Documentation record
Registered dimensions (L × B × D)39.1 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 22 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL MARINE INC · PENSACOLA, FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 3 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 21 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 21
9 February 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8295990
13 January 2026
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8296002
6 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8108646
9 May 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7909560
26 January 2024
Drydock Extension · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7856338
28 May 2023
Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 7759262
3 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7679765
14 March 2023
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7655078
12 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7429370
28 December 2021
Drydock Exam · Deficiency Check · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7401385
11 March 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7122752
9 October 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7074676
5 October 2020
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7071756
14 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6939018
30 December 2019
Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6883325
2 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6654384
8 March 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6368455
29 January 2018
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6345825
8 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6141996
17 March 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6106739
29 January 2016
Internal Structural Exam · Hull Examination · DAPI Audit · Administrative Inspection · Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5806124
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2024
Resolved
46 CFR 182.455
The handle to the shutoff valve at the tank located inside the machinery space must be located so that the operator does not have to reach more than 12 inches into the machinery space and the valve handle must be shielded from the flames. Location of the shut off valve was greater than 12 inches. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Received photo evidence of proper operation of the pull system for the fuel shut off valves.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2021
Resolved
Vessel's connection to battery terminals were not made with permanent type connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 16 March 2021
Resolution: Replaced with permanent type connectors.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 March 2021
Resolved
Ring life buoy is missing bung and the line used to connect required light is worn and frayed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 15 March 2021
Resolution: Ring life buoy was replaced in kind. Thew line to the floating light was replaced as well.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 March 2021
Resolved
Fuel tank vents are missing required flame screens.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 15 March 2021
Resolution: Flame screens were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 30 December 2019
Resolved
Remove all freeing port brackets and repair any holes from installation of brackets.
Action required: 705 - Other - as specified
Resolved 24 February 2020
Resolution: Freeing port brackets and previously installed closure devices were removed.
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 May 2017
Resolved
Provide on board current copies of Light List, Coast Pilot and Notice to Mariners IAW 46 CFR 184.420.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 8 May 2017
Resolution: Provided updated pubs.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 1 May 2017
Resolved
Post emergency instructions at operating station IAW 46 CFR 185.510
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 1 May 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 1 May 2017
Resolved
Replace pull cable for fixed fire extingushing system IAW 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 8 May 2017
Resolution: Pull cable replaced and checked.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 May 2017
Resolved
Replace bilge pump piping with rigid non-matallic hose IAW 46 CFR 182.520(f)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 8 May 2017
Resolution: Bilge pump hose replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 February 2016
Resolved
Vessel's 'all-around' anchor light is not positioned to be readily observed/seen; and a camera above the stern light creates a slight obstruction to the stern light. Reposition anchor light and camera above the stern light. IAW 33 CFR 83.20 and Nav. Rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 16 February 2016
Resolution: Raised 'all-around' anchor light so it can be readily observed/seen.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 February 2016
Resolved
Vessel has an electrical outlet out on deck by the ring buoy, without a cover. Outlet shall be covered and/or removed (if desired to not continue to use). IAW 46 CFR 183.210.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 16 February 2016
Resolution: Installed new electrical outlet and cover.