ISLAND LADY

ISLAND LADY is a 1989 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1989, most recently in February 2026, along with 67 deficiencies and 2 casualty investigations between 2007 and 2008.

Records from 1989 to 2026. Most recent: inspection, 11 February 2026.

Built
1989
Last inspected
11 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI6172
325948
Flag
UNITED STATES
367715980
Maury page id
psix-325948

Inspections, by type

…with no type recorded5
Years with a record 35 calendar years (1989–2026)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.0 ft × 21.0 ft × 6.5 ft
Registered tonnagegross 65 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS OF STUART · STUART, FL, UNITED STATES · built 1989
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 25 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI6172MMSI 367715980 · active · compulsorily equipped · granted 8 January 2026, expires 18 February 2036
WDI3120MMSI 367014880 · expired · compulsorily equipped · granted 22 July 2015, cancelled 23 August 2025
WAH8109MMSI 367014880 · expired · voluntarily equipped · granted 1 February 2005, cancelled 13 June 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 70

11 February 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8303441
6 November 2024 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8020609
8 October 2024 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8010384
23 January 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7855604
16 May 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7689803
20 January 2023 Drydock Exam · Administrative Inspection · In-Service Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7626200
22 December 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7616344
2 December 2022 Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7608479
3 November 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7347136
22 September 2021 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7318311
20 November 2020 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7099250
19 November 2019 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6855914
25 September 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6820471
29 January 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6616515
25 January 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6615187
13 August 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6510454
19 September 2017 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6269943
27 June 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6188730
25 February 2017 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6094667
7 February 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6084527
23 February 2016 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5819827
8 December 2015 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5797345
27 October 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5751574
5 May 2014 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4850666
28 September 2011 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4156171
13 January 2010 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3663189
3 March 2009 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3426327
17 March 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3165923
14 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3166724
18 November 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3104345
10 September 2007 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3054448
24 July 2007 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3005751
16 July 2007 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2996797
23 January 2007 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2859936
16 May 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2650909
6 March 2006 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2597183
13 September 2005 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2497883
1 February 2005 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2283890
30 March 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2033787
16 September 2003 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1905236
11 February 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1742753
26 February 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1489194
26 September 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1403469
13 February 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1423521
15 February 2000 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1440250
29 September 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1393242
27 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781352
3 March 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1369054
6 October 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 801166
24 February 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 780256
12 September 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1402515
18 February 1997 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1101932
27 February 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885746
24 October 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877902
5 June 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 875821
15 March 1995 COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 854862
2 December 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181934
1 December 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181933
21 April 1994 MARPOL Annex V Examination · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 869851
23 March 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 673165
22 March 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1412618
28 October 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1144519
4 February 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1137905
7 December 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 828549
27 October 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 950891
10 December 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1252894
24 April 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1224242
7 December 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 909237
29 May 1990 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 916632
7 December 1989 Inclining Experiment · Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 911081

Deficiency record · 67

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 6 November 2024 Resolved
Each individual referred to in paragraph (a) of this section must hold an MMC that serves as identification, with an appropriate endorsement for the position in which the seaman serves, and the MMC, along with a valid medical certificate, must be presented to the master of the vessel at the time of employment or before signing Articles of Agreement. Master of vessel missing Medical Certificate. MI verified Master of vessel holds valid Medical Certificate. Provide copy of medical certificate as required. 46 CFR 14.501(d) - Not available in MISLE
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 14 November 2024
Resolution: Provided proof of valid medical certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. No means of separating child and adult life jackets observed in pilot house.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 22 November 2024
Resolution: Properly separated child and adult life jackets.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 6 November 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions for heavy weather not posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 14 November 2024
Resolution: Emergency instructions for heavy weather posted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 November 2024 Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Watertight hatches on exterior of vessel not labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 14 November 2024
Resolution: Hatches properly labeled
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 November 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Emergency fuel shut off valves missing direction of operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 14 November 2024
Resolution: Fuel valves properly marked
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 6 November 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Emergency exit not labeled on the main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 19 November 2024
Resolution: Emergency Hatch properly marked
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 January 2024 Resolved
All vessels required to be provided with a power driven pump shall also be provided with a fire main system including fire main, hydrants, hoses and nozzles. a) wrd fire hose is not operational and requires replacement. b) piping or ire main leaking from multiple locations; renew. 46 CFR 181.15-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2024
Resolution: Piping was renewed and the fire hose was replaced in kind. No leaks evident during operational testing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 January 2019 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. The vessel was involved in an collision which damaged the bulwarks above the water line on the aft deck.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2019
Resolved 26 January 2019
Resolution: There was no structural damage to vessel at the timem of inspection. The vessel is fit for its routes and conditions.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018 Resolved
AIS data showing zero length or beam/zero draft due to missing length of vessel points from AIS ANT location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 January 2019
Resolution: Owner has properly programmed AIS to reflect the vessel within the AIS reporting system.
Construction/Loadline › Hull › Side Shell
Issued 19 September 2017 Resolved
Provide repair proposal for soft/rotted wood on the transom.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 29 September 2017
Resolution: Vessel provided repair proposal.
Engineering › Bilge Water Management System › Valve
Issued 19 September 2017 Resolved
Replace both overboard discharge valves in the lazzerette, port and starboard side.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 29 September 2017
Resolution: Vessel replace both overboard discharge valves in the lazzerette, port and starboard side.
Construction/Loadline › Structures › Superstructure
Issued 25 February 2017 Resolved
Vessel mast allided with bridge causing it to separate from deck mounting. Vessel must provide repair proposal and renew as original damaged mast and all affected navigation/safety equipment.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2017
Resolution: Mast properly reinstalled. All components on mast were statisfactorily tested.
Construction/Loadline › Hull › Hull Plating
Issued 27 October 2015 Resolved
Provide repair proposal for soft/rotted areas of the hull. -Port side tank void -Starboard forpeak -starboard storage void
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2015
Resolved 5 November 2015
Resolution: All repairs completed.
Stability › Watertight Integrity › General
Issued 28 September 2011 Resolved
Make main deck windows on port and starboard sides available for inspection upon installation.
Action required: 705 - Other - as specified
Resolved 7 October 2011
Construction/Loadline › Hull › Bottom Plating
Issued 28 September 2011 Resolved
Crop and renew rotted wood in starboard side engine room IWO the chine. Repair as original.
Action required: 705 - Other - as specified
Resolved 21 October 2011
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 13 January 2010 Resolved
Handle for emergency escape hatch in #2 compartment missing.
Due 4 February 2010
Resolved 26 January 2010
Resolution: Handle replaced and tested satisfactory.
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 January 2010 Resolved
Hot water heater is loose and needs to be properly secured.
Due 4 February 2010
Resolved 26 January 2010
Resolution: Hot water heater now fastened and secure.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 13 January 2010 Resolved
Heat sensor in engine room for fixed fire suppression system need to be properly secured.
Due 4 February 2010
Resolved 26 January 2010
Resolution: Port and Stbd side heat detectors properly secured.
Fire Fighting › Fire Pumps › Arrangement
Issued 13 January 2010 Resolved
Raw water pump in #3 compartment not mounted properly.
Due 4 February 2010
Resolved 26 January 2010
Resolution: Raw water pump properly secured to deck.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 January 2010 Resolved
Top of frame in #3 compartment from fwd bulkhead aft #2 frame is cut away and has to be scarfed.
Due 4 February 2010
Resolved 26 January 2010
Communications › Alarms/Indicators › Speed/Distance Indicator
Issued 3 March 2009 Resolved
Repair or replace RPM gauge on bridge for port MDE.
Action required: 705 - Other - as specified
Due 15 March 2009
Resolved 12 March 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 3 March 2009 Resolved
Provide cage for glass globe in forward compartment or install plastic globe.
Action required: 705 - Other - as specified
Due 15 March 2009
Resolved 12 March 2009
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 March 2009 Resolved
Provide means of indicating when the MSD tank is more than 3/4 full by volume IAW 33 CFR 159.83.
Action required: 705 - Other - as specified
Due 15 March 2009
Resolved 12 March 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 March 2008 Resolved
Replace rotted grab line on life ring buoy, upper deck stbd side.
Due 24 March 2008
Resolved 23 March 2008
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 17 March 2008 Resolved
Repair or replace broken needle on rudder angle indicator.
Due 24 March 2008
Resolved 23 March 2008
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 March 2008 Resolved
Properly secure oven in galley area.
Due 24 March 2008
Resolved 23 March 2008
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 September 2007 Resolved
Permanently mark draft / loading marks on hull IAW stability letter.
Action required: 705 - Other - as specified
Resolved 14 September 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 10 September 2007 Resolved
Renew / replace two hull valves.
Action required: 705 - Other - as specified
Resolved 14 September 2007
Construction/Loadline › Hull › Side Shell
Issued 10 September 2007 Resolved
Make proper repairs to exhust hull penetration on center line engine.
Action required: 705 - Other - as specified
Resolved 14 September 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 March 2006 Resolved
Provide Aspirin in First Aid Kit
Due 15 March 2006
Resolved 21 March 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 6 March 2006 Resolved
Provide missing B-II portable fire extinguisher onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 6 March 2006 Resolved
Permanently wire AC ventillation fan in aft compartment.
Due 15 March 2006
Resolved 21 March 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 6 March 2006 Resolved
Properly remove 12 V ventillation fan no longer in service in aft compartment
Due 15 March 2006
Resolved 21 March 2006
Fire Fighting › Fire Pumps › Pressure
Issued 6 March 2006 Resolved
Repair/Replace pressure gauge on fire pump.
Due 15 March 2006
Resolved 21 March 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 March 2006 Resolved
Provide a guard for moving belt on engine
Due 15 March 2006
Resolved 21 March 2006
Stability › Watertight Integrity › General
Issued 1 February 2005 Resolved
Repair hole found at watertight bulkhead frame #17.
Action required: 705 - Other - as specified
Due 1 February 2005
Resolved 1 February 2005
Resolution: Observed proper repair of WTBH.
Electrical › Electrical Distribution System (service) › Cable
Issued 1 February 2005 Resolved
Found all overhead wire/cable below bulkhead deck improperly installed with plastic wire ties.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2005
Resolved 7 March 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2005 Resolved
Dead ended wires found at WTBH #17 inside Liquor Storage compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2005
Resolved 1 February 2005
Resolution: Dead wires properly terminated with an electrical box.
Construction/Loadline › Markings
Issued 16 September 2003 Resolved
Provide hull markings in accordance with 46 CFR 185.602. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 16 October 2003
Resolved 14 October 2003
Engineering › Bilge Water Management System
Issued 15 September 2003 Resolved
Prove operation of bilge system by demonstrating suction from all compartments.
Due 16 October 2003
Resolved 14 October 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 11 February 2003 Resolved
Ensure CO2 piping installation is I.A.W. 46 CFR 181.410(d)(2)
Condition: Design Flaw
Due 15 February 2003
Resolved 28 February 2003
Engineering › Bilge Water Management System › Piping
Issued 11 February 2003 Resolved
Replace deteriorated bilge piping for E/R suction
Due 15 February 2003
Resolved 28 February 2003
Lifesaving › Rescue Boat
Issued 26 February 2002 Resolved
Vessel does not have required rescue boat and does not have a satisfactory equivalent arrangement such as a rescue platform as outlined in CSED MEMO 01-01. LEGACY COMPONENT DESC: Alternate retrieval method
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 19 March 2003
Navigation
Issued 13 February 2001 Resolved
Install starboard rudder stop.
Condition: Unknown
Due 1 March 2001
Resolved 2 March 2001
Deck/Cargo
Issued 13 February 2001 Resolved
Properly identify escape hatch in the main lounge area.
Condition: Unknown
Due 1 March 2001
Resolved 2 March 2001
Unknown
Issued 13 February 2001 Resolved
Repair or replace fuel system return fitting leaks.
Condition: Unknown
Due 26 February 2001
Resolved 2 March 2001
Documentation
Issued 15 March 1995 Resolved
Provide a valid FCC Radio Safety Certificate. Vessel is restricted to not more than 1000' from shore until completed.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Navigation
Issued 15 March 1995 Resolved
Provide up-to-date charts for Miami Harbor and Intracoastal waterway.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Electrical
Issued 15 March 1995 Resolved
Remove wire nuts underneath steering station.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Lifesaving
Issued 15 March 1995 Resolved
Provide a separate lanyard for the ring buoy waterlight.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Lifesaving
Issued 15 March 1995 Resolved
Properly label life jacket stowage on the upper deck.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Electrical
Issued 15 March 1995 Resolved
Repair 12 volt emergency light in the fuel tank space.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Construction/Loadline
Issued 15 March 1995 Resolved
Repair leak in port main engine exhaust penetration in the transom.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Fire Fighting
Issued 15 March 1995 Resolved
Replace inoperable fire pump pressure gauge.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Lifesaving
Issued 1 December 1994 Resolved
Renew all lines & retroflective tape on all buoyant apparatus.
Condition: Unknown
Due 2 December 1994
Resolved 5 December 1994
Construction/Loadline
Issued 1 December 1994 Resolved
Prove operation of E/R bilge float switch alarm.
Condition: Unknown
Due 2 December 1994
Resolved 5 December 1994
Fire Fighting
Issued 1 December 1994 Resolved
Provide evidence of fire extinguisher servicing.
Condition: Unknown
Due 2 December 1994
Resolved 5 December 1994
Lifesaving
Issued 22 March 1994 Resolved
Renew two (2) ring buoys._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 1994
Resolved 23 March 1994
Construction/Loadline
Issued 22 March 1994 Resolved
Lable the location of the forepeak bilge isolation valve on the bulkhead above the valve._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 1994
Resolved 23 March 1994
Construction/Loadline
Issued 22 March 1994 Resolved
Renew or repair the check valve in the bilge line for the crew room compartment bilge.
Condition: Unknown
Due 22 March 1994
Resolved 23 March 1994
Construction/Loadline
Issued 22 March 1994 Resolved
Correctly lable the bilge manifold valves._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 1994
Resolved 23 March 1994
Electrical
Issued 22 March 1994 Resolved
Provide one flashlight (emergency lighting) for each required crew member._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 1994
Resolved 23 March 1994
Navigation
Issued 22 March 1994 Resolved
Provide on board vessel, U.S. Chart number 11468._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 1994
Resolved 23 March 1994
Documentation
Issued 22 March 1994 Resolved
Maximum number of persons allowed on the vessel's upper deck, including crew, is limited to 60 persons._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 7 December 1992 Resolved
RESTENCIL MAIN DECK LIFEJACKET LOCKERS.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Lifesaving
Issued 7 December 1992 Resolved
RESTENCIL 4 BUOYANT APPARATIS.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Lifesaving
Issued 7 December 1989 Resolved
PROVIDE A SUITABLE RESCUE BOAT.
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989

Casualty record · 2

18 November 2007Routine · role: Involved in a Marine Casualty · activity 3104345
14 March 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3166724
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.