MAURY USCG vessel records Sign in
← All vessels

AGIOS NEKTARIOS

AGIOS NEKTARIOS is a 1988 freight ship. The Coast Guard has recorded 23 inspections since 1989, most recently in April 2006, along with 32 deficiencies — 2 with no resolution recorded — and 7 operational controls.

Records from 1989 to 2006. Most recent: inspection, 13 April 2006.

Built
1988
Last inspected
13 April 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8723610 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
325395
Flag
ESTONIA
—
Maury page id
psix-325395

Inspections, by type

…with no type recorded19
Years with a record 11 calendar years (1989–2006)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it31649 - Convention (Subpart B), Gross Ton
52650 - Dead Weight, Ton
17558 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

13 April 2006 PII Safety Exam · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2623826
27 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2610833
16 November 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2535884
9 November 2005 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2531605
7 November 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2529985
7 November 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2530008
28 October 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2530659
25 October 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2521608
21 October 2005 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2519448
15 October 2005 ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2515048
11 October 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2512506
3 December 2003 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1958080
26 March 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 640037
6 February 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 286965
28 February 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 413139
6 January 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 399255
28 November 1995 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 385086
5 November 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 682093
14 October 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 353734
18 December 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 538189
8 April 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 342977
13 February 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 335311
1 February 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 328331

Deficiency record · 32

Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 April 2006 No resolution recorded
STEERIN GEAR COMPARTMENT DID NOT HAVE ARRANGEMENTS FOR NON-SLIP SURFACES. TO SATISFACTION OF US COAST GUARD
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 April 2006 No resolution recorded
ENGINE ROOM MISSING NUMEROUS LIGHT COVERS. ALSO MISSING COVERS IN STAIWELL. TO SATISFACTION OF US COAST GUARD
Action required: 15 - Rectify deficiencies by next port
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 13 April 2006 Resolved
SOLAS TRAING MANUAL AND FIRE SAFETY MANUAL WERE NOT LOCATED IN REQUIRED AREAS
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2006
Resolved 13 April 2006
Resolution: MANUALS WERE RETURNED TO CREW AND OFFICER LOUNGES
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 15 October 2005 Resolved
Ships power failure alarm for steering pumps not functioning proplerly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2005
Resolution: Conducted administrative inspection of technician report.
Construction/Loadline › Structures
Issued 3 December 2003 Resolved
DECK HATCHES OVER BOSN HOLD ARE NOT WEATHER TIGHT. REPAIR AS ORIGINAL. LEGACY COMPONENT DESC: Scuttle
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 4 December 2003
Lifesaving › Launching Appliances
Issued 3 December 2003 Resolved
LIMIT SWITCH NEEDS TO BE ADJUSTED TO PREVENT DAMAGE TO THE LIFEBOAT. LEGACY COMPONENT DESC: Davit
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 4 December 2003
Lifesaving › Lifeboat
Issued 3 December 2003 Resolved
BOTH PORT AND STBD LIFEBOATS NEED TO BE PROPERLY LABELED. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 4 December 2003
Engineering › Steering Gear System
Issued 3 December 2003 Resolved
RUDDER ANGLE INDICATOR BETWEEN THE BRIDGE AND STEERING GEAR ROOM IS OFF BY 5 DEGREES. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 4 December 2003
Fire Fighting › Miscellaneous Items
Issued 3 December 2003 Resolved
UPDATE FIRE CONTROL PLAN TO REFLECT EEBD PLACEMENT.
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 4 December 2003
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 3 December 2003 Resolved
APPROX 6" OF STANDING WATER FOUND IN THE HOSPITAL'S HEAD, DEWATER AND REPAIR LEAK.
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 15 October 2005
Resolution: Inspected by CG boarding officer.
Fire Fighting › International Shore Connection
Issued 3 December 2003 Resolved
REPLACE MISSING INTL SHORE CONNECTION.
Action required: 705 - Other - as specified
Due 3 December 2003
Resolved 4 December 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 December 2003 Resolved
NUMEROUS INDICATOR LIGHTS ON THE CONTROL PANEL IN ENGINE CONTROL ROOM ARE BURNED OUT.
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 4 December 2003
Engineering › Diesel Engine (auxiliary)
Issued 3 December 2003 Resolved
SHIP SERVICE GENERATORS MISSING GUARDS ON SIDE OF PISTON HEAD.
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 4 December 2003
Navigation
Issued 6 February 2001 Resolved
VESSELS ECHO DEPTH SOUNDER IS INOPERABLE_x001C_ _x001C_ VESSEL REQUIRED REPAIR TO ECHO SOUNDER PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 6 March 2001
Resolved 3 December 2003
Navigation
Issued 6 February 2001 Resolved
VESSEL FAILED TO NOTIFY COTP LA/LB OF INOPERABLE ECHO DEPTH SOUNDER._x001C_ _x001C_ VESSEL REQUIRED TO PROVIDE $10,000 LETTER OF UNDERTAKING PRIOR TO DEPARTURE.
Condition: Unknown
Due 10 February 2001
Resolved 10 February 2001
Navigation
Issued 6 February 2001 Resolved
VESSELS ARPA RADAR DOES NOT HAVE APRA LABEL PERMANENTLY AFFIXED._x001C_ _x001C_ VESSEL REQUIRED TO CORRECT PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN.
Condition: Unknown
Due 6 March 2001
Resolved 3 December 2003
Lifesaving
Issued 6 February 2001 Resolved
3 OF VESSELS 4 LIFERAFTS WERE NOT SECURED WITH FREE-FLOAT ARRANGEMANT. NO WEAK LINKS WERE ATTACHED._x001C_ _x001C_ CORRECTED ON SCENE.
Condition: Unknown
Due 10 February 2001
Resolved 10 February 2001
Accommodation/Occupational Safety
Issued 6 February 2001 Resolved
VESSELS MARINE SANITATION DEVICE IS NOT PROPERLY LABELED._x001C_ 33 C.F.R. 159.55(a)(6)_x001C_ PROVIDE PROPER LABEL PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN.
Condition: Unknown
Due 6 March 2001
Resolved 3 December 2003
Accommodation/Occupational Safety
Issued 6 February 2001 Resolved
VESSEL HAS TWO MIDDLE DECK RAILS NEAR #6 CARGO HOLD (PORT SIDE) THAT ARE BROKEN._x001C_ _x001C_ VESSEL TO REPAIR PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN.
Condition: Unknown
Due 6 March 2001
Resolved 3 December 2003
Fire Fighting
Issued 28 February 1998 Resolved
VESSEL HAD FIREPLANS ON WATERTIGHT COMPARTMENTS ON DECK. MUST PROVIDE A_x001C_ COPY TO BE PERMANENTLY EXHIBITED BY CREW ACCOMODATIONS. IAW SOLAS 74 CH II-2 REG 20.
Condition: Unknown
Due 10 February 2001
Resolved 10 February 2001
Lifesaving
Issued 28 February 1998 Resolved
PROVIDE 4 KG LIFEBUOYS ON PORT AND STARBOARD BRIDGE WINGS IAW SOLAS CH III REG 31.1.7.
Condition: Unknown
Due 10 February 2001
Resolved 10 February 2001
Lifesaving
Issued 28 February 1998 Resolved
DEMOSTRATE LOWERING AND IN WATER OPERATION OF LIFEBOAT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR BY NEXT US PORT.
Condition: Unknown
Due 10 February 2001
Resolved 10 February 2001
Documentation
Issued 28 February 1998 Resolved
PROVIDE CLASS REPORT ON "C-1" MARKING BY THE LOADLINE, IAW ILLC 1966 REG 6
Condition: Unknown
Due 10 February 2001
Resolved 10 February 2001
Documentation
Issued 28 November 1995 Resolved
33 CFR 155.820(b) The vessel did not have record of the last annual pressure test of the bunker piping system which is required by 33 CFR 156.170(c)(4) & (f).
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Navigation
Issued 28 November 1995 Resolved
33 CFR 88.05 Vessel did not have a copy of the Inland Navigation Rules.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Documentation
Issued 28 November 1995 Resolved
33 CFR 155.740 The vessel's transfer procedures were in Russian and could not be verified to be in compliance. Vessel created procedures in English which were found in compliance.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Documentation
Issued 28 November 1995 Resolved
33 CFR 155.450 The vessel did not have a "Discharge of Oil Prohibited" placard in the engine room.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Engineering
Issued 28 November 1995 Resolved
SOLAS The flame screens in the vessel's oil vents were wasted.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Navigation
Issued 14 October 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 October 1992
Resolved 22 October 1992
Navigation
Issued 14 October 1992 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER WITHOUT A COAST GUARD LIGHT LIST OR EQUIVALENT ON BOARD. VESSEL WAS BOARD IN VANCOUVER, WASHINGTON ON 14OCT92 AND DID NOT HAVE A LIGHT LIST ON BOARD AT THAT TIME.
Condition: Unknown
Due 22 October 1992
Resolved 22 October 1992
Navigation
Issued 14 October 1992 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER WITH NO TIDE TABLES ON BOARD. VESSEL WAS BOARDED IN VANCOUVER, WASHINGTON, ON 14OCT92 AND DID NOT HAVE TIDE TABLES ON BOARD AT THAT TIME.
Condition: Unknown
Due 22 October 1992
Resolved 22 October 1992
Navigation
Issued 14 October 1992 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER WITH NO TIDAL CURRENT TABLES ON BOARD. VESSEL WAS BOARDED ON 14OCT92 IN VANCOUVER, WASHINGTON AND DID NOT HAVE A TIDAL CURRENT TABLE ON BOARD AT THAT TIME.
Condition: Unknown
Due 22 October 1992
Resolved 22 October 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.