MAURY USCG vessel records
← All vessels

FIRST CAST

FIRST CAST is a 2000 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2017, most recently in April 2026, along with 18 deficiencies and 1 casualty investigation in 2009.

Records from 2009 to 2026. Most recent: inspection, 21 April 2026.

Built
2000
Last inspected
21 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK6850
Flag
UNITED STATES
Maury page id
psix-32453

Documentation record

Registered dimensions (L × B × D)41.0 ft × 14.0 ft × 7.0 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMORGAN BOATS INC · NAPLES, FL, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 10 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

21 April 2026 Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8353477
17 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8113513
10 April 2025 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8110229
8 April 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8109792
30 December 2024 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8051889
1 February 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7851716
19 January 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7624073
8 December 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7606195
25 March 2022 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7418575
25 February 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7402102
3 February 2021 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7135860
13 January 2021 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7123731
19 February 2020 Type not recorded
No type recorded · USCGC ALBACORE (WPB 87309) · USCG Northeast District (CGD-NE) · Activity 6917162
3 February 2020 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6901889
11 February 2019 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6623511
9 January 2019 Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6607969
26 February 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6360179
13 December 2017 Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6320864
6 March 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6098288

Deficiency record · 18

11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 1 February 2024 Resolved
Vessel restrcied to limited coastwise route until expired hydrostatic release for EPIRB is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 January 2025
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 February 2024 Resolved
Vessel is restrcited to limited coastwise route until all Type I PFD waterlights are operational. Five (05) were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 January 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2023 Resolved
Inspect remote fuel cut-offs in accordance with 46 CFR 176.804. Satisfactory emergency fuel cut-off arrangement could not be verified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2023
Resolution: Owner demonstrated remote fuel cut-off valves operation and labeled as needed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 February 2022 Resolved
Maintain DAPI Program in accordance with 46 CFR 16. Alcohol test strips were not provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2022
Resolved 25 March 2022
Resolution: Strips provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 February 2022 Resolved
Label lifesaving equipment in accordance with 46 CFR 185.604. Life buoy was not labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2022
Resolved 25 March 2022
Resolution: Life buoy labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 25 February 2022 Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. Life float is in need of renewal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 25 March 2022
Resolution: Life float renewed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 February 2022 Resolved
Inspect fire equipment in accordance with 46 CFR 176.810. Pre-engineered fire cylinder was corroded. Renew by next annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 January 2023
Resolution: Owner supplied proof of ordered bottle from fire service company. FSC will install and test upon installation. Owner to provide proof of completion.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 February 2021 Resolved
Provide proof of Fire-Fighting servicing report.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 5 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 February 2021 Resolved
Provide proof of updated Navigational Publications (Light List, Notice to Mariners, Navigation Rules, and Coast Pilot).
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 3 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2021 Resolved
Provide a life jacket dawning placard for all life jacket types.
Action required: 10 - Deficiency Rectified
Resolved 3 February 2021
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 February 2020 Resolved
Provide Proof of Valid FCC Operators Permit
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2020
Resolved 12 February 2020
Resolution: Recieved proof of temp FCC Operators Permit.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 February 2020 Resolved
Provide proof of Valid FCC Safety Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2020
Resolved 27 February 2020
Resolution: Received proof of FCC safety cert.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 February 2020 Resolved
Provide proof of correct call sign on EPIRB Registration
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2020
Resolved 12 February 2020
Resolution: Received proof of proper EPIRB registration.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 February 2020 Resolved
Provide proof that all crew is enrolled in DAPI Program.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2020
Resolved 26 February 2020
Resolution: Received proof of DAPI enrollment
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 December 2017 Resolved
Rewire/secure wires for the stern underwater lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 26 February 2018
Resolution: wires were secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 December 2017 Resolved
Submit Plans/Details for the stern underwater light for approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 26 February 2018
Resolution: Wiring was returned to orginal.
Construction/Loadline › Hull › Bottom Plating
Issued 13 December 2017 Resolved
Repair 3 through hulls (owner is closing them) Fiberglass repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2017
Resolved 26 February 2018
Resolution: Fiberglass repairs were conducted and inspected my USCG marine inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 6 March 2017 Resolved
Cover hole in aft engine room bulk head.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 12 April 2017
Resolution: holes were repaired.

Casualty record · 1

5 March 2009Routine · role: Involved in a Marine Casualty · activity 3428656
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

RUMRUNNER III (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.