Records from 2010 to 2025. Most recent: inspection, 3 September 2025.
Documentation record
Registered dimensions (L × B × D)36.4 ft × 12.3 ft × 6.1 ft
Registered tonnagegross 18 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOATS INC · CAPE CANAVERAL, FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOYNTON BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 21 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
3 September 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8207161
2 December 2024
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8049566
20 February 2024
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7867585
17 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7810933
6 October 2022
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7572238
8 February 2022
Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7392598
14 September 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7312218
28 August 2020
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7044540
5 February 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6906720
7 October 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6829846
1 October 2018
Examination of Repairs · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6548310
21 February 2018
Spot Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6359274
23 October 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6293412
26 September 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6275061
24 October 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6025661
25 August 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5983046
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 October 2025
Resolved
On a vessel of at least 26’ in length a visual and audible alarm must be provided at the operating station. None of the high water alarm visual or audible indicators are operational.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2025
Resolution: Tested sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 20 October 2025
Resolved
Marine employers shall establish a program for the chemical testing for dangerous drugs on a random basis of crew members. Vessel was unable to provide list of crew members in the program or alcohol testing devices.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2025
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 October 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is missing 02 life jackets. Vessel only allowed to carried a total of 20 passengers.
Action required: 705 - Other - as specified
Resolved 5 November 2025
Resolution: Provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 October 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Aft and fwd indicators are inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2025
Resolution: Test sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 October 2025
Resolved
A vessel must have a least three 2.5 gallon buckets. Vessel has three 5 gallon buckets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2025
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 October 2025
Resolved
Each ring life buoy with a waterlight must have a lanyard of at least 3 feet but not more than 6 feet. A vessel carrying only one righ buoy, must be attached to the lanyard with a corrossion-resistant clip. Ring Buoy is missing lanyard and corrossion-resistant clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2025
Resolution: installed.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 20 October 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing actions to be taken in the event of fire, heavy weather, or man overboard conditions. Instruction were not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2025
Resolution: Posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2025
Resolved
Provisions must be made for closing all supply duct cowls or scoops for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. No means to close supply ducts are available.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 September 2025
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. Owner/Operator failed to make vessel available for COI renewal.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2025
Resolution: Complted Inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 September 2025
Resolved
Each Hydrostatic release unit must be marked with an expiration date of two years after the date of which the unit is installed. Hydrostatic released expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2025
Resolution: Replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 December 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels.
Provide Drug and Alcohol Program documentation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2025
Resolved 14 December 2024
Resolution: Vessel provided docs to MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 December 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached.
Replace line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2025
Resolved 14 December 2024
Resolution: Line replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant.
Demostrate proper operation ov navigational lights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 14 December 2024
Resolution: Vessel sent photo of lights working.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 2 December 2024
Resolved
A separate circuit, with overcurrent protection at the main distribution panel, must be provided for each radiotelephone installation.
Demonstrate proper operation of radio.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2025
Resolved 14 December 2024
Resolution: Fuse holder replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 December 2024
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
Fix port engine tachometer.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 14 December 2024
Resolution: RPM gauge fully operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 December 2024
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight.
Replace gaskets on hatches.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2025
Resolved 14 December 2024
Resolution: Gasket replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018
Resolved
03 child personal flotation devices unservicable.
***Witnessed replacement of 03 child lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 3 October 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 October 2018
Resolved
Aftermost high water alarm inoperable both audible and visual. Tested bildge pump to ensure proper operation.
***Witnessed audible and visual alarm for aft high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 3 October 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2018
Resolved
Flexible fuel hose section on Stbd. fuel tank top wasted.
***Witnessed replacemnt for fuel hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 3 October 2018
Engineering › Bilge Water Management System › Pump
Issued 2 October 2017
Resolved
Visual auto bilge indicator not operational.
Action required: 705 - Other - as specified
Due 9 October 2017
Resolved 11 October 2017
Resolution: Vessel repaired inop bilge indicator lamp.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 September 2017
Resolved
Stern light inop. COLREGS
Action required: 705 - Other - as specified
Due 9 October 2017
Resolved 11 October 2017
Resolution: Vessel repaired inop stern lamp.
Engineering › Bilge Water Management System › Interface Detector
Issued 24 October 2016
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Lights for the central and forward compartments are inoperable. Repair or replace lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 25 October 2016
Resolution: visual indicators now working properly.