XPLORER is a 1989 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1990, most recently in March 2026, along with 108 deficiencies.

Records from 1990 to 2026. Most recent: inspection, 31 March 2026.

Built
1989
Last inspected
31 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

KUS94499
326187
Flag
UNITED STATES
367436250
Maury page id
psix-326187

Inspections, by type

…with no type recorded2
Years with a record 29 calendar years (1990–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 4.5 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS INC · TARPON SPRINGS, FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portSOUTH PADRE ISLAND, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 June 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF3129MMSI 367436250 · active · voluntarily equipped · granted 1 November 2019, expires 12 January 2030
WCZ9661MMSI not assigned · expired · compulsorily equipped · granted 31 July 2000, cancelled 2 October 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 54

31 March 2026 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8334050
1 April 2025 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8103346
25 July 2024 Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7938925
5 March 2024 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7863273
30 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7853643
28 June 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7715146
5 July 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7746905
5 April 2022 Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7424964
21 July 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7263720
29 April 2020 COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6945747
24 January 2020 Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6900540
5 August 2019 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6775551
15 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6416900
26 March 2018 Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6381201
21 August 2017 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6247703
10 August 2017 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6237292
1 August 2017 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6227666
11 August 2016 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5969439
12 August 2014 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4952915
5 June 2014 In-Service Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4908754
5 March 2014 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4810651
4 May 2012 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4302156
15 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4117450
26 January 2010 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3671006
26 January 2010 Initial Certification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3715300
5 October 2006 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2794388
27 February 2006 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2591267
18 November 2004 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2244358
23 September 2004 Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2182158
13 September 2003 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1924981
5 September 2003 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1900698
20 August 2002 Deficiency Check · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1663881
7 September 2001 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1428084
19 October 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 823168
25 September 2000 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1054527
1 September 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 822911
18 August 2000 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1408587
2 June 2000 COI Inspection · Examination of Repairs
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 819513
1 September 1999 COI Inspection · Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1420217
5 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117549
16 May 1995 Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1136578
26 April 1995 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1161288
26 April 1995 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1173146
16 May 1994 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1168301
14 July 1993 Deficiency Check
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1156223
25 June 1993 Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 847295
11 June 1992 Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 958044
3 February 1992 Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1258075
23 August 1991 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1243658
20 May 1991 Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 916718
16 May 1991 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 924957
15 May 1991 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 903057
22 May 1990 Initial Certification
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 903799
8 May 1990 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1214597

Deficiency record · 108

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI found 19 life jackets that had DOT tape and not SOLAS tape. Replace with appropriate tape. *No night time operations until cleared.
Action required: 705 - Other - as specified
Resolved 9 May 2025
Resolution: Vessel rep supplied satisfactory evidence of new solas tape. MI reviewed and no defs identified.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 April 2025 Resolved
An EAP training program must be conducted for the employer's crew members and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Vessel POC was not able to supply proof of supervisory training. Complete and show proof.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 15 May 2025
Resolution: Vessel rep sent satisfactory proof of completed course. MI reviewed with no defs identified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2024 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load under such requirements without exceeding its designed limitations. Port outboard engine overheated during inspection. 46 CFR 182.05-1 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2024
Resolution: MI conducted an in-service inspection. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine inspector. Battery conductors found corroded. 46 CFR 183.01-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2024
Resolution: MI inspected new battery terminals. All sat
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 July 2024 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. MI found two fire extinguishers waisted from corrosion. 46 CFR 181.500 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 July 2024
Resolution: MI inspoected recently serviced fire extinguishers. All sat
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 25 July 2024 Resolved
At least once every three months the emergency drills shall be conducted. No drill logs kept onboard. 46 CFR 185.420 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2024
Resolution: MI observed MOB drill log. all sat
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 July 2024 Resolved
At each inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. The Master and crew did not understand their responsibilities for conducting the man overboard drill. 46 CFR 176.808 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2024
Resolution: MI observed satifactory MOB drill.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 July 2024 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter. The vessels ring buoy was found with an un-serviceable grab line. 46 CFR 180.70 (b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 July 2024
Resolution: MI inspected new life ring grab line. all sat
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 June 2023 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. MI found COI not posted. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 30 June 2023
Resolution: Vessel posted COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 June 2023 Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. MI found the stability letter not posted. 46 CFR 176.306
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 30 June 2023
Resolution: Vessel posted Stability letter.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 June 2023 Resolved
At least once every three months the emergency drills shall be conducted. No drill logs kept for the previous six months. 46 CFR 185.420 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2023
Resolution: MI observed drills.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 June 2023 Resolved
At the operating station emergency instructions must be mounted. No emergency instructions where posted. 46 CFR 185.510 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 30 June 2023
Resolution: Vessel posted emergency instructions
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 June 2023 Resolved
A documented vessel must have on board the original Certificate of Documentation (COD) currently in effect for that vessel. Vessel had onboard an expired COD 46 CFR 67.313 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2023
Resolution: Vessel COD was approved by USCG.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 June 2023 Resolved
Up-to-date charts and nautical publications of large enough scale to make safe navigation possible as appropriate for the intended voyage, must be carried onboard vessels. MI found no local charts for intended voyages. 46 CFR 184.420 (a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2023
Resolved 7 July 2023
Resolution: Vessel procured up tp date charts.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 28 June 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One portable light found onboard. 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 30 June 2023
Resolution: Vessel installed second portable light.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 June 2023 Resolved
A vessel must carry a first-aid kit approved under approval series 46 CFR 160.041. Expired and missing components found in kit. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 7 July 2023
Resolution: Vessel procured missing and expired components.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI found six unserviceable life jackets onboard. Reduce passenger count to 45. 46 CFR 180.71 (a)
Action required: 705 - Other - as specified
Resolved 30 June 2023
Resolution: Vessel replaced six life jackets. COI posted pax amount restored.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2023 Resolved
Each life jacket must be marked with Type I retroreflective material. Retroreflective material on life jackets was unserviceable. 46 CFR 185.604 (h) IMO RESOLUTION A.658(16) (5)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 July 2023
Resolution: Retro Reflective material was replaced and inspected by MI.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 June 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. MI found one type of life jacket onboard without proper donning instructions posted. 46 CFR 185.516 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 30 June 2023
Resolution: Vessel posted donning instructions for all types of life jackets.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 June 2023 Resolved
Deck rails shall consist of evenly spaced courses and the spacing between courses shall not be greater than 12 inches. Course spacing was found onboard to be greater than 12 inches. 46 CFR 177.35-1 (b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2023
Resolution: Vessel installed netting on deck rails.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 June 2023 Resolved
The installation and location of the portable fire extinguisher must be to the satisfaction of the [name withheld] extinguisher not found in bracket. Rectify within 7 days. 46 CFR 181.520
Action required: 705 - Other - as specified
Resolved 30 June 2023
Resolution: vessel installed bracket.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 June 2023 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. MI found a portable fire extinguisher located in a cabinet on the main deck not labeled as such. 46 CFR 181.520.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2023
Resolution: vessel labeled fire extinguisher location.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2023 Resolved
The discharge ends of the vent pipes shall be fitted with removable flame screens or flame arrestor’s. Fuel vent flame screen was missing. 46 CFR 182.15-35
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2023
Resolution: Vessel installed new flame screen.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 June 2023 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. High level alarms where mixing from 08 spaces. 46 CFR 185.530 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 18 July 2023
Resolution: POC installed bilge high level alarms and tested in the presence of the MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 June 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine inspector. Start battery negative conductor was found damaged. 46 CFR 183.01-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2023
Resolution: Vessel installed new battery cable.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 28 June 2023 Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Vessels crew and captain where not enrolled in the company’s DAPI program. Vessel is to use only current members of the companies DAPI program. 46 CFR 16.210 (a)
Action required: 705 - Other - as specified
Resolved 30 June 2023
Resolution: Company received proof of DAPI conformance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2023 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. MI found two 80-B:C fire extinguisher waisted from corrosion. 46 CFR 181.500 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2023
Resolution: Vessel installed two inspected fire extinguishers.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 June 2023 Resolved
The intent of this part is to ensure that the scantlings, materials, fastenings, workmanship in arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. MI found the lazarette hatch unserviceable. 46 CFR 177.01-5 14 days
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 July 2023
Resolution: POC installed new hatch. MI inspected. All sat.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 21 August 2017 Resolved
Replace missing deck hatch cover on port side, aft deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 1 September 2017
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 August 2017 Resolved
Vessel restricted to no more than 46 persons on board (44 passangers &2 crew) until 03 adult lifejackets are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 1 August 2017
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 August 2017 Resolved
Vessel must provide 01 child life jacket to meet 10% of total passenger count of total passengers. Child sized life jacket is required for every passenger under 90lbs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 10 August 2017
Resolution: Verified total required number of child life jackets are onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 1 August 2017 Resolved
Prior to the operation, vessel must carry 01 B1 fire extinguisher as required by the COI.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 1 August 2017
Resolved 1 August 2017
Resolution: Vessel owner provided vessel with needed extinguisher.
Engineering › Fuel Oil Service System › Valve, Control
Issued 1 August 2017 Resolved
Fuel shut off valves must be installed in the fuel supply lines on the tank side of the system.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 10 August 2017
Resolution: Verified installation of required fuel shut off valves in fuel supply lines to both port and starboard engines.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 1 August 2017 Resolved
Replace fuel tank vent line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 21 August 2017
Resolution: Verified installation of new fuel tank vent flexible hose.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 August 2014 Resolved
Renew worn retro on all lifejackets. 46CFR180.75
Due 21 August 2014
Resolved 18 March 2015
Resolution: Renewed worn retro on life jackets.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 August 2014 Resolved
Provide Coast Guard approved first aid kit. 46CFR 160.041
Due 21 August 2014
Resolved 18 March 2015
Resolution: Provided Coast Guard approved first aid kit.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 August 2014 Resolved
Renew broken battery cover. 46CFR183.350
Due 21 August 2014
Resolved 18 March 2015
Resolution: Renewed broken battery cover.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 August 2011 Resolved
Renew stern navigation light. 46 CFR 183.420. Complete prior to night time operations.
Action required: 705 - Other - as specified
Resolved 15 August 2012
Resolution: Verified corrected
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 15 August 2011 Resolved
Post emergenyc broadcast placard. 46 CFR 184.506
Due 15 September 2011
Resolved 15 August 2012
Resolution: Verified corrected.
Engineering › Fuel Oil Service System › Hose
Issued 15 August 2011 Resolved
Renew cracked fuel hoses. 46 CFR 182.455
Due 15 September 2011
Resolved 15 August 2012
Resolution: Verified corrected.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 August 2011 Resolved
Renew grab line becketed around ring buoy. 46 CFR 180.070
Due 15 September 2011
Resolved 15 August 2012
Resolution: Verified corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 15 August 2011 Resolved
Renew corroded B-II portable fire extinguisher. 46 CFR 181.500
Due 15 September 2011
Resolved 15 August 2012
Resolution: Verified corrected.
Stability › Incline Test › General
Issued 26 January 2010 Resolved
Vessel to conduct a stability test or incline test prior to operation of the vessel.
Action required: 705 - Other - as specified
Resolved 6 May 2010
Resolution: Item completed.
Construction/Loadline › Hull › Hull Plating
Issued 26 January 2010 Resolved
Vessel to make transom available for inspection, also vessel to repair puncture on transom in way of mounts for the outboard engine prior to carrying passengers for hire.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 April 2010
Resolution: Item corrected.
Documentation › Certificates/Documents › Stability Letter
Issued 26 January 2010 Resolved
Provide stability letter as well as plans and drawings of the vessel indicating all changes made since purchase.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2010
Resolution: Item completed.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 26 January 2010 Resolved
Install fuel hoses that meet SAE J-1942 Standard on all flexible fuel hose installations longer than 30 inches.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2010
Resolution: Item corrected.
Engineering › Bilge Water Management System › Valve
Issued 26 January 2010 Resolved
Install positive control valve on all electric submersible bilge pump lines at the overboard discharge.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2010
Resolution: Item corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 January 2010 Resolved
Remove all dead ended wires in port void 2 and 3.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2010
Resolution: Item corrected.
Engineering › Bilge Water Management System › Pump
Issued 26 January 2010 Resolved
Install bilge pump on port and starboard aft compartment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2010
Resolution: Item corrected.
Construction/Loadline › Structures › Deck Plating
Issued 26 January 2010 Resolved
Secure forward portside seating to the deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2010
Resolution: Item corrected.
Lifesaving › Hand Flares › Storage
Issued 26 January 2010 Resolved
Label emergency distress signal container.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 April 2010
Resolution: Item corrected
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 January 2010 Resolved
Install compass light prior to carrying passengers at night.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 April 2010
Resolution: Item corrected.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 26 January 2010 Resolved
Install positive control valve and lock at port and starboard sewage discharge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 April 2010
Resolution: item corrected.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 January 2010 Resolved
Ensure all crew members are enrolled in drug testing program.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2010
Resolution: item corrected
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 January 2010 Resolved
Provide Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 April 2010
Resolution: Item corrected.
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 January 2010 Resolved
Provide US Coast Pilot
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 April 2010
Resolution: Item corrected.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 26 January 2010 Resolved
Ensure batteries in pilot station are protected against shifting and are mounted inside trays constructed of material resistant to the electrolyte.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 April 2010
Resolution: Item corrected.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 January 2010 Resolved
Conduct man overboard drill to the satisfaction of the CG marine inspector. Provide means such as a rescue platform or Jacob's Ladder for man overboard situations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2010
Resolution: Item corrected.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 26 January 2010 Resolved
Vessel operator to have marine radio operator permit prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 April 2010
Resolution: Item corrected.
Stability › Incline Test › General
Issued 26 January 2010 Resolved
Vessel to provide proper stability letter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2010
Resolution: Stability exam conducted (act# 3735135)
Stability › Intact Stability (when using lifting gear) › General
Issued 5 October 2006 Resolved
Vessel's original stability letter was issued based on simplified stability test for a mono hull vessel. Vessel is catamaran. Vessel needs additional evaluation before returning to service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2010
Resolution: Conducted SST.
Construction/Loadline › Hull › Bracket
Issued 27 February 2006 Resolved
Make railing in accordance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Resolved 26 January 2010
Resolution: Item corrected.
Construction/Loadline › Hull › Side Shell
Issued 27 February 2006 Resolved
Address stern (stbd side) area of delamination.
Action required: 705 - Other - as specified
Resolved 26 January 2010
Resolution: Item corrected.
Construction/Loadline › Hull › Transverse Frame
Issued 27 February 2006 Resolved
Crop and repair to good wood the stbd side midhship area adjacent to the control station: hull access area support beam.
Action required: 705 - Other - as specified
Resolved 26 January 2010
Resolution: Item corrected.
Construction/Loadline › Structures › Deck Plating
Issued 27 February 2006 Resolved
Crop and renew to good wood the port side plywood deck area and after transverse bulkhead (plywood).
Action required: 705 - Other - as specified
Resolved 26 January 2010
Resolution: Item corrected.
Construction/Loadline › Hull › Transverse Frame
Issued 27 February 2006 Resolved
Crop and renew the following area: stbd side fwd of the female head, hull access deck support beams and transverse bulkhead.
Action required: 705 - Other - as specified
Resolved 26 January 2010
Resolution: Item corrected.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 November 2004 Resolved
Obtain 6 child PFDs and 2 additional adult PFDs for a total of 51 Adult and 6 Child PFDs. Vessel is limited to 47 adult passengers and 0 children until corrected.
Action required: 705 - Other - as specified
Due 25 November 2004
Resolved 16 December 2004
Resolution: Operator purchased 6 new child PFDs and found missing adult PFDs. All were on-board for 12/16/2004 def. check.
Communications › Radio Communications › EPIRB
Issued 18 November 2004 Resolved
EPIRB was strapped onto a pole with bunge chord. Properly mount EPIRB brackett.
Condition: Improper Installation
Due 15 December 2004
Resolved 16 December 2004
Resolution: Operator properly mounted EPIRB brackett with screw & washer through back cover.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 November 2004 Resolved
Properly log training, drills, lifesaving and firefighting tests and inspections.
Due 15 December 2004
Resolved 16 December 2004
Resolution: Captain created a logbook for drills, tests, training and inspections.
Personnel › Training › First Aid/CPR
Issued 18 November 2004 Resolved
Attend CPR/1st aid refresher training
Due 15 December 2004
Resolved 16 December 2004
Resolution: Captain attended CPR & 1st Aid training Dec 2004. Showed current cards.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 November 2004 Resolved
Place tide table onboard vessel.
Due 15 December 2004
Resolved 16 December 2004
Resolution: Local tide table was placed on-board.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 18 November 2004 Resolved
Place PFD donning instructions near PFD locations. Extended due date until 01/17/2005 in order for operator to obtain the donning instructions from the PFD company.
Due 17 January 2005
Resolved 29 April 2010
Resolution: Vessel went out of service and came back in, PFD instructions posted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2004 Resolved
Properly terminate electrical wiring, various locations throughout the vessel.
Due 23 September 2004
Resolved 23 September 2004
Resolution: Open end wires were terminated with insulated caps/wire nuts.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2004 Resolved
Replace un-approved wire connectors wit approved type.
Due 23 September 2004
Resolved 23 September 2004
Resolution: Crimp connectors were replaced with wire nuts.
Construction/Loadline › Hull › Bracket
Issued 23 August 2004 Resolved
Repair stress fractures on transom at pontoon junction.
Due 23 September 2004
Resolved 23 September 2004
Resolution: Areas were featherd down to the wood core and re-glassed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 23 August 2004 Resolved
Fill gaps around wiring at wire run in collision bulkhead with approved material.
Due 23 October 2004
Resolved 16 December 2004
Stability › Intact Righting Energy › General
Issued 23 August 2004 Resolved
Refasten port sewage tank.
Due 23 September 2004
Resolved 23 September 2004
Resolution: Sewage tank was re-fastened.
Documentation › Certificates/Documents
Issued 5 September 2003 Resolved
2nd annual inspection was not conducted making COI invalid. Also the Operator could not locate the COI. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2003
Resolution: Completed COI inspection (issue) .
Documentation › Logs/Records › Drug Test Records
Issued 5 September 2003 Resolved
No documentation could be provided by the company showing that the crew was enrolled in a drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2003
Resolution: Company provided documentation of enrollment in a drug testing program.
Lifesaving › Buoyant Apparatus
Issued 5 September 2003 Resolved
Service or renew life floats (retro-tape, grab lines, ears, weaklinks, coating)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2003
Resolution: Route ammended from coastwise to L, B & S.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 September 2003 Resolved
Conduct drills and training for man overboard, abandon ship and fire and record the date and description.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2003
Communications › Radio Communications › EPIRB
Issued 4 September 2003 Resolved
Mount EPIRB in a float-free location, replace the hydrostatic release and log EPIRB tests.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 September 2003 Resolved
1st aid kid was missing many items and many of the remaining items were weathered and expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2003
Resolution: A new 1st aid kit was placed on board.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 4 September 2003 Resolved
2 Fire extinguisher brackets were wasted to the point that hand tools had to be used to open them. 1 fire extinguisher was wasted on the bottom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2003
Resolution: Fire extinguishers and brackets were replaced.
Communications › Visual Communication
Issued 4 September 2003 Resolved
No marking for emergency fuel cut-offs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2003
Construction/Loadline › Hull
Issued 3 September 2002 Resolved
Re-gel/coat exposed fiberglass on port and starboard forward corners.
Due 3 October 2002
Resolved 9 October 2002
Construction/Loadline › Hull
Issued 3 September 2002 Resolved
Make permanent repairs to the two areas between port and starboard pontoons in way of bow.
Due 3 October 2002
Resolved 9 October 2002
Construction/Loadline › Penetrations
Issued 3 September 2002 Resolved
Replace overboard discharge fitting on port side.
Due 3 October 2002
Resolved 9 October 2002
Resolution: Metal discharge fitting replaced with plastic.
Construction/Loadline › Structures
Issued 3 September 2002 Resolved
Repair/reseal base of forward bulkhead on #2 port and starboard voids.
Due 3 October 2002
Resolved 9 October 2002
Construction/Loadline › Structures
Issued 3 September 2002 Resolved
Repair transverse deck beam in forward #1 starboard void.
Due 3 October 2002
Resolved 9 October 2002
Construction/Loadline › Structures
Issued 3 September 2002 Resolved
Fumigate pontoons to address carpenter ant infestation.
Due 3 October 2002
Resolved 9 October 2002
Construction/Loadline › Structures
Issued 3 September 2002 Resolved
Escavate/replace 2 in. by 8 in. hatch cover support damaged by carpenter ants in #1 starboard void. LEGACY COMPONENT DESC: Scuttle
Due 3 October 2002
Resolved 9 October 2002
Construction/Loadline › Hull
Issued 3 September 2002 Resolved
Repair delamination under port and starboard bits on forward corners of the bow.
Due 3 October 2002
Resolved 9 October 2002
Construction/Loadline › Hull
Issued 3 September 2002 Resolved
Grind, examine, and repair fiberglass at fractures in transom between port and starboard pontoons. Provide condition report to verify structural integrity in these areas.
Due 3 October 2002
Resolved 9 October 2002
Engineering
Issued 7 September 2001 Resolved
INSTALL PERMANENT BRACKET TIE DOWN SYSTEM FOR FUEL TANKS.
Condition: Unknown
Due 20 October 2001
Resolved 7 September 2001
Lifesaving
Issued 18 August 2000 Resolved
Vessel is restricted to carrying 32 persons on board, due to remaining PFDSfailed inspection. When new and additional properly equipped PFDs are on board. Capacity of person can be increased to requested amount.
Condition: Unknown
Due 18 August 2000
Resolved 18 August 2000
Construction/Loadline
Issued 18 August 2000 Resolved
Install a bilge alarm in accordance with 46 CFR 182.530
Condition: Unknown
Due 18 August 2000
Resolved 18 August 2000
Unknown
Issued 18 August 2000 Resolved
Provide on board a garbage placard.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Unknown
Issued 18 August 2000 Resolved
Provide on board a garbage log.
Condition: Unknown
Due 18 August 2000
Resolved 18 August 2000
Lifesaving
Issued 18 August 2000 Resolved
Provide EPIRB. Vessel is restricted to less than three miles seaward from the demarkation line, until EPRIB is on board.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Documentation
Issued 25 June 1993 Resolved
MARK VESSEL'S NAME ON PORT AND STARBOARD BOW (CATAMARAN) IN ACCORDANCE WITH46 CFR PART 67.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Documentation
Issued 25 June 1993 Resolved
PROVIDE VESSEL'S STABILITY LETTER AND POST ON BOARD IN ACCORDANCE WITH 46 CFR 185.12-1 AND 46 CFR 170.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Documentation
Issued 25 June 1993 Resolved
PROVIDE SATISFACTORY DURG TESTING PROGRAM AS REQUIRED IN ACCORDANCE WITH 46CFR PART 16.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Fire Fighting
Issued 23 August 1991 Resolved
PRIOR TO OPERATION IN FERRY SERVICE OR CARRYING MORE THAN 49 PASSENGERS PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER ONBOARD THE VESSEL.
Condition: Unknown
Due 23 August 1991
Resolved 9 January 1992
Engineering
Issued 16 May 1991 Resolved
PROVIDE FUEL SHUTOFF VALVES AT THE TANK.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Navigation
Issued 16 May 1991 Resolved
PROVIDE ANCHOR BALL DAYSHAPE.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Documentation
Issued 16 May 1991 Resolved
PROVIDE DRUG TESTING PROGRAM MEETING 46 CFR 16 WITHIN 30 DAYS. MAIL COPY TO OCMI.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Engineering
Issued 16 May 1991 Resolved
PROVIDE PROPER HOLD DOWNS FOR STBD FUEL TANK.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.