Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)42.7 ft × 13.0 ft × 5.6 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHULLS UNLIMITED-EAST, INC · DELTAVILLE, VA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSOLOMONS, MD
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton 16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 23 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 23
11 February 2026Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8309286
22 December 2025Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8288385
15 October 2025Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8253099
27 September 2024Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8011808
26 July 2024Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7969635
27 December 2023Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7843345
26 October 2023Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7814866
24 February 2023Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7641301
14 February 2023Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7636376
27 December 2022Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7613402
20 October 2021Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7336573
6 October 2021Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7323673
13 April 2021Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7180780
18 December 2020Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7113867
15 October 2019DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6831970
1 October 2019Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6824683
17 April 2019Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6668286
14 December 2018DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6601916
18 December 2017Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6327016
24 October 2017Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6295720
8 December 2016Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6054685
25 October 2016COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6032494
18 October 2016Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6024733
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 December 2022Resolved
Filling and sounding pipes shall run as directly as possible from the deck connection to the top of the tank. Such pipes shall terminate on the weather deck clear of any coamings, and shall be fitted with shutoff valves, watertight deck plates, or screw caps suitably marked for identification. Fill and sounding pipes may terminate at the top of the tank. The fill pipe was located inside the engine compartment. It should terminate at the deck level.
46 CFR 182.20-30(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2023
Resolved 24 February 2023
Resolution: Vessel owner provided photographic evidence of the fuel fill pipe outside the engine compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 December 2022Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. The fuel shutoffs were not marked on the vessel.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 January 2023
Resolution: Received photo evidence of the fuel shutoff markings.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 December 2022Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. The batteries for the water lights were expired.
46 CFR 176.808(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 February 2023
Resolution: Received photo evidence of new float light batteries.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2021Resolved
Machinery space boundaries. Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. Engine room hatch and deck was missing approved non combustible fire retardant material. 46CFR177.410(c)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2021
Resolved 1 November 2021
Resolution: Vessel owner sent photographic evidence for insulation engine room hatch cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2020Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The positive lead on a primary electrical cable was found to be missing proper insulation leaving the conductor exposed
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2021
Resolved 13 April 2021
Resolution: Cable repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2020Resolved
An adult life jacket must be provided for each person carried on board a vessel. 04 adult life jackets were wasted. Total persons allowed limited to 16 until new life jackets are procured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2021
Resolved 13 April 2021
Resolution: New life jackets procured.
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2019
Resolved 18 December 2020
Resolution: Cleared during inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 December 2018Resolved
All vessels must have Nav Lights that are in compliance with Nave Rules. Found port running light and anchor light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2019
Resolution: Witnessed properly operating nav lights.
Engineering › Steering Gear System › Rudder Stock
Issued 25 October 2016Resolved
Vessel's rudder post allowed water intrusion into the vessel. Ensure rudder post is tightened to prevent water entry.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 7 November 2016
Resolution: Received email proof that the above deficiency was cleared.
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 7 November 2016
Resolution: Received email proof that the above deficiency was cleared.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 October 2016Resolved
Vessel did not record MOB drills as required and operator did not conduct MOB drill satisfactorily during examination. Vessel owner/operator must ensure all Master's operating vessel can satisfactorily conduct man overboard drills through training and provide documentation to local OCMI. 46 CFR 185.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 7 November 2016
Resolution: Received email proof that the above deficiency was cleared.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.