Records from 2008 to 2026. Most recent: inspection, 6 July 2026.
Inspection history · 77
6 July 2026
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8431941
7 June 2026
Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8395001
27 May 2026
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8382267
15 April 2026
Appeal · Administrative Inspection
Administrative · USCG East District · USCG East District (CGD-E) · Activity 8349834
7 April 2026
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8344348
24 March 2026
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8331383
2 January 2026
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8289327
2 January 2026
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8291535
9 December 2025
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8279640
24 September 2025
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8229396
25 June 2025
Examination of Repairs · Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8167263
26 March 2025
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8100411
23 February 2025
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8083082
6 February 2025
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8076127
18 December 2024
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8048758
20 November 2024
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8040034
12 September 2024
COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8001473
29 August 2024
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7992603
29 August 2024
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7997715
11 July 2024
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7943350
11 March 2024
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7876959
1 March 2024
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7872944
7 December 2023
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7834524
16 October 2023
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7809039
20 September 2023
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7792014
24 July 2023
Hull Examination · Internal Structural Exam · Special · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7757732
18 July 2023
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7745837
9 May 2023
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7683763
9 March 2023
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7648078
27 January 2023
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7657647
14 December 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7608966
7 December 2022
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7605386
26 September 2022
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7567887
22 September 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7564568
22 September 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7590622
15 September 2022
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7558914
11 May 2022
COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7448192
16 March 2022
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7411530
7 December 2021
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7361658
22 September 2021
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7314250
16 September 2021
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7314760
16 September 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7316314
31 August 2021
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7311033
21 August 2021
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7292685
16 June 2021
COI Inspection · Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7221307
2 March 2021
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7162528
15 June 2020
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6977333
16 April 2020
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6923773
15 January 2020
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6866327
19 October 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6844363
13 August 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6784015
13 August 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6784360
5 August 2019
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6773868
24 July 2019
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6656642
24 April 2019
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6606942
11 April 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6661005
11 April 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6690833
30 January 2019
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6566465
15 August 2018
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6513169
18 July 2018
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6449569
18 April 2018
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6381284
21 February 2018
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358695
15 December 2017
Examination of Repairs · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6331926
13 October 2017
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6287184
3 October 2017
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6280160
13 September 2017
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6266562
31 May 2017
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6163607
20 April 2017
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6104365
1 February 2017
Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6056930
21 October 2016
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6029276
21 October 2016
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6029643
11 October 2016
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5989019
24 August 2016
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5982891
1 August 2016
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5960157
27 July 2016
Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5908585
21 April 2016
Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5828525
27 January 2016
Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5781414
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2026
Resolved
All vessels except unmanned barges shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment except for ballast, oil and water tanks which have acceptable means for filling and emptying independent of the bilge system.
Vessel must prove system capability of pumping and draining water from each watertight compartment prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 24 March 2026
Resolved 24 March 2026
Resolution: Crew tested all bilge suctions sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 January 2026
No resolution recorded
The rescue boat launching and recovery arrangement does not comply with 46 CFR 199.160(e) and 199.160(g) because the installed 1,500-lb davit cannot recover the rescue boat with its full complement of persons and equipment; NCDOT must either upgrade the rescue boat/davit system to full regulatory compliance or obtain an approved exemption from CGD East in accordance with 46 CFR § 199.20(d) prior to return to service following the next scheduled drydock.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2025
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F of this chapter.
Both port and starboard packing glands were witnessed to be excessively leaking. Local sea trails authorized for repair.
46 CFR 77.03-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 September 2025
Resolution: Ajusted packing gland, sea trials SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2025
Resolved
Each power bilge pump must develop a suction velocity of not less than 400 feet per minute. Bilge suction in MSD compartment, #1 Void, and forepeak was not operational. Demonstrate operation to the satisfaction of the attending MI.
46 CFR 56.50-55(c)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 September 2025
Resolution: All suction valves were taken apart and cleaned, re installed and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2025
Resolved
Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. Satisfactory PSTPs were not completed and able to be demonstrated to attending MI.
46 CFR 61.40-6(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 September 2025
Resolution: Read the instructions on the new test machine and found out different settings were adjustable. Re tested SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 25 June 2025
Resolved
If port lights are fitted in spaces used alternatively for the carriage of cargo or passengers as permitted by § 171.116(d) of this chapter, dead covers must be fitted on the port lights. On both mens and womens heads, port light covers are missing dogs and or nuts to properly secure the port light covers. Conduct repairs to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 28 July 2025
Resolution: Manufactured new dogs and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 February 2025
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter.
MI received notification from the [name withheld] stating while conducting morning checks on the M/V KINNAKEET, black smoke was discovered in the E/R. Crew determined STBD MDE starter never disengaged after start-up. The STBD MDE battery bank then exploded. Conduct repairs IAW manufactures recommendation and provide proof of proper operation to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2025
Resolution: NCDOT provided tangible evidence proper repairs were made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 February 2025
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter.
MI received notification from the [name withheld] stating the M/V KINNAKEET discovered a water leak from the installed hard piping from the water pump to the blower on the port MDE. Conduct repairs IAW manufactures recommendation and provide proof of proper operation to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2025
Resolution: NCDOT maintenance replaced coolant hose with in-kind material. Performed test. All SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 18 December 2024
Resolved
The inspector shall examine all accessible parts of the vessel's equipment to be assured that it is in a satisfactory condition. The potable water pump is not making pressure due to faulty head tank(leaking). Make effective repairs.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2025
Resolved 6 January 2025
Resolution: Rcvd objective evidence.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 25 September 2024
Resolved
Piping systems used where the fluid temperature exceeds 150 °F must be suitably insulated as necessary to preclude injury to personnel. Missing insulation cooling outlet pipes for both main engines.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 9 October 2024
Resolution: Proper insulation installed on pipes.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 September 2024
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. Found exposed pulley on injection pump for MSD. Extend existing cover over the belts.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 September 2024
Resolution: Existing cover was extended to cover the belts.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 25 September 2024
Resolved
Each passenger vessel of less than 500 tons gross tonnage must carry at least one rescue boat approved under approval series 160.156 that is equipped as specified in table 199.175 of this part. During inspection of rescue boat that was replacing another vessels damaged rescue boat, fiberglass was cracked, wasted retro tape and extinguisher bracket.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 20 November 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 25 September 2024
Resolved
Each port light located between the bulkhead deck and the next deck above the bulkhead deck must have an inside dead cover than can be secured watertight. Missing dogs on port lights in both restrooms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 9 October 2024
Resolution: Portholes on the bathroom not required to be watertight since the bulkhead are not watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 September 2024
Resolved
All vessels except unmanned barges must be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment except for ballast, oil, and water tanks. Several service valves and check valves were taken apart by the crew to conduct maintenance to prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 September 2024
Resolution: Corrected on the spot. Crew conducted maintenance and proved proper operation of the bilge system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2024
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness. MI was notified stating vessel loss control air pressure on the vessel. Make in-kind repairs to equipment and make ready for attending MI.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 29 August 2024
Resolution: NCDOT Maintenance discovered and leak in the control air line and repaired it. System tested all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 July 2024
Resolved
Found L/O sending unit inop on EDG.
Action required: 10 - Deficiency Rectified
Due 11 July 2024
Resolved 11 July 2024
Resolution: Maintenance department cleaned wiring/ sending unit tested satisfactory
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 March 2024
Resolved
WATERTIGHT DOORS INSTALLED BELOW SEVEN FEET ABOVE THE DEEPEST LOAD LINE ARE REQUIRED TO BE WATERTIGHT. DOOR TO THE AUXILLIARY MACHINERY SPACE HAS A SOFT GASKET INSTALLED MAKING THE DOOR WEATHERTIGHT. VSL MUST PROVIDE CORRECT GASKET TO ENSURE WATERTIGHT DOOR IN THAT LOCATION IS WATERTIGHT.46 CFR 170.255
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2024
Resolution: Received photo evidence and QA attestation the door gasket has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2024
Resolved
EXHAUST SYSTEMS FOR INTERNAL COMBUSTION ENGINES MUST BE FREE OF ANY LEAKS TO PREVENT ATMOSPHERIC CHANGES WITHIN THE SPACE INSTALLED. STBD MDE HAS AN EXHAUST LEAK. VSL MUST PROVIDE EXHAUST SYSTEM FREE OF EXHAUST LEAKS.46 CFR 58.01-35
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2024
Resolution: QA [name withheld] attested that exhaust leak was fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 March 2024
Resolved
The installation of all systems of an electrical engineering or interior communications nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter J (Electrical Engineering) of this chapter. Systems of this type include the following: Ship's service generating systems.
Vessel captain notified SCC stating the crew discovered oil in the #1 generator's coolant system. Crew discovered the oil cooler was leaking. Provide findings and repair/replace faulty equipment with in-kind equipment. Ensure proper test trials are conducted. Notify Marine Inspector once repairs and test trials are completed.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2024
Resolution: NCDOT replaced the oil cooler on the M/V KINNAKEET's #1 Generator. The engine has been flushed. Fluids, including the oil, have been changed. The Generator has been run and brought up to operating temperature and all has worked properly.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 7 December 2023
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. During re-inspection, MI discovered the forward seating arrangement was not properly secured. Secure seating IAW manufactures specifications and make available for inspection by attending MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 11 March 2024
Resolution: Original rescue boat had been repaired and was back in service at the time of this re-inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 December 2023
Resolved
Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use. During re-inspection, MI discovered the installed raft light on sponson was expired. Replace expired raft light with valid in-kind equipment and make available for inspection by attending MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2024
Resolved 14 December 2023
Resolution: Light was replaced and verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 October 2023
Resolved
An inspection, either general or partial depending upon the circumstances, shall be made whenever any important repairs or alterations are undertaken. Captain notified Command Center, the engineers discovered an oil cooler leak on the #1 SSDG.
The vessel is authorized to conduct sea trials/load trials with no passengers/vehicles. Provide MI with repairs/attestation letter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2023
Resolution: Crew replaced cooler and completed test run. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 March 2023
Resolved
All valves and closing appliances which may be required to operate for damage control purposes shall be conspicuously marked with 1" block letters. Vsl installed bilge piping system has multiple valves which are not labeled. Vsl must provide labeling for all valves in the bilge piping system.46 CFR 78.47-38
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 March 2023
Resolution: Recvd photographic evidence from NCDOT showing proper labeling of emergency bilge suction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2022
Resolved
The installation of all systems of an electrical engineering or interior communications nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter J (Electrical Engineering) of this chapter. Systems of this type include the following: Electric propulsion and propulsion control systems. Captain reported loss of throttle response on the STBD MDE. Make permanent repairs to the satisfaction of the attending marine inspector.
Action required: 10 - Deficiency Rectified
Due 14 December 2022
Resolved 14 December 2022
Resolution: NCDOT replaced clutch actuator and pin in clevis. Troubleshooting repairs tested SAT.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 7 December 2022
Resolved
The means of communication and calling must be a reliable means of voice communication and must be independent of the vessel's electrical system. Location EOS: The sound power phone knob selector detent was found is wasted. Renew in kind or make proper repairs.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2022
Resolved 13 December 2022
Resolution: The sound power phone knob selector detent was renewed in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 December 2022
Resolved
All valves which may be required to be operated for damage control purposes in case of emergency shall be conspicuously marked with letters at least 1 inch high identifying the control and the direction of operation. The bilge suction valve for MSD space not properly labeled.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2022
Resolved 13 December 2022
Resolution: 705 - Other - as specified: 7days
The bilge suction valve for MSD space is now properly labeled.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 15 September 2022
Resolved
This subpart prescribes regulations governing the design and construction of Marine Sanitation Devices. Standing water was found on men's bathroom deck. Repair leak on F/W inlet piping to toilet.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 28 September 2022
Resolution: New supply piping installed from deck to shutoff valve and new gate valve installed in men's head. No water leaking at this time.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 June 2022
Resolved
The inspection shall be such as to ensure that the vessel as regards the life savings appliances is in satisfactory condition and fit for the service for which is intended. The rescue boat was found inoperable during the drill. Provide cause of casualty and make effective repairs. Prove proper operation to the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 16 June 2022
Resolution: Spare outboard engine installed and conducted operational test.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 16 June 2022
Resolved
Automatic operation of a safety control must be alarmed in the machinery spaces and at the cognizant remote control location. The high jacket water alarm for #1 SSDG is showing intermittent lights on EOS panel. Make effective repairs and prove proper operations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 24 June 2022
Resolution: New J/W sensor was installed, cleaned card internals, and reinstalled. Operating as designed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2021
Resolved
A survey either general or partial, according to the circumstances shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. The master reported a crewman discovered a pin hole leak in the port main diesel engine fuel line on the outboard side. Trouble shoot make repairs (replace in-kind) operationally test to satisfaction of the coast guard, prior to carriage of passengers or cargo.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2021
Resolved 17 September 2021
Resolution: Attended vessel, inspected repairs, and accepted masters attestation.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 August 2021
Resolved
Where extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation must meet the requirements of this part. Vessel reported that the port fire pump is inoperable. Make permanent repairs to the port fire pump and prove proper operation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2021
Resolved 21 August 2021
Resolution: Cleared to the satisfaction of the CG. Shaft coupling's set screws were installed and pump was satisfactorily tested.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 June 2021
Resolved
Port side engine room closure device is missing securing hardware, preventing the closure from being isolated in the event of fire.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2021
Resolved
The steering hoses at motor/pump are damaged replace in kind as marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 June 2021
Resolved
The port and std MDE’s air sep hoses are damaged (as marked) inspect entire system and replace damaged portions as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 31 August 2021
Resolution: Port MDE air sep hose was replaced.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 16 June 2021
Resolved
The pilot house steering failure alarms are inoperative. Prove proper operation to the satisfaction of the USCG.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2021
Resolved
The port MDE high pressure fuel oil lines are chaffed (damaged) replace lines marked by MI, inspect the remaining line and properly secure in brackets.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 16 June 2021
Resolved
The engineers control station, has loose components (alarm panel) and gauges. Make properly secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 June 2021
Resolved
The port and std SSDG’s have damaged supply and return fuel lines (as marked) which need replacement in kind.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 June 2021
Resolved
The port and std SSDG’s have keel cooler piping, missing insulation on hot surfaces. Replace or repair in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2021
Resolved
The engine room, battery ground isolator is damage ivo battery banks. Replaced in kind.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2021
Resolved
The port and std MDE’s have keel cooler piping, missing insulation on hot surfaces. Replace or repair in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 16 June 2021
Resolved
Davit wire rope is damaged. Replace in kind, conducted inspection of all components, and perform weight test to the satisfaction of USCG.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2021
Resolved
The std engine reduction gear to engine block was separating and bolts were loose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 June 2021
Resolved 16 June 2021
Resolution: Bolts were tightened.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2021
Resolved
The std SSDG high pressure fuel line is chaffed (damaged) replace in kind, inspected remaining and properly secure in brackets.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 June 2021
Resolved
The MSD, Engine Room, Eng. Control station have damaged light fixtures. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2021
Resolved
The engine room control station, breaker panel is missing breaker information. Properly identify all breakers.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2021
Resolved
The port side steering room, bilge has loose clamp. Properly install.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 June 2021
Resolved
The engineering control station, has a loose speaker in overhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2021
Resolved
All batteries in engine room need to have maintenance inspection and corrosion cleaned from terminals. Remove all wing nuts and replace with nylock or lock nut to make connections properly tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 June 2021
Resolved
The port and std fuel oil strainers are loose and missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 June 2021
Resolved
The port and starboard MDE’s shafting stuffing boxes were missing locking nuts.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 June 2021
Resolved 16 June 2021
Resolution: Installed locking nuts on MDE stuffing box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2021
Resolved
The port and std MDE’s have damaged supply and return flexible fuel lines (as marked by MI) which need replacement in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 9 August 2021
Resolution: The attending inspector verified the outstanding require was satisfactory this date.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 June 2020
Resolved
Re-install overhead console in pilot house with proper hardware. Locking tabs became loose and are not securing the VHF radio's and vessels horn controls.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2020
Resolved 17 July 2020
Resolution: Received, reviewed, and accepted objective documentation and photos of repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 15 June 2020
Resolved
The rescue boats gas tank was damaged.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 16 July 2020
Resolved 16 July 2020
Resolution: Crew replaced gas tank with new approved tank to the satisfaction of the attending inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 July 2019
Resolved
Make repairs to the fire pump noted as leaking during operational testing this date from pump casing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2019
Resolved 25 July 2019
Resolution: Company made repairs, tested, and office accepted documentation satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2019
Resolved
#1 MDE had wiring chaffing on top of fuel oil piping lines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 25 July 2019
Resolution: Company made repairs and office accepted documentation satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2019
Resolved
#2 MDE turbo piping near exhaust was missing lagging.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2019
Resolved 25 July 2019
Resolution: Company made repairs and office accepted documentation satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2019
Resolved
#1 SSDG turbo oil seal had small leak.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 26 July 2019
Resolution: Company made repairs, tested, and office accepted documentation satisfying the requirement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2019
Resolved
EDG and engine room switch board had breaker unmarked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 26 July 2019
Resolution: Company made repairs and office accepted documentation satisfying the requirement.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 24 July 2019
Resolved
The general alarm back up batteries had excessive corrosion on the terminals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 26 July 2019
Resolution: Company made repairs and office accepted documentation satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2019
Resolved
EDG supply fuel line was cracked and damaged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 26 July 2019
Resolution: Company made repairs, tested, and office accepted documentation satisfying the requirement.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 April 2019
Resolved
Provide proper notifications were made about the loss of SSDG #1 as a result of overspeed indiacated by engineers log (Dated 21Apr19 @ 1550) was sent to Coast Guard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2019
Resolved 24 April 2019
Resolution: Received, reviewed, and accepted documentation from NCDOT satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2019
Resolved
Port and stbd shafting were leaking excessively and were missing lock nuts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2019
Resolved 24 April 2019
Resolution: Received, reviewed, and accepted documentation from NCDOT satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2019
Resolved
Make proper repairs to #1 reduction gear oil leaks at the pump housing and clutch actuator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Received supporting documentation attesting to proper repairs, satisfying the requirement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 April 2019
Resolved
The breaker rating and plaques on the emergency and main switch board are conflicting. Prove correct approved rating.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Received supporting documentation attesting to proper repairs, satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2019
Resolved
Port and Stbd MDE's have loose fuel oil piping brackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2019
Resolved 29 April 2019
Resolution: Received supporting documentation attesting to proper repairs, satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2019
Resolved
Improper made wire connections under console in engine room for the MDE's were identified.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2019
Resolved 5 February 2019
Resolution: Received, reviewed, and accepted e-mail attesting to the corrective item completed per requirement.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 January 2019
Resolved
Main switch board in engine room has wasted and damged wire insulation on wire run into the main panel outboard at the top.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2019
Resolved 5 February 2019
Resolution: Received, reviewed, and accepted e-mail attesting to the corrective item completed per requirement.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 January 2019
Resolved
MSD space has a damaged light cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2019
Resolved 24 April 2019
Resolution: M/I verified satisfactory completion of the outstanding requirement.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 30 January 2019
Resolved
MSD panel has a missing button on the front alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2019
Resolved 24 April 2019
Resolution: M/I verified satisfactory completion of the outstanding requirement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 January 2019
Resolved
MSD space has a damaged flammable locker that is not meeting flame spread as designed, due to corrosion.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2019
Resolved 24 April 2019
Resolution: M/I verified satisfactory completion of the outstanding requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 January 2019
Resolved
Stbd generator keel cooler piping is wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2019
Resolved 5 February 2019
Resolution: Received, reviewed, and accepted e-mail attesting to the corrective item completed per requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2018
Resolved
Adjust P&S shaft packing glands due to excessive leaking.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 October 2018
Resolved 26 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2018
Resolved
Install drip shield IWO STBD aft Battery charger
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 October 2018
Resolved 26 October 2018
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 July 2018
Resolved
First Aid Kit is a DOT approved kit that doesnt meet 46CFR160.041 requirements. Missing meds.
Action required: 705 - Other - as specified
Due 17 August 2018
Resolved 17 August 2018
Resolution: Proper first aid kit provied.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2018
Resolved
Child Life jacket storage boxes behind pilot house need to be properly marked.
Action required: 705 - Other - as specified
Due 17 August 2018
Resolved 17 August 2018
Resolution: All life jacket storage locations properly marked.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 25 October 2017
Resolved
Unable to test EDG low lube oil and overspeed shutdown sensors on the engine. Provide means to prove proper operation of shutdown devices.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 27 March 2018
Resolution: Witnessed testing of the EDG alarms and shutdowns
Engineering › Compressed Air System (control) › Piping
Issued 14 September 2017
Resolved
Submit repair proposal for removing water/moisture from throttle and control system. As per conversation with [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 27 March 2018
Resolution: A moisture separator was installed on the service air line in the engine room.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 13 September 2017
Resolved
STBD MDE control has moisture in the system not allowing the clutch to shift.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 13 September 2017
Resolved 14 September 2017
Resolution: Drained 7 water seperators and all systems test SAT. NCDOT is to submit repair proposal for correction of moisture rating. Drain every four hours and log.
Engineering › Diesel Engine (propulsion-reduction gear) › Air-flex Clutch
Issued 31 May 2017
Resolved
Throttle air control delay over 2 min. Cracked tubing to cluck air PSI. Tubing appears to be to short causing crack.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 31 May 2017
Resolution: Made new air to cluck tube proper length and flare.
Electrical › Electric Generation Source (service) › Generator
Issued 21 October 2016
Resolved
Crankshaft bolt broke and siezed oil pump, requiring a new engine to be installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2016
Resolved 25 October 2016
Resolution: A new engine was installed and ALL test SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 21 October 2016
Resolved
#4 Cyl lifter ticking
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2016
Resolved 21 October 2016
Resolution: #4 cyl lifters replaced and tune up conducted. Engine was tested at sea with SAT results.