LEOPARD is a 2001 freight ship. The Coast Guard has recorded 21 inspections since 2001, most recently in September 2010, along with 5 deficiencies and 11 operational controls.

Records from 2001 to 2010. Most recent: operational control imposed, 17 September 2010.

Built
2001
Last inspected
17 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9037276 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
BARBADOS
—
Maury page id
psix-32666

Inspections, by type

…with no type recorded12
Years with a record 5 calendar years (2001–2010)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it3146 - Convention (Subpart B), Net Ton
12175 - Displacement, Ton
9187 - Dead Weight, Ton
6167 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

17 September 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3851929
5 March 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3690510
3 March 2010 ISPS I Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3689007
20 February 2010 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3682933
5 February 2010 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3674175
26 January 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3673212
22 January 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3668258
4 June 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2088812
29 March 2004 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2033500
25 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2032182
18 March 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2027128
13 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2029408
21 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2010977
14 December 2003 Security Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2000547
12 December 2003 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1963134
7 November 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1943941
27 June 2003 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1830880
20 November 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1708142
19 March 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1494787
31 January 2002 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1481516
6 August 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 292634

Deficiency record · 5

Communications › Alarms/Indicators
Issued 18 March 2004 Resolved
The UMAS engine controls monitor in the engine room control room, was displaying a comm. error code between the UMAS alarm system control panel in the control room and the monitor. The C/E has unsuccessfully attempted to make repairs. However, the eng. call alarms for machinery operate correctly. LEGACY COMPONENT DESC: Engineers'''''''''''''''' Assistance-needed Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 June 2004
Resolved 29 March 2004
Resolution: Received class report stating the monitor will be repaired by 27 June 04 and does not effect the UMS designation.
Engineering › Steering Gear System
Issued 18 March 2004 Resolved
The No.2 hydraulic steering pump when placed in non follow-up mode at the main bridge control station did not operate. LEGACY COMPONENT DESC: Steering Mode Selector Switch
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 March 2004
Resolved 29 March 2004
Resolution: Received class report stating an inoperable limit switch prevented the No.2 steering pump to be operated in the follow-up mode. Class tested the steering pump in the follow-up mode with satisfactory results.
Navigation › Piloting/Steering › Marine Charts
Issued 31 January 2002 Resolved
VESEEL MISSSING BA CHART 2564 AND 2603 MUST PROVIDE FAX RECIEPT OF PURCHANCE TO MSO PHILADELPHIA PRIOR TO DEPARTURE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2002
Resolved 4 February 2002
Resolution: RECIEVED FAXED RECIEPT OF MISSING CHARTS
Documentation › Certificates/Documents
Issued 31 January 2002 Resolved
MISSING NEW CERTICIFICATE OF REGISTRY. OLD REGISTRY EXPIRED 02JAN02. MUST PROVIDE FAX OF NEW CERTICIFATE OF REGISTRY PRIOR TO DEPATURE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 February 2002
Resolved 4 February 2002
Resolution: RECEICED FAXED REPORT FOR CERTIFICATE OF REGISRTY
System not recorded
Issued 6 August 2001 Resolved
The stack funnel at funnel (top) deck was unwelded allowing rain water to enter the engine room. This prevented weathertight integrity to the engineroom. Also there was a cement patch around the smaller funnel vent. The vessel should make repairs to the satisfaction of class.
Condition: Unknown
Due 13 August 2001
Resolved 19 March 2002
Resolution: Cleared.

Ownership record