MAURY USCG vessel records Sign in
← All vessels

DELTA'S SPLASH

DELTA'S SPLASH is a 1989 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1989, most recently in September 2025, along with 134 deficiencies and 1 casualty investigation in 2010.

Records from 1989 to 2025. Most recent: inspection, 3 September 2025.

Built
1989
Last inspected
3 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB9749
327375
Flag
UNITED STATES
368394820
Maury page id
psix-327375

Inspections, by type

…with no type recorded3
Years with a record 35 calendar years (1989–2025)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.4 ft × 12.3 ft × 6.1 ft
Registered tonnagegross 18 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOATS INC · CAPE CANAVERAL, FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOYNTON BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 21 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP8932MMSI 368394820 · active · compulsorily equipped · granted 20 November 2024, expires 20 November 2034
WDL4092MMSI 368128020 · cancelled · compulsorily equipped · granted 16 January 2020, cancelled 15 November 2024
WDB9749MMSI 366982050 · expired · compulsorily equipped · granted 7 October 2004, cancelled 13 December 2014
WAE6819MMSI not assigned · expired · compulsorily equipped · granted 31 August 1999, cancelled 1 September 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

3 September 2025 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8207161
2 December 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8049566
20 February 2024 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7867585
17 October 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7810933
6 October 2022 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7572238
8 February 2022 Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7392598
14 September 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7312218
28 August 2020 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7044540
5 February 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6906720
7 October 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6829846
1 October 2018 Examination of Repairs · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6548310
21 February 2018 Spot Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6359274
23 October 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6293412
26 September 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6275061
24 October 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6025661
25 August 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5983046
3 September 2015 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5225137
6 August 2014 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4943560
2 July 2012 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4364811
14 September 2010 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3849405
27 January 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3670746
1 December 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3641551
17 February 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3417234
13 November 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3361777
5 November 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3091746
24 October 2006 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2806039
4 October 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2793612
15 September 2005 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2493073
29 November 2004 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2251060
15 September 2004 Annual Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2196233
13 August 2004 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2165006
12 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2164974
5 November 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1942764
13 November 2002 Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1704620
19 November 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1075912
1 November 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1370397
13 September 2000 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406783
7 September 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375891
4 December 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1468029
18 September 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 798904
19 September 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1112725
4 December 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1092125
18 October 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1158024
19 September 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 825581
6 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 21037
19 July 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1188719
2 November 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 865447
9 August 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1172399
2 August 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 848811
26 October 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952825
8 September 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 935849
24 July 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 951112
27 November 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 943649
23 April 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 912406
5 October 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 931965
28 July 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 930479
24 July 1989 Hull Examination · Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1342802

Deficiency record · 134

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 October 2025 Resolved
On a vessel of at least 26’ in length a visual and audible alarm must be provided at the operating station. None of the high water alarm visual or audible indicators are operational.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2025
Resolution: Tested sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 20 October 2025 Resolved
Marine employers shall establish a program for the chemical testing for dangerous drugs on a random basis of crew members. Vessel was unable to provide list of crew members in the program or alcohol testing devices.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2025
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 October 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is missing 02 life jackets. Vessel only allowed to carried a total of 20 passengers.
Action required: 705 - Other - as specified
Resolved 5 November 2025
Resolution: Provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 October 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Aft and fwd indicators are inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2025
Resolution: Test sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 October 2025 Resolved
A vessel must have a least three 2.5 gallon buckets. Vessel has three 5 gallon buckets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2025
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 October 2025 Resolved
Each ring life buoy with a waterlight must have a lanyard of at least 3 feet but not more than 6 feet. A vessel carrying only one righ buoy, must be attached to the lanyard with a corrossion-resistant clip. Ring Buoy is missing lanyard and corrossion-resistant clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2025
Resolution: installed.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 20 October 2025 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing actions to be taken in the event of fire, heavy weather, or man overboard conditions. Instruction were not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2025
Resolution: Posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2025 Resolved
Provisions must be made for closing all supply duct cowls or scoops for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. No means to close supply ducts are available.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 September 2025 Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. Owner/Operator failed to make vessel available for COI renewal.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2025
Resolution: Complted Inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 September 2025 Resolved
Each Hydrostatic release unit must be marked with an expiration date of two years after the date of which the unit is installed. Hydrostatic released expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2025
Resolution: Replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 December 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Provide Drug and Alcohol Program documentation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2025
Resolved 14 December 2024
Resolution: Vessel provided docs to MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 December 2024 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Replace line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2025
Resolved 14 December 2024
Resolution: Line replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Demostrate proper operation ov navigational lights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 14 December 2024
Resolution: Vessel sent photo of lights working.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 2 December 2024 Resolved
A separate circuit, with overcurrent protection at the main distribution panel, must be provided for each radiotelephone installation. Demonstrate proper operation of radio.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2025
Resolved 14 December 2024
Resolution: Fuse holder replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 December 2024 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Fix port engine tachometer.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 14 December 2024
Resolution: RPM gauge fully operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 December 2024 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. Replace gaskets on hatches.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2025
Resolved 14 December 2024
Resolution: Gasket replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018 Resolved
03 child personal flotation devices unservicable. ***Witnessed replacement of 03 child lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 3 October 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 October 2018 Resolved
Aftermost high water alarm inoperable both audible and visual. Tested bildge pump to ensure proper operation. ***Witnessed audible and visual alarm for aft high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 3 October 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2018 Resolved
Flexible fuel hose section on Stbd. fuel tank top wasted. ***Witnessed replacemnt for fuel hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 3 October 2018
Engineering › Bilge Water Management System › Pump
Issued 2 October 2017 Resolved
Visual auto bilge indicator not operational.
Action required: 705 - Other - as specified
Due 9 October 2017
Resolved 11 October 2017
Resolution: Vessel repaired inop bilge indicator lamp.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 September 2017 Resolved
Stern light inop. COLREGS
Action required: 705 - Other - as specified
Due 9 October 2017
Resolved 11 October 2017
Resolution: Vessel repaired inop stern lamp.
Engineering › Bilge Water Management System › Interface Detector
Issued 24 October 2016 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Lights for the central and forward compartments are inoperable. Repair or replace lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 25 October 2016
Resolution: visual indicators now working properly.
Engineering › Fuel Oil Service System › Valve, Control
Issued 3 September 2015 Resolved
Provide fuel shut off valve handle for void foward of main engines.
Action required: 705 - Other - as specified
Resolved 3 September 2015
Resolution: Vessel operator provided valve handle same day.
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 September 2015 Resolved
Provide clean or replaced battery terminals.
Action required: 705 - Other - as specified
Resolved 7 October 2015
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 September 2015 Resolved
Approve proper operation of mast head nav lights.
Action required: 705 - Other - as specified
Resolved 7 October 2015
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 6 August 2014 Resolved
Work list Item 01: replace port and starboard cutlass bearings prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 7 August 2014
Navigation › Piloting/Steering › Marine Charts
Issued 14 September 2010 Resolved
Provide updated charts, light list, coast pilot, and tide and current tables.
Due 23 September 2010
Resolved 19 November 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 September 2010 Resolved
Replace missing ammonia inhalants for First Aid Kit.
Due 23 September 2010
Resolved 19 November 2010
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 September 2010 Resolved
Remove corrosion from all battery terminals.
Due 23 September 2010
Resolved 19 November 2010
Construction/Loadline › Penetrations › Valve Flange
Issued 14 September 2010 Resolved
Prove proper operation of through hull fitting (ball valve would not turn) for head.
Due 23 September 2010
Resolved 19 November 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2010 Resolved
Replace oxidized lenses for navigation lights (port and stbd).
Due 23 September 2010
Resolved 19 November 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 September 2010 Resolved
Make repairs to broken railing on bow.
Due 23 September 2010
Resolved 19 November 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 December 2009 Resolved
Update first aid kit IAW 46 CFR 160.041
Action required: 705 - Other - as specified
Due 9 December 2009
Resolved 14 December 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 December 2009 Resolved
Provide current editions of US Coast Pilot and CG Light List.
Action required: 705 - Other - as specified
Due 9 December 2009
Resolved 14 December 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 December 2009 Resolved
Make repairs or provide 04 new adult lifejackets.
Action required: 705 - Other - as specified
Due 9 December 2009
Resolved 14 December 2009
Stability › Watertight Integrity › General
Issued 1 December 2009 Resolved
Cap thru hull fitting starboard side aft in engine room.
Action required: 705 - Other - as specified
Due 9 December 2009
Resolved 14 December 2009
Stability › Watertight Integrity › General
Issued 1 December 2009 Resolved
Seal openings in forward and aft engine room bulkheads.
Action required: 705 - Other - as specified
Due 9 December 2009
Resolved 14 December 2009
Accommodation/Occupational Safety › Ventilation › General
Issued 13 November 2008 Resolved
Provide proper vent closure for engine room ventilation on port and starboard side prior to carriage of passengers.
Action required: 705 - Other - as specified
Resolved 18 November 2008
Engineering › Bilge Water Management System › Pump
Issued 13 November 2008 Resolved
Properly secure bilge pump switch cover in engine room.
Action required: 705 - Other - as specified
Due 20 November 2008
Resolved 18 November 2008
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 13 November 2008 Resolved
Repair or replace anchor light.
Action required: 705 - Other - as specified
Due 20 November 2008
Resolved 18 November 2008
Lifesaving › Hand Flares › Quantity
Issued 5 November 2007 Resolved
Provide 06 red and 06 orange hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2007
Resolved 6 November 2007
Resolution: onboard
Engineering › Bilge Water Management System › Interface Detector
Issued 5 November 2007 Resolved
Prove proper operation of bilge high water alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2007
Resolved 6 November 2007
Resolution: onboard,
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 November 2007 Resolved
Seal aft and forward engine room bulkheads.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2007
Resolved 6 November 2007
Resolution: onboard
Navigation › Piloting/Steering › Marine Charts
Issued 5 November 2007 Resolved
Provide current and corrected charts onboard.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 26 November 2007
Resolution: e-mail
Lifesaving › Lifebuoys › Serviceable
Issued 5 November 2007 Resolved
Renew/replace ring life buoy and ensure proper markings and retro reflective tape is applied.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 6 November 2007
Resolution: onboard
Lifesaving › Buoyant Apparatus › Lifeline
Issued 5 November 2007 Resolved
Renew/replace BA painter cage.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 26 November 2007
Resolution: e-mail
Engineering › Fuel Oil Service System › Valve
Issued 5 November 2007 Resolved
Properly label emergency fuel shut off valves.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 26 November 2007
Resolution: e-mail
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 November 2007 Resolved
Submit plans/provide better method of securing the engine room ventilation.
Action required: 705 - Other - as specified
Due 16 November 2007
Resolved 26 November 2007
Resolution: e-mail
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 February 2007 Resolved
Provide original COI onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2007
Resolved 27 February 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 February 2007 Resolved
Mount face plate for duplex electrical outlet in forward compartment.
Due 28 February 2007
Resolved 27 February 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 February 2007 Resolved
Properly mount all water marker lights
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2007
Resolved 27 February 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 22 February 2007 Resolved
Properly mount all fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2007
Resolved 27 February 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 February 2007 Resolved
Mount all vessel placards.
Due 28 February 2007
Resolved 27 February 2007
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 22 February 2007 Resolved
Properly install boarding gate chains.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2007
Resolved 27 February 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 22 February 2007 Resolved
Install cabin lights or remove dead ended wires.
Due 28 February 2007
Resolved 27 February 2007
Engineering › Bilge Water Management System › Pump
Issued 22 February 2007 Resolved
Provide portable bilge pump suction hose that reaches all bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2007
Resolved 27 February 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 22 February 2007 Resolved
Prove proper operation of stbd main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2007
Resolved 27 February 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 February 2007 Resolved
Prove proper operation of anchor light.
Due 28 February 2007
Resolved 27 February 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 February 2007 Resolved
Provide proper lanyards to water marker lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2007
Resolved 27 February 2007
Engineering › Steering Gear System › Rudder Stock
Issued 24 October 2006 Resolved
Provide rudder stops.
Action required: 705 - Other - as specified
Resolved 22 February 2007
Engineering › Steering Gear System › Rudder
Issued 24 October 2006 Resolved
Repair bonding wires aft void.
Action required: 705 - Other - as specified
Resolved 30 January 2007
Construction/Loadline › Hull › Stringer
Issued 24 October 2006 Resolved
Replace rotted frames engine room forward.
Action required: 705 - Other - as specified
Resolved 30 January 2007
Engineering › Bilge Water Management System › Piping
Issued 24 October 2006 Resolved
Secure bilge piping in engine room.
Action required: 705 - Other - as specified
Resolved 27 February 2007
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 24 October 2006 Resolved
Seal bulkhead openings in engine room.
Action required: 705 - Other - as specified
Resolved 27 February 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 October 2006 Resolved
Remove dead ended wires in fuel oil void.
Action required: 705 - Other - as specified
Resolved 30 January 2007
Construction/Loadline › Hull › Stringer
Issued 24 October 2006 Resolved
Replace rotted frame members in fuel oil void aft.
Action required: 705 - Other - as specified
Resolved 29 January 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 24 October 2006 Resolved
Repair/replace water tanks.
Action required: 705 - Other - as specified
Resolved 29 January 2007
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 14 September 2005 Resolved
Provide proper floating electric water marker light, prior to carrying passengers.
Action required: 705 - Other - as specified
Due 28 September 2005
Resolved 4 October 2006
Resolution: Phone
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 September 2005 Resolved
Properly label life jacket storage compartment, size and quantity.
Action required: 705 - Other - as specified
Due 28 September 2005
Resolved 4 October 2006
Resolution: Phone
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 September 2005 Resolved
Provide proper life jacket donning placard.
Action required: 705 - Other - as specified
Due 28 September 2005
Resolved 4 October 2006
Resolution: Phone
Lifesaving › Hand Flares › Expired
Issued 14 September 2005 Resolved
Provide 03 orange smoke flares.
Action required: 705 - Other - as specified
Due 28 September 2005
Resolved 4 October 2006
Construction/Loadline › Penetrations › Valve Flange
Issued 14 September 2005 Resolved
Cap off salt water valve in forward compartment.
Action required: 705 - Other - as specified
Due 28 September 2005
Resolved 4 October 2006
Resolution: Phone
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 September 2005 Resolved
Renew sea water supply hose to the toilet.
Action required: 705 - Other - as specified
Due 28 September 2005
Resolved 4 October 2006
Resolution: Phone
Electrical › Lighting (service) › Lighting Fixture
Issued 14 September 2005 Resolved
Renew or provide light fixture covers for both main deck light fixtures.
Action required: 705 - Other - as specified
Due 28 September 2005
Resolved 4 October 2006
Resolution: Phone
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 14 September 2005 Resolved
Provide required First Aid Kit.
Action required: 705 - Other - as specified
Due 28 September 2005
Resolved 4 October 2006
Resolution: Phone
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 29 November 2004 Resolved
Repair crack to weld on aft step stanchion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 December 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 November 2004 Resolved
Repair all four main handrail stanchions. Severe deterioration in stanchiocns.
Due 16 December 2004
Resolved 16 December 2004
Engineering › Steering Gear System › Rudder Bearing
Issued 29 November 2004 Resolved
Repack both rudder posts.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 16 December 2004
Engineering › Steering Gear System › Ram
Issued 29 November 2004 Resolved
Replace clevis pin on port ram
Due 16 December 2004
Resolved 16 December 2004
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 November 2004 Resolved
Repair or replace both potable water tanks.
Due 31 January 2005
Resolved 14 September 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 November 2004 Resolved
Repair damaged areas to both exhaust pipe at waterline.
Due 16 December 2004
Resolved 16 December 2004
Construction/Loadline › Structures › Deck Plating
Issued 29 November 2004 Resolved
Repair cracks to aft deck.
Due 16 December 2004
Resolved 16 December 2004
Construction/Loadline › Penetrations › Bottom Plug
Issued 29 November 2004 Resolved
Reseal through hole fitting for sewage discharge.
Due 16 December 2004
Resolved 16 December 2004
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 29 November 2004 Resolved
Replace sea valve for AC unit.
Due 16 December 2004
Resolved 16 December 2004
Construction/Loadline › Structures › Machinery Space Opening
Issued 29 November 2004 Resolved
Repair hinge to starboard enginr room deck hatch.
Due 16 December 2004
Resolved 16 December 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2004 Resolved
Numerous improper splices and dead end cable throughout the machinery spaces. Remove or properly terminate dead end cable and ensure all splices are made with the proper connectors or placed in a electrical box. Make Permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the Certificate of Inspection (COI).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 15 September 2004 Resolved
ALL hoses, discharge or suction, to vital systems (Cooling & Exhaust) must have two hose clamps. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2004 Resolved
Battery cable connection corroded and wires broken. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 September 2004 Resolved
Prove proper operation of fixed fire fighting once electrical repairs are complete. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Electrical › Electrical Distribution System (service) › Switch
Issued 15 September 2004 Resolved
Battery switches falling off bulkhead and cables loose. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Construction/Loadline › Penetrations › Valve Flange
Issued 15 September 2004 Resolved
Provide a positive closing valve to all submergible bilge pumps. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2004 Resolved
Large cable coming trough deck in fuel tank space. Remove cable or properly terminate to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2004 Resolved
Exposed, loose wiring and solenoid to head. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2004 Resolved
Wire to bilge pump and submergible pumps spliced w/ electrical tape. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 September 2004 Resolved
Accumulator hanging on cable run. Mount accumulator properly and ensure all cable runs are make to the overhead with metal clips or ties. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 September 2004 Resolved
Breaker panel in console corroded and broken. Make permanent and proper repairs and ensure ALL ELECTRICAL EQUIPMENT is properly wired with circuit protection. Prove proper operation of required equipment once repairs are complete to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Construction/Loadline › Hull › Hull Plating
Issued 15 September 2004 Resolved
Holes in forepeak locker out through the hull, provide proper through hull fittings, repair the holes or, seal the bulkhead leading into cable. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI). If Owner wishes to keep the drains than a new stability test will need to be completed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2004
Resolution: Canceled due to manufactors recommendation.
Engineering › Bilge Water Management System › Interface Detector
Issued 15 September 2004 Resolved
Prove proper operation of the bilge high-level alarms. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04.
Engineering › Freshwater Generation System › Heat Exchanger
Issued 15 September 2004 Resolved
Hot water heater mounts wasted and heater is completely loose. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 15 September 2004 Resolved
Prove proper operations of main propulsion under way, to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Personnel › Training › Familiarization Training
Issued 15 September 2004 Resolved
Prove proper crew drills under way, to the satisfaction of the attending Marine Inspector prior to the re-issuing of the (COI).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2004
Resolution: Cleared on Board, CHK.
Documentation › Certificates/Documents › FCC SSL
Issued 15 September 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2004
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04.
Documentation › Certificates/Documents › FCC SSL
Issued 15 September 2004 Resolved
Provide valid Radio Safety Certificate (expires 05OCT04)
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 October 2004
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 August 2004 Resolved
Vessel removed starboard engine without notifying USCG and then got underway with PAX, COI re-moved from vessel. Vessel must complete a full COI inspection prior to operating with more than 6 PAX
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04 from previous inspection.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 November 2003 Resolved
Conduct annual testing of fixed firefighting system. Provide report on cylinder condition and test of shutdown.
Due 15 November 2003
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04 from previous inspection.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 November 2003 Resolved
Provide log of Man Overboard drills and of training conducted for all emergencies.
Due 5 December 2003
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04 from previous inspection.
Construction/Loadline › Penetrations › Gasket
Issued 5 November 2003 Resolved
Provide a gasket at forward cabin hatch.
Due 15 November 2003
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04 from previous inspection.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 November 2003 Resolved
Repair/replace audible alarm for bilge high water level system.
Due 15 November 2003
Resolved 14 October 2004
Resolution: Cleared on board 14OCT04 from previous inspection.
Navigation › Piloting/Steering
Issued 13 November 2002 Resolved
Magnetic compass light is not working LEGACY COMPONENT DESC: Magnetic Compass
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2002
Resolved 5 December 2002
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 November 2002 Resolved
Vessel did not have required navigation publications
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2002
Engineering › Bilge Water Management System › Pump
Issued 13 November 2002 Resolved
Bilge high level alarms are inoperable
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2002
Operations/Management › Drills/Instruction
Issued 13 November 2002 Resolved
No log book for required drills could be provided
Condition: Improper/Lack of Maintenance
Due 29 November 2002
Resolved 25 November 2002
Lifesaving
Issued 1 November 2001 Resolved
Prior to carriage of passengers, renew hydrostatic release for EPIRB.
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Fire Fighting
Issued 1 November 2001 Resolved
Renew one B-II fire extinguisher.
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Construction/Loadline
Issued 1 November 2001 Resolved
Provide securing device for overboard valve through hull (aft engine).
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Engineering
Issued 1 November 2001 Resolved
Replace fuel oil hose with approved hose (SAE J1942) for port MDE supply.
Condition: Unknown
Due 30 November 2001
Resolved 12 December 2001
Accommodation/Occupational Safety
Issued 1 November 2001 Resolved
Provide lock for MSD overboard discharge.
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Engineering
Issued 1 November 2001 Resolved
Repair leak around retaining nut for port strut.
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Navigation
Issued 1 November 2001 Resolved
Repair inop navigation lights.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Navigation
Issued 1 November 2001 Resolved
Provide navigational publications.
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Engineering
Issued 1 November 2001 Resolved
Repair broken stbd sea strainer.
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Documentation
Issued 1 November 2001 Resolved
Renew radio operator's permit.
Condition: Unknown
Due 1 December 2001
Resolved 25 November 2002
Lifesaving
Issued 1 November 2001 Resolved
Prior to carriage of passengers, renew B/A weak link and painter.
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Construction/Loadline
Issued 1 November 2001 Resolved
Repair inop high water level alarms.
Condition: Unknown
Due 1 November 2001
Resolved 1 November 2001
Construction/Loadline
Issued 1 November 2001 Resolved
Provide means for sealing engineroom compartment for fixed F/F system.
Condition: Unknown
Due 16 November 2001
Resolved 30 November 2001
Construction/Loadline
Issued 1 November 2001 Resolved
Provide latch for aft weathertight hatch.
Condition: Unknown
Due 1 November 2001
Resolved 30 November 2001
Documentation
Issued 1 November 2001 Resolved
Provide simplified stability calculations with new canopy as discussed withCG inspector.
Condition: Unknown
Due 30 November 2001
Resolved 1 November 2001
Engineering
Issued 1 November 2001 Resolved
Replace fuel oil return line on stbd MDE with approved SAE J1942 hose.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Engineering
Issued 1 November 2001 Resolved
Replace exhaust hoses in port & stbd side in steering compartment.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Electrical
Issued 19 September 1996 Resolved
PROVIDE AMP - HERTZ - VOLT GAUGES ON 110 VOLT SYSTEM.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Electrical
Issued 19 September 1996 Resolved
PROVIDE A BATTERY DISCONNECT SWITCH FOR SSDG POSITIVE BATTERY CABLE.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Navigation
Issued 24 July 1989 Resolved
PROVIDE NOTIFICATION TO THE OFFICER-IN-CHARGE, MARINE INSPECTION, MIAMI,FL PRIOR TO OPERATING THE VESSEL IN THE MIAMI, FL ZONE.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Documentation
Issued 24 July 1989 Resolved
PROVIDE A VALID F.C.C. COMMUNICATIONS ACT SAFETY CERTIFICATE, RADIO STATIONLICENSE, AND A COPY OF THE F.C.C. RULES PART 80.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Navigation
Issued 24 July 1989 Resolved
PROVIDE NAVIGATION CHARTS, PUBLICATIONS, AND A COPY OF THE CODE OF FEDERAL REGULATIONS: 46 CFR SUBCHAPTER "T".
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989

Casualty record · 1

29 May 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3761939
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record