Records from 2003 to 2016. Most recent: inspection, 16 June 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
16 June 2016
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6166056
2 June 2016
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5909663
20 April 2016
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5851450
12 May 2014
Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4824398
5 June 2012
COI Inspection · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4278432
3 February 2012
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4237846
16 March 2010
COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3694524
8 April 2009
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3428710
16 April 2008
DAPI Audit
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3185838
2 April 2008
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179353
23 April 2007
Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2910764
23 May 2006
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2693179
16 March 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2599759
31 March 2005
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2290730
11 October 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2272743
21 September 2004
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2021529
10 July 2003
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1756365
Construction/Loadline › Penetrations › Gasket
Issued 20 April 2016
Resolved
Gasket on port and starboard exterior transom appear to be rotted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 2 June 2016
Resolution: Owner requested extension for drydock to check seals, extension granted.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 20 April 2016
Resolved
Vapor detector wired to key. Vapor detector should be wired to battery to be continuously powered.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 16 June 2016
Resolution: Received email from Operator that all deficiencies issues on 4/20/2016 have been rectified. Special Note added to MISLE for 2017 inspector to pay extra attention to this area.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 April 2016
Resolved
The Fire extinguishers onboard had not undergone an annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 2 June 2016
Resolution: Owner provided reciepts for annual inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2016
Resolved
Battery wired to a solar panel. Installation was not of suitable construction for a marine environment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 16 June 2016
Resolution: Received email from operator stating all deficiencies issued on 4/20/2016 have been rectified. A special note has been added for the 2017 inspector to pay extra attention to these areas.
Stability › Watertight Integrity › General
Issued 12 May 2014
Resolved
during inspection, bow door gasket was found to be wasted. owner/operator was notified to renew gasket prior to the carry of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2014
Resolution: Bow door gasket replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 March 2010
Resolved
Make fire system overide operable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2010
Resolved 10 May 2010
Resolution: Received fax stating fire system had been serviced and override operates normally
Lifesaving › Lifebuoys › Serviceable
Issued 16 March 2010
Resolved
Renew life ring and line.
Action required: 705 - Other - as specified
Due 16 April 2010
Resolved 10 May 2010
Resolution: Received fax stating that the life ring had been replaced.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 23 April 2007
Resolved
Provide 4 missing lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2007
Resolved 3 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 April 2007
Resolved
Provide missing float light for the lifebuoy.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 3 May 2007
Construction/Loadline › Hull › Weld
Issued 23 April 2007
Resolved
Make repairs to the 9 cracked welds on marked bottom frames.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 3 May 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 March 2006
Resolved
Correct labling on the follwoing; change life jacket county from 22 to 23 and correct Document #.
Due 30 April 2006
Resolved 23 May 2006
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 March 2006
Resolved
Provide 4 additional adult life jackets.
Due 30 April 2006
Resolved 23 May 2006
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 March 2006
Resolved
Replace expired eye wash and asprin in first aid kit.
Due 30 April 2006
Resolved 17 March 2006
Resolution: Expired items replaced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 March 2006
Resolved
Provide current Certificate of Documentation.
Due 30 April 2006
Resolved 23 May 2006
Resolution: Corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 March 2006
Resolved
Make port and Stbd. fuel shutoff cables and valves operable.
Due 30 April 2006
Resolved 23 May 2006
Resolution: Corrected
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 16 March 2006
Resolved
Replace missing flame screen (30x30) mesh on port side drip pan.
Due 30 April 2006
Resolved 17 March 2006
Resolution: Flame screen replaced.
Fire Fighting › Fire Bucket › Availability
Issued 16 March 2006
Resolved
Provide 2.5 Gallon fire bucket.
Due 30 April 2006
Resolved 17 March 2006
Resolution: New fire bucket provided.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 16 March 2006
Resolved
Provide 2 portable lights.
Due 30 April 2006
Resolved 17 March 2006
Resolution: Two lights provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 March 2005
Resolved
Prove proper operation of navigation lights. (Colregs & 46 CFR 183.420)
Due 1 May 2005
Resolved 17 May 2005
Resolution: Navigation lights repaired and operational.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 21 September 2004
Resolved
Install engine shutdowns for "FIREBOY" fixed fire fighting system, so when the bottle discharges the engines shut down/ or install a heat detector near the halon bottle, that is set to alarm (go off) at 165f or lower. 46 CFR 181.420
Condition: Unknown
Due 21 October 2004
Resolved 11 October 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 September 2004
Resolved
Provide/replace the ring life buoy lifeline. Complete prior to the carriage of passengers. 46 CFR 180.70(c).
Condition: Improper/Lack of Maintenance
Due 21 October 2004
Resolved 11 October 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 July 2003
Resolved
Provide (1) child sized life preserver. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 18 July 2003
Resolution: Received confirmation from owner''''s rep that (1) child sized preserver was installed onboard vsl.
Lifesaving › Lifejacket/PFD (General)
Issued 10 July 2003
Resolved
Provide and mount a lifejacket donning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 18 July 2003
Resolution: Received digital photo of placard installed onboard the vessel.
Engineering › Gasoline Engine (propulsion)
Issued 10 July 2003
Resolved
Install a new flammable vapor detector in engine compartment and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 11 July 2003
Resolution: Verified installation of new sensor and witnessed satisfactory operational test.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 10 July 2003
Resolved
Make all penetrations to engine compartment vapor tight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 11 July 2003
Resolution: Verified all engine compartment penetrations were vapor tight.
Construction/Loadline › Hull › Side Shell
Issued 10 July 2003
Resolved
Make permanent repairs to various cracks to hull, ramp, and starboard rail cap gusset at bow ramp as marked.
Condition: Unknown
Due 20 August 2003
Resolved 18 July 2003
Resolution: Owner''s rep provided digital photos of completed repairs to hull cracks.