MAURY USCG vessel records Sign in
← All vessels

CHARLESTONIAN

CHARLESTONIAN is a 2001 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2002, most recently in March 2019, along with 45 deficiencies and 1 operational control.

Records from 2002 to 2019. Most recent: inspection, 6 March 2019.

Built
2001
Last inspected
6 March 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8968313 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA6819
Flag
UNITED STATES
366836480 (licence lapsed)
Maury page id
psix-32801

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2002–2019)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it44 - Dead Weight, Gross Ton
44 - Displacement, Gross Ton
169 - Convention (Subpart B), Gross Ton
61 - Regulatory (Subpart C or D), Gross Ton
50 - Convention (Subpart B), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA6819MMSI 366836480 · expired · voluntarily equipped · granted 25 January 2002, cancelled 31 March 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 15

6 March 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6637756
20 February 2019 Administrative Inspection · Construction Oversight
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6629474
17 March 2009 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3435192
23 April 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3190438
6 March 2008 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3147680
10 October 2007 Damage Survey · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3076977
30 May 2007 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2946498
5 February 2007 Administrative Inspection · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2906654
25 May 2006 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2658565
24 August 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2472381
1 March 2005 Annual Inspection · Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2305114
25 June 2004 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2109251
7 August 2003 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1867399
6 March 2003 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1753297
21 February 2002 Initial Certification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1488013

Deficiency record · 45

Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 March 2009 Resolved
Replace or Renew worn grablines on two liferings. One located main deck forward and the second topside aft.
Due 23 April 2009
Resolved 1 July 2009
Stability › Watertight Integrity › General
Issued 17 March 2009 Resolved
Plug hole in watertight bulkhead located on starboard side aft (steering compartment).
Due 23 April 2009
Resolved 17 March 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 March 2008 Resolved
Have valid COD on board vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2008
Resolved 21 March 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 6 March 2008 Resolved
Have valid FCC station license on board
Due 6 March 2008
Resolved 6 March 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 March 2008 Resolved
Have current light list and tidal current tables on board.
Due 18 March 2008
Resolved 21 March 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 March 2008 Resolved
Replace worn life line on lifering.
Due 18 March 2008
Resolved 21 March 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 March 2008 Resolved
Replace asprin and eyewash in first aid kit.
Due 18 March 2008
Resolved 21 March 2008
Engineering › Bilge Water Management System › Valve
Issued 6 March 2008 Resolved
Install positive shutoff valves on bilge overboard discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2008
Resolved 21 March 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 6 March 2008 Resolved
Replace broken fitting on MSDII tank.
Due 18 March 2008
Resolved 21 March 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 March 2008 Resolved
Install high level bilge alarm in starboard bow thruster room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2008
Resolved 21 March 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 March 2008 Resolved
Repair all high level alarm on vessel, alarm panel malfunctioning.
Due 6 March 2008
Resolved 21 March 2008
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 25 May 2006 Resolved
Water pump on port Generator failed during start up.
Condition: Unknown
Due 17 June 2006
Resolved 8 June 2006
Resolution: Replaced water pump.
Engineering › Steering Gear System › Rudder
Issued 24 August 2005 Resolved
Starboard rudder is bent. Properly renew.
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: Rudder was inspected and is in good condition.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 23 August 2005 Resolved
Prove proper operation of starboard internal shaft bearing
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: Witnessed satisfactory operation of starboard internal shaft bearing.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 23 August 2005 Resolved
Replace port strut bearing.
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: Port strut bearing was replaced.
Stability › Watertight Integrity › General
Issued 23 August 2005 Resolved
Make all bulkhead penetrations below main deck watertight.
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: Penetrations are high enough within the spaces to not cause concern about watertight integrity and were part of the original build of the vessel.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 March 2005 Resolved
replace all type 2 childrens lifejackets, with new type 1 childrens life jacket
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2005
Resolution: New Type I lifejackets provided
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 7 March 2005 Resolved
Replace two worn out life rings with new .
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2005
Resolution: New life rings provided
Engineering › Fuel Oil Service System › Piping
Issued 7 March 2005 Resolved
Fix leaking fuel Pipe
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2005
Resolved 11 March 2005
Resolution: Leak repaired
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 March 2005 Resolved
Expired fixed Co2 system
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2005
Resolution: CO2 system serviced
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 June 2004 Resolved
Vessel master's CPR training was expired, and vessel did not meet the minimum requirements of having 50% of the crew trained in CPR/First Aide
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2004
Resolved 28 June 2004
Resolution: Vessel''s master and engineer attended 1st Aide/CPR class the following day.
Lifesaving › Buoyant Apparatus › General
Issued 25 June 2004 Resolved
Vessel's lifering on the top deck was deteriorated due to UV/Weather exposure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2004
Resolved 28 June 2004
Resolution: Vessel replaced lifering with a new one.
Engineering › Bilge Water Management System › Pump
Issued 25 June 2004 Resolved
Bilge pumps and high-water alarms in both engine compartments were not properly installed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2004
Resolved 28 June 2004
Resolution: Vessel''s engineer attached both pumps and high water alarms properly to the vessel.
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 June 2004 Resolved
Fuel shut off valve was not properly marked in the space below decks.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2004
Resolved 28 June 2004
Resolution: Fuel shut off valve was clearly marked so as to avoid confusion with another valve close by.
Construction/Loadline › Hull
Issued 6 March 2003 Resolved
Properly plug thru-hull fitting in way of the sewage hold, starboard hull, inboard bulkhead. Hole plugged with wooden plug. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Due 20 March 2003
Resolved 25 March 2003
Resolution: deficiency corrected
Electrical › Electrical Distribution System (service)
Issued 6 March 2003 Resolved
Properly secure 3 dead end wires located in: Starboard engine room, forward, outboard space; starboard hold under bathroom in forward most cabin; and port fuel compartment. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 20 March 2003
Resolved 25 March 2003
Resolution: deficiency corrected
Electrical › Electrical Distribution System (service)
Issued 6 March 2003 Resolved
provide proper blanks for main switchboard (port side main deck) to eliminate electrical hazards. LEGACY COMPONENT DESC: Switchboard
Condition: Improper Installation
Due 20 March 2003
Resolved 25 March 2003
Resolution: deficiency corrected
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 March 2003 Resolved
Update expired items in first aid kit LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 20 March 2003
Resolved 25 March 2003
Resolution: deficiency corrected
Documentation › Certificates/Documents
Issued 6 March 2003 Resolved
Properly post COI and Stability letter LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Improper Installation
Due 20 March 2003
Resolved 25 March 2003
Resolution: deficiency corrected
Documentation › Certificates/Documents
Issued 3 August 2001 Resolved
original not on board LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Placed in Improper Service
Due 30 August 2001
Resolved 30 August 2001
Documentation › Certificates/Documents
Issued 3 August 2001 Resolved
original applied for but not yet on board LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Documentation › Markings/Placards
Issued 3 August 2001 Resolved
Placard for PSV allowed on top deck missing. LEGACY COMPONENT DESC: Capacity Marking
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Documentation › Certificates/Documents
Issued 3 August 2001 Resolved
Final stability letter not on board. LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Operations/Management › Drug and Alcohol Testing
Issued 3 August 2001 Resolved
EAP info not available LEGACY COMPONENT DESC: EAP Display Requirements
Condition: Placed in Improper Service
Due 30 August 2001
Resolved 30 August 2001
Operations/Management › Drug and Alcohol Testing
Issued 3 August 2001 Resolved
EAP training and policy statementsa not availible. LEGACY COMPONENT DESC: EAP Training Requirements
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Lifesaving › Lifejacket/PFD (General)
Issued 3 August 2001 Resolved
Life jacket donning placards missing LEGACY COMPONENT DESC: Storage
Condition: Placed in Improper Service
Due 30 August 2001
Resolved 30 August 2001
Operations/Management › Drills/Instruction
Issued 3 August 2001 Resolved
Conduct proper man overboard drill prior to carrying passengers. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Operations/Management › Drills/Instruction
Issued 3 August 2001 Resolved
Conduct proper fire drill prior to carrying passengers LEGACY COMPONENT DESC: Fire
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Operations/Management › Drills/Instruction
Issued 3 August 2001 Resolved
Conduct proper abandon ship drill prior to carrying passengers. LEGACY COMPONENT DESC: Abandon Ship
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Engineering › Bilge Water Management System
Issued 3 August 2001 Resolved
Bilge piping penetrations need to be sealed at bulkheads. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 3 August 2001
Resolved 3 August 2001
Communications › Internal Communications System
Issued 3 August 2001 Resolved
PA speaker needed on flying bridge deck.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Fire Fighting › Fire Hoses › Length
Issued 3 August 2001 Resolved
Improper lenght fire hoses installed. replace with 50ft.
Condition: Improper Installation
Due 30 August 2001
Resolved 30 August 2001
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 August 2001 Resolved
Ring buoys missing name and hailing port.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 August 2001 Resolved
Awaiting final draft of fire control plan for approval.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 3 August 2001 Resolved
Awaiting final approval on damage stability.
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.