← All vessels
MISS PARADISE
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named MISS PARADISE
MISS PARADISE is a 1989 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1989, most recently in January 2024, along with 107 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2022.
Records from 1989 to 2024. Most recent: inspection, 8 January 2024.
- Built
- 1989
- Last inspected
- 8 January 2024
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 107 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2022
Identity
945807
WDB9924
327165
Flag
UNITED STATES
366985150 (licence lapsed)
Maury page id
psix-327165
Inspections, by type
…with no type recorded3
Years with a record
33 calendar years (1989–2024)
The 67 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.0 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS · TARPON SPRINGS, FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portSANIBEL ISLAND, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDB9924MMSI 366985150 · expired · compulsorily equipped · granted 9 August 2014, cancelled 28 December 2024
WAE8619MMSI not assigned · expired · compulsorily equipped · granted 1 November 1994, cancelled 30 October 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 67
8 January 2024
Administrative Inspection · Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7868369
4 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7573639
29 September 2022
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579220
19 May 2022
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7453807
11 May 2022
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7447652
30 November 2021
Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7358731
21 June 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7231308
19 June 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6974644
5 December 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6863627
19 March 2019
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6645189
20 February 2018
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6356334
3 November 2017
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6296126
31 May 2017
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6161351
2 December 2016
Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6043607
8 December 2015
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5783593
21 October 2015
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5734281
26 March 2014
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4818179
7 December 2011
Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4200243
1 March 2010
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3687971
4 February 2009
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3411559
2 April 2008
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3175149
9 May 2007
Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2925321
5 January 2007
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2846056
9 February 2006
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2582155
6 June 2005
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2377192
8 February 2005
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2289146
23 January 2004
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1991265
2 September 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1796440
6 June 2003
Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1809346
12 February 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1744316
22 January 2003
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1733535
5 February 2002
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1490913
7 January 2002
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1477582
15 June 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1471254
7 February 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1057879
12 January 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1413860
8 September 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 822395
14 June 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1437754
29 February 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1046488
20 January 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1408472
12 January 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1464819
17 June 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1470177
14 May 1998
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1125837
1 April 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1454586
31 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 218506
25 February 1997
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1411424
12 February 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1357888
17 June 1996
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1442415
12 January 1996
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193056
3 April 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 855720
6 January 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1142874
29 June 1994
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1180632
10 January 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1162327
18 January 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 836283
13 January 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 836157
9 June 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 961387
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1312634
22 August 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308699
19 August 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 941197
13 June 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1000545
18 January 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1222736
13 December 1990
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1211605
13 June 1990
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 927718
28 September 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1304604
28 August 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1342589
15 June 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 893001
15 June 1989
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1204228
Deficiency record · 107
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022
No resolution recorded
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 May 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull…Upon entering the port hull aft compartment, water and air bubbles entered through the bottom of the hull in way of the keel. Could not determine exact location of damage. Owner to determine the condition of the hull by means of dry dock. At that time a Marine Inspector will attest to any damage and review any repair proposals. Passengers are not permitted until the vessel is deemed sea worthy.
46 CFR 177.100
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Both flashlights did not function.
46 CFR 183.430
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 May 2022
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented. No records could be found of any drills in the past 03 months.
46 CFR 185.520(f)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 May 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts. No charts were onboard.
46 CFR 184.420
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 May 2022
Resolved
Placards containing instructions for the donning and use of lifejackets aboard the vessel must be posted. No lifejacket donning placard was available.
46 CFR 185.516
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2022
Resolved
Portable fire extinguishers must be…installed and located to the satisfaction of the OCMI. 2-A extinguisher under the helm was not secured to a bracket and could easily roll out onto the deck.
46 CFR 181.520
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2022
Resolved
The number and identification of the items stowed inside, must be marked in clearly legible letters and numbers. Lifejacket stowage did not show child life jackets and the numbers were faded on all containers.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 June 2021
Resolved
FCC Safety Radio Certificate is expired. Vessel restricted to no more than 1,000 feet from shore until rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 June 2021
Resolved
Port side high water alarm is inoperable and electrical wiring is laying in bilge. Prove proper operation and re-wire.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2021
Resolved
Provide floating light for ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2021
Resolved
Fuel lines are not double clamped.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 June 2021
Resolved
Provide chart for navigation area.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2020
Resolved
Provide new 10-B:C fire extinguisher and mount near operating station.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 June 2020
Resolved
Prove operation of both bilge alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2020
Resolved
Provide 07 additional adult life jackets. Passenger count reduced to 42 until rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 June 2020
Resolved
Provide 03 additional red hand flares to replace expired onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 March 2019
Resolved
Vessel missed annual inspection, do not carry passengers until COI renewal is complete. (46CFR176.500)
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 February 2018
Resolved
Replace 60 ft line on life ring and line for light. (46CFR180.70)
Electrical › Electric Supply System (service) › Cable
Issued 20 February 2018
Resolved
Cover spliced wires to both forward navigation lights. (46CFR176.800)
Construction/Loadline › Structures › Deck Plating
Issued 3 November 2017
Resolved
Repair rotted deck aft of starboard hatch below second stanchion rail. (46CFR176.600)
Construction/Loadline › Hull › Bottom Plating
Issued 3 November 2017
Resolved
Add new layer of FRP to both hulls for beaching (46CFR176.600)
Documentation › Markings/Placards › Warning Signs
Issued 2 December 2016
Resolved
Replace fuel shut-off placards on both tanks.
Engineering › Fuel Oil Service System › Hose
Issued 2 December 2016
Resolved
Put two hose clamps on both fuel lines.
Communications › Audible Communications › Bell
Issued 2 December 2016
Resolved
Replace clapper on bell.
Fire Fighting › Fire Bucket › Capacity
Issued 2 December 2016
Resolved
Replace fire buckets woith 2.5 gallon buckets or drill 5 gallon buckets to make then 2.5 gallons.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 December 2015
Resolved
Starboard navigation light was inop, repair / replace.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 December 2015
Resolved
Vessel does not have required amount of aspirin in first aid kit. Provide proper amount on board (100).
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 8 December 2015
Resolved
Provide current MIS report for 2014.
Stability › Watertight Integrity › General
Issued 8 December 2015
Resolved
Hatch on port side handle has broken handle. Repair / replace hatch.
Construction/Loadline › Hull › Side Shell
Issued 21 October 2015
Resolved
Repair all areas identified on hull to original.
Construction/Loadline › Penetrations › Valve Flange
Issued 21 October 2015
Resolved
Replace overboard valve.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 26 March 2014
Resolved
Vessels bilge high level alarm located on portside hull is inoperative. Repair or replace. 46 CFR 182.530
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 March 2014
Resolved
Vessels magnetic compass light is inoperative. Repair or replace and show proper operation. 46 CFR 184.402
Navigation › Piloting/Steering › Marine Charts
Issued 26 March 2014
Resolved
Vessel's navigational charts, tides & currents, Navigation Rules, and Coast Pilot for area of operations are out of date. Provide updated charts, tides & currents, Navigation Rules, and Coast Pilot for the area of operations. 46 CFR 184.420
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 26 March 2014
Resolved
Vessels gas fuel hoses on both fuel tanks leading to fuel filters are deteriorated and cracked. Replace with new hoses on both fuel tanks. 46 CFR 176.25-50
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 March 2014
Resolved
DAPI audit revealed 3 individuals 2 of which were licensed mariners that were operating when there pre-employment drug/alcohol test had not been fully completed and verified on the consortiums employment roster. Provide proof of complete/proper enrollment/roster of employees (pre-employment) drug/alcohol testing. 46 CFR 16.210
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 March 2014
Resolved
Vessel could not produce original Certificate of Inspection for inspection. Local CG will process for renewal of Certificate of Inspection for the Owner/Operator. 46 CFR 176.502
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 March 2014
Resolved
Vessel does not have emergency fuel shut-off posted for operation of emergency fuel shut-offs in the event of an emergency. Post instructions for emergency fuel shut-offs for both emergency fuel shut-offs. 46 CFR 185..30-20
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 December 2011
Resolved
Passenger count is reduced to 48 until damaged adult lifejacket is replaced IAW 46 CFR 180.71.
Engineering › Gasoline Engine (propulsion) › Oil Pan (4 cycle)
Issued 7 December 2011
Resolved
Prove proper operation of port propulsion engine IAW 46 CFR 182.200.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 December 2011
Resolved
Conduct man overboard, fire and abandon ship drills IAW 46 CFR 185.520.
Engineering › Gasoline Engine (propulsion) › Piston (4 cycle)
Issued 2 March 2010
Resolved
Start outboard engine and test propulsion and steering.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 March 2010
Resolved
Service portable fire extinguisher and mount.
Lifesaving › Lifebuoys › Serviceable
Issued 2 March 2010
Resolved
Replace ring life buoy.
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 March 2010
Resolved
Post life jacket donning placard.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 March 2010
Resolved
Replace retro tape on (10) life jackets.
Navigation › Piloting/Steering › Marine Charts
Issued 2 March 2010
Resolved
Place chart and navigations pubs on vessel.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 March 2010
Resolved
Replace damaged aft deck
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 March 2010
Resolved
Remove wing nuts on battery.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 March 2010
Resolved
Replace missing items in first aid kit.
Lifesaving › Lifebuoys › Serviceable
Issued 5 January 2007
Resolved
Properly place retroreflective tape on ring buoy.
Engineering › Bilge Water Management System › Not Operational
Issued 5 January 2007
Resolved
Make permanent repairs to port visual high level bilge alarm.
Construction/Loadline › Structures › Deck Plating
Issued 13 February 2006
Resolved
Make repairs to main deck in accordance with the approved repair proposal.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 9 February 2006
Resolved
Provide training logbook with detailed description of drills and procedures.
Personnel › Training › Fire Fighting Basic
Issued 9 February 2006
Resolved
Provide emergency instruction list I.A.W. 46CFR185.25-5
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 February 2006
Resolved
Provide evidence of proper DAPI training for supervisors and crew.
Engineering › Bilge Water Management System › Not Operational
Issued 9 February 2006
Resolved
Make permanent repairs to the STBD bilge high level alarm.
Construction/Loadline › Structures › Deck Plating
Issued 9 February 2006
Resolved
Submit detailed repair proposals reguarding the soft deck area in way of the STBD aft console and STBD FWD of the lifejacket storage locker.
Construction/Loadline › Hull › Bottom Plating
Issued 6 June 2005
Resolved
BUILD UP SACRIFICIAL FRP IN WAY OF PORT AND STARBOARD BOW BOTTOM WHERE BEACHING OF VESSEL IS ERODING THE FIBERGLASS HULL.
Construction/Loadline › Hull › Collision Strap
Issued 6 June 2005
Resolved
GRIND OUT AND REPAIR FRACTURE IN WAY OF PORT BOW AT MAIN DECK CONNECTION AND PROPERLY REPAIR WITH FRP RESIN/MAT.
Construction/Loadline › Structures › Manhole
Issued 6 June 2005
Resolved
INSTALL NEW GASKET IN PORT AFT HATCH.
Engineering › Gasoline Engine (propulsion) › Valve, Reed (2 stroke)
Issued 6 June 2005
Resolved
INSTALL NEW ZINC ANODES IN WAY OF BOTH OUTBOARD ENGINES.
Documentation › Certificates/Documents › FCC SSL
Issued 8 February 2005
Resolved
Provide valid legible FCC Safety Certificate.
Navigation › Piloting/Steering › Marine Charts
Issued 8 February 2005
Resolved
Provide current chart for vessel's operating area.
Lifesaving › Lifebuoys
Issued 23 January 2004
Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR BOTH SIDES OF THE RING BOUY.
Electrical › Electric Supply System (service)
Issued 23 January 2004
Resolved
PROVIDE COVERS AND PROPER NUTS FOR BATTERY CONNECTIONS VICE WING NUTS. LEGACY COMPONENT DESC: Battery Installation
Construction/Loadline › Hull
Issued 4 June 2003
Resolved
Provide alternating layers of fiberglass mat, Red, yellow, green on FWD sections of hulls due to wearing of mat from vsl beachings. LEGACY COMPONENT DESC: Bottom Plating
Construction/Loadline › Structures
Issued 4 June 2003
Resolved
Re-tab first transverse deck support beam STBD FWD hull. LEGACY COMPONENT DESC: Transverse Bulkhead
Engineering › Bilge Water Management System
Issued 4 June 2003
Resolved
Re-new exterior (mushroom) portion of bilge discharge hose thru-hull fitting at port aft hull. LEGACY COMPONENT DESC: Piping
Engineering
Issued 4 June 2003
Resolved
Provide second hose clamp for head intake valve/hose connection.
Electrical › Lighting (emergency)
Issued 22 January 2003
Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT. LEGACY COMPONENT DESC: Battery Operated Lantern
Electrical › Electrical Distribution System (service)
Issued 22 January 2003
Resolved
PROPERLY SLICE WIRE CONNECTIONS WITH CRIMP TYPE CONNECTORS FOR ALL BILGE PUMPS AND HIGH WATER ALARMS. LEGACY COMPONENT DESC: Wiring
Electrical › Electrical Distribution System (service)
Issued 22 January 2003
Resolved
REMOVE DEAD END WIRE RUNS FROM STBD HULL LEADING OUT OF STEERING CONSLOE. LEGACY COMPONENT DESC: Wiring
Personnel › Training
Issued 22 January 2003
Resolved
PROVIDE FIRST AID AND CPR TRAINING FOR AT LEAST 50% OF CREW LEGACY COMPONENT DESC: First Aid/CPR
Operations/Management › Drug and Alcohol Testing
Issued 22 January 2003
Resolved
PROVIDE MIS REPORT FOR PREVIOUS YEAR. LEGACY COMPONENT DESC: MIS Submission
Engineering › Fuel Oil Service System
Issued 22 January 2003
Resolved
PROVIDE PLANS FOR NEW FUEL TANK INSTALLATION PRIOR TO 01 FEB03 AS REQUIRED BY INSPECTION CONDUCTED 12JAN01. LEGACY COMPONENT DESC: Portable Fuel System
Engineering › Fuel Oil Service System
Issued 22 January 2003
Resolved
OWNERS MUST HYDRO-TEST TANK NLT 7MAR03 TO SHOW COMPLIANCE WITH MSO TAMMS LTR #945807 LEGACY COMPONENT DESC: Tank
Operations/Management › Drug and Alcohol Testing
Issued 10 January 2002
Resolved
Provide proof of enrollment in drug program. LEGACY COMPONENT DESC: Proof of Enrollment
Communications › Alarms/Indicators
Issued 10 January 2002
Resolved
Repair high water bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Operations/Management › Drills/Instruction
Issued 10 January 2002
Resolved
Entered in error. No deficiency.
Engineering › Gasoline Engine (propulsion)
Issued 10 January 2002
Resolved
MAKE REPAIRS TO BOTH PROPULSION ENGINES. WILL RETURN TO CONDUCT SEA TRIALS UPON REPAIRS AND NOTIFICATION FROM OWNER.
Engineering › Fuel Oil Service System › Tank
Issued 12 January 2001
Resolved
PROVIDE PROOF THAT VESSEL IS IN COMPLIANCE WITH 46CFR177.410(b) OR INSTALL GASOLINE FUEL SYSTEM (TANKS) IAW 46CFR177.410(d)(2). EVALUATE SERVICEABILITY OF FIBERGLASS FUEL TANKS CONDITION AT EACH DRYDOCK.
Electrical
Issued 12 January 2001
Resolved
REMOVE DEAD END WIRING FROM STARBOARD HULL AND UNDER HELM CONSOLE.
Lifesaving
Issued 12 January 2001
Resolved
BRING FIRST AID KIT INTO COMPLIANCE WITH 46CFR160.041.
Fire Fighting
Issued 12 January 2001
Resolved
SEVICE 1 B-I PORTABLE FIRE EXTINGUISHER.
Construction/Loadline
Issued 12 January 2001
Resolved
INSTALL CHECK VALVE OR ONE-WAY VALVE ON BOTH PORT AND STARBOARD BILGE PUMP IN AFT COMPARTMENTS.
Construction/Loadline
Issued 14 June 2000
Resolved
MAKE REPAIRS TO PORT AND STARBOARD HULLS ON BOTTOM SHELL FORWARD WHERE WORNFROM BEACH LANDINGS.
Fire Fighting
Issued 20 January 2000
Resolved
PROVIDE AND INSTALL PROPER BRACKETS FOR PORTABLE FIRE EXTINGUISHERS.
Electrical
Issued 20 January 2000
Resolved
PROPERLY MOUNT BATTERIES TO PREVENT MOVEMENT.
Lifesaving
Issued 20 January 2000
Resolved
INSTALL RETRO-REFLECTIVE TAPE ON RING BUOY AND 3-6 FOOT LANYARD WITH CLIP ON LIGHT.
Documentation
Issued 20 January 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 20 January 2000
Resolved
REWRITE EMERGENCY INSTRUCTIONS TO MAKE APPLICABLE TO THE VESSEL.
Navigation
Issued 20 January 2000
Resolved
MAKE REPAIRS TO WIRING AND LIGHT FOR MAGNETIC COMPASS.
Navigation
Issued 20 January 2000
Resolved
PROVIED AND POST EMERGENCY BROADCAST PLACARD.
Accommodation/Occupational Safety
Issued 20 January 2000
Resolved
INSTALL ADEQUATE RAILING AT EACH GANGWAY ENTRANCE.
Lifesaving
Issued 20 January 2000
Resolved
PROPERLY LABLE LIFEJACKET STOWAGE LOCKERS AND SEPARATE CHILD AND ADULT JACKETS.
Lifesaving
Issued 20 January 2000
Resolved
PROVIDE AND POST PFD DONNING PLACARDS FOR BOTH STYLE PFD'S.
Lifesaving
Issued 20 January 2000
Resolved
PROVIDE AN APPROVED FIRST AID KIT.
Unknown
Issued 12 February 1997
Resolved
RENEW DRUG CONSORTIUM MEMBERSHIP._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 12 February 1997
Resolved
RENEW FCC SAFETY RADIO CERT. UNTIL RENEWED, VESSEL'S ROUTE IS RESTRICTED TONOT MORE THAN 1000' FROM SHORE._x001C_ _x001C_ _x001C_
Unknown
Issued 6 January 1995
Resolved
Provide proof of drug testing for all persons employed on the vessel.
Engineering
Issued 6 January 1995
Resolved
Label both emergency fuel shut-offs.
Lifesaving
Issued 6 January 1995
Resolved
Provide 1 red flare.
Documentation
Issued 13 June 1991
Resolved
PROVIDE FCC CERTIFICATE PRIOR TO 13JUL91. VESSEL LIMITED TO NOT MORE THAN 1000 FEET FROM SHORE UNTIL COMPLETED.
Documentation
Issued 13 June 1991
Resolved
POST EMERGENCY CHECKOFF LIST (46 CFR 185.25-5) PRIOR TO CARRYING PASSENGERS.
Documentation
Issued 15 June 1989
Resolved
PROVIDE COPY OF FCC RADIOSTATION LICENSE AND RADIOTELEPHONY CERTIFICATE. UNTIL COMPLETED, VESSEL IS LIMITED TO 1000 FEET FROM SHORE.
Casualty record · 1
29 September 2022Routine · role: Involved in a Marine Casualty · activity 7579220
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.