MAURY USCG vessel records
← All vessels

DOUBLE SUNSHINE

Built
1989
Last inspected
8 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF3069
327473
Flag
UNITED STATES
Maury page id
psix-327473

Documentation record

Registered dimensions (L × B × D)44.5 ft × 17.7 ft × 5.7 ft
Registered tonnagegross 16 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBELLECRAFT IND'S CORP · NAPLES, FL, UNITED STATES · built 1989
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portSOUTH PADRE ISLAND, TX
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 11 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

8 April 2026 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8343451
8 September 2025 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8229294
21 April 2025 Deficiency Check · In-Service Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8116947
11 September 2024 Drydock Exam · In-Service Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7997930
6 August 2024 In-Service Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7975418
9 April 2024 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7882410
7 September 2023 Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7765894
11 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7686042
26 September 2022 Damage Survey · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7579515
11 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7448540
19 November 2021 Drydock Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7354147
12 October 2021 Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7352446
7 April 2021 COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7174378
7 April 2020 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6974063
13 October 2019 Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6846418
15 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6663513
6 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6387975
17 October 2017 Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6289480
11 April 2017 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6122336
29 October 2016 Damage Survey
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6033049
5 April 2016 COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5843565

Deficiency record · 28

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2026 Resolved
At each initial inspection for certification of a vessel the owner or operator shall have the vessel ready for inspection all machinery essential to the routine operation of the vessel. MI found the starboard MDE emergency fuel shut off valve not functional. Repair within 7 days. 46 CFR 176.804 (c)
Action required: 705 - Other - as specified
Resolved 15 April 2026
Resolution: MI reviewed video of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2026 Resolved
During a fire in the engine room causality the vessel will cut off air supply by closing ventilators. MI found in the port and stbd engine room ventilation duct without functional engine room dampeners. Repair within 14 days. 46 CFR 185.25-5 (c)
Action required: 705 - Other - as specified
Resolved 22 April 2026
Resolution: MI received proof of def rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 April 2026 Resolved
A vessel must carry one floating water light approved in accordance with § 161.010 in subchapter Q of this chapter attached to the ring life buoy. MI found the float light extinguished. 46 CFR 180.70 (d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 1 May 2026
Resolution: MI reviewed video proof of new FL installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2026 Resolved
The discharge ends of the vent pipes shall be fitted with removable flame screens or flame arrestor’s. Fuel vent flame screen was missing on the stbd side tank vent. 46 CFR 182.15-35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 15 April 2026
Resolution: MI reviewed photo of repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2026 Resolved
Employers are responsible for all the actions of their officials, representatives, and agents in carrying out the requirements of this part. Vessel representatives have an updated DAPI program MIS report and crew list during the inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 22 April 2026
Resolution: MI received proof of def rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2025 Resolved
Replace two through hull valves. Repair prior to credit DD.
Action required: 705 - Other - as specified
Due 20 October 2025
Resolved 20 October 2025
Resolution: MI inspected new valves. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2025 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Vessel crew was unable to check expiration date of life ring buoy light battery. Check and replace if expired. 46CFR176.808(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 12 June 2025
Resolution: Vessel POC submitted evidence of new battery. MI reviewed and identified no defs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI found life ring buoy grab line, lifeline, and water light lanyard to be deteriorated. Replace. 46CFR176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2025
Resolution: POC sent proof of deficiency rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters. MI observed no label. Label. 46CFR185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2025
Resolution: POC sent proof of deficiency rectification.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 30 April 2025 Resolved
On a vessel on which the number of passengers permitted on upper dicks is limited by stability criteria, the maximum number of passengers allowed on an upper dick must be indicated by 1" numbers and letters at the entranceway to that deck. MI observed no such marking. Mark appropriately. 46CFR185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2025
Resolution: POC sent proof of deficiency rectification.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 11 September 2024 Resolved
The intent of this part is to ensure that the scantlings, materials, fastenings, workmanship in arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. During drydock repairs found pitting underneath hollow side plate longitudinals due to build up of moisture that is trapped. Vessel provided repair proposal to crop out 10' and 12' side shell plating fwd of E/R to be done next drydock. Vessel required to complete repair prior to 01OCT25. 46 CFR 177.01-5
Action required: 705 - Other - as specified
Due 1 October 2025
Resolved 3 November 2025
Resolution: Vessel completed all repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2024 Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, shall be completed to the satisfaction of the cognizant [name withheld] found unauthorized electrical equipment installed on the vessel. The vessel shall submit electrical repair plans to MSC for approval or remove unapproved equipment. 46 CFR 183.115 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2024
Resolution: Vessel removed unauthorized electrical equipment.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 September 2023 Resolved
Stbd void 1 & 2, bilge rakes & bilge flats (horizontals) from stem to WTBH 2 - crop and renew. Vessel required to complete repair prior to 31OCT24.
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 22 April 2024
Resolution: See def #7 for the resolution of this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 September 2023 Resolved
The intent of this part is to ensure that the scantlings, materials, fastenings, workmanship in arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Stbd void 1 & 2, bilge rakes & bilge flats (horizontals) from stem to WTBH 2 - crop and renew. Port void 1, bilge rakes, from stem to watertight bulkhead (WTBH) 5 - crop and renew. Waisted engine room frames port and stbd shall be cropped and renewed. Vessel required to complete repair prior to 31OCT24. 46 CFR 177.01-5
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 11 September 2024
Resolution: Vessel was hauled out for drydock/hull exam. Completed repairs with Marine Inspector attendance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2022 Resolved
All vessels shall be provided with bilge pumps in accordance with table 182.25-10(a). Starboard machinery space bilge pump is inoperable. 46 CFR 182.25-10(a) Old-T
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 25 April 2022
Resolution: New bilge pump installed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2022 Resolved
All vessels be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards of an emergency nature which might endanger the vessel and the persons being transported. Vessels starboard shaft seal is leaking excessively resulting in flooding of the machinery space. 46 CFR 185.01-5(a) Old-T
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 April 2022
Resolution: Engine was realigned and new shaft seal was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 April 2022 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Starboard side main weather deck midrail broken. 46 CFR 177.35-1(a) Old-T
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2022
Resolution: Rail fixed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 7 April 2021 Resolved
Non metallic piping found adjacent to through hull fittings (numerous) and before metallic shutoff valve. Old "T" site 46 CFR - Ch 1, 182.40-1 (a)(1)(ii)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 20 April 2021
Resolution: removed non matalic piping
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2021 Resolved
Replace fuel line return house on starboard engine. Old "T" site 46CFR - Ch 1, 182.20-40
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 20 April 2021
Resolution: replaced fuel line
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 April 2021 Resolved
Starboard fuel level sending unit wiring needs replaced. Old "T" site 46CFR - Ch 1, 183.01-15 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 20 April 2021
Resolution: replaced
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 April 2021 Resolved
Monitor #3 void interior hull for water ingress daily prior to taking on passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2021
Resolved 20 April 2021
Resolution: vsl had corrosion in deck plating. Applied temp repair monitor till dry dock
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 April 2021 Resolved
Port main engine throttle cable needs replaced. Old "T" site 46CFR - Ch 1, 182.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 20 April 2021
Resolution: replaced
Engineering › Bilge Water Management System › Pump
Issued 6 April 2018 Resolved
bilge pump starboard number one does not work
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2018
Resolved 6 April 2018
Resolution: replaced and tested
Engineering › Bilge Water Management System › Pump
Issued 11 April 2017 Resolved
2 float switches were non operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 11 April 2017
Resolution: Both float switches replaced and working as intended.
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 April 2017 Resolved
Port and starboard rudder post hoses need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 17 October 2017
Engineering › Steering Gear System › Rudder Stock
Issued 11 April 2017 Resolved
Port side mounting bracket for steering needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 17 October 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 April 2017 Resolved
FCC Safety Radiotelephony Certificate is expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 17 October 2017
Construction/Loadline › Hull › Bottom Plating
Issued 29 October 2016 Resolved
Wastage/pinholes under starboard MDE
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 October 2016
Resolved 29 October 2016
Resolution: Replaced and test two 18"x24" peices of bottom plate and wittnessed sat testing.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.