Records from 1989 to 2026. Most recent: inspection, 9 February 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 70
9 February 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8295990
13 January 2026
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8296002
6 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8108646
9 May 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7909560
26 January 2024
Drydock Extension · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7856338
28 May 2023
Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 7759262
3 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7679765
14 March 2023
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7655078
12 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7429370
28 December 2021
Drydock Exam · Deficiency Check · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7401385
11 March 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7122752
9 October 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7074676
5 October 2020
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7071756
14 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6939018
30 December 2019
Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6883325
2 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6654384
8 March 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6368455
29 January 2018
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6345825
8 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6141996
17 March 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6106739
29 January 2016
Internal Structural Exam · Hull Examination · DAPI Audit · Administrative Inspection · Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5806124
1 May 2014
Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4843167
2 May 2012
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4284745
1 February 2012
Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4236357
18 February 2011
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3937726
9 March 2010
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3688418
9 May 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3480991
2 April 2009
Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3444736
25 April 2008
Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 3193253
19 March 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3163194
10 March 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3163134
31 January 2008
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3139764
5 April 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2901659
2 April 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2899871
27 March 2007
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2893473
21 February 2006
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2588905
4 January 2006
Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2560827
18 February 2005
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2295416
22 March 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2001398
6 February 2004
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1992795
29 April 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1770120
12 April 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1600954
7 February 2002
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1485145
24 September 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1075241
9 May 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063741
12 April 2001
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063153
9 May 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 817690
11 April 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1048844
13 March 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1429307
1 June 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1432137
30 April 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 796894
3 April 1998
Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1364689
16 May 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1457451
8 July 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1088410
8 May 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1442391
11 March 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414601
6 June 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 877876
26 May 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1357172
15 July 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1181820
7 April 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 855700
10 June 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 841091
28 April 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962421
16 April 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 951869
11 March 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 834828
11 March 1992
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 951071
19 July 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1253929
19 June 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1226143
30 April 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 908330
12 April 1990
Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1236852
13 April 1989
Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1038038
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2024
Resolved
46 CFR 182.455
The handle to the shutoff valve at the tank located inside the machinery space must be located so that the operator does not have to reach more than 12 inches into the machinery space and the valve handle must be shielded from the flames. Location of the shut off valve was greater than 12 inches. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 23 May 2024
Resolution: Received photo evidence of proper operation of the pull system for the fuel shut off valves.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2021
Resolved
Vessel's connection to battery terminals were not made with permanent type connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 16 March 2021
Resolution: Replaced with permanent type connectors.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 March 2021
Resolved
Ring life buoy is missing bung and the line used to connect required light is worn and frayed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 15 March 2021
Resolution: Ring life buoy was replaced in kind. Thew line to the floating light was replaced as well.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 March 2021
Resolved
Fuel tank vents are missing required flame screens.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 15 March 2021
Resolution: Flame screens were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 30 December 2019
Resolved
Remove all freeing port brackets and repair any holes from installation of brackets.
Action required: 705 - Other - as specified
Resolved 24 February 2020
Resolution: Freeing port brackets and previously installed closure devices were removed.
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 May 2017
Resolved
Provide on board current copies of Light List, Coast Pilot and Notice to Mariners IAW 46 CFR 184.420.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 8 May 2017
Resolution: Provided updated pubs.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 1 May 2017
Resolved
Post emergency instructions at operating station IAW 46 CFR 185.510
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 1 May 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 1 May 2017
Resolved
Replace pull cable for fixed fire extingushing system IAW 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 8 May 2017
Resolution: Pull cable replaced and checked.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 May 2017
Resolved
Replace bilge pump piping with rigid non-matallic hose IAW 46 CFR 182.520(f)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 8 May 2017
Resolution: Bilge pump hose replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 February 2016
Resolved
Vessel's 'all-around' anchor light is not positioned to be readily observed/seen; and a camera above the stern light creates a slight obstruction to the stern light. Reposition anchor light and camera above the stern light. IAW 33 CFR 83.20 and Nav. Rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 16 February 2016
Resolution: Raised 'all-around' anchor light so it can be readily observed/seen.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 February 2016
Resolved
Vessel has an electrical outlet out on deck by the ring buoy, without a cover. Outlet shall be covered and/or removed (if desired to not continue to use). IAW 46 CFR 183.210.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 16 February 2016
Resolution: Installed new electrical outlet and cover.
Engineering › Fuel Oil Service System › Hose
Issued 1 May 2014
Resolved
Fuel supply hose fitting at generator must be factory-installed fitting for an SAE J-1942 type hose. 46CFR182.20-40
Action required: 705 - Other - as specified
Due 2 June 2014
Resolved 2 May 2014
Resolution: Fuel supply hose was corrected with proper connection to generator. Deficiency cleared.
Documentation › Markings/Placards › Lifejacket Placard
Issued 27 April 2009
Resolved
Provide life jacket donning placard applicable to style of lifejackets on board.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 27 April 2009
Resolution: Correct donning placard was obtained and on board.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 27 April 2009
Resolved
Replace 1 child lifejacket. Vessel is restricted to 20 passengers until item is completed.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 27 April 2009
Resolution: Child lifejacket was replaced.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 27 April 2009
Resolved
Provide Rules of the Road publication.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 27 April 2009
Resolution: Rules of the Road publication was obtained and on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 April 2009
Resolved
Replace expired ammonia inhalants.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 27 April 2009
Resolution: Ammonia inhalants were replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 April 2009
Resolved
Have fire extinguisher at operating station serviced.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 27 April 2009
Resolution: New A-I portable extinguisher was at the operating station.
Engineering › Fuel Oil Service System › Piping
Issued 31 January 2008
Resolved
1. Provide and install Fuel shut off valves at the fuel tank for the fuel supply piping to all engines as per 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 10 March 2008
Resolution: New shut off valve installed in fuel supply line.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 January 2008
Resolved
Provide and install cables in the rails on the bridge deck as per 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 10 March 2008
Resolution: New cables installed on bridge deck.
Lifesaving › Lifefloat › Painter
Issued 27 March 2007
Resolved
Properly attach the painter line to the lifefloat in accordance with 46 CFR 180.137.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Resolution: The painter line to the life float was properly attached.
Lifesaving › Lifefloat › Float-free Link
Issued 27 March 2007
Resolved
Properly attach the weak link to the vessel in accordance with 46 CFR 180.137.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Resolution: The weak link was properly attached to the vessel.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 March 2007
Resolved
Replace the grabline for the life ring in accordance with 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Resolution: The grab lines for the life ring was replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2007
Resolved
Remove the dead-end wire at the operating station in accordance with 183.340.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Resolution: The dead end wire at the operating station was replaced.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 27 March 2007
Resolved
Properly mount the EPIRB in accordance with 46 CFR 180.64.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Resolution: The EPIRB was properly mounted.
Engineering › Bilge Water Management System › Valve
Issued 27 March 2007
Resolved
Provide a positive shut-off valve at the hull penetration for the bilge discharge lines in accordance with 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 5 April 2007
Resolution: 1. Positive shut off valves at the hull penetrations were installed for the bilge discharge lines.
Electrical › Electric Generation Source (service) › Generator
Issued 27 March 2007
Resolved
Properly clean the windings on the generator in accordance with 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Resolution: The generator winding were properly cleaned.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 March 2007
Resolved
Properly mount the battery for the generator in accordance with 46 CFR 183.350.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Resolution: the battery for the generator was properly mounted.
Engineering › Fuel Oil Service System › Valve
Issued 27 March 2007
Resolved
Provide a positive shut-off valve for the fuel line at the engine for both main diesel engines in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Resolution: Valves for both main engines were installed in the supply lines on the discharge side of the racor filters.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 March 2007
Resolved
Tighten the hand rails on the stern and port quarter in accordance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Resolution: The hand rails were properly secured.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 4 January 2006
Resolved
Replace both port and starboard strut bearings and replace intermediate shaft bearings if more than 50% worn.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Resolution: All bearings replaced
Engineering › Steering Gear System › Bracket/Clamp
Issued 4 January 2006
Resolved
Replace missing clamp on port shaft log.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Resolution: Clamp replaced
Engineering › Bilge Water Management System › Piping
Issued 4 January 2006
Resolved
Double clamp all vital systems (exhaust, bilge, raw water intake) in engine room and lazarette.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Resolution: All vital systems now double clamped.
Engineering › Steering Gear System › Rudder
Issued 4 January 2006
Resolved
Repack port and starboard rudders.
Action required: 705 - Other - as specified
Resolved 21 February 2006
Resolution: Rudders repacked
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 March 2005
Resolved
Repair inoperable high level alarm indicator IAW 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2005
Resolved 10 March 2005
Resolution: Alarms was repaired and operational.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 March 2005
Resolved
Repair inoperable port running light IAW 72 COLREGS
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Resolution: Light was operational.
Lifesaving › Buoyant Apparatus
Issued 22 March 2004
Resolved
Secure the painter for the lifefloat to the vessel.
Due 22 March 2004
Resolved 22 March 2004
Resolution: Painter secured to the vessel.
Engineering › Bilge Water Management System
Issued 22 March 2004
Resolved
Demonstrate proper operation of the bilge pump located in the steering compartment. 46 CFR 182.500 LEGACY COMPONENT DESC: Pump
Due 22 March 2004
Resolved 22 March 2004
Resolution: Float switch was replaced and satisfactorily tested.
Fire Fighting › Fixed Fire Detection System
Issued 22 March 2004
Resolved
Demonstrate proper operation of the smoke detectors on the main deck. 46 CFR 181.120 LEGACY COMPONENT DESC: Smoke Detectors
Due 22 March 2004
Resolved 22 March 2004
Resolution: Batteries replaced and satisfactorily tested.
Navigation
Issued 12 April 2001
Resolved
PROVIDE UPDATED CHARTS AND PUBLICATIONS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Lifesaving
Issued 12 April 2001
Resolved
PROVIDE -2- ADULT LIFEJACKETS AS REQUIRED BY 46 CFR 180.71._x001C_ TOTAL PERSONS ALLOWED ON BOARD IS REDUCED TO -22- UNTIL CORRECTED.
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Fire Fighting
Issued 12 April 2001
Resolved
PROVIDE ADDTIONAL PORTABLE FIRE EXTINGUISHER (SIZE B-II) AS REQUIRED BY 46 CFR 176.810
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Navigation
Issued 12 April 2001
Resolved
PROVE PROPER OPERATION OF ELECTRONIC POSITIONING DEVICE AS REQUIRED BY 46 CFR 184.410
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Electrical
Issued 12 April 2001
Resolved
PROVIDE PROPER EMERGENCY LIGHTING IN THE ACCOMMODATION SPACES IN ACCORDANCEWITH 46CFR184.30-4.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Documentation
Issued 12 April 2001
Resolved
PROVIDE VALID FCC MARINE OPERATORS PERMIT IN ACCORDANCE WITH 47CFR80.905.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Accommodation/Occupational Safety
Issued 12 April 2001
Resolved
PROVIDE RAIL COURSES AT BOW PULPIT AS REQUIRED BY 46 CFR 177.900
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Accommodation/Occupational Safety
Issued 12 April 2001
Resolved
PROVIDE UPDATED FIRST AID KIT AS REQUIRED BY 46 CFR 184.710
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Construction/Loadline
Issued 12 April 2001
Resolved
PROVE PROPER OPERATION OF FORWARD HIGH BILGE ALARM AS REQUIRED BY 46 CFR 182.530._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Lifesaving
Issued 12 April 2001
Resolved
PROVIDE NEW RETRO-REFLECTIVE TAPE ON CHILDS LIFEJACKET AS REQUIRED BY 46 CFR 185.604._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Navigation
Issued 11 April 2000
Resolved
PROVIDE PROPER FCC DOCUMENTATION AS REQUIRED BY 47CFR 80.15.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Fire Fighting
Issued 3 April 1998
Resolved
PROVE PROPER OPERATION OF THE AUTOMATIC SHUTDOWN FOR THE GENERATOR. 46 CFR181.410(b)(10).
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Construction/Loadline
Issued 3 April 1998
Resolved
PROPERLY REPAIR ROTTED AREA OF SUPERSTRUCTURE IN WAY OF LADDER. NVIC 7-95.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Navigation
Issued 3 April 1998
Resolved
RENEW OR REPAIR RUDDER LINKAGE TO REMOVE EXCESS SLACK IN SYSTEM.46 CFR 182.620.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Construction/Loadline
Issued 16 May 1997
Resolved
THE VESSEL'S MAIN DECK CABIN AFT WEATHERTIGHT DOOR COAMING WAS NOT THE REQUIRED 6" COAMING. INSTALL COAMING IN ACCORDANCE WITH 46 CFR 179.360(d) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Navigation
Issued 16 May 1997
Resolved
THE OPERATOR COULD NOT PRODUCE UP-TO-DATE NAVIGATIONAL CHARTS AND PUBLICATIONS. PROVIDE CHARTS AND PUBLICATIONS IN ACCORDANCE WITH 46 CFR 184.420 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 16 May 1997
Resolved
THE OPERATOR COULD NOT PROVIDE EVIDENCE OF 50% OF DECKHANDS HAVING CPR TRAINING. PROVIDE EVIDENCE OF TRAINING IN ACCORDANCE WITH NVIC 1-91 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Navigation
Issued 16 May 1997
Resolved
THE OPERATOR DID NOT HAVE A VALID FCC OPERATOR'S LICENSE. PROVIDE A VALID LICENSE IN ACCORDANCE WITH 47 CFR 80.155 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Engineering
Issued 16 May 1997
Resolved
THE VESSEL'S STARBOARD FUEL TANK VENT DID NOT HAVE 30X30 WIRE MESH SCREENING. PROVIDE SCREENING IN ACCORDANCE WITH 46 CFR 182.450(e) PRIOR TOCOMPLIANCE DATE.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Engineering
Issued 8 May 1996
Resolved
TIGHTEN PORT PROPULSION ENGINE FOUNDATION MOTOR MOUNTS.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Electrical
Issued 8 May 1996
Resolved
PROVE PROPER OPERATION OF GENERATOR INDICATORS UNDER FULL LOAD.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Engineering
Issued 8 May 1996
Resolved
REMOVE ALL PUSH ON TYPE FUEL HOSES AND REPLACE WITH CRIMP OR REUSABLE TYPE FITTINGS THAT MET SAE STANDARD 1475.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Engineering
Issued 8 May 1996
Resolved
PROVIDE INLET COVERS/SCREENS/FILTERS FOR PROPULSION ENGINE TURBOCHARGERS TOPREVENT THE INJESTATION OF FORIEGN OBJECTS.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Accommodation/Occupational Safety
Issued 26 May 1995
Resolved
INSTALL VENT WITH 30X30 MESH SCREEN ON MSD TANK.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Lifesaving
Issued 26 May 1995
Resolved
REPAIR SMALL CUTS IN RING BOUY EXTERIOR COVERING
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Electrical
Issued 26 May 1995
Resolved
PROVIDE GENERATOR NAME PLATE IAW 46CFR183.10-5 (f)(2) STATING THAT GENERATOR WAS DERATED BY 80%.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Accommodation/Occupational Safety
Issued 26 May 1995
Resolved
PROVIDE A MEANS TO DETERMINE WHEN THE MSD TANK IS 3/4 BY VOLUME.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Fire Fighting
Issued 16 April 1992
Resolved
INSTALL PROPER FIRE EXTINGUISHER BRACKET IN UPPER LIVING SPACE.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Electrical
Issued 16 April 1992
Resolved
REMOVE UNAPPROVED GENERATOR FUEL PUMP WIRE.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Engineering
Issued 16 April 1992
Resolved
INSTALL FLAME SCREENS AND FUEL TANK VENTS FOR PORT AND STARBOARD FUEL TANKS.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Accommodation/Occupational Safety
Issued 16 April 1992
Resolved
REMOVE CRACKED FORWARD PORT LIVING SPACE WINDOW.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Electrical
Issued 16 April 1992
Resolved
INSTALL AND PROVE PROPER OPERATION OF GENERATOR GAUGES.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Electrical
Issued 16 April 1992
Resolved
REMOVE NON-FUNCTIONING LIGHT AND WIRE FROM LAZZARETTE.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Navigation
Issued 19 June 1991
Resolved
REMOVE ALL TINTED WINDOWS IN PILOT HOUSE. REPLACE WITH CLEAR WINDOWS OR PROVE NO MORE THAN 20 PERCENT OF LIGHT IS FILTERED OUT. TEST IS TO BE WITNESSED BY COAST GUARD MARINE INSPECTOR_x001C_ _x001C_
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Electrical
Issued 30 April 1991
Resolved
INSTALL FIVE APPROVED LIGHTING FIXTURES IN ACCORDANCE WITH 46 CFR 183.10-20THREE FIXTURES IN ENGINE ROOM AND TWO FIXTURES IN STEERING COMPARTMENT
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Documentation
Issued 30 April 1991
Resolved
PROVIDE VALID FCC OPERATORS LICENSE
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991
Resolved
PROVIDE TWO CHILDREN PERSONAL LIFE PRESERVERS. UNTIL TWO PFD'S ARE PROVIDEDNO MORE THAN ONE CHILD MAY BE CARRIED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Unknown
Issued 12 April 1990
Resolved
SUBMIT VESSEL'S DOCUMENT TO SHOW VESSEL'S NEW NAME AND OWNER.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Unknown
Issued 12 April 1990
Resolved
PROVIDE VALID FCC RADIO STATION LICENSE.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Unknown
Issued 12 April 1990
Resolved
LABEL LIFE JACKET STORAGE ON MAIN DECK AND ABOVE AND REMOVE LIFE JACKET LABELING FROM BELOW DECK STORAGE LID.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Unknown
Issued 12 April 1990
Resolved
SERVICE FIRE EXTINGUISHERS.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Unknown
Issued 12 April 1990
Resolved
FREE CHECK VALVE UNDER SINK AFT OF CABIN AND PROVE OPERATION OF BILGE SUCTION SYSTEM.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Unknown
Issued 12 April 1990
Resolved
ATTACH STEAM VOID HATCH TO VESSEL.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Lifesaving
Issued 13 April 1989
Resolved
PROVIDE ADEQUATE STOWAGE FOR LIFE PERSERVERS AT MAIN DECK LEVEL OR ABOVE.
Condition: Unknown
Due 13 April 1989
Resolved 13 April 1989
Documentation
Issued 13 April 1989
Resolved
PROVIDE PROOF OF CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 13 April 1989
Resolved 13 April 1989
Documentation
Issued 13 April 1989
Resolved
PROVIDE PROOF OF FCC OPERATORS LICENSE.
Condition: Unknown
Due 13 April 1989
Resolved 13 April 1989
Documentation
Issued 13 April 1989
Resolved
PROVIDE PROOF OF CURRENT FCC RADIO STATION LICENSE.
Condition: Unknown
Due 13 April 1989
Resolved 13 April 1989