marked/identified. Existing emergency escape paths in way of the upper deck are not properly marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 3 May 2021
Resolution: Attending Inspector(s) verified markings for emergency escapes.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 December 2020 Resolved
Whenever machinery is installed on board a vessel as replacement equipment or as a new installation, the owner shall conduct the tests and make the vessel ready for the required inspections to the satisfaction of the [name withheld] testing the newly installed electric submerisble bilge pumps, attending Inspector noted that the starboard pump IWO machinery space/engine room was constantly short cycling. Further inspection identified water intrusion IWO port & starboard butt blocks, outboard of keel between the ships service diesel generators.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2021
Resolution: Attending Inspector(s) monitored/verified condition of water ingress IWO butt blocks. No further water intrusion was noted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2020 Resolved
Marine Employer is required to implement chemical testing program for crewmembers that serve in a safety senstive function on board the vessel. Marine Employer has not implemented the required chemical testing program IAW 46 CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2020
Resolution: Attending Inspector verified implementation of chemical testing program.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 July 2020 Resolved
Vessel is required to be fitted with emergency lighting. Existing emergency lighting was inoperable at time of inpsection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2020
Resolution: Attending Inspector verified operation of emergency lighting.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 July 2020 Resolved
Vessel required to be fitted with power driven fire pump. Through hull valve IWO starboard side shell (planking) for fire pump overboard discharge was seized.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2020
Resolution: Attending Inspector verified operation of fire pump and verified operation of thru-hull valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 July 2020 Resolved
Vessel's electric submersible bilge pumps are required to be listed by an independent laboratory meeting UL 1113. Vessels newly installed electric submersible bilge pumps do not meet UL 1113 requirements.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 22 December 2020
Resolution: Attending Inspector verified installation of electric submersible bilge pumps.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 July 2020 Resolved
Vessels means of escapes are required to be marked/labeled. Existing emergency escapes are not properly marked/labeled ("EMERGENCY ESCAPE KEEP CLEAR").
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified markings for emgergency escape(s).
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 July 2020 Resolved
Vessel required to be fitted with bilge high water alarms. Vessels bilge high water alarms IWO operators station are not properly marked to identify compartment/void served.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified markings for bilge high water alarms.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 July 2020 Resolved
Vessel required to be fitted with ventilation closures if fixed fire fighting system is installed. Existing ventiliation closures require adjustment to ensure proper sealing (machinery space/engine room).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 22 December 2020
Resolution: Attending Inspector verified operation of ventilation closures for machinery space/engine room.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 July 2020 Resolved
Fixed fire fighting installation requires operating instructions. Existing operating instructions IWO operators station (remote pull) are inadequate. Local operating instructions @ bottles are missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified posting of operating instructions for local/remote pull stations for fixed CO2 system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 July 2020 Resolved
Exhaust systems for engines (machinery) are required to be water cooled. Existing flexible cooling water hose IWO starboard SSDG was found deteriorated (outer jacketing).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified renewal of flexible cooling hose IWO starboard SSDG.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 July 2020 Resolved
Power driven fire pump is required to be fitted with a pressure gauge as the discharge side of the pump. Existing power driven fire pump installation does not have a pressure gauge installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 22 December 2020
Resolution: Attending Inspector verified operation of fire pump and pressure gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020 Resolved
The scope of an annual inspection is the same as the inspection for certification. It includes inspection and testing of machinery components. Pitting noted IWO aluminum exhaust piping for main diesel engines and generators @ flexible hose connections. Affected areas to be monitored at subsequent inspections. Permanent repairs to be effected NLT next scheduled DD/ISE inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 June 2022
Resolution: Updated special note for permanent repairs to be completed at next drydock in 2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020 Resolved
Vessels steering system shall be of adequate strength and capable of steering the vessel at all service speeds. Flexible steering hoses (supply/return) was found leaking @ crimped coupling IWO lazarette.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified repairs made to steering system flexible hose connections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020 Resolved
The scope of an annual inspection is the same as the inspection for certification to ensure the vessel is fit for service and routes intended. The port bearing assembly for paddlewheel shaft was found fractured/wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2020
Resolution: Attending Inspector verified renewal of port/starboard bearing assemblies for paddlewheel.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 July 2020 Resolved
Vessels compass required to be illuminated. Vessels magnetic compass light was extinguished at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified illumination of compass.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2020 Resolved
Vessel required to have emergency instructions posted. Exisitng emergency instructions are incomplete.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified posting of emergency instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2020 Resolved
Vessel required to post PFD donning instructions at/near stowage locations. Vessel missing PFD donning instructions/placards at/near stowage locations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified posting of PFD donning instructions.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2020 Resolved
Each connection of a conductor shall be made within an enclosure. "Dead ended" wiring noted IWO starboard overhead deck beam in fwd storage comparment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified termination of dead ended wiring IWO fwd compartment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2020 Resolved
Conductors are required to be installed with metal supports spaced not more than 24" apart. Existing conductor(s) IWO fwd storage compartment overhead are not properly secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified installation of supports for overhead conductors IWO fwd. compartment.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 July 2020 Resolved
Watertight hatches are required to be marked "WATERTIGHT HATCH KEEP CLOSED". Existing watertight hatch IWO forepeak is missing required markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified markings for main deck watertight hatch (forepeak)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 20 July 2020 Resolved
Vessel with installed toilets are required to have an approved marine sanitation device installed. Existing Type III MSD (tank) shows signs of a previous weld repair (outboard, stbd side near top). Clean exterior of tank and check for leaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 11 August 2020
Resolution: Attending Inspector(s) verified condition of MSD holding tank.
Construction/Loadline › Structures › Superstructure
Issued 1 May 2017 Resolved
AB01: Vessels owner/operator must fix STBD main bearing braket on the paddle wheel. This could become a vessel & personel hazard. Prior to Carrying Passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 3 May 2017
Resolution: Replaced with new.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 April 2016 Resolved
Prove proper operation of DSC radio
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 April 2016 Resolved
Replace stern and mast head light and lens. May not operate in low light and/or night time operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector
Engineering › Fuel Oil Service System › Piping
Issued 20 April 2016 Resolved
Properly mark fuel shut offs valves as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 5 May 2016
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 20 April 2016 Resolved
Provide drug awarness training with crew and document.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 April 2016 Resolved
Crew member [name withheld] is out of DAPI compliance and not currently enrolled, he may not act as a crew member.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 April 2016 Resolved
Replace reto tape on 12 adult life jackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 5 May 2016
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.