MAURY USCG vessel records Sign in
← All vessels

MISS PARADISE

MISS PARADISE is a 1989 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1989, most recently in January 2024, along with 107 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2022.

Records from 1989 to 2024. Most recent: inspection, 8 January 2024.

Built
1989
Last inspected
8 January 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB9924
327165
Flag
UNITED STATES
366985150 (licence lapsed)
Maury page id
psix-327165

Inspections, by type

…with no type recorded3
Years with a record 33 calendar years (1989–2024)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.0 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS · TARPON SPRINGS, FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portSANIBEL ISLAND, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB9924MMSI 366985150 · expired · compulsorily equipped · granted 9 August 2014, cancelled 28 December 2024
WAE8619MMSI not assigned · expired · compulsorily equipped · granted 1 November 1994, cancelled 30 October 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

8 January 2024 Administrative Inspection · Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7868369
4 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7573639
29 September 2022 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579220
19 May 2022 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7453807
11 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7447652
30 November 2021 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7358731
21 June 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7231308
19 June 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6974644
5 December 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6863627
19 March 2019 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6645189
20 February 2018 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6356334
3 November 2017 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6296126
31 May 2017 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6161351
2 December 2016 Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6043607
8 December 2015 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5783593
21 October 2015 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5734281
26 March 2014 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4818179
7 December 2011 Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4200243
1 March 2010 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3687971
4 February 2009 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3411559
2 April 2008 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3175149
9 May 2007 Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2925321
5 January 2007 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2846056
9 February 2006 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2582155
6 June 2005 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2377192
8 February 2005 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2289146
23 January 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1991265
2 September 2003 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1796440
6 June 2003 Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1809346
12 February 2003 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1744316
22 January 2003 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1733535
5 February 2002 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1490913
7 January 2002 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1477582
15 June 2001 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1471254
7 February 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1057879
12 January 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1413860
8 September 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 822395
14 June 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1437754
29 February 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1046488
20 January 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1408472
12 January 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1464819
17 June 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1470177
14 May 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1125837
1 April 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1454586
31 March 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 218506
25 February 1997 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1411424
12 February 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1357888
17 June 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1442415
12 January 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193056
3 April 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 855720
6 January 1995 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1142874
29 June 1994 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1180632
10 January 1994 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1162327
18 January 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 836283
13 January 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 836157
9 June 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 961387
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1312634
22 August 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308699
19 August 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 941197
13 June 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1000545
18 January 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1222736
13 December 1990 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1211605
13 June 1990 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 927718
28 September 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1304604
28 August 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1342589
15 June 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 893001
15 June 1989 Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1204228

Deficiency record · 107

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022 No resolution recorded
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 May 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull…Upon entering the port hull aft compartment, water and air bubbles entered through the bottom of the hull in way of the keel. Could not determine exact location of damage. Owner to determine the condition of the hull by means of dry dock. At that time a Marine Inspector will attest to any damage and review any repair proposals. Passengers are not permitted until the vessel is deemed sea worthy. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2022
Resolved 15 August 2022
Resolution: Inspected repaired area. No damage to outer hull. See activity 7453807 for details.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Both flashlights did not function. 46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 15 August 2022
Resolution: New flashlights onboard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 May 2022 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented. No records could be found of any drills in the past 03 months. 46 CFR 185.520(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 15 August 2022
Resolution: Drill log reviewed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 May 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts. No charts were onboard. 46 CFR 184.420
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 15 August 2022
Resolution: Charts provided.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 May 2022 Resolved
Placards containing instructions for the donning and use of lifejackets aboard the vessel must be posted. No lifejacket donning placard was available. 46 CFR 185.516
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 15 August 2022
Resolution: Placard provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2022 Resolved
Portable fire extinguishers must be…installed and located to the satisfaction of the OCMI. 2-A extinguisher under the helm was not secured to a bracket and could easily roll out onto the deck. 46 CFR 181.520
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 15 August 2022
Resolution: Extinguisher secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2022 Resolved
The number and identification of the items stowed inside, must be marked in clearly legible letters and numbers. Lifejacket stowage did not show child life jackets and the numbers were faded on all containers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 15 August 2022
Resolution: Stowage marked.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 June 2021 Resolved
FCC Safety Radio Certificate is expired. Vessel restricted to no more than 1,000 feet from shore until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 25 June 2021
Resolution: Received a new certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 June 2021 Resolved
Port side high water alarm is inoperable and electrical wiring is laying in bilge. Prove proper operation and re-wire.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 22 June 2021
Resolution: Received video of working bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2021 Resolved
Provide floating light for ring buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 22 June 2021
Resolution: Received photos of working light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2021 Resolved
Fuel lines are not double clamped.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 22 June 2021
Resolution: Received photos of clamps on lines.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 June 2021 Resolved
Provide chart for navigation area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 22 June 2021
Resolution: Received photo of new chart.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2020 Resolved
Provide new 10-B:C fire extinguisher and mount near operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2020
Resolved 30 July 2020
Resolution: New extinguisher onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 June 2020 Resolved
Prove operation of both bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2020
Resolved 29 July 2020
Resolution: Received photos of new bilge alarms installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2020 Resolved
Provide 07 additional adult life jackets. Passenger count reduced to 42 until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2020
Resolved 30 July 2020
Resolution: New jackets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 June 2020 Resolved
Provide 03 additional red hand flares to replace expired onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2020
Resolved 29 July 2020
Resolution: Received photos of new flares.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 March 2019 Resolved
Vessel missed annual inspection, do not carry passengers until COI renewal is complete. (46CFR176.500)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Completed COI.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 February 2018 Resolved
Replace 60 ft line on life ring and line for light. (46CFR180.70)
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 7 March 2018
Resolution: Purchased new 60 ft line.
Electrical › Electric Supply System (service) › Cable
Issued 20 February 2018 Resolved
Cover spliced wires to both forward navigation lights. (46CFR176.800)
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 7 March 2018
Resolution: Covered wires with elextrical tape.
Construction/Loadline › Structures › Deck Plating
Issued 3 November 2017 Resolved
Repair rotted deck aft of starboard hatch below second stanchion rail. (46CFR176.600)
Action required: 705 - Other - as specified
Resolved 10 November 2017
Resolution: Cut out and replaced old pywood and fiberglass.
Construction/Loadline › Hull › Bottom Plating
Issued 3 November 2017 Resolved
Add new layer of FRP to both hulls for beaching (46CFR176.600)
Action required: 705 - Other - as specified
Resolved 13 November 2017
Resolution: Added FRP layer to both hulls for beaching.
Documentation › Markings/Placards › Warning Signs
Issued 2 December 2016 Resolved
Replace fuel shut-off placards on both tanks.
Action required: 705 - Other - as specified
Due 22 December 2016
Resolved 17 January 2017
Resolution: Stenciled new fuel placards on both tanks.
Engineering › Fuel Oil Service System › Hose
Issued 2 December 2016 Resolved
Put two hose clamps on both fuel lines.
Action required: 705 - Other - as specified
Due 22 December 2016
Resolved 17 January 2017
Resolution: Placed two hose clamps on both fuel lines.
Communications › Audible Communications › Bell
Issued 2 December 2016 Resolved
Replace clapper on bell.
Action required: 705 - Other - as specified
Due 22 December 2016
Resolved 17 January 2017
Resolution: Replaced clapper so bell functions properly.
Fire Fighting › Fire Bucket › Capacity
Issued 2 December 2016 Resolved
Replace fire buckets woith 2.5 gallon buckets or drill 5 gallon buckets to make then 2.5 gallons.
Action required: 705 - Other - as specified
Due 22 December 2016
Resolved 17 January 2017
Resolution: Purcchased three new 2.5 gallon fire buckets.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 December 2015 Resolved
Starboard navigation light was inop, repair / replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2015
Resolved 8 December 2015
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 December 2015 Resolved
Vessel does not have required amount of aspirin in first aid kit. Provide proper amount on board (100).
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 February 2016
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 8 December 2015 Resolved
Provide current MIS report for 2014.
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 February 2016
Stability › Watertight Integrity › General
Issued 8 December 2015 Resolved
Hatch on port side handle has broken handle. Repair / replace hatch.
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 February 2016
Construction/Loadline › Hull › Side Shell
Issued 21 October 2015 Resolved
Repair all areas identified on hull to original.
Action required: 705 - Other - as specified
Resolved 6 November 2015
Resolution: All area repaired to original.
Construction/Loadline › Penetrations › Valve Flange
Issued 21 October 2015 Resolved
Replace overboard valve.
Action required: 705 - Other - as specified
Resolved 6 November 2015
Resolution: Valve replaced with new one.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 26 March 2014 Resolved
Vessels bilge high level alarm located on portside hull is inoperative. Repair or replace. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2014
Resolution: Vessel repaired bilge high level alarm located on portside hull. Conducted operational test, SAT.
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 March 2014 Resolved
Vessels magnetic compass light is inoperative. Repair or replace and show proper operation. 46 CFR 184.402
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 March 2014
Resolution: Vessel replace wiring for the magnetic compass light and showed proper operation. SAT
Navigation › Piloting/Steering › Marine Charts
Issued 26 March 2014 Resolved
Vessel's navigational charts, tides & currents, Navigation Rules, and Coast Pilot for area of operations are out of date. Provide updated charts, tides & currents, Navigation Rules, and Coast Pilot for the area of operations. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2014
Resolved 1 May 2014
Resolution: Vessel provided up to date navigation charts, tides & current tables, Navigation Rules, and Coast Pilot for area of operations.
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 26 March 2014 Resolved
Vessels gas fuel hoses on both fuel tanks leading to fuel filters are deteriorated and cracked. Replace with new hoses on both fuel tanks. 46 CFR 176.25-50
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2014
Resolution: Vessel replaced fuel hoses identified on both fuel tanks leading to fuel filters with new hoses.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 March 2014 Resolved
DAPI audit revealed 3 individuals 2 of which were licensed mariners that were operating when there pre-employment drug/alcohol test had not been fully completed and verified on the consortiums employment roster. Provide proof of complete/proper enrollment/roster of employees (pre-employment) drug/alcohol testing. 46 CFR 16.210
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 March 2014
Resolution: Owner/Operator provided updated consortium employment roster with completed pre-employment testing for all employees currently working for company.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 March 2014 Resolved
Vessel could not produce original Certificate of Inspection for inspection. Local CG will process for renewal of Certificate of Inspection for the Owner/Operator. 46 CFR 176.502
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 May 2014
Resolution: Sector St Pete has submitted through COC for stamp and signature for issuance of new COI.
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 March 2014 Resolved
Vessel does not have emergency fuel shut-off posted for operation of emergency fuel shut-offs in the event of an emergency. Post instructions for emergency fuel shut-offs for both emergency fuel shut-offs. 46 CFR 185..30-20
Action required: 705 - Other - as specified
Due 2 April 2014
Resolved 1 May 2014
Resolution: Vessel installed emergency fuel shut-off plaquereds on both fuel tanks.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 December 2011 Resolved
Passenger count is reduced to 48 until damaged adult lifejacket is replaced IAW 46 CFR 180.71.
Action required: 705 - Other - as specified
Resolved 3 January 2012
Engineering › Gasoline Engine (propulsion) › Oil Pan (4 cycle)
Issued 7 December 2011 Resolved
Prove proper operation of port propulsion engine IAW 46 CFR 182.200.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2012
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 December 2011 Resolved
Conduct man overboard, fire and abandon ship drills IAW 46 CFR 185.520.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2012
Engineering › Gasoline Engine (propulsion) › Piston (4 cycle)
Issued 2 March 2010 Resolved
Start outboard engine and test propulsion and steering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 March 2010 Resolved
Service portable fire extinguisher and mount.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Lifesaving › Lifebuoys › Serviceable
Issued 2 March 2010 Resolved
Replace ring life buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 March 2010 Resolved
Post life jacket donning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 March 2010 Resolved
Replace retro tape on (10) life jackets.
Due 10 March 2010
Resolved 29 March 2010
Navigation › Piloting/Steering › Marine Charts
Issued 2 March 2010 Resolved
Place chart and navigations pubs on vessel.
Due 10 March 2010
Resolved 29 March 2010
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 March 2010 Resolved
Replace damaged aft deck
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 March 2010
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 March 2010 Resolved
Remove wing nuts on battery.
Due 10 March 2010
Resolved 29 March 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 March 2010 Resolved
Replace missing items in first aid kit.
Due 10 March 2010
Resolved 29 March 2010
Lifesaving › Lifebuoys › Serviceable
Issued 5 January 2007 Resolved
Properly place retroreflective tape on ring buoy.
Due 5 January 2007
Resolved 5 January 2007
Resolution: Cleared
Engineering › Bilge Water Management System › Not Operational
Issued 5 January 2007 Resolved
Make permanent repairs to port visual high level bilge alarm.
Action required: 705 - Other - as specified
Due 5 January 2007
Resolved 5 January 2007
Resolution: Cleared
Construction/Loadline › Structures › Deck Plating
Issued 13 February 2006 Resolved
Make repairs to main deck in accordance with the approved repair proposal.
Action required: 705 - Other - as specified
Due 2 March 2006
Resolved 2 March 2006
Resolution: Cleared
Operations/Management › Drills/Instruction › Abandon Ship
Issued 9 February 2006 Resolved
Provide training logbook with detailed description of drills and procedures.
Action required: 705 - Other - as specified
Due 19 February 2006
Resolved 2 March 2006
Resolution: Cleared
Personnel › Training › Fire Fighting Basic
Issued 9 February 2006 Resolved
Provide emergency instruction list I.A.W. 46CFR185.25-5
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 9 February 2006
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 February 2006 Resolved
Provide evidence of proper DAPI training for supervisors and crew.
Action required: 705 - Other - as specified
Due 19 February 2006
Resolved 2 March 2006
Resolution: Cleared
Engineering › Bilge Water Management System › Not Operational
Issued 9 February 2006 Resolved
Make permanent repairs to the STBD bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2006
Resolved 9 February 2006
Construction/Loadline › Structures › Deck Plating
Issued 9 February 2006 Resolved
Submit detailed repair proposals reguarding the soft deck area in way of the STBD aft console and STBD FWD of the lifejacket storage locker.
Action required: 705 - Other - as specified
Due 19 February 2006
Resolved 13 February 2006
Resolution: Received satisfactory repair proposal.
Construction/Loadline › Hull › Bottom Plating
Issued 6 June 2005 Resolved
BUILD UP SACRIFICIAL FRP IN WAY OF PORT AND STARBOARD BOW BOTTOM WHERE BEACHING OF VESSEL IS ERODING THE FIBERGLASS HULL.
Due 30 June 2005
Resolved 14 June 2005
Construction/Loadline › Hull › Collision Strap
Issued 6 June 2005 Resolved
GRIND OUT AND REPAIR FRACTURE IN WAY OF PORT BOW AT MAIN DECK CONNECTION AND PROPERLY REPAIR WITH FRP RESIN/MAT.
Due 30 June 2005
Resolved 14 June 2005
Construction/Loadline › Structures › Manhole
Issued 6 June 2005 Resolved
INSTALL NEW GASKET IN PORT AFT HATCH.
Due 30 June 2005
Resolved 14 June 2005
Engineering › Gasoline Engine (propulsion) › Valve, Reed (2 stroke)
Issued 6 June 2005 Resolved
INSTALL NEW ZINC ANODES IN WAY OF BOTH OUTBOARD ENGINES.
Due 30 June 2005
Resolved 14 June 2005
Documentation › Certificates/Documents › FCC SSL
Issued 8 February 2005 Resolved
Provide valid legible FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 22 February 2005
Resolved 14 June 2005
Navigation › Piloting/Steering › Marine Charts
Issued 8 February 2005 Resolved
Provide current chart for vessel's operating area.
Due 22 February 2005
Resolved 8 February 2005
Lifesaving › Lifebuoys
Issued 23 January 2004 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR BOTH SIDES OF THE RING BOUY.
Due 23 February 2004
Resolved 23 January 2004
Electrical › Electric Supply System (service)
Issued 23 January 2004 Resolved
PROVIDE COVERS AND PROPER NUTS FOR BATTERY CONNECTIONS VICE WING NUTS. LEGACY COMPONENT DESC: Battery Installation
Due 23 February 2004
Resolved 23 January 2004
Construction/Loadline › Hull
Issued 4 June 2003 Resolved
Provide alternating layers of fiberglass mat, Red, yellow, green on FWD sections of hulls due to wearing of mat from vsl beachings. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 6 June 2003
Resolution: Olson''s marine completed work
Construction/Loadline › Structures
Issued 4 June 2003 Resolved
Re-tab first transverse deck support beam STBD FWD hull. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 6 June 2003
Engineering › Bilge Water Management System
Issued 4 June 2003 Resolved
Re-new exterior (mushroom) portion of bilge discharge hose thru-hull fitting at port aft hull. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 6 June 2003
Engineering
Issued 4 June 2003 Resolved
Provide second hose clamp for head intake valve/hose connection.
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 6 June 2003
Electrical › Lighting (emergency)
Issued 22 January 2003 Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 31 January 2003
Electrical › Electrical Distribution System (service)
Issued 22 January 2003 Resolved
PROPERLY SLICE WIRE CONNECTIONS WITH CRIMP TYPE CONNECTORS FOR ALL BILGE PUMPS AND HIGH WATER ALARMS. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 22 January 2003
Electrical › Electrical Distribution System (service)
Issued 22 January 2003 Resolved
REMOVE DEAD END WIRE RUNS FROM STBD HULL LEADING OUT OF STEERING CONSLOE. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 31 January 2003
Personnel › Training
Issued 22 January 2003 Resolved
PROVIDE FIRST AID AND CPR TRAINING FOR AT LEAST 50% OF CREW LEGACY COMPONENT DESC: First Aid/CPR
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 31 January 2003
Resolution: 50% OF CAPT''S AND CREW HAVE BEEN SIGNED UP FOR A CLASS NEXT MONTH
Operations/Management › Drug and Alcohol Testing
Issued 22 January 2003 Resolved
PROVIDE MIS REPORT FOR PREVIOUS YEAR. LEGACY COMPONENT DESC: MIS Submission
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 31 January 2003
Engineering › Fuel Oil Service System
Issued 22 January 2003 Resolved
PROVIDE PLANS FOR NEW FUEL TANK INSTALLATION PRIOR TO 01 FEB03 AS REQUIRED BY INSPECTION CONDUCTED 12JAN01. LEGACY COMPONENT DESC: Portable Fuel System
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 31 January 2003
Resolution: AS PER TAMMS LTR 16710/945807 IN CASE FILE, OWNERS WILL CONTACT THIS OFFICE TO PRESSURE TEST OF FUEL TANKS. ISSUED 835 TO REFELCT TAMMS LTR.
Engineering › Fuel Oil Service System
Issued 22 January 2003 Resolved
OWNERS MUST HYDRO-TEST TANK NLT 7MAR03 TO SHOW COMPLIANCE WITH MSO TAMMS LTR #945807 LEGACY COMPONENT DESC: Tank
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 31 July 2003
Resolution: Rescinded reqmnt as FRP tanks have been filled to the top and have been in service previously on this vessel.
Operations/Management › Drug and Alcohol Testing
Issued 10 January 2002 Resolved
Provide proof of enrollment in drug program. LEGACY COMPONENT DESC: Proof of Enrollment
Action required: 705 - Other - as specified
Due 7 February 2002
Resolved 4 February 2002
Resolution: Employer run. Collection Site & Lab=SBCI
Communications › Alarms/Indicators
Issued 10 January 2002 Resolved
Repair high water bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2002
Resolved 4 February 2002
Operations/Management › Drills/Instruction
Issued 10 January 2002 Resolved
Entered in error. No deficiency.
Due 7 February 2002
Resolved 7 February 2002
Resolution: Duplicate entry as item 4 of this date. Unable to delete duplicate entry.
Engineering › Gasoline Engine (propulsion)
Issued 10 January 2002 Resolved
MAKE REPAIRS TO BOTH PROPULSION ENGINES. WILL RETURN TO CONDUCT SEA TRIALS UPON REPAIRS AND NOTIFICATION FROM OWNER.
Action required: 705 - Other - as specified
Resolved 4 February 2002
Engineering › Fuel Oil Service System › Tank
Issued 12 January 2001 Resolved
PROVIDE PROOF THAT VESSEL IS IN COMPLIANCE WITH 46CFR177.410(b) OR INSTALL GASOLINE FUEL SYSTEM (TANKS) IAW 46CFR177.410(d)(2). EVALUATE SERVICEABILITY OF FIBERGLASS FUEL TANKS CONDITION AT EACH DRYDOCK.
Condition: Unknown
Due 6 June 2005
Resolved 14 June 2005
Electrical
Issued 12 January 2001 Resolved
REMOVE DEAD END WIRING FROM STARBOARD HULL AND UNDER HELM CONSOLE.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Lifesaving
Issued 12 January 2001 Resolved
BRING FIRST AID KIT INTO COMPLIANCE WITH 46CFR160.041.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Fire Fighting
Issued 12 January 2001 Resolved
SEVICE 1 B-I PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Construction/Loadline
Issued 12 January 2001 Resolved
INSTALL CHECK VALVE OR ONE-WAY VALVE ON BOTH PORT AND STARBOARD BILGE PUMP IN AFT COMPARTMENTS.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Construction/Loadline
Issued 14 June 2000 Resolved
MAKE REPAIRS TO PORT AND STARBOARD HULLS ON BOTTOM SHELL FORWARD WHERE WORNFROM BEACH LANDINGS.
Condition: Unknown
Due 30 June 2000
Resolved 30 June 2000
Fire Fighting
Issued 20 January 2000 Resolved
PROVIDE AND INSTALL PROPER BRACKETS FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Electrical
Issued 20 January 2000 Resolved
PROPERLY MOUNT BATTERIES TO PREVENT MOVEMENT.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 20 January 2000 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON RING BUOY AND 3-6 FOOT LANYARD WITH CLIP ON LIGHT.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Documentation
Issued 20 January 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Lifesaving
Issued 20 January 2000 Resolved
REWRITE EMERGENCY INSTRUCTIONS TO MAKE APPLICABLE TO THE VESSEL.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Navigation
Issued 20 January 2000 Resolved
MAKE REPAIRS TO WIRING AND LIGHT FOR MAGNETIC COMPASS.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Navigation
Issued 20 January 2000 Resolved
PROVIED AND POST EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Accommodation/Occupational Safety
Issued 20 January 2000 Resolved
INSTALL ADEQUATE RAILING AT EACH GANGWAY ENTRANCE.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 20 January 2000 Resolved
PROPERLY LABLE LIFEJACKET STOWAGE LOCKERS AND SEPARATE CHILD AND ADULT JACKETS.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 20 January 2000 Resolved
PROVIDE AND POST PFD DONNING PLACARDS FOR BOTH STYLE PFD'S.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 20 January 2000 Resolved
PROVIDE AN APPROVED FIRST AID KIT.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Unknown
Issued 12 February 1997 Resolved
RENEW DRUG CONSORTIUM MEMBERSHIP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 February 1997
Resolved 12 February 1997
Documentation
Issued 12 February 1997 Resolved
RENEW FCC SAFETY RADIO CERT. UNTIL RENEWED, VESSEL'S ROUTE IS RESTRICTED TONOT MORE THAN 1000' FROM SHORE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 February 1997
Resolved 12 February 1997
Unknown
Issued 6 January 1995 Resolved
Provide proof of drug testing for all persons employed on the vessel.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Engineering
Issued 6 January 1995 Resolved
Label both emergency fuel shut-offs.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Lifesaving
Issued 6 January 1995 Resolved
Provide 1 red flare.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Documentation
Issued 13 June 1991 Resolved
PROVIDE FCC CERTIFICATE PRIOR TO 13JUL91. VESSEL LIMITED TO NOT MORE THAN 1000 FEET FROM SHORE UNTIL COMPLETED.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Documentation
Issued 13 June 1991 Resolved
POST EMERGENCY CHECKOFF LIST (46 CFR 185.25-5) PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Documentation
Issued 15 June 1989 Resolved
PROVIDE COPY OF FCC RADIOSTATION LICENSE AND RADIOTELEPHONY CERTIFICATE. UNTIL COMPLETED, VESSEL IS LIMITED TO 1000 FEET FROM SHORE.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989

Casualty record · 1

29 September 2022Routine · role: Involved in a Marine Casualty · activity 7579220
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.