MAURY USCG vessel records Sign in
← All vessels

VIRGINIA DARE

VIRGINIA DARE is a 1989 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1989, most recently in May 2026, along with 101 deficiencies and 1 casualty investigation in 2017.

Records from 1989 to 2026. Most recent: inspection, 27 May 2026.

Built
1989
Last inspected
27 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL7613
324532
Flag
UNITED STATES
366781580
Maury page id
psix-324532

Inspections, by type

…with no type recorded1
Years with a record 32 calendar years (1989–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.3 ft × 20.1 ft × 3.8 ft
Registered tonnagegross 38 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES · LA CROSSE, WI, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Net Ton
38 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL7613MMSI 366781580 · active · compulsorily equipped · granted 11 September 2020, expires 11 September 2030
WCZ8056MMSI 366781580 · expired · compulsorily equipped · granted 30 March 2010, cancelled 11 July 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

27 May 2026 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8330208
13 May 2025 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8135354
16 May 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7913255
29 April 2024 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7902732
25 July 2023 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7752147
26 April 2022 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7435339
22 March 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7420269
12 July 2021 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7334765
24 June 2021 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7221184
13 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6985372
26 June 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6719363
10 April 2018 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6385272
1 September 2017 In-Service Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6259720
28 August 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6264408
11 May 2017 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6159865
9 May 2017 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6073548
24 May 2016 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5873702
5 August 2015 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5197602
21 October 2008 DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3348646
17 September 2008 DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3330660
28 July 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3302216
5 June 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2954280
30 March 2007 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2898486
26 April 2006 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2633769
9 May 2005 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2352881
6 July 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2109229
14 April 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1773389
10 July 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1641417
26 February 2002 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1490177
9 May 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1064923
12 April 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1454928
17 July 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1389143
26 August 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 781522
13 May 1999 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1447953
27 May 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 792131
20 April 1998 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1471675
13 June 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 776031
8 May 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1396721
25 March 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1335506
27 February 1997 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1368070
20 May 1996 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1082141
30 April 1996 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1080202
15 April 1996 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1424215
24 April 1995 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1380194
23 February 1995 Drydock Extension · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1392169
27 June 1994 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 861943
23 May 1994 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1464523
22 April 1993 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 837054
9 April 1993 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 840436
20 July 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1255218
24 April 1992 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 951202
17 July 1991 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1252542
15 May 1990 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 899546
26 April 1989 Plan Review "T" Boat · Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1033459

Deficiency record · 101

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2026 Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. MI observed life buoy was in non-serviceable condition, informed o/o to replace life buoy. 46 CFR 180.70(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 June 2026
Resolution: Received photo evidence of new life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2025 Resolved
All machinery must installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. A leak was observed at the fuel pump supplying the vessel’s generator. //46 CFR 182.01-5//
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2025
Resolution: MI received video of satisfactory functioning fuel pump with no leak.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. The circuit directory on the vessel’s aft switchboard did not accurately reflect the connected loads. //46 CFR 183.01-15//
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2025
Resolution: MI received picture of updated circuit directory on switchboard.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 13 May 2025 Resolved
A ship, except a ship of less than 26 feet in length, must have a Discharge of Oil Prohibited placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station. Vessel's Oil Pollution Placard was mounted at the operating station. //33 CFR 155.450(a)//
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2025
Resolution: MI received objective evidence of installed oil pollution placard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Each first-aid kit must meet the requirements in ISO 18813:2006(E) paragraph 4.12. A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12, except that it does not contain the burn preparations. It must be clearly marked on the first-aid kit that it does not include the burn preparations. Vessel's first aid kit did not have 10 sterile compression bandages for wounds in assorted sizes and was not clearly marked that it did not include the burn preparations. //46 CFR 184.710// //46 CFR 199.175(b)(10)//
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2025
Resolution: MI received objective evidence of burn pads and the first aid kit being marked it does not have burn gel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2025 Resolved
All portable fire extinguishers installed on vessels shall be of an approved type. Two of the vessel’s extinguishers—located on the starboard side outside the pilothouse, and aft of the pilothouse—were not mounted in approved brackets. //46 CFR 181.30-5//
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 June 2025
Resolution: MI received objective evidence of approved brackets on fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. The vessel was required to have 85 adult life jackets on board as specified in its COI but only 82 were available at the time of inspection. //46 CFR 180.71//
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
Resolution: Vessel acquired and marked 03 lifejackets.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 May 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Three electrical installations onboard were found using extension cord-type devices or multi-outlet adapters. One was located on the upper passenger deck and two were located in the galley. //46 CFR 183.01-15//
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
Resolution: Vessel removed additional electrical installations.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 May 2025 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information: date of the training; and general description of the training topics. Vessel had no record of crew training. //46 CFR 185.420//
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
Resolution: Vessel properly logged crew training from 12MAY2025.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 May 2025 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Drills shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: date of the drill and general description of the drill scenario. Vessel’s drill records did not include the general description of the drills. //46 CFR 185.520//
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
Resolution: Vessel correctly logged drills from 12MAY2025.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 May 2025 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Drills shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: date of the drill and general description of the drill scenario. Vessel’s drill records did not include the general description of the drills. //46 CFR 185.524//
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
Resolution: Vessel correctly logged drills from 12MAY2025.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2025 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Vessel’s portable watertight container was not marked. //46 CFR 185.615//
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
Resolution: Vessel marked distress signal container.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 May 2025 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] emergency exit sign was not labeled correctly. //46 CFR 185.606//
Action required: 10 - Deficiency Rectified
Resolved 13 May 2025
Resolution: Vessel labeled window exit correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 April 2024 Resolved
A vessel on a lakes, bays, and sounds route must carry three hand red flare distress signals and three hand orange smoke distress signals approved in accordance with 46 CFR 160.021 or other standard specified by the Commandant. Vessel was missing 02 hand orange smoke distress signals. 46 CFR 180.68(b)(1),(2). Vessel Limited to within 30 minutes of the dock.
Action required: 705 - Other - as specified
Resolved 13 May 2024
Resolution: Photographic evidence of proper equipment received.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 April 2024 Resolved
The owner, master or managing operator shall instruct each crew member at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Vessel had no record of crew training. 46 CFR 185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Photographic evidence of proper training received.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 April 2024 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Vessel had no record of drills. 46 CFR 185.520(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Photographic evidence of drills received.
01 - Certificates & Documentation › 013 - Documents › Declaration of AFS compliance
Issued 29 April 2024 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Vessel had no record of drills. 46 CFR 185.524(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Photographic evidence of drills received.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 April 2024 Resolved
Each lifeline on a ring life buoy must be of at least 60 feet in length. Lifeline attached to vessel's ring life buoy was less than 60 feet long. 46 CFR 180.70(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Photographic evidence of proper equipment received.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2024 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible. All pages of COI were not posted. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Photographic evidence of proper posting of COI received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2024 Resolved
Each item of lifesaving equipment carried on board a vessel but not required under this part must be approved by the Commandant. Decorative ring life buoy is not approved lifesaving equipment. 46 CFR 180.25(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Photographic evidence of proper equipment received.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 29 April 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions taken in the event of fire, heavy weather, or man overboard conditions. Vessel's man overboard emergency instructions did not match new procedures. 46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Photographic evidence of proper documentation received.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect the vessel from electrical hazards caused by or originating in electrical equipment. Vessel had uncapped wires below operating station in pilothouse. 46 CFR 183.200(b)
Action required: 10 - Deficiency Rectified
Resolved 30 April 2024
Resolution: Wires capped.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 July 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was lacking 05 adult life jackets. Total persons restricted 80. 46CFR180.71(a)
Action required: 705 - Other - as specified
Resolved 4 August 2023
Resolution: O/O purchased 05 new jackets.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 25 July 2023 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] generator battery had low voltage and generator would not start. 46CFR183.01-15
Action required: 10 - Deficiency Rectified
Resolved 25 July 2023
Resolution: O/O fixed loose alternator belt.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 July 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Steering compartment's visual high water alarm was not illuminating. 46CFR182.530(a)
Action required: 10 - Deficiency Rectified
Resolved 25 July 2023
Resolution: O/O replaced high water alarm on bridge.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2023 Resolved
Portable fire extinguishers installation and location must be to the satisfaction of the [name withheld] deck accommodations space fire extinguisher was not mounted in a bracket. 46CFR181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 4 August 2023
Resolution: Replaced bracket
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 July 2023 Resolved
Each vessel must be equipped with at least two operable portable battery operated lights. Vessel did not have any portable lights on board. 46CFR183.430
Action required: 10 - Deficiency Rectified
Resolved 25 July 2023
Resolution: O/O provided 02 battery operated portable lights for vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 26 April 2022 Resolved
A vessel must carry either a first aid approved under approval series 160.041 or a kit with equivalent contents and instructions. Eyewash and Aspirin were expired. 46CFR184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 14 May 2022
Resolution: Vessel owner purchased new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2022 Resolved
Each ring life buoy with a floating water light must be secured around the body of the ring life buoy. Floating water light was not secured around the body of the life ring. 46CFR180.70(d)(2)
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: Vessel secured float light around the body of the life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2022 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46CFR164.018. Ring life buoy's retroreflective tape was worn and nonserviceable. 46CFR185.604(h)(i)
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: Vessel replaced retroreflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2022 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets on main deck were mixed together with adult and not properly labeled on container. 46CFR180.78(a)(5)
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: Child life jackets were separated with a carboard placed inbetween. Number of child life jackets were labeled on closet containing them.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2022 Resolved
The number and identification of the items stowed inside and their sizes must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at east 2 inches high. Life jacket container on main deck reflected wrong number of adult life jackets. 46CFR185.604(f)
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: O/O properly labled container with correct number of adult lifejackets contained.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. One lifejacket was found unserviceable and was destroyed in the presence of the MI. 46CFR180.71(a)
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: Life Jacket was destroyed in presence of MI and replaces with new PFD.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 April 2022 Resolved
Main distribution panels must be of the dead front type. Vessels center leg neutral panel had two missing breakers. 46CFR183.10-15
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: O/O covered missing breakers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021 Resolved
Each distrobution panel or switchboard must be totally enclosed and of the dead front type; center leg box (left) latch inop, replace to ensure dead front.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 12 July 2021
Resolution: latch replaced on distrobution panel to meet standard
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021 Resolved
Battery must be free from exposure to water, splash, or spray and shifting; 2 of 3 bateries in engine space missing lid; replace to meet standard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 12 July 2021
Resolution: battery box covers supplied for 2 of 3 batteries in engine space to meet standard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 June 2021 Resolved
Each waterlight must meet approval standards; battery installed does not meet manufacturer requirements; replace to meet standard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 12 July 2021
Resolution: replaced waterlight battery to meet manufacturer requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2021 Resolved
The number and identification of the items stowed inside and their sizes must be marked clearly and legibly; top deck storage capacity incorrect for adult lifejackets; adjust to reflect accordingly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 18 October 2021
Resolution: owner/operator updated number of life jackets to reflect those posted by their placard to meet standard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 June 2021 Resolved
As appropriate for the intended voyange, a vessel must carry adequate and up to date charts; charts cannot be verified as current or up to date; furnish charts with printed date or demonstration of update.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 12 July 2021
Resolution: supplied updated charts for operational area.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2021 Resolved
An adult lifejacket must be provided for each person carried onboard a vessel; one adult lifejacket wasted; destroyed in presence of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 June 2021
Resolved 24 June 2021
Resolution: destroyed in the presence of the marine inspector
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2021 Resolved
Each life jacket must be marked with Type I retroreflective material; retro wasted; replaced wit approved tape.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 June 2021
Resolved 24 June 2021
Resolution: replaced with approved tape in the presence of the marine inspector
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 June 2021 Resolved
Vessel must have a visual and audible alarm to indicate high water level in machinery space; alarm inop; replaced and retested successfully.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 June 2021
Resolved 24 June 2021
Resolution: alarm replaced and successfully retested.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 June 2021 Resolved
Vessel on Lakes, Bays, and Sounds route must have flares (3 red and 3 orange) to meet subchapter Q requirements; expired flares kept onboard in white emergency flares box; removed from vessel.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 24 June 2021
Resolved 24 June 2021
Resolution: Removed from vessel
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Found 35 adult life jackets unserviceable. Limit number of passengers to be carried to 80. Replace life jackets to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 11 September 2020
Resolution: Vessel representative provided proof of purchase of 35 new adult life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 July 2020 Resolved
A vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible. Found vessels charts out of date. Replace with new chart for area of operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 15 July 2020
Resolution: Vessel operator provided proof of an updated chart. Picture uploaded in the documents.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 11 September 2020
Resolution: Vessel representative provided new call sign, updated MISLE file to reflect.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 July 2020 Resolved
Distress signals shall be limited to a period of 3 years from the date of manufacture. Found expired distress flares for vessel. Replace with new flares prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2020
Resolved 15 July 2020
Resolution: Vessel operator provided proof of new flares in vessel. picture of flares uploaded into documents.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 13 July 2020 Resolved
Found wire on top deck leading to a power supply not secured. Secure wire with appropriate metal banding every 24 inches to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 14 July 2020
Resolution: Vessel operator secured wire to the satisfaction of the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2019 Resolved
MIssing portable hand bilge pump.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2019 Resolved
Lifebuoy waterlight inoperable, replace/repair.
Action required: 705 - Other - as specified
Due 10 July 2019
Resolved 28 June 2019
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 26 June 2019 Resolved
Found leak in sewage piping inlet to MSD holding tank; repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 28 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 June 2019 Resolved
Found 01 portable fire extinguisher missing bracket. Provide bracket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 27 June 2019
Fire Fighting › Fire Main › Condition
Issued 10 April 2018 Resolved
All pipes and marine fittings must be suitable for the purpose intended. Vessels fire main is leaking at joint fitting. 46 CFR 181.15-5(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2018
Resolved 11 April 2018
Resolution: Fire main joint fitting cleaned and tightened, conducted satisfactory operationl fire main test; cleared CG-835 item# 1.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 10 April 2018 Resolved
Vessel with installed toilet facilities must have a MSD in compliance with 33 CFR 159. MSD fill pipe is detaching from tank causing the MSD to leak. 46 CFR 184.702
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2018
Resolved 11 April 2018
Resolution: Leveled tank and properly sealed fill pipe; cleared CG-835 item# 2.
Engineering › Bilge Water Management System › Interface Detector
Issued 10 April 2018 Resolved
Machinery and equipment installed on each vessel must be suitable for its operation and the purpose intended. Forward bilge high level alarm not permanently installed. 46 CFR 182.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2018
Resolved 11 April 2018
Resolution: Permanently installed forward high level bilge alarm; cleared CG-835 item# 3.
Engineering › Thrusters › Seal
Issued 1 September 2017 Resolved
Flooding into the bow thruster space due to shaft seal failure. Make proper repairs to bow thruster system and align shaft seal. Conduct operational underway test in the presence of attending marine inspector. 46 CFR 176.840
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2017
Resolved 2 September 2017
Resolution: Vessel hired technician to properly align bow thruster shaft seal. Proper operation of the bow thruster was verified by the attending marine inspector during underway operational test.
Communications › Alarms/Indicators › High Water Alarm
Issued 1 September 2017 Resolved
Wiring to high level bilge alarm in bow thruster space is severed. Each machinery space must be fitted with an operational high level bilge alarm that gives a visual and audible alarm at the operating station. Make proper repairs. Test in the presence of attending marine inspector. 46 CFR 182.530(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2017
Resolved 2 September 2017
Resolution: Vessel hired technician to repair electrical wiring of the high level bilge alarm in the bow thruster space. Crew conducted a satisfactory operational test of the bilge system and the corresponding high level alarms.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 17 September 2008 Resolved
Serious Marine Incident testing not arranged, company does not have Alcohol testing kits onboard to test within 2 hrs. Were never made aware of the ruling.
Due 28 October 2008
Resolved 21 October 2008
Resolution: Company submitted documentation for proof of ordering Alcohol testing kits and place to test urine in case of a serious marine incident.
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 17 September 2008 Resolved
Supervisors have not been properly trained on how to identify potential reasonable suspicion personel.
Due 28 October 2008
Resolved 21 October 2008
Resolution: Supervisors have received one hour training.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 17 September 2008 Resolved
Hotline Numbers not available;
Due 28 October 2008
Resolved 21 October 2008
Resolution: Company produced documentation for EAP information.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 September 2008 Resolved
Crewmembers need to receive proper training prior to assuming safety sensitive positions on Alcohol awareness and company policy.
Due 28 October 2008
Resolved 21 October 2008
Resolution: Crew members have been trained as of 10/11-12/08
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 17 September 2008 Resolved
Failure to submit Management Information Systems report. Company in business for 14 yrs has not submitted a report, owner admits not aware of this responsibility.
Due 28 October 2008
Resolved 21 October 2008
Resolution: Company will be responsible to submit a Management Information Systems report for this year in 2009.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 28 July 2008 Resolved
Provide proof of pre-employment drug testing for all crewmembers Prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2008
Resolution: Provided proof of chemical testing with negative results for crewmembers.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 June 2007 Resolved
Remove "rope" lighting. (Not UL 595).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 28 July 2008
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 5 June 2007 Resolved
Renew both L/O cooler lines on the port main engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 28 July 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2003 Resolved
Replace expired meds. in first aid kit.
Due 15 May 2003
Resolved 21 April 2003
Stability › Watertight Integrity
Issued 26 February 2002 Resolved
Provide proof of replacement seal and strongback for forward access hatch. Deficiency may be cleared via fax receipt due to the distance between Smith Mountain Lake and MSO Hampton Roads.
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 9 July 2002
Engineering › Thrusters
Issued 26 February 2002 Resolved
Bow thruster shaft seal has small leak. Repair as original. Deficiency may be cleared with a fax receipt of work done due to the distance between Smith Mountain Lake and MSO Hampton Roads. LEGACY COMPONENT DESC: Seal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 12 July 2002
Lifesaving
Issued 12 April 2001 Resolved
PROVIDE PROPER FIRST AID KIT.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Documentation
Issued 12 April 2001 Resolved
PROVIDE PROOF OF ENROLLMENT IN RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Construction/Loadline
Issued 12 April 2001 Resolved
PROVIDE PORTABLE BILGE PUMP IAW 46CFR182.520
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Fire Fighting
Issued 12 April 2001 Resolved
PROVIDE PROPER PSI GAUGE FOR FIRE PUMP IAW 46CFR181.300.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 13 May 1999 Resolved
PROVIDE RETRO TAPE AS REQUIRED FOR LIFE RINGS AND INSTALL A CLIP TO ATTACH FLOAT LIGHT.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Electrical
Issued 13 May 1999 Resolved
REMOVE SOLID CORE WIRING AND REPLACE WITH STRANDED WIRING SIZED TO MANFACTURES SPECIFICATIONS.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Lifesaving
Issued 13 May 1999 Resolved
REPLACE 15 CHILD LIFE JACKETS.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Construction/Loadline
Issued 13 May 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS IN REQUIRED SPACES.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Lifesaving
Issued 20 April 1998 Resolved
PROVIDE RETROREFLECTIVE TAPE ON VESSEL'S LIFE RINGS.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Fire Fighting
Issued 20 April 1998 Resolved
REPLACE FIRE EXTINGUISHERS ON UPPER AND LOWER DECKS WITH TWO (2) B-II EXTINGUISHERS.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Electrical
Issued 20 April 1998 Resolved
INSTALL METAL WIRE SUPPORTS EVERY 24 INCHES ON ELECTRICAL LIGHTING RUN ON UPPER PASSENGER DECK.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Lifesaving
Issued 20 April 1998 Resolved
PROVIDE MECHANICAL HOLD BACK FOR HATCH COVER TO FUEL TANK VOID SPACE.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Electrical
Issued 20 April 1998 Resolved
REPLACE/REPAIR EXPOSED WIRE ON STARBOARD NAVIGATION LIGHT.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Construction/Loadline
Issued 8 May 1997 Resolved
REPLACE GASKET FOR FORWARD DECK HATCH.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Navigation
Issued 8 May 1997 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD ON BRIDGE.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Accommodation/Occupational Safety
Issued 27 February 1997 Resolved
PROVIDE MISSING SECURING BOLTS IN WAY OF SECOND DECK RAILING.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Construction/Loadline
Issued 27 February 1997 Resolved
PROVIDE SEA VALVES IN WAY OF THROUGH HULL FITTING THAT ARE WITHIN SIX (6) INCHES OF VESSEL'S WIND WATER LINE.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Electrical
Issued 15 April 1996 Resolved
REMOVE DEAD END WIRES I.W.O. BRIDGE CONSOLE.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Lifesaving
Issued 15 April 1996 Resolved
PROPERLY SECURE CO2 BOTTLES I.W.O. THIRD VOID SPACE.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Construction/Loadline
Issued 15 April 1996 Resolved
REWELD CRACKED WELD ON HATCH COAMING I.W.O. BOW THRISTER COMPARTMENT ENTRANCE.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Lifesaving
Issued 15 April 1996 Resolved
PROVIDE REQUIRED FLARES AND SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 29 April 1996
Resolved 22 April 1996
Documentation
Issued 15 April 1996 Resolved
PROVIDE PROOF OF PROPER DRUG TESTING PROGRAM.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Electrical
Issued 23 May 1994 Resolved
INSTALL COVERS ON TWO ELECTRICAL LIGHT FIXTURES LOCATED IN PORT SIDE MAIN DECK PANTRY.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Lifesaving
Issued 23 May 1994 Resolved
LABEL LOCATIONS OF ADULT & CHILDS LIFE PRESERVERS AND AMOUNTS ON UPPER DECK; LABEL LOCATION OF CHILDS LIFE PRESERVERS AND AMOUNT ON MAIN DECK.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Electrical
Issued 23 May 1994 Resolved
SECURE ELECTRICAL WIRE LEADING TO STBD SIDE ENGINE ROOM, FORWARD BULKHEAD, TO BULKHEAD RACEWAY.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 23 May 1994 Resolved
WELD HOLE IN AFT STEERING COMPARTMENT IN WAY OF TRANSOM/MAIN DECK. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 23 May 1994 Resolved
CROP AND RENEW BUCKLED TRANSVERSE FRAME LOCATED STBD SIDE, FIRST FROM AFT BKHD IN AFT STEERING COMPT; CROP AND RENEW THREE LONGITUDINAL FLAT BAR STIFFENERS LOCATED STBD SIDE IN WAY OF THE ABOVE BUCKLED TRANSVERSE FRAME.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 23 May 1994 Resolved
PROVIDE/INSTALL CAPTIVE CHAIN ON MAIN DECK FORWARD COMPARTMENT SCUTTLE.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 23 May 1994 Resolved
CROP AND RENEW THE BUCKLED TRANSVERSE FRAMES LOCATED STBD SIDE ENGINE RM FROM SIDESHELL TO LONGITUDINAL ENGINE GIRDER.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Documentation
Issued 22 April 1993 Resolved
PROVIDE EVIDENCE OF ENROLLMENT IN A DRUG TESTING PROGRAM FOR MEMBERS OF THECREW.
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Documentation
Issued 24 April 1992 Resolved
PROVIDE DOCUMENTED EVIDENCE OF ENROLLMENT IN THE RANDOM DRUG TESTING PRO-_x001C_ GRAM FOR ALL CREWMEMBERS.
Condition: Unknown
Due 24 April 1992
Resolved 24 April 1992
Documentation
Issued 24 April 1992 Resolved
PROVIDE VALID FCC RADIOTELEGRAPHY STATION LICENSE.
Condition: Unknown
Due 24 April 1992
Resolved 24 April 1992
Documentation
Issued 17 July 1991 Resolved
PROVIDE FSS SAFETY RADIOTELEPHONE CERTIFICATE
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991

Casualty record · 1

28 August 2017Routine · role: Involved in a Marine Casualty · activity 6264408
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.