BETSY ANN

BETSY ANN is a 1989 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1989, most recently in May 2023, along with 104 deficiencies and 1 casualty investigation in 2007.

Records from 1989 to 2023. Most recent: inspection, 15 May 2023.

Built
1989
Last inspected
15 May 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ9394
324892
Flag
UNITED STATES
367146960, 368470780
Maury page id
psix-324892

Inspections, by type

…with no type recorded6
Years with a record 31 calendar years (1989–2023)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 24.0 ft × 5.9 ft
Registered tonnagegross 65 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPALATKA SHIPBUILDING · PALATKA, FL, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLAFITTE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9394MMSI 368470780 · active · voluntarily equipped · granted 29 April 2026, expires 29 April 2036
WDJ8089MMSI 367146960 · active · compulsorily equipped · granted 15 November 2017, expires 15 November 2027
WDD4611MMSI 367146960 · expired · compulsorily equipped · granted 31 October 2006, cancelled 31 December 2016
WCF7448MMSI not assigned · expired · compulsorily equipped · granted 12 May 1994, cancelled 18 July 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 61

15 May 2023 COI Inspection · Construction Oversight · Internal Structural Exam · In-Service Inspection · Inclining Experiment · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7689106
10 May 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7683780
15 November 2022 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7571529
18 January 2022 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7382024
9 November 2021 Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7347893
19 August 2021 Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7294669
4 February 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7135996
14 January 2021 Examination of Repairs · Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7125102
3 February 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6901668
7 January 2020 Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6874676
6 May 2019 Administrative Inspection · Deficiency Check · Permit to Proceed · Examination of Repairs · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6678257
14 December 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6597748
22 December 2017 Deficiency Check · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6328017
28 November 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6313957
24 October 2017 Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6294396
13 March 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6103599
13 February 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6087190
11 April 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5847220
16 November 2015 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5759038
21 December 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4209440
28 September 2010 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3858706
21 December 2009 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3653494
1 February 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3140382
8 December 2007 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3113042
11 October 2007 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3077715
14 November 2005 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2536612
11 July 2005 Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2431980
15 June 2005 Deficiency Check · Plan Review "T" Boat · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2398953
21 May 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2074395
18 June 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1808540
16 April 2002 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1602869
28 August 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1072804
2 July 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1067251
29 March 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1050075
24 January 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434978
13 April 1999 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1432097
6 April 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465391
29 September 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 784693
29 April 1997 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414793
3 October 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 683416
27 June 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 932514
22 April 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1080418
18 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 212756
18 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1374581
6 July 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 877785
20 March 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1438296
22 February 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1468772
13 July 1994 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 867563
17 June 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1326764
20 April 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 860171
28 January 1994 Drydock Extension · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1162411
25 March 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 683417
15 March 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151101
30 January 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 955357
29 April 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1213017
11 April 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1014286
18 March 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 922451
19 June 1990 Plan Review "T" Boat · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 921097
24 May 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 917689
23 January 1990 Initial Certification · Plan Review "T" Boat
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 925433
8 February 1989 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 926635

Deficiency record · 104

04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 15 November 2022 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions not posted. Provide evidence of posted instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 28 November 2022
Resolution: Received photo of mounted emergency instructions, see docs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 November 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit expired. Provide proof of a valid first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 5 December 2022
Resolution: Received photos of newly purchased first aid kit, see docs.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 November 2022 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Excessive hazardous/flammable material found in forward compartment. Provide evidence of removed hazardous/flammable material or provide evidence of use and proper storage of items in an approved paint locker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 13 December 2022
Resolution: [name withheld] chose to remove all hazmat from the vessel. Received photos of all hazmat moved to his storage facility and photos of the now SAT storage space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2022 Resolved
Fuel lines must be annealed tubing of copper, nickel-copper, or copper-nickel having a minimum wall thickness of 0.9 millimeters (0.035 inch) except that:(i) Diesel fuel piping of other materials, such as seamless steel pipe or tubing, which provide equivalent safety may be used;(ii) Diesel fuel piping of aluminum is acceptable on aluminum hull vessels provided it is a minimum of Schedule 80 wall thickness; and(iii) when used, flexible hose must meet the requirements of § 182.720(e). Hose on generator of unapproved type and one hose on the main generator showing signs of wearing and needs replacement. Provide evidence of proper replacement with approved hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 17 November 2022
Resolution: Photos sent of sat hoses, see docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 November 2022 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Unable to draw suction from voids 5 and 6. Provide evidence of functional bilge system prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2022
Resolution: Videos of proper suction from voids 5 & 6 provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2022 Resolved
Dead end wires are not permitted unless secured in a junction box. Provide evidence of proper stowage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 17 November 2022
Resolution: Received photos of dead end wires placed in junction box, see docs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 January 2022 Resolved
Top deck not marked for Max Passengers. Maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch at the entranceway to that deck. 185.602(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 28 January 2022
Resolution: Labeled top deck for Max Passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 January 2022 Resolved
Life jacket stowage area not labeled. Number and identification of items stowed inside and their sizes must be marked in clearly legible letters and numbers on each container for life jackets. 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 28 January 2022
Resolution: Labeled life jacket stowage area with number of Adult Life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 February 2021 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. The vessels generator experienced a casualty while conducting the inspection and was inoperable. Make generator operable and ready for inspection.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 January 2021 Resolved
Stern light was inoperable, make operable and enclose exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 February 2020 Resolved
Vessel's bilge system was inoperable in void spaces #2 and #4.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2020
Resolved 28 February 2020
Resolution: Vessel was able to take suction on bilge lines for void spaces #2 and #4.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2020 Resolved
Vessels fuel vlave pull cable was not suffeciently attached.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 28 February 2020
Resolution: Vessel better secured fuel shut off pull cable.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 February 2020 Resolved
Vessels port side nav light was inop.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 February 2020
Resolved 19 February 2020
Resolution: Vessel replaced bulb.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 19 February 2020 Resolved
Vessel was not logging pre-departure checks IAW 185.320
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 6 April 2020
Resolution: Vessel sent in documentation showing pre departure checks being carried out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2019 Resolved
Main propulsion shaft broken.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2019
Resolution: Replace shaft and align. conducted sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2019 Resolved
Main engine fuel shutoff valve at diesel tank was not stopping in the appropriate open and closed positions. Ensure stops for open and closed positions are functioning.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2019
Resolved 15 January 2019
Resolution: Owner tighted valve operating handle so that it would hit the stops and only rotate 90 degrees.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 January 2019 Resolved
RAYCOR fuel filters on both the main engine and generator did not have appropriate flame shield and drain plug. Provide suitable flame shield and metallic drain plug.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2019
Resolved 15 January 2019
Resolution: Owner provided photograph of newly installed flame shield and metallic drain plugs for both diesel engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2019 Resolved
Fuel drain valve on diesel fuel tank is missing a drain plug. Provide metallic drain plug to prevent possible leaks.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2019
Resolved 15 January 2019
Resolution: Owner provided metallic plug for fuel drain valve.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2019 Resolved
Remove dead end wires on main engine, in generator room, and in fuel shutoff cabinet. Wire connections can be made or terminated in junction boxes or removed completely.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2019
Resolved 15 January 2019
Resolution: Owner provide photograph showing that all dead end wires had been removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 January 2019 Resolved
Ammeter on switchboard was not properly functioning. Each generator over 50V must have a functioning voltmeteter and ammeter.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2019
Resolved 22 January 2019
Resolution: Ammeter was shown to be in proper working order
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 January 2019 Resolved
Main engine exhaust was missing lagging to protect crew from hot piping.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2019
Resolved 22 January 2019
Resolution: Owner provided photographs of newly installed exhaust lagging
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 December 2017 Resolved
Fuel shut off valve for main engine does not shut all the way.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2018
Resolution: New valve installed and tested.
Documentation › Certificates/Documents › Stability Letter
Issued 28 December 2017 Resolved
Needs valid stability letter onboard and posted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2018
Resolution: New stability letter was signed and delivered.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 28 December 2017 Resolved
Needs 17 additional PFD's to have enough for passenger count on COI.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: Life jackets were purchased and on board.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 December 2017 Resolved
Faded donning instructions and stowage lable on 2nd deck requires replacement.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: New donning instructions posted.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 December 2017 Resolved
Incorrect ring buoy light battery.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: Correct battery installed.
Engineering › Bilge Water Management System › Not Operational
Issued 28 December 2017 Resolved
A/C Pump room requires operational high water alarm.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: High water alarm repaired and working.
Engineering › Bilge Water Management System › Strainer
Issued 28 December 2017 Resolved
Wasted bilge suction basket in aft void requires replacement.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: New basket installed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 28 December 2017 Resolved
Hydraulic line on steering system requires replacement due to worn and ripped outer shield. Must meet J-1942 hose type.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: New approved hose installed.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 28 December 2017 Resolved
Post copy of emergency instructions in pilot house.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: Emergency instructions posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 December 2017 Resolved
Medical kit expired.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: New kit purchased.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 28 December 2017 Resolved
Master must complete DAPI supervisor training.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: DAPI supervisor training completed.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 December 2017 Resolved
Radio requires MMSI and GPS for DSC.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: New radio purchased with GPS and MMIS number done.
Fire Fighting › Combustible Materials › Stowage
Issued 28 December 2017 Resolved
Clean engine room and remove PIG mats.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: Pig mats removed and engine room cleaned.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 28 December 2017 Resolved
Provide means to recover an unconscious survivor from the water.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: New way of removing PIW has been purchased and on board.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 March 2017 Resolved
FCC license needs to be renewed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 13 March 2017
Resolution: Application for FCC license was provided to MI.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 March 2017 Resolved
Alcohol test strips were out of date
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 13 March 2017
Resolution: Alcohol test strips are ordered, vessel can meet the two hour requirement.
Stability › Intact Righting Energy › General
Issued 13 February 2017 Resolved
Waterballast was discovered during hull inspection, owner to remove water ballast and replace with led.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 13 February 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 February 2008 Resolved
Due to weather drill could not be conducted. Conduct crew drills.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 1 February 2008
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 1 February 2008 Resolved
Provide rescue ladder or platform for recovering unconscious person from water.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 March 2009
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 1 February 2008 Resolved
Provide storm rail or hand grab for crew members as they transit narrow walkway along side of vessel superstructure during mooring operations. Provide PFD for mooring operations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 22 March 2009
Stability › Weathertight Integrity › General
Issued 11 October 2007 Resolved
Found forepeak watertight access hatch heavily scaled, missing securing device and gasket. Service hatch and make watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2007
Resolved 12 October 2007
Documentation › Logs/Records › Logbook (official)
Issued 28 September 2005 Resolved
Establish training logbook to include required training and drills. 46 CFR 185.420.
Action required: 705 - Other - as specified
Resolved 29 September 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 September 2005 Resolved
Obtain updated navigation publications including charts, Coast Pilot [name withheld], tide tables, tidal current tables, and Inland Navigation Rules. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 28 October 2005
Resolved 29 September 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 September 2005 Resolved
Provide means for lifejackets to be stowed in a readily accessible location and evenly distribute throughout accommodation spaces for both upper and main decks. 46 CFR 180.78(a).
Action required: 705 - Other - as specified
Due 28 October 2005
Resolved 14 November 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 September 2005 Resolved
Provide proper approved stowage bracket for ring life buoy floating water light. 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 28 October 2005
Resolved 29 September 2005
Fire Fighting › Fire Hoses › Number
Issued 28 September 2005 Resolved
Provide proper fire hose and nozzle. 46 CFR 181.15-10.
Action required: 705 - Other - as specified
Resolved 29 September 2005
Fire Fighting › Fire Pumps › Arrangement
Issued 28 September 2005 Resolved
Demonstrate operation of fire pump and bilge system. 46 CFR 181.10.
Action required: 705 - Other - as specified
Resolved 29 September 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 28 September 2005 Resolved
Prove proper operation of lube oil gauge on main propulsion engine. 46 CFR 182.20-5.
Action required: 705 - Other - as specified
Due 28 October 2005
Resolved 14 November 2005
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 28 September 2005 Resolved
Remove combustible materials from bilge. 46 CFR 176.830.
Action required: 705 - Other - as specified
Resolved 29 September 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 September 2005 Resolved
Demonstrate operation of bilge high water level alarm. 46 CFR 182.530.
Action required: 705 - Other - as specified
Resolved 29 September 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 28 September 2005 Resolved
Provide means to secure marine sanitation device discharge. 46 CFR 176.818.
Action required: 705 - Other - as specified
Resolved 29 September 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 September 2005 Resolved
Demonstrate operation of navigation lights. 46 CFR 183.420.
Action required: 705 - Other - as specified
Resolved 29 September 2005
Engineering › Fuel Oil Service System › Vent Pipe
Issued 28 September 2005 Resolved
Provide 30 x 30 mesh screens for fuel tank vents. 46 CFR 182.20-35(d).
Action required: 705 - Other - as specified
Resolved 29 September 2005
Construction/Loadline › Hull › Bottom Plating
Issued 15 June 2005 Resolved
Make proper repairs to hull plating as noted on gauging report and as marked by inspector.
Action required: 705 - Other - as specified
Due 15 June 2005
Resolved 21 June 2005
Construction/Loadline › Hull › Bottom Plating
Issued 15 June 2005 Resolved
Renew side shell as marked on port and starboard side of forepeak.
Action required: 705 - Other - as specified
Resolved 27 July 2005
Construction/Loadline › Hull › Weld
Issued 15 June 2005 Resolved
Back-gouge and cap fillet weld along entire port and starboard bilge strakes.
Action required: 705 - Other - as specified
Resolved 27 July 2005
Engineering › Steering Gear System › Rudder
Issued 15 June 2005 Resolved
Renew and prove proper operation of rudder.
Action required: 705 - Other - as specified
Resolved 27 July 2005
Stability › Watertight Integrity › General
Issued 15 June 2005 Resolved
Provide gaskets for watertight hatches on main deck.
Action required: 705 - Other - as specified
Resolved 27 July 2005
Electrical › Electric Generation Source (service) › Generator
Issued 15 June 2005 Resolved
Provide plans for new main deck generator and its distribution panel.
Action required: 705 - Other - as specified
Resolved 27 July 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 15 June 2005 Resolved
Provide one additional adult lifejacket for a total of 154 adult and 16 child size. 46 CFR 180.71.
Action required: 705 - Other - as specified
Resolved 29 September 2005
Documentation › Certificates/Documents › FCC SSL
Issued 15 June 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 28 October 2005
Resolved 14 November 2005
Navigation
Issued 2 July 2001 Resolved
REMOVE PAINT OFF BOTH PORT AND STARBOARD RUNNING LIGHTS AS REQUIRED BY 46 CFR 183.420.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Lifesaving
Issued 2 July 2001 Resolved
PROVIDE PROPER SAFETY GLASS IN ALL WINDOWS ACCESSIBLE TO PASSENGERS AND CREW AS REQUIRED BY 46 CFR 177.1010.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Electrical
Issued 2 July 2001 Resolved
PROVIDE PROPER WIRING FOR ALL CABLES AND FEEDERS AS REQUIRED BY 46 CFR 183.330.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Lifesaving
Issued 2 July 2001 Resolved
PROVIDE FIRST AID AND CPR TRAINING FOR 50 % OF CREW AS REQUIRED BY NVIC 1- 91.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Lifesaving
Issued 2 July 2001 Resolved
PROVIDE PASSENGER COUNT AS REQUIRED BY 46 CFR 185.504.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Documentation
Issued 2 July 2001 Resolved
PROVIDE PROPER CHARTS AND PUBLICATIONS AS REQUIRED BY 46 CFR 184.420.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Documentation
Issued 6 April 1998 Resolved
PROVIDE DOCUMENTATION THAT THE CREW IS ENROLLED IN A RANDOM DRUG TESTING PROGRAM AS PER 46 CFR PART 16.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Documentation
Issued 6 April 1998 Resolved
PROVIDE A VALID FCC COMMERCIAL RADIO OPERATORS LICENSE. 47 CFR 80.155.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Navigation
Issued 29 April 1997 Resolved
PROVIDE AND INSTALL A ANCHOR LIGHT IAW 72 COLREGS (M16672.2) ANNEX I.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Lifesaving
Issued 29 April 1997 Resolved
PROVIDE AND POST A STATION BILL IAW 46 CFR 185.516.
Condition: Unknown
Due 29 May 1997
Resolved 28 May 1997
Documentation
Issued 29 April 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Engineering
Issued 29 April 1997 Resolved
RENEW ALL FRACTURED AND WASTED PADDLE WHEEL PLANKS AS ORIGINAL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN 29JUN97.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Construction/Loadline
Issued 29 April 1997 Resolved
PROVIDE A HAND BILGE PUMP CAPABLE OF REACHING THE BOTTOM OF ALL COMPARTMENTS IAW 46 CFR 182.320(B)(2).
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Lifesaving
Issued 29 April 1997 Resolved
PROVIDE AND POST A LIFEJACKET DONNING PLACARD IAW 46 CFR 185.516.
Condition: Unknown
Due 29 May 1997
Resolved 28 May 1997
Lifesaving
Issued 29 April 1997 Resolved
PROVIDE 3EA RED AND ORANGE DISTRESS SIGNALS WITH PROPERLY MARKED WATERTIGHTCONTAINER IAW 46 CFR 180.68 AND 185.614.
Condition: Unknown
Due 29 May 1997
Resolved 28 May 1997
Lifesaving
Issued 29 April 1997 Resolved
PRIVIDE RETRO REFLECTIVE TAPE ON RING BUOY IAW 46 CFR 185.604(B)(1) AND RENEW ALL LINE WITH DARK COLORED LINE IAW 46 CFR 180.70.
Condition: Unknown
Due 29 May 1997
Resolved 28 May 1997
Lifesaving
Issued 29 April 1997 Resolved
PROVIDE ADDITIONAL ITEMS AS PER 46 CFR 160.041 FOR FIRST AID KIT OR PROVIDEA COAST GUARD APPROVED FIRST AID KIT IAW 46 CFR 184.710.
Condition: Unknown
Due 29 May 1997
Resolved 28 May 1997
Engineering
Issued 29 April 1997 Resolved
PROVIDE A FUEL STOP VALVE ON THE ENGINE END OF THE FUEL LINE IAW 46 CFR 182.455(B)(4).
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Engineering
Issued 29 April 1997 Resolved
PROVE PROPER OPERATION OF THE MAIN ENGINE TACHOMETER AT THE PILOT HOUSE IAW46 CFR 182.410(B).
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Engineering
Issued 29 April 1997 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FUEL VALVE IAW 46 CFR 185.608.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Construction/Loadline
Issued 29 April 1997 Resolved
PROVIDE A LANYARD ON THE FORWARD W/T HATCH IAW 46 CFR 179.360(A)(2).
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Construction/Loadline
Issued 22 April 1996 Resolved
PROVIDE AND INSTALL LOCKING DEVICE ON VESSEL BILGE PUMP.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 22 April 1996 Resolved
CONDUCT BOAT DRILLS (FIRE AND MAN OVERBOARD)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 22 April 1996 Resolved
STENCIL VESSEL NAME ON CHILD PFD (THOSE MARKED JULIS DUFENO II) IF RETAINEDON BOARD.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Engineering
Issued 22 April 1996 Resolved
REPAIR HYDRAULIC LEAKING HOSE ON VESSEL PRIME MOVER.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 22 April 1996 Resolved
MARK FLARE CONTAINER.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Engineering
Issued 20 March 1995 Resolved
LABEL EMERGENCY FUEL SHUTOFF VALVES ON THE EXTERIOR OF ACCESS TO BE VISABLEAS PER 46CFR185.30-20.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Accommodation/Occupational Safety
Issued 20 March 1995 Resolved
INSTALL VENT PIPING FOR SEWAGE TANK WITH 30X30 MESH SCREEN AS REQUIRED IN 33CFR159.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Engineering
Issued 20 March 1995 Resolved
RENEW 30X30 MESH SCREEN ON FUEL TANK SPACE VENT.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Navigation
Issued 20 March 1995 Resolved
PROVIDE PROPER SIZE BELL IAW 72 COLREGS ANNEX III. (7.9" OR 200MM MINIMUM)
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Documentation
Issued 20 April 1994 Resolved
PROVIDE ON BOARD VALID FCC STATION LICENSE AND FCC MARINE OPERATORS PERMIT.
Condition: Unknown
Due 20 May 1994
Resolved 17 June 1994
Documentation
Issued 28 January 1994 Resolved
PROVIDE ON BOARD VALID FCC STATION LICENSE
Condition: Unknown
Due 28 January 1994
Resolved 28 January 1994
Lifesaving
Issued 30 January 1992 Resolved
STENCIL VESSEL'S NAME ON RING BUOY.
Condition: Unknown
Due 30 January 1992
Resolved 30 January 1992
Documentation
Issued 30 January 1992 Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 30 January 1992
Resolved 30 January 1992
Navigation
Issued 30 January 1992 Resolved
INSTALL AN ANCHOR LIGHT IN ACCORDANCE WITH RULE 30 OF THE INLAND NAVIGATIONRULES.
Condition: Unknown
Due 30 January 1992
Resolved 30 January 1992
Navigation
Issued 30 January 1992 Resolved
INSTALL PROPER LINING IN NEW BATTERY BOXES.
Condition: Unknown
Due 30 January 1992
Resolved 30 January 1992
Documentation
Issued 30 January 1992 Resolved
PROVIDE EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 30 January 1992
Resolved 30 January 1992
Lifesaving
Issued 30 January 1992 Resolved
PROVIDE SIX (6) HAND HELD RED DISTRESS FLARES.
Condition: Unknown
Due 30 January 1992
Resolved 30 January 1992
Construction/Loadline
Issued 18 March 1991 Resolved
INSTALL FLAME SCREENS ON FUEL TANK VENT AND SEWAGE TANK VENT.
Condition: Unknown
Due 18 March 1991
Resolved 18 March 1991
Engineering
Issued 18 March 1991 Resolved
REPLACE FUEL HOSE WITH ACCEPTABLE HOSE.
Condition: Unknown
Due 18 March 1991
Resolved 18 March 1991
Lifesaving
Issued 23 January 1990 Resolved
PASSENGERS ARE LIMITED TO A TOTAL OF 140 PERSONS, UNTIL 10 ADDITIONAL LIFE PRESERVERS ARE EXAMINED BY A COAST GUARD MARINE INSPECTOR AND PLACED ABOARDTHE VESSEL.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Electrical
Issued 23 January 1990 Resolved
PROVIDE ELECTICAL PLANS TO [name withheld], FL FOR REVIEW.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990

Casualty record · 1

8 December 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3113042
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.