Records from 1989 to 2016. Most recent: inspection, 8 September 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
8 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5995654
3 October 2007
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3065809
23 March 2007
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2892859
3 November 2005
Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2528239
8 February 2005
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2342040
25 August 2004
Re-Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2178700
23 January 2004
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1991341
13 January 2004
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1983419
2 October 2003
Simplified Stability Test · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1922912
21 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1622447
22 May 2001
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1445813
8 August 2000
Deficiency Check · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1430906
5 August 1999
Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1113262
8 June 1998
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1386274
25 June 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1113876
9 June 1997
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1458427
3 June 1996
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1077837
9 June 1995
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 876983
1 July 1994
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 963104
10 June 1994
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1017310
14 July 1993
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1155434
10 June 1992
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 943471
6 June 1991
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1241894
23 May 1990
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 911837
14 June 1989
Initial Certification · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1032319
17 January 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1202350
Construction/Loadline › Hull › Hull Plating
Issued 3 October 2007
Resolved
Provide MSD Port Canaveral with a written repair proposal for approval, to remove plastic inspection ports from fwd and aft pontoons and add foam (provide foam specs for approval). Once approved, remove inspection port covers, and add foam IAW approved written repair proposal, to the satisfaction of attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016
Resolved 8 September 2016
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 3 October 2007
Resolved
Install proper safety rails (39.5"), including aft of vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016
Resolved 8 September 2016
Stability › Incline Test › General
Issued 3 October 2007
Resolved
Conduct a simplified stability test in the presence of CG marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016
Resolved 8 September 2016
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 23 March 2007
Resolved
Provide one additional adult size PFD. Vessel is limited to not more than 21 total persons until completed.
Action required: 705 - Other - as specified
Due 30 March 2007
Resolved 24 March 2007
Resolution: Completed. Received fax copy of invoice indicating additional PFD has been purchased.
Lifesaving › Hand Flares › Quantity
Issued 23 March 2007
Resolved
Provide 3 additional hand held flares.
Action required: 705 - Other - as specified
Due 30 March 2007
Resolved 24 March 2007
Resolution: Completed. Received fax copy of invoice indicating flares have been purchased.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 November 2005
Resolved
REPLACE MISSING ITEMS IN FIRST AID KIT
Due 10 November 2005
Resolved 8 November 2005
Personnel › Certificates/Documents/Licenses › License, Master
Issued 3 November 2005
Resolved
PROVIDED CG LICENSE FOR MASTER
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 3 November 2005
Resolved
POST EMERGENCY INSTRUCTION
Due 10 November 2005
Resolved 8 November 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 November 2005
Resolved
POST COI
Due 10 November 2005
Resolved 8 November 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 3 November 2005
Resolved
MOUNT PORTABLE FIRE EXTINGUISHER
Due 10 November 2005
Resolved 8 November 2005
Documentation › Certificates/Documents › Stability Letter
Issued 3 November 2005
Resolved
POST STABILITY LETTER
Due 10 November 2005
Resolved 8 November 2005
Electrical › Electric Supply System (service) › Cable
Issued 25 August 2004
Resolved
Issued CG-835 to repair electrical connection under console.
Condition: Placed in Improper Service
Due 10 September 2004
Resolved 10 September 2004
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 August 2004
Resolved
Issued CG-835 to provide approved fire extinguisher brackets for both fire extinguishers.
Condition: Unknown
Due 10 September 2004
Resolved 10 September 2004
Resolution: Corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 25 August 2004
Resolved
Issued CG-835 to replace retro-flective tape on lifebouy.
Condition: Improper/Lack of Maintenance
Due 10 September 2004
Resolved 10 September 2004
Resolution: Corrected.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 August 2004
Resolved
Issued CG-835 to test all pontoon hulls prior to carring passengers & to the satisfaction of attending CG marine inspector.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Resolution: Corrected.
Construction/Loadline › Structures › Superstructure
Issued 25 August 2004
Resolved
Issued CG-835 to replace all missing bolts in deck framing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Resolution: Corrected.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 October 2003
Resolved
Issued CG-835 to provide original copy of the COI. The owner did not have a copy of the original. The previous owner did not provide it at the time of the sale.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: After owner discovered he was not provided an original copy from the previous owner it was decided to conduct a new COI inspection.
Personnel › Manning/Qualifications
Issued 2 October 2003
Resolved
Issued CG-835 to provide proof of CPR/first aid training.
LEGACY COMPONENT DESC: CPR Certified Personnel
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Traing was obtained.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 2 October 2003
Resolved
Issued CG-835 to provide a current training log.
Condition: Unknown
Due 2 November 2003
Resolved 9 October 2003
Resolution: Training log provided.
Lifesaving › Hand Flares › Quantity
Issued 2 October 2003
Resolved
Issued CG-835 to provide three orange flares.
Condition: Unknown
Due 2 November 2003
Resolved 9 November 2003
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 2 October 2003
Resolved
Issued CG-835 to post lifejacket donning procedures.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 2 October 2003
Resolved
Issued CG-835 to mount B-II fire extinguishers forward.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Corrected.
Fire Fighting › Fire Pumps
Issued 2 October 2003
Resolved
Issued CG-835 to provide one 2.5 gallon fire bucket
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Corrected.
Pollution Prevention/Response
Issued 2 October 2003
Resolved
Issued CG-835 to post an oil pollution placard.
Condition: Unknown
Due 2 November 2003
Resolved 9 October 2003
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 October 2003
Resolved
Issued CG-835 to install cable next to operating station.
Condition: Unknown
Due 2 November 2003
Resolved 9 October 2003
Resolution: Corrected.
Construction/Loadline › Vessel Safety Management › Deck Rail
Issued 2 October 2003
Resolved
Issued CG-835 to secure seating to the deck.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 October 2003
Resolved
Issued CG-835 to install cables aft of toilet space to 39 and one half inches and no more than 12 inches apart.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 2 October 2003
Resolved
Issued CG-835 to separate and label child lifejacket storage.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Corrected.
Engineering › Fuel Oil Service System › Valve
Issued 2 October 2003
Resolved
Issued CG-835 to label fuel shut-off valve.
Condition: Unknown
Due 2 November 2003
Resolved 9 October 2003
Resolution: Corrected.
Engineering › Bilge Water Management System › Pump
Issued 2 October 2003
Resolved
Issued CG-835 to provide a 5 gpm bilge pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2003
Resolution: Corrected.
Construction/Loadline › Hull › Hull Plating
Issued 2 October 2003
Resolved
Issued CG-835 to install inspection port in center potoon at next drydock.
Condition: Unknown
Due 31 August 2004
Resolved 25 August 2004
Resolution: Corrected.
Personnel › Manning/Qualifications
Issued 2 October 2003
Resolved
Issued CG-835 to provide a deckhand by 03Nov03. LEGACY COMPONENT DESC: Minimum Safe Manning
Condition: Unknown
Due 3 November 2003
Resolved 23 January 2004
Resolution: CLEARED.
Operations/Management › Drills/Instruction
Issued 21 May 2002
Resolved
Provide and maintain a training log for drills.
Due 3 June 2002
Resolved 4 June 2002
Resolution: As per phone call this date.
Documentation › Manuals/Policy Documentation
Issued 21 May 2002
Resolved
Provide first aid training and a valid first aid card for 50 % of the crew.
Due 10 June 2002
Resolved 11 June 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 21 May 2002
Resolved
Properly mount fire extinguishers. LEGACY COMPONENT DESC: Mounting Bracket
Due 10 June 2002
Resolved 4 June 2002
Resolution: As per phone call this date.
Engineering › Gasoline Engine (propulsion)
Issued 21 May 2002
Resolved
Replace fuel line to outboard motor with a SAE J-1942.
Due 10 June 2002
Resolved 11 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 May 2002
Resolved
Provide a Coast Guard first aid kit or the equivalent.
Due 17 June 2002
Resolved 19 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 May 2002
Resolved
Properly mount all seats to the deck.
Due 3 June 2002
Resolved 4 June 2002
Resolution: As per phone call this date.
Lifesaving
Issued 8 August 2000
Resolved
RENEW LABELS ON PFD'S WITH VESSEL NAME.
Condition: Unknown
Due 14 August 2000
Resolved 22 August 2000
Lifesaving
Issued 8 August 2000
Resolved
PROVIDE PFD DONNING PLACARD.
Condition: Unknown
Due 14 August 2000
Resolved 22 August 2000
Fire Fighting
Issued 8 August 2000
Resolved
PROVIDE CURRENT SERVICE REPORT FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 14 August 2000
Resolved 22 August 2000
Engineering
Issued 8 August 2000
Resolved
INCREASE VENTILATION TO FUEL TANK BOX TO EQUAL OR EXCEED 180 SQUARE INCHES.
Condition: Unknown
Due 14 August 2000
Resolved 22 August 2000
Engineering
Issued 8 August 2000
Resolved
DOUBLE CLAMP ALL FUEL LINES WHERE SINGLE CLAMPS ARE INSTALLED.
Condition: Unknown
Due 14 August 2000
Resolved 22 August 2000
Engineering
Issued 9 June 1997
Resolved
REPLACE UNSERVICABLE FLAME ARRESTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 9 June 1997
Resolved 19 June 1997
Engineering
Issued 9 June 1997
Resolved
INSTALL VENTILATION DUCTS IN ENGINE COMPARTMENT AND REPLACE POWER BLOWER ASPER 46 CFR 182.15-45
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Documentation
Issued 9 June 1997
Resolved
COMPLY WITH RANDOM DRUG TESTING REQUIREMENTS AS PER 46 CFR 16
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Documentation
Issued 14 July 1993
Resolved
PROVIDE PROOF OF IMPLIMENTATION OF RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 24 July 1993
Resolved 20 August 1993
Lifesaving
Issued 6 June 1991
Resolved
PROVIDE 3 ADULT LIFE PRESERVERS (TYPE I).
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991