Records from 2016 to 2026. Most recent: inspection, 25 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 19
25 March 2026
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8323123
9 March 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8323078
17 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8113113
12 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8084263
8 April 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7891541
18 April 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7665873
15 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7651672
12 May 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7449093
28 March 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7415440
15 March 2021
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7146077
4 March 2021
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7149530
28 May 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6957900
22 April 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6667366
12 February 2019
Hull Examination · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6622434
26 April 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6400129
23 April 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6397612
29 March 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6112487
1 March 2017
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6096374
21 March 2016
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5831369
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 March 2026
Resolved
To maintain a valid Certificate of Inspection (COI), the vessel must complete its annual inspection within the timeframes outlined in 176.500(b)(1). The RUDEE MARINER has exceeded the required interval for its COI renewal inspection and is not authorized to operate until a valid COI has been issued.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2026
Resolution: Conducted COI RENEWAL inspection-issued Temp COI
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 17 April 2025
Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. STBD main engine does not have protective guard on rotating belt.
(46 CFR 182.01-5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2025
Resolved 1 May 2025
Resolution: Cleared via photo; installed guard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 April 2024
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Two life floats had areas of delamination and the color had faded. Considered not in serviceable condition.
46CFR180.175(a)
Action required: 10 - Deficiency Rectified
Resolved 8 April 2024
Resolution: Life floats replaced and attached, labeled IAW regulations. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 March 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Submit plans to MSC for approval.
46CFR181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 18 April 2023
Resolution: Vessel installed 6 X-Sense alarm system bluetooth smoke detectors.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2023
Resolved
On vessels described by 46 CFR 175.110(c), flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Provide plan to attending MI's.
46CFR185.364
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 18 April 2023
Resolution: Vsl does not have lithium batteries o/b.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2023
Resolved
For a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include but need not be limited to - (1) Training in the use and location of firefighting equipment and firefighting knowledge, including: (i) Location of firefighting appliances and emergency escape routes; (ii) Types and sources of ignition; (iii) Flammable materials, fire hazards and spread of fire; (iv) The need for constant vigilance; (v) Actions to be taken on board; (vi) Fire and smoke detection and automatic systems on board; and (vii) Classification of fire and applicable extinguishing agents. (2) The drills required by § 185.524, including fire location and fire type; and (3) Emergency egress training for each member of the crew, to occur for all members of the crew - (i) At least monthly while such members are employed on board the vessels; and (ii) Each time a crew member joins the crew of such vessel. Provide training program to attending MI's.
46CFR185.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 18 April 2023
Resolution: Vsl has 06 X-Sense Interconnected Bluetooth smoke detectors; is required to have 40B:C extinguishers; eqp on board exceeds what is required; and vsl provided a log containing mthly drills conducted.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 March 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List. Out of date Coast Pilot [name withheld] and paper charts.
46 CFR 184.420
Action required: 705 - Other - as specified
Due 4 April 2022
Resolved 1 April 2022
Resolution: Operator provided up to date charts, Light List and Coast Pilot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 March 2022
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring buoy missing SOLAS Type II retro.
46 CFR 185.604(h)
Action required: 705 - Other - as specified
Due 4 April 2022
Resolved 1 April 2022
Resolution: Operator applied SOLAS Type II retroreflective tape as required.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 March 2022
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers: On each life float and buoyant apparatus. Vessel name falling off 01 life float.
46 CFR 185.604(a)(2)
Action required: 705 - Other - as specified
Due 4 April 2022
Resolved 1 April 2022
Resolution: Operator stenciled vessel name on body of life float.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 March 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Wire run in tank room not watertight.
46 CFR 179.320(c)
Action required: 10 - Deficiency Rectified
Due 28 March 2022
Resolved 28 March 2022
Resolution: Operator installed firestop.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2022
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Strainer in tank room corroded away.
46 CFR 182.510(b)
Action required: 10 - Deficiency Rectified
Due 28 March 2022
Resolved 28 March 2022
Resolution: Operator installed new strainer
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2022
Resolved
Mechanically propelled "S" vessels which carry more than 49 passengers shall comply with the provisions of Subchapter "F" of this chapter. Found multiple sections of flexible hose installed in the bilge and fire main piping system.
46 CFR 182.40-5(b)
"Old-T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2022
Resolved 12 May 2022
Resolution: Operator replaced hos sections with VIEGA fittings and piping.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 May 2020
Resolved
The power fire pump shall be self-priming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Found fire pump seal leaking and showing signs of failure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2020
Resolved 29 May 2020
Resolution: Vessel owner replaced fire pump in kind. Witness operation of fire pump and bilge suction from engine room; all sat. Cleared 835.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2020
Resolved
The bilge suction shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Found bilge strainer in the engine room wasted Corrected on the spot, replaced with new strainer.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 May 2020
Resolved 28 May 2020
Resolution: replaced with new strainer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2020
Resolved
All electrical installations shall be to the satification of the Officer in Charge, Marine Inspection. Found battery connection posts had corrosion.
Action required: 10 - Deficiency Rectified
Due 28 May 2020
Resolved 28 May 2020
Resolution: Corrected on the spot. Cleaned and sprayed to prevent future corrosion.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2020
Resolved
Alcohol testing devices need to be carried on board each vessel. Found expired alcohol testing devices on board. Vessel is restricted to operate within two hours of their open collection site. Outfit vessel with valid alcohol testing devices to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2020
Resolved 29 May 2020
Resolution: Vessel owner provided evidence of new test strips. Uploaded photos in documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2019
Resolved
A vessel of at least 26 feet in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Bilge line is lazarette is corroded. Repair to the satisfaction of attending Marine Inspector.
46 CFR 182.510(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
Resolution: Verified bilge line was repaired IAW 46 CFR 182.510. Verified operation of bilge system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 February 2019
Resolved
Penatration in watertight bulkhead must be as high and as far inboard in the bulkhead as practicable and made watertight. Cable and pipe penetration were not watertight in 2nd hold and in the engine room. Ensure watertight bulkhead penetrations are made watertight to the satisfaction of attending Coast Guard Marine Inspector.
46 CFR 179.320(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2019
Resolved 20 February 2019
Resolution: Verified bulkhead penetrations made watertight using Firestop.
Engineering › Bilge Water Management System › Strainer
Issued 23 April 2018
Resolved
The aft three spaces are missing strainers on the bilge suction.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2018
Resolved 26 April 2018
Resolution: Inspected the aft three spaces for proper operation and placement of bilge strainer.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 23 April 2018
Resolved
Vessel's upper deck entraceways are not marked witht he maximum allowable number of passengers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 26 April 2018
Resolution: Inspected stenciling on the upper deck for the maximum passengers,all sat
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 23 April 2018
Resolved
Electric waterlights do not have approved batteries and one of the waterlights' bulb is cracked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 26 April 2018
Resolution: Inspected waterlight,which had been replaced inkind, all sat.