MAURY USCG vessel records Sign in
← All vessels

THOMAS SELMER

THOMAS SELMER is a 1985 freight ship. The Coast Guard has recorded 11 inspections since 1989, most recently in January 2003, along with 39 deficiencies and 1 operational control.

Records from 1989 to 2003. Most recent: inspection, 28 January 2003.

Built
1985
Last inspected
28 January 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8214061 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
325050
Flag
MALTA
—
Maury page id
psix-325050

Inspections, by type

…with no type recorded9
Years with a record 7 calendar years (1989–2003)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39540 - Regulatory (Subpart C or D), Gross Ton
26100 - Regulatory (Subpart C or D), Net Ton
65360 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

28 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1744432
28 August 2002 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1661529
1 June 2002 Annual Inspection · MARPOL Annex I Examination · Administrative Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1620786
29 May 2002 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1628374
5 May 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 71321
5 May 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 289504
11 April 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 276809
3 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 417569
1 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398035
16 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 387772
1 July 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 331202

Deficiency record · 39

Fire Fighting › Emergency Fire Pumps
Issued 1 June 2002 Resolved
Repair emergency fire pump. Currently the engine's heat exchanger is loose and is vibrating wildly. Also, the coolant fill cap is missing. SOLAS 74-52
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 4 June 2002
Resolution: Emergency fire pump repaired
Lifesaving › Launching Appliances
Issued 1 June 2002 Resolved
Prove proper operation of vessel's lifeboat davits. Currently the brake release had to be hit with a hammer to operate. SOLAS 74/III-4 LEGACY COMPONENT DESC: Winch Brake
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 4 June 2002
Resolution: The starboard lifeboat brake band was overhauled. proper operation of the davits was performed.
Pollution Prevention/Response › Prevention Equipment
Issued 1 June 2002 Resolved
Prove proper operation of the oily water separator. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 4 June 2002
Resolution: The O.W.S. was surveyed by class and found to working satisfacory. The overflow line guage glass was cleaned and a light installed behind it.
Pollution Prevention/Response › Prevention Equipment
Issued 1 June 2002 Resolved
Prove proper operation of the marine sanitation device. Crewman was not able to produce the needed chemical and stated that one pump has been removed for repairs. 33 CFR 159.7(c) LEGACY COMPONENT DESC: Marine Sanitation Device, Type 1
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 28 August 2002
Resolution: BOARDED VESSEL, MSD WAS FOUND SAT ACCORDING TO CLASS SOCIETY
Fire Fighting › Firemans Outfit
Issued 1 June 2002 Resolved
Provide fire fighting ensemble to fit the persons trained as the vessel's fire fighters. Currently one fire fighter was unable to fasten the suspenders or fasteners because the suit was too small. LEGACY COMPONENT DESC: Protective Clothing
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 28 August 2002
Resolution: BOARDED VESSEL, BULKHEAD FOUND SAT ACCORDING TO CLASS SOCIETY
Operations/Management › Drills/Instruction
Issued 1 June 2002 Resolved
Perform satisfactory fire drill in the presence of a USCG marine inspector. LEGACY COMPONENT DESC: Fire
Due 8 June 2002
Resolved 11 June 2002
Stability › Watertight Integrity
Issued 1 June 2002 Resolved
Repair watertight door from main deck to deck shop.
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 4 June 2002
Resolution: Dogs adjusted on the watertight door. Found closing satisfactory.
Engineering › Lubricating Oil Storage/Transfer System
Issued 1 June 2002 Resolved
Repair valve in steam line to lube oil heater. Valve is missing. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 4 June 2002
Resolution: The valves gasket was replaced and put back in the steam service line.
Documentation › Manuals/Policy Documentation
Issued 1 June 2002 Resolved
Provide proper bunkering procedures as outlined in 33 CFR 155.720-760. LEGACY COMPONENT DESC: Transfer Procedures
Action required: 703 - Prior to bunkering operations
Due 8 June 2002
Resolved 28 August 2002
Resolution: BUNKERING PROCEDURES FOUND SAT
Fire Fighting › Structural - A Class Divisions
Issued 1 June 2002 Resolved
Provide class approval for the current arrangement or install Class A fire boundary for the area (opening in bulkhead) from the deck shop to the main engine room. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 28 August 2002
Resolution: VESSEL BOARDED BULKHEAD FOUND SAT ACCORDING TO CLASS SOCIETY
Operations/Management › Equipment Service/Testing
Issued 1 June 2002 Resolved
Prove proper operation of vessel's EPIRB. SOLAS 74 amd IV-7.1.6.1 LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 4 June 2002
Resolution: A new EPIRB and bracket was installed
Fire Fighting › Structural - A Class Divisions
Issued 1 June 2002 Resolved
Provide class approval for the current arrangement or install Class A fire boundary for the area (opening in bulkhead) from the vent storeroom to the main engine room. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Condition: Unknown
Due 5 July 2002
Resolved 28 August 2002
Resolution: BOARDED VESSEL BULKHEAD FOUND SAT ACCORDING TO CLASS SOCIETY
Engineering
Issued 5 May 2001 Resolved
HAVE CLASS PROVIDE A REPAIR SCHEDULE FOR THE AFT MAIN ENGINE LUBE OIL PURIFIER. SOLAS 74 I/11
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Lifesaving
Issued 5 May 2001 Resolved
CLASS NEEDS TO INVESTIGATE THE BRAKE ASSEMBLY ON THE STBD LIFEBOAT. IT TOOK CONSIDERABLE EFFORT TO "BREAK THR BOAT FREE" OFF THE DAVITS DURING TESTING. ALSO, THE BREAK HANDLE APPEARS TO BE IMPEADED BY BENT OVER MOTOR SWITCH. SOLAS 74 III/36
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Lifesaving
Issued 5 May 2001 Resolved
THE ENTIRE CREW IS SHORT ON SLEEP. CREW MEMBERS MUST GET REST IAW STCW 95 VIII/1. A MINIMUM OF 6 HOURS CONTINUOUS REST IS NECESSARY FOR EACH CREW MEMBER IMMEDIATELY. STCW 95 VIII/1.
Condition: Unknown
Due 13 May 2001
Resolved 8 May 2001
Fire Fighting
Issued 5 May 2001 Resolved
DEMONSTRATE A PROPER FIRE DRILL IN THE PRESENCE OF US COAST GUARD INSPECTOR. SOLAS 74 II/18.3
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Navigation
Issued 5 May 2001 Resolved
CORRECT RUDDER ANGLE INDICATOR TO ALLIGN WITH THE MAIN STEERING GEAR. OFF BY 6 ON STD AND 10 ON PORT. CLEAN THE PAINT OFF RUDDER ANGLE INDICATOR FORCLEAR VIEWING FROM ALL ANGLES. SOLAS 74 II/29
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Fire Fighting
Issued 5 May 2001 Resolved
REPAIR BROKEN FIRE HYDRANT HANDLE ON FOCSLE. SOLAS 74 III/36
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Lifesaving
Issued 5 May 2001 Resolved
HAVE CLASS INVESTIGATE ARRANGEMENT OF LIFEBOAT DAVITS REGARDING THE USE OF TRICING PENENTS AND BOWSING TACKLES. RESOLVE CONFLICTS AND WITNESS PROPER LOWERING OF STBD LIFEBOAT. SOLAS 74 III/36
Condition: Unknown
Due 13 May 2001
Resolved 8 May 2001
Deck/Cargo
Issued 11 April 2000 Resolved
EXCESSIVE HYDRAULIC LEAKS ON CARGO HOLDS 2, 3, 5, 7, AND 8.
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Construction/Loadline
Issued 11 April 2000 Resolved
LOAD LINE MARKINGS NOT VISIBLE
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Unknown
Issued 11 April 2000 Resolved
safety radio certificate expired
Condition: Unknown
Due 11 April 2000
Resolved 20 April 2000
Lifesaving
Issued 3 June 1998 Resolved
LIFE RAFTS MISSING WEAK LINKS._x001C_ _x001C_ SOLAS 74(AMENDED) REG III/38.6_x001C_
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Navigation
Issued 16 February 1996 Resolved
PROVE OPERATION OF ON BOARD "ARPA" RADAR IN ACCORDANCE WITH SOLAS 74 AMENDED IV/12(j).
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Engineering
Issued 16 February 1996 Resolved
PROVIDE ON BOARD COMPLETE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Lifesaving
Issued 16 February 1996 Resolved
PROVIDE/INSTALL MUSTER LIST IN ENGINE ROOM. SOLAS 74 (AMENDED) III/8.3
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Fire Fighting
Issued 16 February 1996 Resolved
REPLACE TWO (2) DETERIORATED/UNSERVICEABLE EXTINGUISHERS IN ENGNE ROOM (LOWEST LEVEL). SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Fire Fighting
Issued 16 February 1996 Resolved
RENEW, REPAIR ALL FROZEN/CORRODED FIRE HOSE NOZZLES IN ENGINE ROOM. SOLAS 74 (AMENDED II-2/21
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Fire Fighting
Issued 16 February 1996 Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP. SOLAS 74 (UNAMENDED) II- 2/52(b)(ii)
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Navigation
Issued 16 February 1996 Resolved
PROVIDE CONTINUOUS RECORDING DEVICE FOR ON BOARD ECHO DEPTH SOUNDING EQUIPMENT. 33 CFR 164.35(i).
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Lifesaving
Issued 16 February 1996 Resolved
PROVIDE EIGHT (8) SERVICEABLE LIFE RING BUOYS, FOUR (4) OF WHICH SHALL BE FITTED WITH LIGHTS, AND TWO (2) OF WHICH SHALL BE FITTED WITH BUOYANT LIFE LINES. SOLAS 74 AMENDED III/19.2, SOLAS 74 UNAMENDED III/21(d)&(e).
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Lifesaving
Issued 16 February 1996 Resolved
PROVIDE/INSTALL RETRO-REFLECTIVE MATERIAL ON ALL LIFE RING BUOYS. SOLAS 74(AMENDED) III/30.2.7
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Navigation
Issued 16 February 1996 Resolved
PROVIDE AND POST EMERGENCY STEERING INSTRUCTIONS WITH SIMPLE BLOCK DIAGRAM ON NAVIGATING BRIDGE.
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Lifesaving
Issued 16 February 1996 Resolved
PROVIDE/INSTALL RETRO-REFLECTIVE MATERIAL WHERE MISSING ON PORT AND STARBOARD LIFEBOATS IN ACCORDANCE WITH SOLAS 74 AMENDED III/30.2.7
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Lifesaving
Issued 16 February 1996 Resolved
PROVE OPERATION OF STARBOARD LIFEBOAT DAVIT LIMIT SWITCHES. SOLAS 74 III/36(k)
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Lifesaving
Issued 16 February 1996 Resolved
PROPERLY CONFIGURE PORT INFLATABLE LIFERAFT PAINTER LINE AND HYDROSTATIC RELEASE ARRANGEMENT IN ACCARDANCE WITH SOLAS 74 AMENDED III/29.
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Lifesaving
Issued 16 February 1996 Resolved
PROVIDE/INSTALL RETRO-REFLECTIVE MATERIAL ON ALL LIFE JACKETS. SOLAS 74 (AMENDED) III/30.2.7
Condition: Unknown
Due 18 February 1996
Resolved 22 February 1996
Navigation
Issued 1 July 1989 Resolved
33CFR164.33(A)(2)(I) NO CURRENT U.S. COAST GAURD PILOT(1978 EDITION ON BRD)
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Navigation
Issued 1 July 1989 Resolved
33CFR164.33(A)(2)(II) NO CURRENT COAST GAURD LIGHT LIST (1983 EDITION)
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.