Records from 1989 to 1993. Most recent: inspection, 20 December 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 63
20 December 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 685227
6 December 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 103934
15 October 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1148126
6 October 1993
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1469407
30 June 1993
MARPOL Annex II Examination · MARPOL Annex V Examination · Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1151468
9 June 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 685228
8 April 1993
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1144473
2 April 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 357364
2 December 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 685229
28 November 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 77150
19 November 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 354842
19 November 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1366762
6 November 1992
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 959080
29 September 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 461060
29 September 1992
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1436709
29 June 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 351668
29 June 1992
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1261422
13 May 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 350754
2 April 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1271038
31 March 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 509206
31 March 1992
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 951527
5 December 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 689008
5 December 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 949237
2 December 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 347531
3 September 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 689007
11 June 1991
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1005400
12 May 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1243022
18 April 1991
Certificate of Compliance · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 914166
13 March 1991
Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232389
20 December 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223095
14 December 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1239340
7 December 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1230860
28 November 1990
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1228810
13 September 1990
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 915382
13 September 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 915706
8 July 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 933129
10 June 1990
Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1212555
26 April 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1231872
17 April 1990
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 925445
1 April 1990
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 903659
16 March 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1236774
9 March 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223589
25 January 1990
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 904099
14 January 1990
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223850
10 January 1990
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1239359
7 January 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1226689
29 December 1989
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 918305
28 December 1989
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 916459
1 December 1989
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1213469
26 November 1989
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1213349
19 November 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 911535
15 October 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1197912
1 October 1989
Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1025286
6 September 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1203156
25 August 1989
Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1341260
25 July 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1034536
19 July 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1206489
8 July 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1342924
1 July 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 898210
24 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197434
17 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1343136
3 June 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1194635
3 March 1989
Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197740
Fire Fighting
Issued 6 October 1993
Resolved
EXTEND SPRINLER HEADS IN GIFT SHOP BEYOND CEILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 October 1993
Resolved 18 October 1993
Engineering
Issued 6 October 1993
Resolved
INSTALL MACHINERY GUARDS ON DRIVE SHAFTS IN VENTILATILION ROOMS 3 AND 4.
Condition: Unknown
Due 6 January 1994
Resolved 18 October 1993
Electrical
Issued 6 October 1993
Resolved
INSTALL LATCH ON POWER DISTRIBUTION BOX COVER L11 NEXT TO STATEROOM A148.
Condition: Unknown
Due 6 January 1994
Resolved 18 October 1993
Lifesaving
Issued 6 October 1993
Resolved
INSTALL LAGGING TO EXPOSED PORTIONS OF EXHAUST PIPING ON LIFEBOAT #1.
Condition: Unknown
Due 18 October 1993
Resolved 18 October 1993
Construction/Loadline
Issued 6 October 1993
Resolved
PROVE PROPER OPERATION OF ALL WATERTIGHT DORS IN THE REMOTE MANUAL MODE.
Condition: Unknown
Due 12 October 1993
Resolved 18 October 1993
Electrical
Issued 6 October 1993
Resolved
CLEAN PAINT FROM PAINT LOCKER VENT SCREEN.
Condition: Unknown
Due 12 October 1993
Resolved 18 October 1993
Accommodation/Occupational Safety
Issued 6 October 1993
Resolved
CORRECT VENTILATION LEAKS THAT CAUSES A POSITIVE PRESSURE IN THE OVERHEAD ON THE CARIBBEAN AND ATLANTIC DECKS.
Condition: Unknown
Due 6 January 1994
Resolved 18 October 1993
Electrical
Issued 6 October 1993
Resolved
REPLACE MISSING LIGHT COVERS IN THE FOLLOWING SPACES: LAUNDRY, STEERING, BAR LOCKER, PASSENGER & CREW CORRIDORS.
Condition: Unknown
Due 6 January 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 6 October 1993
Resolved
AT NEXT DRYDOCK BUT NO LATTER THAN 6JAN94 MAKE BOUNDRIES OF GIFT SHOP COME INTO COMPLIANCE WITH SOLAS CHAPTER II-2 REG 26 TABLE 26.2
Condition: Unknown
Due 6 January 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 30 June 1993
Resolved
CORRECT A/C SUPPLY LEAK ABOVE OVERHEAD AT FIRE SCREEN DOOR 75.
Condition: Unknown
Due 8 July 1993
Resolved 21 July 1993
Fire Fighting
Issued 30 June 1993
Resolved
ENSURE ALL FIRE SAFETY DOORS LEADING TO THE ENGINE ROOM SELF CLOSE AND LATCH.
Condition: Unknown
Due 2 October 1993
Resolved 21 July 1993
Fire Fighting
Issued 30 June 1993
Resolved
REMOVE ALL PAINT FROM THE PAINT LOCKER LOCATED ABOVE THE BOW THRUSTER COMPARTMENT. ELECTRICAL INSTALLATION IN COMPARTMRNT DOES NOT COMPLY WITH REG 27(b)(ii)&(iii) OF SOLAS 60.
Condition: Unknown
Due 8 July 1993
Resolved 21 July 1993
Engineering
Issued 30 June 1993
Resolved
HAVE CLASS COMMENT ON THE SUITABILITY OF THE VALVES USED FOR THE FUEL TANK SIGHT GLASSES LOCATED ON THE FORWARD BULKHEAD OF THE AUX. MACHINERY SPACE ADJACENT TO THE POWER OPERATED FUEL VALVES.
Condition: Unknown
Due 30 June 1993
Resolved 30 June 1993
Construction/Loadline
Issued 30 June 1993
Resolved
PROVE PROPER OPERATION OF ALL WATERTIGHT DOORS IN THE REMOTE MANUAL MODE.
Condition: Unknown
Due 30 June 1993
Resolved 30 June 1993
Deck/Cargo
Issued 30 June 1993
Resolved
CORRECT HYDRAULIC ON CRANE LOCATED STARBOARD SIDE FORWARD MAINDECK.
Condition: Unknown
Due 8 July 1993
Resolved 21 July 1993
Electrical
Issued 30 June 1993
Resolved
RENEW CRACKED FLEXIBLE FUEL LINE ON THE #1 SSG.
Condition: Unknown
Due 30 June 1993
Resolved 30 June 1993
Fire Fighting
Issued 30 June 1993
Resolved
LABEL NEW & EXISTING FIRE ALARM PULL BOXES TO CORRESPOND TO ZONE OR INDICATOR ON BRIDGE ALARM PANEL.
Condition: Unknown
Due 30 June 1993
Resolved 30 June 1993
Fire Fighting
Issued 30 June 1993
Resolved
Provide proper boundries to photo lab in the reception area.
Condition: Unknown
Due 30 June 1993
Resolved 30 June 1993
Fire Fighting
Issued 30 June 1993
Resolved
PROVIDE CLASS APPROVAL OF MODIFIED FIRE CONTROL PLAN.
Condition: Unknown
Due 2 January 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 8 April 1993
Resolved
PROVIDE A LOADLINE CERTIFICATE WHICH ACCURATELY SHOWS HOW VESSEL IS MARKED.CURRENT LOADLINE SHOWS A MINIMUM FREEBOARD AT 1498MM. THE PSSC REQUIRES 2108 MM.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Fire Fighting
Issued 8 April 1993
Resolved
PROVIDE PROPER BOUNDRIES TO PHOTO LAB IN THE RECEPTION AREA.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Fire Fighting
Issued 8 April 1993
Resolved
BY 1997 MODIFY THE STAIRWAYS MIDSHIPS SO THAT DIRECT ACCESS IS NOT GIVEN TOTHE FOLLOWING SPACES: 1) CREW PURSER'S OFFICE, 2) HOTEL MANAGER'S OFFICE, 3) CABINS C229 - C232, 4) SHOPPING ARCADE, AND 5) RECEPTION.
Condition: Unknown
Due 31 December 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 8 April 1993
Resolved
THE CONSTRUCTION OF STORE ROOMS ON THE CARGO DECK REQUIRES THESE "SERVICE" SPACES TO BE SPRINKLERED BY A REGULATION 12 SPRINKLER SYSTEM.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Accommodation/Occupational Safety
Issued 8 April 1993
Resolved
PROVIDE PROPER NOTICES TO PASSENGERS CONCERNING EMERGENCY INSTRUCTIONS AND MUSTER STATIONS IN CABINS.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Electrical
Issued 8 April 1993
Resolved
REPAIR #3 SHIP SERVICE GENERATOR AND CONDUCT OPERATIONAL TEST.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Lifesaving
Issued 8 April 1993
Resolved
PROVIDE EMERGENCY EMBARKATION LIGHTS AT ALL 4 DAVIT LAUNCH LIFE RAFT STATIONS.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Documentation
Issued 8 April 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Fire Fighting
Issued 8 April 1993
Resolved
MODIFY THE FIRE CONTROL PLANS TO PROPERLY INDICATE ZONES TO CLOSE ON THE FIRE SCREEN DOOR SWITCH PANEL. CURRENTLY THE PLAN DOES NOT SHOW THE ACTUALOPERATING ARRANGMENTS OF THE SWITCHES.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Fire Fighting
Issued 8 April 1993
Resolved
SUBMIT THE FIRE CONTROL PLAN AND STRUCTURAL FIRE PROTECTION PLAN TO THE MARINE SAFETY CENTER IN WASHINGTON D.C. FOR REVIEW FOR COMPLIANCE WITH THE APPLICABLE SOLAS REGULATIONS.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Navigation
Issued 2 April 1993
Resolved
The Scandinavian Song, a vessel of greater than 1600 gross tons, failed to have an operational gyrocompass. The vessel also made entry into U.S. waters without it's gyro in operational condition.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Navigation
Issued 2 April 1993
Resolved
The master of the Scandinavian Song, a vessel of 8496 gross tons, failed toreport an inoperative gyro compass to the Captain of the Port prior to arrival. The vessel's ARPA was also inoperative and was also not reported.
Condition: Unknown
Due 9 June 1993
Resolved 9 June 1993
Documentation
Issued 2 April 1993
Resolved
The Scandinavian Song, a vessel of greater than 300 gross tons, failed to have a Certificate of Financial Responsibility for the present operator on board.
Condition: Unknown
Due 4 August 1993
Resolved 4 August 1993
Fire Fighting
Issued 19 November 1992
Resolved
Provide means to verify flow thru drencher system piping to nozzles. To becompleted to the satisfaction of classification society._x001C_
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Fire Fighting
Issued 19 November 1992
Resolved
Make permanant repairs to two holes in firemain piping at tunnel firepump._x001C_Temporary patches holding at operating pressure.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 31 March 1992
Resolved
MAKE REPAIRS TO #6 LIFEBOAT DAVIT TO THE SATIFACTION OF THE CLASS SOCIETY. VESSEL IS LIMITED TO 799 PASSENGERS UNTIL THIS ITEM HAS BEEN CLEARED.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Lifesaving
Issued 31 March 1992
Resolved
PROVIDE TWO (2) SURVIVAL CRAFT EPIRBS (121.5/243MHZ). ONE TO BE LOCATED ON EACH SIDE OF THE VESSEL.
Condition: Unknown
Due 30 April 1992
Resolved 2 June 1992
Construction/Loadline
Issued 11 June 1991
Resolved
PERMANENTLY FIX HOLE IN AFTER PEAK VENT LINE, PORT SIDE.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Accommodation/Occupational Safety
Issued 11 June 1991
Resolved
REWORK THE RELEASES TO THE FOLLOWING FIRE DAMPERS TO MAKE THEM READILY OPERABLE: No's 26, 27, 28, 29 and 38.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Construction/Loadline
Issued 11 June 1991
Resolved
RESTORE LOCAL POWER OPERATION OF ALL SLIDING WATER TIGHT DOORS.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Fire Fighting
Issued 13 March 1991
Resolved
REPAIR LATCH FSD NO. 24.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Fire Fighting
Issued 13 March 1991
Resolved
REPAIR LATCH FSD NO. 34.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Engineering
Issued 13 March 1991
Resolved
REPAIR WATER LEAKS STBD MAIN ENGINE #5 CYL.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Fire Fighting
Issued 13 March 1991
Resolved
MAKE PROPER FIRE BOUNDARY PENETRATION PORT SIDE CAR DECK, NEW WELD MACHINE CABLE.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 13 March 1991
Resolved
PROVIDE OUTLET COVER, NEW WELDING MACHINE.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 13 March 1991
Resolved
INSTALL 24V EMERGENCY LIGHTS OUTSIDE CREW LAUNDRY STAIRS STBD AND OPPOSITE PORT STAIRS.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Lifesaving
Issued 13 March 1991
Resolved
TAKE NECESSARY ACTION TO INSURE NO. 1, 2, 3, AND 6 LIFEBOATS ENGINES WILL START WITHOUT ETHER WHEN 45 DEGREES AMBIENT TEMPERATURE.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 28 November 1990
Resolved
INADEQUATE 24V LT - STAIRS GOING UP FROM FSD3.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
NO 24V LTS AT MUSTER STA 1.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
PROBABLE INADEQUATE 24V LTS AT MUSTER STA 2.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
INADEQUATE 24V LTS FROM WTD2 FORWARD INCLUDING CORRIDORS.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
NO 220 E LIGHTS AT EITHER MUSTER STA.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Engineering
Issued 28 November 1990
Resolved
INCINERATOR PULL MARKING (F.D).
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Accommodation/Occupational Safety
Issued 28 November 1990
Resolved
STBD CASINO ESCAPE 24V "E".
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Lifesaving
Issued 28 November 1990
Resolved
L/R LAUNCH - MANUAL INSTR.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Construction/Loadline
Issued 28 November 1990
Resolved
PL DK HATCH BOLTS.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
NO E LTS INCINERATOR RM (24 OR 220).
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
NO E LTS (24V) ADV DECK.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
NO E LTS (24V) HYD RM.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
24V LT NOT WORKING ABOVE FSD 10.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
NO E LTS (24V) STEERING & F. PUMP.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
24 LT NOT WORKING ABOVE WTD 25.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Fire Fighting
Issued 10 June 1990
Resolved
REMOVE ALL HOLDBACK HOOKS ON FSD'S.
Condition: Unknown
Due 10 June 1990
Resolved 10 June 1990
Engineering
Issued 10 June 1990
Resolved
LABLE REMOTE F/O VALVES 1 THRU 9 TO CORRESPOND TO ACTUATORS.
Condition: Unknown
Due 10 June 1990
Resolved 10 June 1990
Fire Fighting
Issued 10 June 1990
Resolved
KEEP SPRINKLER PUMP DISCHARGE VALVE LOCKED OPEN.
Condition: Unknown
Due 10 June 1990
Resolved 10 June 1990
Fire Fighting
Issued 10 June 1990
Resolved
INSTALL A SIGN "THIS VALVE MUST BE OPEN AT ALL TIMES" ON THE SPRINKLER PUMP SUCTION VALVE.
Condition: Unknown
Due 10 June 1990
Resolved 10 June 1990
Construction/Loadline
Issued 10 June 1990
Resolved
PERMANENTLY REPAIR #1 & 3 WATER TIGHT DOOR LOCAL CONTROL HANDLE. SHOW IT RETURNS TO NEUTRAL.
Condition: Unknown
Due 10 June 1990
Resolved 10 June 1990
Construction/Loadline
Issued 10 June 1990
Resolved
REPAIR CRACKED HINGE ON AFT HATCH.
Condition: Unknown
Due 10 June 1990
Resolved 10 June 1990
Accommodation/Occupational Safety
Issued 10 June 1990
Resolved
MARK ALL FIRE DAMPERS "OPEN" AND "CLOSED".
Condition: Unknown
Due 10 June 1990
Resolved 10 June 1990
Fire Fighting
Issued 10 June 1990
Resolved
REPAIR LEAKING WATER TIGHT DOOR MANUAL CONTROL VALVES ON ADV. DECK. PROVIDE A PROPOSAL BY 17 JUNE 1990.
Condition: Unknown
Due 10 June 1990
Resolved 10 June 1990
Fire Fighting
Issued 1 April 1990
Resolved
MARK ALL NEW FIRE DAMPERS WITH "OPEN - CLOSE" INDICATORS.
Condition: Unknown
Due 1 April 1990
Resolved 1 April 1990
Construction/Loadline
Issued 16 March 1990
Resolved
VERIFY THAT ALL SLIDING WATERTIGHT DOORS ARE IN COMPLIANCE WITH SOLAS 60 CHAPTER II REGULATION 13.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Fire Fighting
Issued 16 March 1990
Resolved
REPLACE TEMPORARY REPAIR MADE TO SPRINKLER ZONE 13 WATER LINE.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Construction/Loadline
Issued 16 March 1990
Resolved
THE BOUNDARIES OF THE AIR HANDLING ROOMS, ATLANTIC DECK APPROX. FRAME 126 ARE A CLASS. THE PENETRATIONS ARE NOT A CLASS AND THE DUCTING PASSING THRU ARE NOT FITTED WITH FIRE DAMPERS OPERABLE FROM BOTH SIDES OF THE BULKHEAD. MAKE MODIFICATIONS TO MAKE IT A-O AND INVESTIGATE THE DUCTING WHICH (CONT)
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Construction/Loadline
Issued 16 March 1990
Resolved
RUNS VERTICAL FROM THIS SPACE TO SEE IF IT ALSO PENETRATES AN A CLASS BOUNDARY.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Construction/Loadline
Issued 16 March 1990
Resolved
THE BOUNDARY BETWEEN THE AIR HANDLING ROOM AFT AND THE MAIN DINING ROOM, SHOULD BE A CLASS IN ACCORDANCE WITH REGULATIONS 40 AND 35(K). THE AIR DUCTS PENETRATING THIS BOUNDARY ARE TO BE FITTED WITH FIRE DAMPERS AND THE BULKHEAD IS TO BE A-O.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Fire Fighting
Issued 16 March 1990
Resolved
REPAIR OR REPLACE THE FOLLOWING FIRE SCREEN DOORS: 5, 35, 71, 85, 88, 89, 91.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Fire Fighting
Issued 16 March 1990
Resolved
REPAIR FIRE DAMPER 34.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Fire Fighting
Issued 16 March 1990
Resolved
PROVIDE EASY ACCESS TO OPERATE FIRE DAMPERS LOCATED ABOVE FSD 55.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Fire Fighting
Issued 16 March 1990
Resolved
PROVIDE KEYS TO ROOM DOORS 141 AND 142 TO TEST FIRE DAMPERS INSIDE ROOMS.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Fire Fighting
Issued 16 March 1990
Resolved
REPAIR FIRE DAMPER 91 AND PROVIDE ADEQUATE ACCESS ON EXERCISE ROOM SIDE.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Deck/Cargo
Issued 16 March 1990
Resolved
PROVIDE CLOSING DEVICE ON CASINO SIDE OF DUCT FROM GALLEY, WITH QUICK ACCESS.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Construction/Loadline
Issued 16 March 1990
Resolved
COMPLETE INSTALLATION OF A CLASS BOUNDARY AT THE TOP OF FRAME 75 STAIRS BETWEEN FSD AND DINING ROOM.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Construction/Loadline
Issued 14 January 1990
Resolved
FREE UP AND DEMONSTRATE THE STBD AND PORT E/R ESCAPE DOOR LEADING ONTO THE EMBARKATION DECK.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Electrical
Issued 14 January 1990
Resolved
PERMANTLY WIRE IN THE FIRE ALARM PUSHBUTTON ZONE 16 AT THE STAIRS.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Navigation
Issued 14 January 1990
Resolved
ADJUST RUDDER ANGLE INDICATOR, OFF 10 DEG.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
FOLLOWING FIRE DAMPERS DO NOT CLOSE OR ONLY PARTIALLY CLOSE: 26, 21, 25, 9673,74,81,91,3,9, STBD ABOVE GLASS DOORS, AFT 1 DECK BELOW FS DOOR 89 DAMPERIN FAN ROOM THRU FS DOOR 54 (PORT).
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
FOLLOWING FIRE SCREEN DOORS WON'T RELEASE, LATCH OR LATCH IS DEFECTIVE OR MISSING: 92,89,84,83,71,59,60,51 7,5,74,3,18,20,86.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
FOLLOWING FS DOORS HAVE HOLD BACKS: 94,5,92.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Accommodation/Occupational Safety
Issued 14 January 1990
Resolved
REPAIR A/C BLOWER SHUT DOWN TO ACCOMMODATIONS.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Construction/Loadline
Issued 14 January 1990
Resolved
ALL SLIDING DOORS DO NOT APPEAR TO MEET THE STRUCTURAL FIRE PROTECTION OF THE BULKHEAD THEY ARE IN WHEN CLOSED.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Lifesaving
Issued 14 January 1990
Resolved
NO. 1 LIFEBOAT ENGINE VERY DIFFICULT TO START, REPAIR OR REPLACE ENGINE.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Lifesaving
Issued 14 January 1990
Resolved
REPLACE EMBARKATION LADDER AT #1 LIFEBOAT.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Electrical
Issued 14 January 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Engineering
Issued 14 January 1990
Resolved
REMOVE RUBBER HOSE FROM FUEL TANK SIGHT GLASSES.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
FS DOOR 56 HITS SPRINKLER HEAD WHEN OPEN.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
BREAK GLASS HAMMERS MISSING FOR FIRE ALARM: BARRACUDA DISCO, GENERATOR ROOMBUTTON AT F. STATION 66.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
FIRE ALARM BUTTON AT MAIN STAIRS, ZONE 16 INOPERATIVE.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Navigation
Issued 14 January 1990
Resolved
STEERING ROOM DECK FLOODED.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Construction/Loadline
Issued 14 January 1990
Resolved
ALL WT HATCHES IN ADV. DECK ARE NOT BOLTED DOWN.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Construction/Loadline
Issued 14 January 1990
Resolved
STEERING ESCAPE HATCH HAS NO DOGS, TO BE OPERATABLE FROM BOTH SIDES AND WATERTIGHT.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Construction/Loadline
Issued 14 January 1990
Resolved
AFT PEAK OPEN, HAS 2-3 FT. OF WATER.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
F. STA. HYDRANT #62 STEERING ROOM IN BROKEN. NO FITTING TO ATTACH HOSE.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
F. STA. HYDRANT COUPLING LEAKS #22.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
F. STA. #4 NOZZLE WON'T FIT ON HOSE.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
F. STA. #10 NOZZLE LEAKS.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Electrical
Issued 14 January 1990
Resolved
REPAIR E. LIGHT CHART ROOM.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Electrical
Issued 14 January 1990
Resolved
INSTALL E. LIGHTS: OFFICER PANTRY, EXERCISE ROOM.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 14 January 1990
Resolved
REPAIR EMERGENCY FIRE PUMP SEAL.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Engineering
Issued 26 November 1989
Resolved
FOLLOW CLASS SOCIETY SURVEYOR'S RECOMMENDATION TO USE BOTH CONTROL AIR TANKS, 3 AIR COMPRESSORS ON LINE AT 1ST MANEUVER AND REPAIR MAIN COMPRESSORASAP. PROVIDE WRITTEN VERIFICATION THAT THIS HAS BEEN COMPLETED.
Condition: Unknown
Due 26 November 1989
Resolved 26 November 1989
Fire Fighting
Issued 19 November 1989
Resolved
PROVIDE MISSING FIRE EXTINGUISHER.
Condition: Unknown
Due 19 November 1989
Resolved 19 November 1989
Fire Fighting
Issued 19 November 1989
Resolved
REPAIR FSD'S 35, 40, 61, 85, 89.
Condition: Unknown
Due 19 November 1989
Resolved 19 November 1989
Deck/Cargo
Issued 19 November 1989
Resolved
PROPERLY STOW ALL PAINT IN PAINT LOCKER.
Condition: Unknown
Due 19 November 1989
Resolved 19 November 1989
Deck/Cargo
Issued 19 November 1989
Resolved
PAINT LOCKER ON ADVENTURE DECK DOES NOT MEET SOLAS 60 REQUIREMENTS; REG 27 (B)(III): ELEC. EQUIP. NOT EXPLOSION PROOF; REG 45: TO BE IN A CLASS BOUND;REG 51: NO FIRE DETECTORS; REG 59: NO SPRINKLER SYSTEM.
Condition: Unknown
Due 19 November 1989
Resolved 19 November 1989
Accommodation/Occupational Safety
Issued 19 November 1989
Resolved
ENCLOSE STAIR TOWERS AT P&S FRAMES 75 AND FRAME 100 TO A-O CONSTRUCTION NOTLATER THAN 09JAN90.
Condition: Unknown
Due 19 November 1989
Resolved 19 November 1989
Accommodation/Occupational Safety
Issued 19 November 1989
Resolved
REPAIR HANDRAIL PORT FORWARD LEADING FROM BRIDGE TO DECK BELOW.
Condition: Unknown
Due 19 November 1989
Resolved 19 November 1989
Fire Fighting
Issued 15 October 1989
Resolved
REPAIR FIRE SCREEN DOOR #61 (LATCH). CONDUCTED FIRE AND BOAT DRILLS. DID NOT LAUNCH BOATS. PORT SET TO EMB. DECK ENGINES STARTED. STILL NOT PROVIDING BLANKETS, DUE TO CREWMEMBER UNABLE TO SPEAK ENGLISH AND ROSTER CARDS ARE ENGLISH ONLY. FOUND EXTRA PEOPLE WHO SHOULD HAVE BEEN AT (CONT.)
Condition: Unknown
Due 15 October 1989
Resolved 15 October 1989
Fire Fighting
Issued 15 October 1989
Resolved
(CONT.) THE MUSTER AREA AND 5 CREW IMPROPERLY DONNING PFD'S.
Condition: Unknown
Due 15 October 1989
Resolved 15 October 1989
Documentation
Issued 15 October 1989
Resolved
ARRANGE FOR LOCAL RECEIPT OF NTM. LAST NTM RECEIVED 15OCT89 FROM ENGLAND WHICH WAS FORWARDED FRON NEW ORLEANS. THIS WAS NO. 36, ALREADY NO. 39 AVAILABLE.
Condition: Unknown
Due 15 October 1989
Resolved 15 October 1989
Accommodation/Occupational Safety
Issued 1 October 1989
Resolved
LABEL OUTSIDE OF VENTILATION SHUT DOWN PANEL. "REMOTE VENT SHUT DOWN"
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Electrical
Issued 1 October 1989
Resolved
REPAIR EMERGENCY GENERATOR EXHAUST LEAK LOCATED ABOVE GENERATOR.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Construction/Loadline
Issued 1 October 1989
Resolved
FWD AND CARGO DECK HATCHES MISSING DOGS.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Documentation
Issued 1 October 1989
Resolved
PREPARE A NEW MUSTER LIST SHOWING ALL CREW.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Construction/Loadline
Issued 1 October 1989
Resolved
LATCH MISSING ON PORT AFT WEATHER DOOR LEADING TO STERN.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Electrical
Issued 1 October 1989
Resolved
REPAIR VOLT METER ON EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Electrical
Issued 1 October 1989
Resolved
REPAIR ALL INOPERATIVE EMERGENCY LIGHTS POWERED FROM BATTERY BANK.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Construction/Loadline
Issued 1 October 1989
Resolved
SECURE HATCH IN OVERHEAD OF STEERING GEAR ROOM.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Fire Fighting
Issued 1 October 1989
Resolved
FIRE DOORS OPENING INTO ADVENTURE DECK SHALL BE AUTO CLOSING.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Fire Fighting
Issued 1 October 1989
Resolved
REPAIR FIRE SCREEN DOOR #68, 67, 57.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Engineering
Issued 1 October 1989
Resolved
GASOLINE OR PROPANE STOWED ON STERN SHOULD BE LASHED OR IN RACKS.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Lifesaving
Issued 1 October 1989
Resolved
ALL 4 MAN PASS. ROOMS DO NOT HAVE 4 LIFEJACKETS (IE. A154, 152, 142: 3 EACH/ALSO ONLY 1)
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Documentation
Issued 1 October 1989
Resolved
PROPER LOG ENTRIES ARE NOT BEING MADE FOR WEEKLY DRILLS.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Fire Fighting
Issued 1 October 1989
Resolved
PROVIDE MEANS OF PREVENTING GLASS DOORS IWO FIRE DOORS FROM PREVENTING THE FIRE SCREEN DOOR CLOSING.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Fire Fighting
Issued 1 October 1989
Resolved
FIRE CREW SHOULD BE PROVIDED WITH AN AIR BREATHING APPARATUS FOR EACH LEAD MAN ON THE FIRE HOSE.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Fire Fighting
Issued 1 October 1989
Resolved
DURING FIRE AND BOAT DRILL A SYSTEM SHOULD BE ESTABLISHED FOR RECORDING ALLREPORTS TO THE BRIDGE (I.E. - 1. FIRE TEM #1 MANNED AND READY 2. ALL PASS.CLEARED FROM ACCOMMODATIONS. 3. LIFEBOAT #4 MANNED AND READY ETC.)
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Engineering
Issued 1 October 1989
Resolved
PROVIDE TRAINING IN THE OPERATION OF REMOTE FUEL SHUTOFF VALVES AND REMOTE VENTILATION SHUT DOWN.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Engineering
Issued 1 October 1989
Resolved
REPAIR THE FOLLOWING REMOTE F/O SHUT OFF VALVES: 1 - F/O SERVICE TANK SUCTION TO TRANSFER PUMP. 2 - DIESEL OIL SERVICE TANK. 3 - F/O SETTLING TANK SUCTION.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Navigation
Issued 1 October 1989
Resolved
CHARTS ARE NOT UP TO DATE.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Fire Fighting
Issued 3 June 1989
Resolved
COMPLETE ALL ITEMS LISTED ON WORK LIST ISSUED BY MSO NEW ORLEANS ON 3 JUN89
Condition: Unknown
Due 3 June 1989
Resolved 3 June 1989
Engineering
Issued 3 June 1989
Resolved
CORRECT DISCREPANCIES AS LISTED ON BUREAU VERITAS LETTER DATED 2 JUN 89 CONCERNING ENGINE ROOM CONDITION AND REPAIRS.
Condition: Unknown
Due 3 June 1989
Resolved 3 June 1989
Fire Fighting
Issued 3 June 1989
Resolved
CORRECT DISCREPANCIES AS LISTED ON PSI, INC. LETTER DATED 3 JUN 89 CONCERNING REPAIRS AND SERVICE NEEDED ON FIRE DOORS AND FIRE DAMPERS.
Condition: Unknown
Due 3 June 1989
Resolved 3 June 1989