Records from 1989 to 1999. Most recent: inspection, 6 February 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
6 February 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 771175
5 February 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 210886
5 February 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 425068
5 February 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1418471
26 May 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 510857
19 February 1991
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 912222
18 February 1991
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 910862
14 December 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 334295
11 December 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 334224
25 November 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 446784
24 March 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 522147
16 March 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 329071
16 March 1989
Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1210309
Navigation
Issued 5 February 1999
Resolved
Local chart 11317 or an equivalent was not on board at the time of the boarding.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Construction/Loadline
Issued 5 February 1999
No resolution recorded
Support brackets on deck at #8 center tank, for small deck piping, are excessively corroded. Barckets must be replaced.
Condition: Unknown
Due 7 March 1999 — due date passed with no resolution recorded
Lifesaving
Issued 5 February 1999
No resolution recorded
Operating valve in emergency shower number one had failed rendering shower inoperative.
Condition: Unknown
Due 10 February 1999 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 5 February 1999
No resolution recorded
The catwalk over the cargo piping on the main deck is corroded in places and certain supports for the catwalk must be replaced.
Condition: Unknown
Due 7 March 1999 — due date passed with no resolution recorded
Construction/Loadline
Issued 5 February 1999
No resolution recorded
Oily water seperator did not have a proper placard listing the aprroval number for the piece of equipment.
Condition: Unknown
Due 7 March 1999 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 5 February 1999
No resolution recorded
Label with approval number was not on the MSD or was not readable.
Condition: Unknown
Due 7 March 1999 — due date passed with no resolution recorded
Construction/Loadline
Issued 5 February 1999
No resolution recorded
Six cargo tank hatch covers had missing closure devices. These tanks were not to be used in transfer operations until the closure devices had been installed.
Condition: Unknown
Due 7 March 1999 — due date passed with no resolution recorded
Deck/Cargo
Issued 5 February 1999
Resolved
Three hydraulic valves for deep well pumps had leaks and required repair prior to departure.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Navigation
Issued 18 February 1991
Resolved
THE WARNING STATEMENT MUST BE ADDED TO THE MANEUVERING FACT SHEET._x001C_ (33CFR164.35g7)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 February 1991
Resolved 18 February 1991
Navigation
Issued 18 February 1991
Resolved
THE BLOCK DIAGRAM MUST BE ADDED TO THE STEERING UNIT INSTRUCTIONS._x001C_ (33CFR164.35k)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 February 1991
Resolved 18 February 1991
Deck/Cargo
Issued 18 February 1991
Resolved
THE CARGO TRANSFER SYSTEM LINES 1P,1C,1S,2P,2S,6C & 8C (7 EACH) MUST BE HYDRO TESTED TO 1.5 MAWP PRIOR TO TRANSFER OF CARGO IN U.S. WATERS, THIS VOYAGE. (33CFR156.170)_x001C_ _x001C_
Condition: Unknown
Due 18 February 1991
Resolved 18 February 1991
Deck/Cargo
Issued 18 February 1991
Resolved
THE CARGO TRANSFER SYSTEM LINES 2C,3PCS,4PCS,5PCS,6PS & 7PCS (15 EACH) MUSTBE HYDRO TESTED PRIOR TO TRANSFER OF CARGO IN U.S. WATERS, PRIOR TO RETURN TO FIRST U.S. PORT, NEXT VOYAGE. (33CFR156.170)_x001C_ _x001C_
Condition: Unknown
Due 18 February 1991
Resolved 18 February 1991
Navigation
Issued 11 December 1989
Resolved
U.S. COAST PILOT FOR AREA TRANSITTED NOT CORRECTED AS PER 33 CFR 164.33(A)(2)(I)
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Navigation
Issued 11 December 1989
Resolved
CHARTS FOR AREA TRANSITTED NOT CORRECTED AS PER 33 CFR 164.33(A)(1)(II)
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Navigation
Issued 11 December 1989
Resolved
NO USCG LIGHT LIST ONBOARD FOR AREA TRANSITTED AND THE FOREIGN EQUIVALENT NOT CORRECTED TO DATE AS PER 33 CFR 164.33(A)(2)(II)
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989