TOMOLLY is a 1982 passenger vessel (uninspected). The Coast Guard has recorded 17 inspections since 2003, most recently in June 2016, along with 26 deficiencies.

Records from 2003 to 2016. Most recent: inspection, 16 June 2016.

Built
1982
Last inspected
16 June 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-32739

Inspections, by type

Years with a record 11 calendar years (2003–2016)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)32.5 ft × 10.0 ft × 4.3 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWELDCRAFT MARINE · LEWISTON, ID, UNITED STATES · built 1982
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portWHITE BIRD, ID
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 13 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 17

16 June 2016 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6166056
2 June 2016 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5909663
20 April 2016 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5851450
12 May 2014 Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4824398
5 June 2012 COI Inspection · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4278432
3 February 2012 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4237846
16 March 2010 COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3694524
8 April 2009 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3428710
16 April 2008 DAPI Audit
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3185838
2 April 2008 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179353
23 April 2007 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2910764
23 May 2006 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2693179
16 March 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2599759
31 March 2005 COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2290730
11 October 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2272743
21 September 2004 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2021529
10 July 2003 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1756365

Deficiency record · 26

Construction/Loadline › Penetrations › Gasket
Issued 20 April 2016 Resolved
Gasket on port and starboard exterior transom appear to be rotted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 2 June 2016
Resolution: Owner requested extension for drydock to check seals, extension granted.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 20 April 2016 Resolved
Vapor detector wired to key. Vapor detector should be wired to battery to be continuously powered.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 16 June 2016
Resolution: Received email from Operator that all deficiencies issues on 4/20/2016 have been rectified. Special Note added to MISLE for 2017 inspector to pay extra attention to this area.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 April 2016 Resolved
The Fire extinguishers onboard had not undergone an annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 2 June 2016
Resolution: Owner provided reciepts for annual inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2016 Resolved
Battery wired to a solar panel. Installation was not of suitable construction for a marine environment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 16 June 2016
Resolution: Received email from operator stating all deficiencies issued on 4/20/2016 have been rectified. A special note has been added for the 2017 inspector to pay extra attention to these areas.
Stability › Watertight Integrity › General
Issued 12 May 2014 Resolved
during inspection, bow door gasket was found to be wasted. owner/operator was notified to renew gasket prior to the carry of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2014
Resolution: Bow door gasket replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 March 2010 Resolved
Make fire system overide operable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2010
Resolved 10 May 2010
Resolution: Received fax stating fire system had been serviced and override operates normally
Lifesaving › Lifebuoys › Serviceable
Issued 16 March 2010 Resolved
Renew life ring and line.
Action required: 705 - Other - as specified
Due 16 April 2010
Resolved 10 May 2010
Resolution: Received fax stating that the life ring had been replaced.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 23 April 2007 Resolved
Provide 4 missing lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2007
Resolved 3 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 April 2007 Resolved
Provide missing float light for the lifebuoy.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 3 May 2007
Construction/Loadline › Hull › Weld
Issued 23 April 2007 Resolved
Make repairs to the 9 cracked welds on marked bottom frames.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 3 May 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 March 2006 Resolved
Correct labling on the follwoing; change life jacket county from 22 to 23 and correct Document #.
Due 30 April 2006
Resolved 23 May 2006
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 March 2006 Resolved
Provide 4 additional adult life jackets.
Due 30 April 2006
Resolved 23 May 2006
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 March 2006 Resolved
Replace expired eye wash and asprin in first aid kit.
Due 30 April 2006
Resolved 17 March 2006
Resolution: Expired items replaced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 March 2006 Resolved
Provide current Certificate of Documentation.
Due 30 April 2006
Resolved 23 May 2006
Resolution: Corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 March 2006 Resolved
Make port and Stbd. fuel shutoff cables and valves operable.
Due 30 April 2006
Resolved 23 May 2006
Resolution: Corrected
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 16 March 2006 Resolved
Replace missing flame screen (30x30) mesh on port side drip pan.
Due 30 April 2006
Resolved 17 March 2006
Resolution: Flame screen replaced.
Fire Fighting › Fire Bucket › Availability
Issued 16 March 2006 Resolved
Provide 2.5 Gallon fire bucket.
Due 30 April 2006
Resolved 17 March 2006
Resolution: New fire bucket provided.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 16 March 2006 Resolved
Provide 2 portable lights.
Due 30 April 2006
Resolved 17 March 2006
Resolution: Two lights provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 March 2005 Resolved
Prove proper operation of navigation lights. (Colregs & 46 CFR 183.420)
Due 1 May 2005
Resolved 17 May 2005
Resolution: Navigation lights repaired and operational.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 21 September 2004 Resolved
Install engine shutdowns for "FIREBOY" fixed fire fighting system, so when the bottle discharges the engines shut down/ or install a heat detector near the halon bottle, that is set to alarm (go off) at 165f or lower. 46 CFR 181.420
Condition: Unknown
Due 21 October 2004
Resolved 11 October 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 September 2004 Resolved
Provide/replace the ring life buoy lifeline. Complete prior to the carriage of passengers. 46 CFR 180.70(c).
Condition: Improper/Lack of Maintenance
Due 21 October 2004
Resolved 11 October 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 July 2003 Resolved
Provide (1) child sized life preserver. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 18 July 2003
Resolution: Received confirmation from owner''''s rep that (1) child sized preserver was installed onboard vsl.
Lifesaving › Lifejacket/PFD (General)
Issued 10 July 2003 Resolved
Provide and mount a lifejacket donning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 18 July 2003
Resolution: Received digital photo of placard installed onboard the vessel.
Engineering › Gasoline Engine (propulsion)
Issued 10 July 2003 Resolved
Install a new flammable vapor detector in engine compartment and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 11 July 2003
Resolution: Verified installation of new sensor and witnessed satisfactory operational test.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 10 July 2003 Resolved
Make all penetrations to engine compartment vapor tight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 11 July 2003
Resolution: Verified all engine compartment penetrations were vapor tight.
Construction/Loadline › Hull › Side Shell
Issued 10 July 2003 Resolved
Make permanent repairs to various cracks to hull, ramp, and starboard rail cap gusset at bow ramp as marked.
Condition: Unknown
Due 20 August 2003
Resolved 18 July 2003
Resolution: Owner''s rep provided digital photos of completed repairs to hull cracks.

Ownership record