Records from 2007 to 2025. Most recent: inspection, 24 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 16
24 September 2025
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8236290
8 October 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8001707
22 September 2023
Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7794190
19 April 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7676372
18 May 2022
Plan Review "T" Boat · COI Inspection · Administrative Inspection · Construction Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7452487
6 January 2022
Construction Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7382585
4 December 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7362172
23 November 2021
Inclining Experiment
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7361540
9 November 2021
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7348444
4 February 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7137419
5 November 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6840441
13 November 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6578443
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360347
14 November 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6302039
27 January 2017
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6076215
2 November 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6031369
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 September 2025
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional tests or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The owner canceled a scheduled annual inspection due to the vessel not being ready to undergo tests of equipment to determine suitability. Vessel is to complete a successful annual inspection prior to carriage of passengers to the satisfaction of an attending marine inspector.
46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2026
Resolution: COI is expired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 September 2023
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. Vessel has only one life buoy in service and 2 are out of service for maintenance. Return the repaired life buoys to service.
46 CFR 180.70(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2023
Resolution: All life buoys installed correctly and returned to service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 September 2023
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. The bilge pump in the lazarette was clogged preventing drainage of the water from the space. Clear debris from pump and line.
46 CFR 182.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Lazarette bilge suction line cleared and proved both fixed powered bilge pumps were capable of dewatering the compartment.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 September 2023
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Unable to conduct drills with CG Marine inspector on board. Conduct drills with CG Marine inspector on board.
46 CFR 176.810(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2023
Resolution: Vessel crew satisfactorily completed fire and MOB drills.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2023
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:Non-rechargeable or non-refillable extinguishers must be inspected and maintained in accordance with NFPA 10; however, the annual maintenance need not be conducted by a certified person and can be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessels fire extinguishers need to be serviced. Service fire extinguishers and log the service date.
46 CFR 176.810(b)(1)(iii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2023
Resolution: Vessel crew serviced fire extinguishers and provided log showing monthly inspections/service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 September 2023
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Waterlight batteries were expired. Replace batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2023
Resolved 28 September 2023
Resolution: Waterlight batteries were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 September 2023
Resolved
The equipment required for life floats and buoyant apparatus must meet the following specifications; The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The batteries in the floating waterlight were expired. Replace expired batteries.
46 CFR 180.175(f)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2023
Resolved 28 September 2023
Resolution: Replaced expired batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 September 2023
Resolved
Except as allowed by paragraph (e) of this section, each vessel certificated to operate on a limited coastwise route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. One of the vessels 22 person life float was in operable. Until life raft is replaced vessel will be limited to 68 passengers beyond 3NM from shore, or vessel may carry 100 passengers but must stay within 3NM of shore.
46 CFR 180.205(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 April 2024
Resolution: Received confirmation from vessel Captain that company will not replace deficient life float. Company would instead like a route reduction to 3 miles from shore.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 November 2021
Resolved
Vessel had re-powered both MDEs. Both engines are controlled by a microprocessor and are required to have a Design Verification Test Procedure (DVTP) submitted and approved/witnessed. A DVTP is to be submitted to MSC for review/approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2022
Resolution: DVTP/QFA approvals and testing completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2021
Resolved
F/O remote shut off valve handles not labeled. Label remote F/O shut off handles at source.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2022
Resolution: F/O shut off valve handle labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2021
Resolved
Watertight bulkhead in lazarette has 03 penetrations that are not watertight, blkd is listed as a WTB on Stability letter. Make WTB watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2022
Resolution: Penetrations sealed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 November 2021
Resolved
Spanner wrench missing from stbd fire station. Replace missing spanner wrench.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2022
Resolution: Spanner wrench provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 9 November 2021
Resolved
Aft passenger area reconfigured to allow passenger access to stern area where blkd was removed. Bulwark is not 39.5". Install bulwark to meet 39.5" requirement
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2022
Resolution: Rail installed at 39.5 inches.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 November 2021
Resolved
Life Float weak link not of the proper strength. Install proper weak link.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 August 2022
Resolution: Life float links provided.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 4 February 2021
Resolved
Emergency exit signs are missing and need to be posted. 46CFR185.606
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2021
Resolved 16 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 February 2021
Resolved
Life jacket donning placards are missing. Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. 46CFR185.516
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2021
Resolved 16 February 2021
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 5 November 2019
Resolved
Vessel is required to have visual and audible alarm at the operating station to indicate a high water level in each of the unmanned spaces noted by CFR.
#2 hold high level bilge alarm did not sound an audible warning in operating station, only visual.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 11 November 2019
Resolution: Vessel fixed the high level bilge alarm on #2 hold, and produced video evidence that it produces an audible and visual alarm at the operating station upon activation.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 November 2018
Resolved
Vsl lifefloats are required to be in good serviceable condition. Lifefloats have cracks in exterior rubber.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2018
Resolved 14 November 2018
Resolution: Repaired with JimBuoy paint.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 November 2017
Resolved
Multiple lifejackets found to have deteriorated reflective tape - 46 CFR 176.808(e) - 30 Days (14DEC2017); Passenger count limited to 129 persons.
Due 14 December 2017
Resolved 14 November 2017
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2017
Resolved
Crop and renew bow deck steel. 46 CFR 177.300(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Conducted all neccesary inspections, plate has been renewed to original condition.
Construction/Loadline › Hull › Bottom Plating
Issued 27 January 2017
Resolved
Crop and renew approximately 8' by 3' section of steel underneath engine room on port side. 46 CFR 177.300(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Resolution: Conducted all neccesary inspections, plate has been renewed to original condition.