MAURY USCG vessel records Sign in
← All vessels

YOU KING

YOU KING is a 1981 freight ship. The Coast Guard has recorded 14 inspections since 1989, most recently in March 2006, along with 15 deficiencies and 3 operational controls.

Records from 1989 to 2006. Most recent: operational control imposed, 15 March 2006.

Built
1981
Last inspected
15 March 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7927532 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
327673
Flag
HONG KONG
—
Maury page id
psix-327673

Inspections, by type

…with no type recorded12
Years with a record 6 calendar years (1989–2006)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it7274 - Convention (Subpart B), Net Ton
18332 - Dead Weight, Ton
25588 - Displacement, Ton
12995 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

15 March 2006 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2603290
15 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2603319
15 July 2002 Annual Inspection · Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1646905
12 August 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 406671
3 February 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 722166
13 January 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 140201
13 January 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 399449
6 January 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 714582
6 December 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 398494
30 November 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 397888
14 September 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 488047
6 March 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 335723
3 September 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 332347
15 March 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 329067

Deficiency record · 15

Engineering › Steering Gear System › Rudder Angle Indicator
Issued 15 March 2006 Resolved
While testing the steering gear, pumps No. 1 and No. 2 are showing a deviation of 5 degrees from the navigation deck to the steering gear room in all modes of operation. The rudder angle indicator is not working as designed.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 March 2006
Resolution: Received proper documentation stating deficiency has been rectified.
Operations/Management › FireFighting
Issued 17 July 2002 Resolved
Vessel's crew failed to perform satisfactory fire drill on 4 separate occasions. Expanded exam of ISM conducted using the Addendum to Foreign Vessel Exam Books for ISM Code Requirements. Based on results of exam and crew's performance during drill, an external audit of vessel's ISM was required. LEGACY COMPONENT DESC: ISM
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2002
Resolved 19 July 2002
Resolution: Received results on an External Audit of vessel''s SMS. Two non-conformaties issued for training and firefighting equipment. Equipment replaced and satisfactory drill conducted.
Electrical › Electrical Distribution System (service)
Issued 15 July 2002 Resolved
Welding machine hard wired to three-phase breaker on an open ventilation control panel forward deck store. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2002
Resolved 15 July 2002
Resolution: Vessels electrician disconnected welding machine and closed panel.
Operations/Management › Drills/Instruction
Issued 15 July 2002 Resolved
Crew failed to perform proper fire drill on 2 separate occasions. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2002
Resolved 19 July 2002
Resolution: Crew completed a satisfactory fire drill.
Fire Fighting › Self-contained Breathing Apparatus
Issued 15 July 2002 Resolved
Both SCBA's not ready for immediate use. One had two empty bottles, the other had a split o-ring on the bottle. SOLAS 74A II-2/17.3 LEGACY COMPONENT DESC: Air Bottle
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2002
Resolved 19 July 2002
Resolution: Vessel received two new SCBA units and six new air bottles.
Fire Fighting › International Shore Connection
Issued 15 July 2002 Resolved
International Shore Connection missing gasket and two bolts. SOLAS II-2/5(h) LEGACY COMPONENT DESC: Bolts
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2002
Resolved 17 July 2002
Resolution: Gasket and bolts provided.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 15 July 2002 Resolved
No.3 Cargo hold aft stbd. side ram and Stbd. side jack for hatch cover leaking notable amounts of hydraulic fluid. SOLAS 74A I/11 LEGACY COMPONENT DESC: Hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2002
Resolved 15 March 2006
Resolution: CG Marine Inspector examined No. 3 Cargo hold aft stbd. side ram and Stbd side jack for hatch cover leaks of hydraulic fluid. No leaks were found. All examined this date satisfactory.
Deck/Cargo › Holds/Tanks › Hatch
Issued 15 July 2002 Resolved
No.1 cargo hold's control box located port side is leaking hydraulic fluid at a rate of approximately 1 drop per second. SOLAS 74A I/11 LEGACY COMPONENT DESC: Hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2002
Resolved 15 March 2006
Resolution: Received class report from BV satisfying requirement.
Navigation › Piloting/Steering
Issued 15 July 2002 Resolved
Indication lights for both steering pumps on bridge are inoperable. SOLAS 74A I/11 LEGACY COMPONENT DESC: Operational Indication Lights
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 July 2002
Resolved 17 July 2002
Resolution: Inspected indication lights for both pumps. Both lights have been rewired and are in working order.
Operations/Management › Drills/Instruction
Issued 15 July 2002 Resolved
Vessel's crew were not properly trained in the use of SCBA equipment and donning fire outfit. Lack of training documented on May 18th and June 2nd. Vessel's crew is required to demonstrate proper use and donning of fire outfit to satisfaction of USCG. LEGACY COMPONENT DESC: Fire
Due 15 July 2002
Resolved 19 July 2002
Resolution: Witnessed satisfactory fire drill.
Navigation
Issued 6 December 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 December 1996
Resolved 13 December 1996
Navigation
Issued 6 December 1996 Resolved
THE VESSEL WAS MISSING THE INLAND NAVIGATION RULES. THE VESSEL CORRECTED THE DEFICIENCY PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Navigation
Issued 30 November 1996 Resolved
Repair Gyrocompass prior to departure from next U.S. port.(LOSMS). ChaptV, Regulation 12(d).
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Navigation
Issued 15 March 1989 Resolved
U.S. COAST PILOT, 23RD ED, VOL 7, 1987 NOR APPLICABLE PUBLICATION NOT ON BOARD.
Condition: Unknown
Due 15 March 1989
Resolved 15 March 1989
Navigation
Issued 15 March 1989 Resolved
EQUIPMENT TEST REQUIRED BY 33CFR 164.25 WAS NOT RECORDED IN VESSEL LOG.
Condition: Unknown
Due 15 March 1989
Resolved 15 March 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.