KATHERINE

KATHERINE is a 1989 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1989, most recently in May 2026, along with 57 deficiencies and 3 casualty investigations between 2007 and 2022.

Records from 1989 to 2026. Most recent: inspection, 19 May 2026.

Built
1989
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2401
327631
Flag
UNITED STATES
367114830
Maury page id
psix-327631

Inspections, by type

…with no type recorded3
Years with a record 34 calendar years (1989–2026)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 14.0 ft × 4.7 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNORTH END MARIN & FRP ENG · ROCKLAND, ME, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portJAMESTOWN, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD2401MMSI 367114830 · active · compulsorily equipped · granted 26 May 2026, expires 16 May 2036
WDA9530MMSI 366866210 · expired · compulsorily equipped · granted 20 August 2002, cancelled 20 October 2012
WAA6449MMSI not assigned · expired · compulsorily equipped · granted 28 March 1994, cancelled 15 August 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

19 May 2026 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8376698
24 March 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8331099
14 April 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8093180
30 April 2024 Administrative Inspection · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7895441
18 March 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7874458
15 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7633389
25 July 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7556914
16 May 2022 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7413380
1 March 2022 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7388346
14 May 2021 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7196906
15 May 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6948428
10 February 2020 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6899609
16 May 2019 DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6675252
27 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6524189
1 May 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6393507
12 February 2018 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6349626
8 May 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6132162
17 May 2016 Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5869522
8 March 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5824604
4 June 2012 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4308657
27 September 2011 Simplified Stability Test
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4159882
12 July 2011 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4064079
11 March 2010 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3674808
17 November 2008 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3364497
21 July 2008 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3274768
17 July 2008 Re-Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3199389
31 March 2008 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3167646
5 September 2007 Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3050065
1 September 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3050066
18 June 2007 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2947861
22 May 2006 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2641672
28 March 2006 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2612777
1 August 2005 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2448594
23 June 2004 COI Inspection · Deficiency Check
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2108267
27 April 2004 Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2055080
6 August 2003 Deficiency Check · Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1867426
4 September 2002 Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1671616
25 April 2002 Administrative Inspection · Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1626093
3 May 2001 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1456006
10 September 2000 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 822197
26 June 2000 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1456858
25 April 2000 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 816826
7 June 1999 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 804932
7 May 1998 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1434747
27 April 1998 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 789851
9 June 1997 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1404433
20 June 1996 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1383297
11 April 1996 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1439715
16 May 1995 Drydock Extension · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1377394
19 May 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 860291
12 May 1993 MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 845692
9 November 1992 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1262481
19 May 1992 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1264536
8 May 1991 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 924205
22 April 1991 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 926483
15 May 1990 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1242744
2 June 1989 Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1352532

Deficiency record · 57

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The retroreflective tape was worn on at least 20 adult lifejackets, needing replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 3 May 2024
Resolution: Retroreflective tape has been placed on all identified adult lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2024 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. The battery for the floating waterlight was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 3 May 2024
Resolution: A new battery has been placed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 April 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Provide up to date charts of the area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 28 May 2024
Resolution: Charts have been updated with local NTM
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 30 April 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions IAW 185.512. Instructions for rough weather at sea missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 24 May 2024
Resolution: Instructions posted at the helm.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2024 Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The markings required may be made by the use of any means and materials which result in durable markings, must be made in clearly legible letters of the Latin alphabet or Arabic or Roman numerals not less than four inches in height. The name of the vessel is missing on the port and starboard bow.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2024
Resolved 24 May 2024
Resolution: Port and starboard bow marked.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 May 2023 Resolved
The use of twist-on type wire nuts is permitted under the following conditions: 1. Connections are made within and enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. 2. Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Remove tape from wiring in vessel head space and determine if proper connections have been made.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 May 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. No visual light to indicate alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 20 May 2022
Resolution: High water alarm visual repaired
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 May 2022 Resolved
A vessel must carry adequate and up to date charts for their area of operation. No updated charts onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 20 May 2022
Resolution: Charts updated
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 May 2022 Resolved
A marine employer must ensure alcohol testing can be conducted within 2 hours of an occurance of a serious marine incident. Alcohol swabs are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 20 May 2022
Resolution: New alcohol swabs obtained
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 16 May 2022 Resolved
A manned U.S. ship that is 26ft or more in length shall ensure one or more garbage placards are displayed in locations that can be seen by crew and passengers. No garbage placard onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 16 May 2022
Resolution: Obtained a garbage placard for the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2021 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length but not more than 6 feet. Vessel lanyard is less than 3 feet in length.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 May 2021
Resolution: Vessel put a new lanyard on the ring life buoy of the correct length.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is broadcasting: No Call Sign.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2018
Resolved 29 November 2018
Resolution: Call sign updated no error displayed in VIVS.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 May 2016 Resolved
Repair/ replace bilge high water alarm and prove proper operation to the attending marine inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2016
Resolution: Repaired existing installation.
Communications › Audible Communications › Bell
Issued 17 May 2016 Resolved
Aquired 8" bell IAW rule 33 inland nav rules.
Condition: Placed in Improper Service
Due 31 May 2016
Resolved 19 May 2016
Resolution: Aquired new bell.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 May 2016 Resolved
Provide closures in aft openings in railings to maintain hight of railing at opening.
Condition: Design Flaw
Due 31 May 2016
Resolved 19 May 2016
Resolution: Installed new railings in aft openings.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 June 2012 Resolved
Prove proper operation of bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2012
Resolved 6 June 2012
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 June 2012 Resolved
Provide current COD
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 8 June 2012
Personnel › Certificates/Documents/Licenses › License, Master
Issued 4 June 2012 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2012
Resolved 4 June 2012
Resolution: Another master for the company was contacted and completed the inspection.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 4 June 2012 Resolved
Master operated the vessel with passengers with an expired license.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2012
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 12 July 2011 Resolved
Provide proof pressure vessel complies with ASME standards and install a relief valve.
Action required: 705 - Other - as specified
Due 26 July 2011
Resolved 31 August 2011
Resolution: A new ASME approved pressure vessel was installed.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 November 2008 Resolved
Prior to carrying passengers, vessel must be made available for inspection. Re-install seating fixed, lifejackets, and overhead canopy as certificated.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2008
Resolved 29 June 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 July 2008 Resolved
All pages of COI must be posted under glass
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Documentation › Certificates/Documents › Stability Letter
Issued 17 July 2008 Resolved
All pages of the stability letter must be posted under glass
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 July 2008 Resolved
Repair/replace cracked elbow joints and mounts on the Port & Stbd deck rails.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 July 2008 Resolved
Provide unexpired battery for floating waterlight
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 July 2008 Resolved
Provide required retro-flective material as required
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 17 July 2008 Resolved
Properly bond and ground independent fuel tank
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Engineering › Fuel Oil Service System › Vent Pipe
Issued 17 July 2008 Resolved
Remove paint from required flame screen
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Engineering › Shafting/Propeller Arrangements › Shaft Cone
Issued 17 July 2008 Resolved
Tightening / repair leak from shaft packing
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Communications › Alarms/Indicators › High Water Alarm
Issued 17 July 2008 Resolved
Repair req. audible high water alarm
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 17 July 2008 Resolved
Properly fix all required seating to the deck
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2008
Resolved 31 July 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 July 2008 Resolved
Abandon ship, man overboard and fire drill must be conducted and logged
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 17 July 2008 Resolved
The vessel was operated with passengers on board without a current credited dry dock exam as required as required per the terms of the Certificate of Inspection.
Due 17 July 2008
Resolved 17 July 2008
Resolution: This deficiency was brought to the attention of the operator and the operator was educated on this requirement. A Notice of Violation was issued for the violation.
Construction/Loadline › Hull › Side Shell
Issued 5 September 2007 Resolved
Conduct dry-dock survey by CG Marine Inspector to include starboard bow involved in collision.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2007
Resolution: Inspected repair of hole in hull on starboard side of bow and completed satisfactory hose test.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 June 2007 Resolved
Install approved bracket for portable fire extinguisher.
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 9 July 2007
Resolution: Witnessed fire extinguisher installed with appropriate bracket.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 June 2007 Resolved
Provide label for quantity of life preservers stowed in pilot house.
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 9 July 2007
Resolution: Witnessed proper stowage labeling for life preservers in pilot house.
Engineering › Fuel Oil Service System › Valve, Control
Issued 18 June 2007 Resolved
Provide labels for fuel shutoff valves.
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 9 July 2007
Resolution: Witnessed proper labeling for fuel shutoff valves.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 June 2007 Resolved
Install Emergency Broadcast Placard.
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 9 July 2007
Resolution: Witnessed properly installed emergency broadcast placard near radio in pilot house.
Engineering › Bilge Water Management System › Not Installed
Issued 18 June 2007 Resolved
Provide high level alarm for bilge system as per 46 CFR 182.530
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 25 July 2007
Resolution: Installed and satisfactorly tested high level alarm for bilge system.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 1 August 2005 Resolved
PROVIDE CPR/1ST AID CERTIFICATION FOR %50 OF CREW
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 31 August 2005
Resolution: CPR/1ST AID TRAINING CONDUCTED
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 August 2005 Resolved
REMOVE HYDRAULIC FLUID FROM BILGES
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 31 August 2005
Resolution: HYRAULIC FLUID REMOVED FROM BILGES
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 August 2005 Resolved
PROVIDE (2) FLASHLIGHTS
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 1 August 2005
Resolution: FLASHLIGHTS PROVIDED
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 June 2004 Resolved
Post the new Certificate of Documentation.
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 15 July 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 23 June 2004 Resolved
Replace Racor fuel filter plasitc drain valve with metallic drain valve and plug.
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 15 July 2004
Fire Fighting › Ventilation Systems › Ducts
Issued 23 June 2004 Resolved
Provide engine room ventilation closures.
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 15 July 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 June 2004 Resolved
Separate child size and adult size life jackets.
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 15 July 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 August 2003 Resolved
CONDUCT 6YR MAINTENANCE ON B-II DRY-CHEMICAL PORTABLE FIRE EXTINGUISHERS IAW NFPA-10.
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 13 August 2003
Resolution: O/O CONTACTED SERVICING AGENCY TO DETERMINE WHY THIS WAS NOT DONE DURING THE ANNUAL SERVICING. THEY WERE EMBARRASSED THAT THEY DID NOT CATCH THIS. LOANER EXTINGUISHERS ARE ON THE VESSEL UNTIL THE ORIGINALS ARE SERVICED AND REPLACED.
Construction/Loadline › Structures
Issued 6 August 2003 Resolved
REPAIR/REPLACE GASKET ON SHAFT-ALLEY DECK COVER.
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 13 August 2003
Engineering › Bilge Water Management System › Interface Detector
Issued 6 August 2003 Resolved
PROVIDE VISIBLE INDICATOR FOR BILGE HIGH-LEVEL ALARM AT OPERATOR'S STATION.
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 13 August 2003
Communications › Alarms/Indicators
Issued 4 September 2002 Resolved
Install high bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 17 September 2002
Resolution: per phone-con with [name withheld]
Fire Fighting
Issued 3 May 2001 Resolved
RECHARGE VESSEL'S FIXED FIREFIGHTING SYSTEM.
Condition: Unknown
Due 14 May 2001
Resolved 27 June 2001
Lifesaving
Issued 3 May 2001 Resolved
CONDUCT MAN-OVERBOARD AND FIRE DRILLS.
Condition: Unknown
Due 14 May 2001
Resolved 27 June 2001
Electrical
Issued 3 May 2001 Resolved
PROVIDE METAL WIRE SUPPORTS FOR VESSEL WIRING AT LEAST EVERY 24 INCHES.
Condition: Unknown
Due 14 May 2001
Resolved 27 June 2001
Engineering
Issued 3 May 2001 Resolved
RE-FASTEN WOODEN BRACKETS FOR VESSEL EXHAUST SYSTEM.
Condition: Unknown
Due 14 May 2001
Resolved 27 June 2001
Lifesaving
Issued 3 May 2001 Resolved
PROVIDE RED CROSS FIRST AID/CPR CARDS FOR 50% OF CREW.
Condition: Unknown
Due 14 May 2001
Resolved 27 June 2001
Navigation
Issued 26 June 2000 Resolved
Provide navigation pubs per 46 CFR 184.420.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Engineering
Issued 11 April 1996 Resolved
PROPERLY LABEL THE REMOTE FUEL SHUTOFF STATION WITH 1 INCH LETTERS AS PER 46CFR185.608.
Condition: Unknown
Due 11 April 1996
Resolved 12 April 1996

Casualty record · 3

1 September 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3050066
21 June 2013Routine · role: Involved in a Marine Casualty · activity 4637998
25 July 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7556914
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.