STAR PRIDE

STAR PRIDE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 138 inspections since 1988, most recently in September 2025, along with 102 deficiencies and 2 operational controls.

Records from 1988 to 2025. Most recent: inspection, 25 September 2025.

Built
1987
Last inspected
25 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8707343 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
324980
Flag
NORWAY
—
Maury page id
psix-324980

Inspections, by type

…with no type recorded51
Years with a record 30 calendar years (1988–2025)
The 138 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it12969 - Convention (Subpart B), Gross Ton
3023 - Convention (Subpart B), Net Ton
7150 - Displacement, Ton
780 - Dead Weight, Ton
12969 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JET TRADER Tank Ship · MISLE 54437 · 28 October 2002 · activity 1699089BOBBY JR Freight Barge · MISLE 50145 · 18 October 1993 · activity 448959ELIZABETH LYKES * Freight Ship · MISLE 45050 · 11 April 1992 · activity 52427

Inspection history · 138

25 September 2025 COC-CVE Annual · Deficiency Check · PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8240717
9 December 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8044940
29 September 2024 COC-CVE Annual · PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8006249
2 October 2023 PSC B · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7798771
29 September 2022 COC-CVE Initial · PSC B · ISPS Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7554325
23 September 2021 COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 7318590
9 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937612
7 March 2020 COC-CVE Quarterly · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6915924
16 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6835553
11 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6832707
9 September 2019 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6792466
13 May 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6682832
9 March 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6651272
2 March 2019 COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6632693
7 December 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6592460
7 December 2018 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6593457
16 November 2018 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6582255
10 September 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6539441
8 September 2018 NPV Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6535578
7 September 2018 Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6558478
6 September 2018 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6518430
5 April 2018 NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6387073
24 November 2017 ISPS II Exam · COC-CVE Initial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6308701
16 December 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3380742
11 November 2008 ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3359078
14 March 2008 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3164317
29 September 2007 Ballast Water Examination · MARPOL Annex V Examination · ILO-147 Exam · COC-CVE Annual · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3068811
11 October 2006 ISPS II Exam · COC-CVE Initial
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2795272
15 March 2006 ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2603190
2 November 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2527034
24 October 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2521419
2 October 2005 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2505694
15 September 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC · Ballast Water Examination · COC-CVE Annual · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2492840
4 April 2005 NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2325849
15 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2310737
11 March 2005 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2308020
19 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2262448
3 November 2004 Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2233733
14 October 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2220917
16 September 2004 COC-CVE Annual
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2197137
9 September 2004 ISPS II Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2191159
2 April 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2036326
15 March 2004 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2023846
4 November 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1941944
3 November 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1941028
3 November 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1941287
21 October 2003 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1932744
8 October 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1924098
6 October 2003 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1928103
24 September 2003 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1912150
17 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1758433
6 November 2002 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1701674
4 November 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1700629
29 October 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1697941
28 October 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1699089
30 September 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1681954
25 September 2002 Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1680133
25 September 2002 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1682066
19 March 2002 Quarterly Examination · Ballast Water Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1494614
11 November 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 485558
13 October 2001 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1074920
23 September 2001 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1073607
20 September 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 293866
24 March 2001 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1370057
19 September 2000 Control Verification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1445680
4 April 2000 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 825305
15 January 2000 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 814521
27 December 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 521075
23 December 1999 MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1365492
4 October 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 432758
4 October 1999 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1429259
19 September 1999 Control Verification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1348621
16 March 1999 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360779
23 December 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 807555
22 December 1998 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421591
2 November 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 438320
2 November 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 505691
19 September 1998 Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1464131
13 March 1998 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 413508
13 March 1998 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1372172
11 December 1997 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1398819
29 September 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 779619
15 September 1997 MARPOL Annex I Examination · Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1112390
18 March 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 401685
18 March 1997 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1439851
20 December 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 397774
20 December 1996 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1093669
10 December 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 398164
10 December 1996 Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1091757
6 September 1996 Quarterly Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1466436
21 August 1996 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 757713
20 August 1996 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 203812
8 August 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1089876
7 June 1996 Control Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1404227
20 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 883237
21 March 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 205076
21 March 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 454226
21 March 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 755092
18 February 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 375590
18 February 1995 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 847623
22 November 1994 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1457214
26 September 1994 Quarterly Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1173918
2 June 1994 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1171206
7 March 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 854781
17 November 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1164970
17 November 1993 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1358226
18 October 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 448959
15 October 1993 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1432736
14 September 1993 MARPOL Annex V Examination · Control Verification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 841351
14 September 1993 Control Verification · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 850051
10 March 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 357025
10 March 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1147871
28 November 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 516280
28 November 1992 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1141838
18 September 1992 Control Verification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1247039
11 April 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 52427
7 March 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 949927
7 December 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 347641
7 December 1991 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 950527
18 September 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 942033
10 July 1991 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1245450
26 June 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 942244
17 May 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 343761
13 March 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 445569
13 March 1991 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 905803
19 December 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 908085
17 December 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1240760
26 October 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 931505
18 October 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1241200
15 October 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1228128
1 October 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1236040
3 March 1990 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1229261
2 March 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 335692
11 November 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 333727
11 November 1989 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1223482
21 March 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 329270
21 March 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1272978
20 December 1988 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 891804

Deficiency record · 102

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 September 2025 Resolved
The minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. PSCO observed deck penetration in engine room overhead between frame 50 and 55. Cite: 74 SOLAS 81 Amend II-2/26.1 Code: 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2025
Resolved 16 October 2025
Resolution: Provided Class Report attesting to the the fire boundary being restore, report uploaded into documents.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 September 2025 Resolved
The minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. PSCO observed fire door 649 3-way solenoid valve for air compressor was not functioning as designed, rendering the door incapable of closing to maintain the required fire boundary. Cite: 74 SOLAS 81 Amend II-2/26.1 Code: 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2025
Resolved 16 October 2025
Resolution: Provided Class Report attesting to the the solenoid being replaced and fire door 649 was restored to normal operation ability, report uploaded into documents.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 September 2025 Resolved
The minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. PSCO observed cabin number 2014, fire boundary into crew cabin area had an excessive gap located between the door and threshold, compromising the fire boundary. Cite: 74 SOLAS 81 Amend II-2/26.1 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 26 September 2025
Resolution: A transom was installed to remove the gap.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 September 2025 Resolved
Any required automatic sprinkler, fire detection and fire alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. PSCO observed carpet stowed above the maximum loading height in the carpet locker room, impeding proper operation of fixed fire suppression. Cite: 74 SOLAS 97 II-2/12.1.1 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 25 September 2025
Resolution: Carpet was removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2025 Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all passenger and crew spaces and from spaces in which the crew is normally employed, other than machinery spaces. PSCO observed a moveable cart from the galley being stowed at the landing of a stairway used for means of escape. Cart obstructed the escape path. Cite: 74 SOLAS 81 Amend II-2/28.1 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 25 September 2025
Resolution: Cart was moved back to its storage location in the galley.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 25 September 2025 Resolved
The master or person in charge of a ship shall ensure that one or more placards are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. PSCO observed the garbage room was missing the MARPOL garbage placard. Cite: 33 CFR 151.59 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 25 September 2025
Resolution: Garbage placard was added to the garbage room.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 September 2025 Resolved
The minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. PSCO observed fire door 622 had a missing gasket, compromising the fire boundary. Cite: 74 SOLAS 81 Amend II-2/26.1 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 25 September 2025
Resolution: Gasket was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 September 2025 Resolved
Exhaust ducts from galley ranges in which grease or fat is likely to accumulate shall be fitted with a fire damper located in the lower end of the duct. PSCO observed fire damper in the Veranda galley was not operational. Cite: 74 SOLAS 01 II-2/41-2.4.3 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 25 September 2025
Resolution: Fire damper was fixed and operational test was conducted to confirm proper function.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2025 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of force in the direction of escape flow. PSCO observed thumb latches located on doors for the motion flow room as well as the gym. Doors used for means of escape did not have a door-latching mechanism that releases the latch upon application of force in the direction of escape flow. Vessel underwent a major extension project in 2021, therefore, areas located in MVZ 5 must adhere to most recent SOLAS requirements. Cite: 74 SOLAS 20 II-2/13.3.2.6.2 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 25 September 2025
Resolution: The two doors with thumb-latches were replaced with door-latching mechanisms that were able to release the latch upon application of force in the direction of escape flow.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 September 2025 Resolved
The minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. PSCO observed the following: FSD 148 has a removable transom that should be in place at all times to maintain the fire boundary, the removable transom was not in place while in port. Cite: 74 SOLAS 81 Amend II-2/26.1 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 25 September 2025
Resolution: The removable transom was put back in place.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 September 2025 Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed fire door 340 failed to latch. Cite: 74 SOLAS 81 Amend II-2/30.2 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 25 September 2025
Resolution: Adjustments were made to the door. Door was able to latch.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 September 2025 Resolved
The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to persons. PSCO observed the following: fire door 180, fire door 580, and fire screen door 640 closed in 5 seconds. Cite: 74 SOLAS 81 Amend II-2/30.4 Code: 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2025
Resolved 25 September 2025
Resolution: Adjustments were made to the timing of the door closings and now w/in time closure tolerance.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 29 September 2024 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43. The embarkation lighting forward of lifeboat #2 was not illuminating. 74SOLAS 97 III/11.4 10c
Action required: 10 - Deficiency Rectified
Due 29 September 2024
Resolved 29 September 2024
Resolution: The embarkation lighting forward of lifeboat #2 was repaired and in functioning order.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 September 2024 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed a light in the caudro 44 galley was leaking water from within. 74 SOLAS 04 II-1/40.1.3 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2024
Resolved 9 December 2024
Resolution: Received report attesting to satisfactory repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 September 2024 Resolved
The loadline ring, lines and letters shall be painted white or yellow on a dark background or in black on a light background. They shall also be permanently marked. The deckline was painted white on a white background and was not black on a light background. Load Line Convention 8 10c
Action required: 10 - Deficiency Rectified
Due 29 September 2024
Resolved 29 September 2024
Resolution: The load line was painted dark blue on a white background.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2024 Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights, not less than two of these shall also be provided with lifebuoy self-activating smoke signals and be capable of quick release from the navigation bridge. PSCO observed the self-igniting light on deck 8 starboard side midship was inoperable. 74 SOLAS 97 III/7.1.3 10c
Action required: 10 - Deficiency Rectified
Due 29 September 2024
Resolved 29 September 2024
Resolution: The inoperable ring lifebuoy light was replaced with a functional light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2024 Resolved
Each lifebuoy shall be marked in block capitals of the Roman alphabet with the name and port of registry of the ship. PSCO observed the ring lifebuoy located on deck 5 aft starboard side did not have the name or port of the ship registry marked. 74 SOLAS 97 III/7.1.4 10c
Action required: 10 - Deficiency Rectified
Due 29 September 2024
Resolved 29 September 2024
Resolution: The ring lifebuoy was marked in block capitals of the name and port of registry of the ship.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 September 2024 Resolved
The minimum for integrity of all bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. FD(s) 622,640,A306 are required to maintain an "A" rating. PSCO observed the afor listed doors were not latching and maintaining the required boundary. 74 SOLAS 81 Amend II-2/26.1 10c
Action required: 10 - Deficiency Rectified
Due 29 September 2024
Resolved 29 September 2024
Resolution: The fire doors were repaired and found to latch as required.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 September 2024 Resolved
The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to persons. PSCO observed FD(s) 585, 180 and A602 closing too fast. 74 SOLAS 81 Amend II-2/30.4 10c
Action required: 10 - Deficiency Rectified
Due 29 September 2024
Resolved 29 September 2024
Resolution: The doors were repaired and controlled so as to prevent undue danger to persons.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 October 2023 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO observed FSD402 and the fire safety door on deck 5 near the pantry not able to self-close. Deficiency Code: 07105 Action Code: 10c 74 SOLAS 97 II-2/47.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 October 2023
Resolved 2 October 2023
Resolution: Fire doors re-fitted and are now fully gastight and self-closing.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed the collar of the emergency generator space exhuast to be wasted. Deficiency Code: 02199 Action Code: 10c 74 SOLAS 14 1/11.a
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 October 2023
Resolved 2 October 2023
Resolution: E-gen exhaust collar replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 March 2020 Resolved
The construction of all doors and door frames in "A"Class divisions shall provide resistance to fire as wells as flame. The PSCO found three (03) "A" class doors taht had the lock sets removed leaving an opeining that would pass flame and smoke. SOLAS (1981) II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 March 2020
Resolved 7 March 2020
Resolution: Blank metal plates were installed on both sides of the doors
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 March 2020 Resolved
Firefighting systems and appliances shall be kept in good working order and ready for immediate use. The PSCO found the key located in the break glass box for the emergency generator fixed firefighting release box was wasted and would not have operated the latching mechanism.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 March 2020
Resolved 7 March 2020
Resolution: New key was placed inside the break glass box.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 7 March 2020 Resolved
Except where otherwise stated the normal equipment of every lifeboat shall consist of food rations totaling not less than 10,000 KJ for each person the lifeboat is permitted to accommodate. The PSCO found a total of 14 food rations with the airtight seal being compromised, allowing are to enter inside found rations. SOLAS (1983) III/41.8
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 March 2020
Resolved 7 March 2020
Resolution: All 14 rations replace from ships stores.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 September 2019 Resolved
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. various quick closing valves in the engine room are not operational. 74 SOLAS (97 Cons) Ch. II-2/Reg. 15.2.5 10c
Action required: 10 - Deficiency Rectified
Resolved 9 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 September 2019 Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to the bulkhead. Escape door and door frame from engine room to deck 3 galley allows air passage. 74 SOLAS (81 Amend) CH. II-2/Reg 30.2 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2019
Resolved 3 October 2019
Resolution: Door fully closes and does not allow air passage.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 September 2019 Resolved
Fire doors in main vertical zone bulkheads shall be of the self-closing type and be controlled so to prevent undue danger to persons. Fire Doors 236A, 640, 627 do not fully close. 74 SOLAS (81 Amend) Ch. II-2/Reg 30.4 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2019
Resolved 3 October 2019
Resolution: Doors fully closed to satisfaction of RO.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 9 September 2019 Resolved
Oil filtering equipment shall be such as will ensure that any oily mixture discharged into the sea has an oil content not exceeding 15 ppm. Vessel was unable to demonstrate operational use of the OWS. MARPOL I/14 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 11 October 2019
Resolution: Vessel installed and commissioned OWS 17Sep2019. BV attended the vessel and varified the vessel demonstrated operation of the OWS
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 9 September 2019 Resolved
Non-fixed furniture shall be removed from Aft Stairwell. 74 SOLAS (81 Amend) Ch. II-2/Reg 34.6 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 3 October 2019
Resolution: Furniture was removed from space.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 September 2019 Resolved
Each lifeboat shall be capable of launching and recovering the lifeboat. Aft sheave not rotating for lifeboat #1. 74 SOLAS (97 Cons) Ch. III/Reg 15.2 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 3 October 2019
Resolution: All sheaves are rotating.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 9 September 2019 Resolved
No fuel oil tank shall be situated where spillage or leakage can constitute a hazard by falling on heated surfaces precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter, or heater from coming into contact with heated surfaces. Lagging was missing from various parts in the oil purifier room. 74 SOLAS (97 Cons) Ch. II-2/Reg 15.4 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 3 October 2019
Resolution: Lagging was added in purifier room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 2 March 2019 Resolved
The normal equipment of every lifeboat shall have sufficient tools for manual adjustments to the engine and its accessories. PSCO found missing tools in all 4 lifeboats. LSA (17) IV/4.4.8.27, 16c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2019
Resolved 10 May 2019
Resolution: The vessel provided the missing tools to all four lifeboats.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 March 2019 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: the structural fire protection, including fire resisting divisions and penetrations at openings and penetrations in the divisions. A fire door frame penetration in an A-class boundary was found. 74 SOLAS 2014 II-2/2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 2 March 2019
Resolution: The crew affected a temporary repair to seal the penetration and proposed a satisfactory permanent repair to be made when the ship was not bunkering and out of port to weld.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 March 2019 Resolved
Additional aids for escape shall be provided as necessary to ensure accesibility, clear marking, and adequate design for emergency situations. A push button to open the door to the auxiliary machinery space was found to have no clear markings of its function to open the door and grant access.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2019
Resolution: Photo luminescent strips were installed around the button to make it clear how to access the door in a black out/reduced visibility emergency situation.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 March 2019 Resolved
Means of escape, including stairways and exits, shall be marked by lighting or photo luminescent strip indicators above the deck at all points of the escape route including angles and intersections. PSCO found missing segments of photo luminescent strip at the bar, aft, deck 7. 74 SOLAS 1997 II-2/28.1.10, 10c
Action required: 10 - Deficiency Rectified
Resolved 2 March 2019
Resolution: New photo luminescent strips were installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2019 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO found that FM-200 fixed-fire suppression system hose in emergency diesel generator space was in poor condition with fish hooks and a kink.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2019
Resolved 10 May 2019
Resolution: The crew replaced the fixed fire suppression system hose with a new one.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 March 2019 Resolved
All doors shall be capable of remote and automatic release from a position at both sides of the door. Fire doors # 356 and machinery space changing room door found not to be closing. 74 SOLAS 1997 II-2/30.4.3, 10c
Action required: 10 - Deficiency Rectified
Resolved 2 March 2019
Resolution: Both doors were adjusted to self-close.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2019 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The following spaces were found to be used as storage containing combustible materials: 1. spa storage: flammable liquids stored in a storage locker that does not have fire detection system, suppression systems, or insulation. 2. Combustibles stored underneath stairways in Deck 2, MVZ1.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2019
Resolution: The crew removed combustible storage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 September 2018 Resolved
Found #3 cylindar on #2 MDE failed, fractured block. Engine is non functioning under class BV survey due by 8 DEC 2018.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 December 2018
Resolved 10 May 2019
Resolution: Received attestation from the vessel’s Class for the repairs conducted on the #2 MDE.
Engineering › Steering Gear System › Rudder
Issued 11 November 2008 Resolved
Provide class report attesting to the proper operation of the steering gear. USCG inspectors were unable to test steering gear due to divers in the water conducting maintenance on the rudder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2008
Fire Fighting › Fire Pumps › Arrangement
Issued 11 November 2008 Resolved
Provide class report attesting to proper repair of leaks on pipe of fire pump # 2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 11 November 2008 Resolved
Provide class report attesting to proper repair of hydraulic leak forward of watertight door # 2.
Action required: 705 - Other - as specified
Due 22 November 2008
Resolved 16 December 2008
Resolution: Received class survey report from DNV confirming the repairs to the hydraulic leak.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump Power Supply
Issued 15 March 2006 Resolved
Fixed Flexi fog nitrogen bottle selonoid switch not operable.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2006
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 15 September 2005 Resolved
Vessel had no davit raft available for testing as per MOC policy LTR 4-98 by 15OCT05. Launching and recovery of lifeboats on the port side was not conducted due to bunker barge moored alongside. Vessel is required to demonstrate launching of davit liferaft and launching/recovery of lifeboats in presence of USCG Inspector by 15 OCT 05.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 2 October 2005
Resolution: Witnessed satisfactory operational test of port side lifeboats and davit launched liferaft.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 March 2005 Resolved
Remove/ Replace dead end wiring in Club pantry, deck 6.
Due 15 March 2005
Resolved 12 March 2005
Resolution: Def corrected
Operations/Management › Drills/Instruction › Fire
Issued 11 March 2005 Resolved
Replace keys to fire stations 1 and 2.
Due 15 March 2005
Resolved 12 March 2005
Resolution: Def corrected
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 March 2005 Resolved
Repair firescreen door 651 (Wine Store).
Due 15 March 2005
Resolved 15 September 2005
Resolution: Checked above and found satisfactory
Fire Fighting › Fire Hoses › Connections
Issued 11 March 2005 Resolved
Replace spanner wrench in fire locker. FS51.
Due 15 March 2005
Resolved 15 September 2005
Resolution: Checked above and found satisfactory
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 March 2005 Resolved
Make operational sliding fire screen door closing alarm #354 on deck 6.
Due 15 March 2005
Resolved 15 September 2005
Resolution: Checked above and found satisfactory
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 19 December 2004 Resolved
Piping below, around and to #1 boiler is saturated with fuel. Renew and replace all piping insulation around boiler.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2004
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 19 December 2004 Resolved
Areas around boilers are saturated with fuel oil. Repair all leaking pipe fittings and clean are area.
Action required: 705 - Other - as specified
Resolved 19 December 2004
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 19 December 2004 Resolved
Prove proper operation of #1 boiler in regards to nozzle leakage and supply line solenoid valve opeation to determine source of leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2004
Operations/Management › Drills/Instruction › Fire
Issued 16 September 2004 Resolved
Upper fire boundaries during fire drill missing, Discussed outcome of drill with ship's officers at conclusion. See narrative this activity for details.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 16 September 2004
Operations/Management › Pollution › Control of Garbage
Issued 16 September 2004 Resolved
Found excessive amounts of liquid chlorine and hydraulic fluid stowed on deck in the ship's marina, a space not classified for stowage of this material.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 16 September 2004
Resolution: Crew restowed this correctly.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 September 2004 Resolved
Numerous main vertical zone fire screen doors found inoperative. See narrative this activity for details.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 16 September 2004
Resolution: Ships crew reapired all except one which now has condition of class imposed by DNV.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 16 September 2004 Resolved
Linen stores found improperly stowed with linens piled up to ceiling that blocked all fixed sprinkler system nozzles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 16 September 2004
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 16 September 2004 Resolved
Walk-in freezers C5 and C6 found stowed improperly with material piled up to ceiling that blocked all fixed sprinkler system nozzles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 16 September 2004
Fire Fighting › Structural - A Class Divisions › Pantries
Issued 16 September 2004 Resolved
Found club bar pantry lift shaft being used for storage of combustible materials and the A-60 door broken and inoperative. DNV addressed this space as still a lift shaft and NOT a store room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 16 September 2004
Resolution: This space was cleared out and the door repaired.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 16 September 2004 Resolved
Deck 4 zone 3 main sprinkler system pressure alarm found inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 16 September 2004
Resolution: DNV certified this was repaired.
Fire Fighting › Emergency Fire Pumps
Issued 24 September 2003 Resolved
Fuel Oil settling tank top adjacent to emergency fire pump was found with fuel oil all over the tank top resulting from a fewl leak from and unknown source. DNV shall attend the vessel and provide a written class report to USCG on Sept 30 that adresses this fuel lead and vessel's future intentions LEGACY COMPONENT DESC: settling tank top
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 8 October 2003
Resolution: Cleared by MSO Boston on 10/6/03 as noted on COC #03ACTNY093 dated 09/24/03
Lifesaving › Lifeboat Equipment › Food Ration
Issued 25 September 2002 Resolved
Replace 17 food rations prior to departure from New York. (NLT 30SEP02) in accordance with solas III/41.8.12.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 27 September 2002
Resolution: Provided 17 food rations provided faxed copy of receipt to MSO Boston.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 25 September 2002 Resolved
Provide class atestation pertaining to correct number and location of sprinkler heads (low and high velocity) NLT 23OCT02 in accordance with solas II-2/12-10 LEGACY COMPONENT DESC: Nozzles
Due 23 October 2002
Resolved 28 October 2002
Resolution: SATISFACTORY CLASS REPORT RECIEVED ATESTING TO THE CORRECT LOCATION AND NUMBER OF SPRINKLER HEADS.
Lifesaving › Lifejacket/PFD (Type II)
Issued 19 March 2002 Resolved
Provide labels on all lifejacket lockers to indicate number of adult and child lifejackets in each IAW SOLAS III/20.10. LEGACY COMPONENT DESC: Storage
Condition: Unknown
Due 20 September 2002
Resolved 25 September 2002
Resolution: Checked all lifejackets for proper labels. All SAT.
Navigation
Issued 11 December 1997 Resolved
Conduct and log all pre-arrival and pre-departure tests as required by Title 33 Code of Federal Regulations, Part 164.25(a)(1)(vii)(3) & (4).
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Fire Fighting
Issued 11 December 1997 Resolved
Prior to 15 March 1998, provide access hatch covers in way of the galley ducts in accordance with SOLAS 1974 (amended), Chapter II-2, Regulation 41-2.4.3.
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Fire Fighting
Issued 11 December 1997 Resolved
Prior to 15 March 1998, complete the installation of A-60 insulation in theoverhead of main entrance as per USCG Marine Safety Center letter of 11 September 1997.
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Navigation
Issued 15 September 1997 Resolved
COAST PILOT OUTDATED AND MISSING CORRECTIONS
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 15 September 1997 Resolved
UNABLE TO LAUNCH LIFEBOATS DUE TO OBSTRUCTING BARGES ALONGSIDE. LIFEBOATS ON SIDE OPPOSITE PIER ARE TO BE LAUNCHED AND MOTORED. REMAINDER OF ABANDON SHIP DRILL CONDUCTED SUCCESSFULLY.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Navigation
Issued 15 September 1997 Resolved
LIGHT LIST MISSING CORRECTIONS
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Construction/Loadline
Issued 6 September 1996 Resolved
OWS overboard discharge line holed. Repair prior to next US portcall.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Documentation
Issued 6 September 1996 Resolved
Oil pollution placard missing at engine room. Replace prior to next US portcall.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Electrical
Issued 7 June 1996 Resolved
PROVE OPERATION OF THE AC/DC CONVERTER FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Navigation
Issued 7 June 1996 Resolved
REPAIR OR REPLACE AND PROVE PROPER OPERATION OF THE CHANGEOVER AND POWER SENSING CONTROLLERS ON STEERING PUMPS NO 3 AND 4.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Fire Fighting
Issued 7 June 1996 Resolved
REPAIR OR REPLACE AND PROVE PROPER OPERATION OF FIRE SCREEN DOORS 640 AND 650. A CREW MEMBER MUST BE STATIONED AT BOTHY DOORS DURING DRILLS AND EMERGENCIES.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Fire Fighting
Issued 7 March 1994 Resolved
Replace missing light covers in photo shop, laundry, and throughout ship.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Fire Fighting
Issued 7 March 1994 Resolved
remove pooled waste oil from bilges under machinery in purifier room, engine room, and air conditioner room.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Fire Fighting
Issued 17 November 1993 Resolved
UPDATE THE FIRE CONTROL PLAN TO INDICATE LOCATION OF NEWLY INSTALLED STRUCTURAL FIRE PROTECTION BOUNDARIES AT CARPET STORE ROOM ON DECK 2 AT FIRE STATION 74.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Fire Fighting
Issued 10 March 1993 Resolved
ADJUST FIRE SCREEN DOORS 162 AND 176 TO CLOSE COMPLETELY.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Fire Fighting
Issued 10 March 1993 Resolved
REMOVE ALL COMBUSTIBLES FROM AIR CONDITIONING SPACES INCLUDING 669.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Fire Fighting
Issued 10 March 1993 Resolved
REMOVE HOOK FROM FIRE SCREEN DOOR 572.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Fire Fighting
Issued 10 March 1993 Resolved
FLAG ADMINISTRATION TO RESOLVE DISCREPENCY BETWEEN INSTALLED HALON SYS IN GALLEY AND II-2/REG5.3.1.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Accommodation/Occupational Safety
Issued 10 March 1993 Resolved
REMOVE COMBUSTIBLES FROM LOCKER IN FORWARD STAIRWAY ON DECK 5. LCK REQUIRESSMOKE/FIRE DETECTION. SEE INSPECTION NOTE MIAMS 13MAR91.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Fire Fighting
Issued 10 March 1993 Resolved
PROVIDE PROPER STRUCTURAL FIRE PROTECTION BOUNDRIES FOR THE CARPET STROE ROOM ON DECK 2 AT FIRE STATION 74, AS REQUIRED BY II-2/REG 26.2.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Fire Fighting
Issued 10 March 1993 Resolved
UPDATE THE FIRE CONTROL PLAN TO INDICATE ALL REMOTE STRAT LOCATIONS FOR THEFIRE PUMPS (NOT SHOWN FOR THE SAFETY CONTROL ROOM)
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Fire Fighting
Issued 18 September 1992 Resolved
PROVIDE STUFFING TUBE IN WAY OF WATERTIGHT BULKHEAD PENETRATION IN AFTER STEERING GEAR ROOM WHERE WATER HOSES ARE RUN.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Lifesaving
Issued 18 September 1992 Resolved
PROVIDE PROPER DOCUMENTATION TO VERIFY EXPIRATION DATE ON ALL PFD BATTERY LIGHTS AT ANNUAL CONTROL VERIFICATION EXAMINATION.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Fire Fighting
Issued 18 September 1992 Resolved
REPAIR BULKHEAD IN WAY OF FIRE DOOR MAGNETIC HOLD-BACK UNIT AS INDICATED ONVESSEL'S BRIDGE RECORD CARD.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Navigation
Issued 7 December 1991 Resolved
U.S. COAST PILOT NOT CURRENTLY UPDATED FOR THE TRANSITTED AREA.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 7 December 1991 Resolved
LIGHT LIST NOT CURRENTLY CORRECTED UP TO DATE.
Condition: Unknown
Due 13 March 1992
Resolved 13 March 1992
Navigation
Issued 7 December 1991 Resolved
UPDATE CHART 25670._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1991
Resolved 7 December 1991
Navigation
Issued 7 December 1991 Resolved
PROVIDE UPDATED LIGHT LIST._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1991
Resolved 7 December 1991
Accommodation/Occupational Safety
Issued 7 December 1991 Resolved
CLEAN ALL GREASE FROM ABOVE GRILL IN MAIN GALLEY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1991
Resolved 7 December 1991
Navigation
Issued 7 December 1991 Resolved
PROVIDE UPDATED COAST PILOT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1991
Resolved 7 December 1991
Electrical
Issued 26 June 1991 Resolved
UNTIL PERMANENT REPAIRS ARE MADE TO EMG DC/AC CONVERTER, A 24 HOUR WATCH SHALL BE MAINTAINED OVER THE VESSEL'S EMG GENERATOR AND TEMPORARY DIESEL EMERGENCY GENERATOR SET.
Condition: Unknown
Due 30 July 1991
Resolved 30 July 1991
Construction/Loadline
Issued 3 March 1990 Resolved
ENSURE WATER TIGHT DOOR PUMP #1 IS ADEQUATE TO ENABLE ALL W.T. DOORS TO BE CLOSED FROM THE BRIDGE IN LESS THAN ONE MINUTE. (DURING "TOTAL OPERATION" MODE.
Condition: Unknown
Due 3 March 1990
Resolved 3 March 1990
Electrical
Issued 21 March 1989 Resolved
PROVE PROPER OPERATION OF MAIN ENGINE ROOM SUPPLY FAN DAMPERS (INSTALLED ELECTRIC MOTORS OF INSUFFICIENT SIZE TO PROPERLY OPEN AND CLOSE DAMPERS).
Condition: Unknown
Due 21 March 1989
Resolved 21 March 1989
Documentation
Issued 20 December 1988 Resolved
PROVIDE WRITTEN OIL TRANSFER PROCEDURES FOR BUNKERING OPERATIONS.
Condition: Unknown
Due 20 December 1988
Resolved 20 December 1988
Engineering
Issued 20 December 1988 Resolved
INSTALL ALARM ON AUX. BOILERS TO INDICATE A BOILER FUEL TRIP DUE TO A FLAME FAILURE.
Condition: Unknown
Due 20 December 1988
Resolved 20 December 1988
Lifesaving
Issued 20 December 1988 Resolved
REVISE EMERGENCY PLAN TO DESIGNATE PERSON IN CHARGE OF LAUNCHING LIFERAFTS.
Condition: Unknown
Due 20 December 1988
Resolved 20 December 1988
Fire Fighting
Issued 20 December 1988 Resolved
PROVIDE A LATCH FOR THE DOUBLE SWING DOORS WHICH IS AUTOMATICLY ENGAGED BY THE RELEASE OF THE DOOR.
Condition: Unknown
Due 20 December 1988
Resolved 20 December 1988
Fire Fighting
Issued 20 December 1988 Resolved
FIRE SCREEN DOORS NEED A LOCAL RELEASE ON BOTH SIDES OF THE BULKHEAD.
Condition: Unknown
Due 20 December 1988
Resolved 20 December 1988
Construction/Loadline
Issued 20 December 1988 Resolved
MAKE PANTRY DOOR IN THE VERANDA CAFE (DECK 7) A-30 CLASS, THERE IS CURRENT-LY A 2 CM GAP AT THE BASE OF THE DOOR. THE PANTRY WILL NOT BE USED FOR THE PREPARATION OF HOT FOOD UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 20 December 1988
Resolved 20 December 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.