MAURY USCG vessel records Sign in
← All vessels

PANTANASSA

PANTANASSA is a 1988 freight ship. The Coast Guard has recorded 19 inspections since 1989, most recently in January 2005, along with 13 deficiencies and 1 operational control.

Records from 1989 to 2005. Most recent: inspection, 18 January 2005.

Built
1988
Last inspected
18 January 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8513182 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
325942
Flag
BAHAMAS, THE
—
Maury page id
psix-325942

Inspections, by type

…with no type recorded14
Years with a record 13 calendar years (1989–2005)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it36264 - Convention (Subpart B), Gross Ton
23015 - Convention (Subpart B), Net Ton
69763 - Dead Weight, Ton
79722 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

18 January 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2276247
12 November 2003 Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1943715
12 November 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1946447
2 April 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1766940
29 January 2003 Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1737197
27 June 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1639789
25 June 2002 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1636031
19 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 727345
4 June 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 172329
25 May 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278385
29 April 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 8013
17 April 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 427682
21 May 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 416207
6 January 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 399063
1 February 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 387518
2 May 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 377693
15 June 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 351368
19 August 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 338770
11 February 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 328542

Deficiency record · 13

Lifesaving › Lifejacket/PFD (General)
Issued 12 November 2003 Resolved
Replace expired lifejacket lights on all crewmember lifejackets (LSA Code) LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2003
Resolution: Lifejacket lights replaced.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 12 November 2003 Resolved
Renew crewmember fire fiighting suits due to wear (FSS Code).
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 January 2005
Resolution: Cleared by ActBalt during PSC exam.
Lifesaving › Inflatable Liferafts
Issued 12 November 2003 Resolved
Properly secure painters on ships life rafts in accordance with manufacturers instructions (LSA Code). LEGACY COMPONENT DESC: Painter
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2003
Resolution: Painters secured properly on ships life rafts in accordance with manufacturers instructions.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 12 November 2003 Resolved
Prove proper operation of galley serving window fire boundary closures (FSS Code) LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 January 2005
Accommodation/Occupational Safety › Occupational Safety
Issued 12 November 2003 Resolved
Replace rotted oxygen and acetylene hoses on fixed and portable cutting unit bottles. LEGACY COMPONENT DESC: Welding/Hot Work
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2003
Resolution: Rotted oxygen and acetylene hoses on fixed and portable cutting unit bottles have been replaced.
Fire Fighting › Means of Escape
Issued 12 November 2003 Resolved
Refill discharged EEBD in engineroom (FSS Code) LEGACY COMPONENT DESC: EEBD
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2003
Resolution: EEBD in engineroom has been recharged.
Fire Fighting › Means of Escape
Issued 12 November 2003 Resolved
Provide spare EEBD (SOLAS reg 13, 3.4.1) LEGACY COMPONENT DESC: EEBD
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2003
Resolution: Total EEBD required for vessel is only 8pcs, vessel has ten.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 January 2003 Resolved
The main engine was missing all three inspection access covers for the F/O injection pump compression springs. LEGACY COMPONENT DESC: Inspection Covers
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2003
Resolved 29 January 2003
Resolution: Replaced before boarding team departed vessel.
Engineering › Lubricating Oil Service System
Issued 29 January 2003 Resolved
The vessel had a rubber hose re-circulating lubricating oil for the stern tube. LEGACY COMPONENT DESC: Stern Tube Arrangement
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 February 2003
Resolved 2 April 2003
Resolution: Received class report from Bureau Veritas satisfying requirement.
Engineering
Issued 29 January 2003 Resolved
There was a fabricated containment drain pan by main engine that was draining directly to bilge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 January 2003
Resolved 29 January 2003
Resolution: Pan and drian line removed before boarding team departed vessel.
Construction/Loadline › Markings
Issued 29 January 2003 Resolved
The Loadlines were not visible with contrasting colors. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2003
Resolved 29 January 2003
Resolution: Crew painted loadline before boarding team departed vessel.
Engineering › Compressed Air System (start air)
Issued 29 January 2003 Resolved
The cooling water supply line to air compressor cooler has a temporary band clamp patch. LEGACY COMPONENT DESC: Air Compressor Cooler
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2003
Resolved 2 April 2003
Resolution: Received class report from Bureau Veritas satisfying requirement.
Documentation
Issued 25 May 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 2000
Resolved 21 June 2002
Resolution: CORRECTED

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.