Behind this panel: 17 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
30 March 2026
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8325441
14 October 2025
COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8244544
13 January 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8060346
28 March 2024
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7876202
8 January 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7845426
22 December 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7605753
9 February 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7394215
5 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7376330
15 October 2020
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7072061
30 January 2020
Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6899508
13 January 2020
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6887316
17 January 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6612015
27 February 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6362927
17 January 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6339773
3 January 2017
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6065092
17 October 2016
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6024389
14 October 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6022712
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 October 2025
Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vessel does not have a magnetic compass on board. Procure and install marine-grade magnetic compass to satisfaction of attending marine inspector.
46 CFR 184.402
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2025
Resolved 28 October 2025
Resolution: Received picture of magnetic compass installed on vessel. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 January 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position or perform the duties and functions of a position, required by the vessel's COI. Marine employers may form or otherwise use sponsoring organizations, or may use contractors to conduct the random chemical testing programs. Vessel lacked evidence of DAPI program onboard. Present evidence for each item in DAPI audit.
46 CFR 16.230(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2022
Resolution: DAPI audit completed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 January 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Cable penetration openings for both outboards are not watertight. Seal cable penetration openings.
46CFR179.320(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 7 January 2022
Resolution: Received pictures of repaired cable penetration openings.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 January 2022
Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Original COI not onboard.
46CFR176.302
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 16 March 2022
Resolution: Submitted picture verification that the original COI was onboard to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 October 2020
Resolved
A vessel over 26 feet but less than 65 feet must be provided with one fixed power pump and one portable hand pump or one fixed hand pump and one portable hand pump. Vessel operates with one fixed hand pump and one portable hand pump but did not have the portable hand pump on board. Provide proper bilge pump arrangements.
46 CFR 182.520(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2020
Resolved 16 October 2020
Resolution: Verified portable hand pump on board vessel. //s// [name withheld], LT
Electrical › Electrical Distribution System (service) › Fuse
Issued 3 January 2017
Resolved
Provide electrical drawing for current systems onboard the vessel. Include fuse types and sizes. Provide wire gauge and length of run in the circuit. Fuses must be UL listed and appropriately sized.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 3 February 2017
Resolution: Electrical diagram submitted by the operator. Conductors are 14 AWG. Verified Cooper Bussmann cartridge fuses used for overcurrent protection.