MAURY USCG vessel records Sign in
← All vessels

TENDER 4

TENDER 4 is a 1989 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 1989, most recently in October 2017, along with 39 deficiencies.

Records from 1989 to 2017. Most recent: inspection, 17 October 2017.

Built
1989
Last inspected
17 October 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WUR 2029
328085
Flag
UNITED STATES
—
Maury page id
psix-328085

Inspections, by type

…with no type recorded4
Years with a record 23 calendar years (1989–2017)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it5 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 40

17 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6289108
16 September 2011 Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4146775
27 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4096416
11 May 2009 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3473000
23 April 2009 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3456632
14 November 2008 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3361540
12 August 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3296235
19 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3263344
15 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3189763
3 July 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2981977
23 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2932383
11 May 2006 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2646849
29 June 2005 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2407914
23 May 2005 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2365913
13 May 2005 Periodic Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2354370
13 May 2004 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2064169
24 November 2003 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1950796
16 May 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1778281
9 May 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1493966
14 May 2001 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1376642
9 June 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1050345
5 May 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 819358
12 May 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1455723
27 October 1998 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1368924
14 May 1998 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1444011
12 May 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1441231
13 May 1996 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1359188
15 May 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1434254
24 May 1994 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1436882
28 October 1993 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1454039
13 May 1993 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 834168
17 June 1992 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1260276
25 July 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 941911
17 May 1991 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 909389
26 July 1990 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 932965
24 May 1990 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 931497
18 May 1990 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 931818
3 May 1990 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 905404
26 April 1989 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1045237
25 April 1989 Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1034060

Deficiency record · 39

Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 May 2009 Resolved
Vessel was missing ventilation closure devices from the exhaust ducts from the engine room.
Action required: 705 - Other - as specified
Resolved 27 May 2009
Resolution: Vent closure in place.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 11 May 2009 Resolved
Main diesel engine would not start and operate properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2009
Resolution: Engine operating properly.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 May 2009 Resolved
High level bilge alarm was not properly activating on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2009
Resolution: High levelalarm tested sat.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 11 May 2009 Resolved
Throttle cable on engine had excessive slack and would not engage the throttle control from the pilot panel accurately.
Action required: 705 - Other - as specified
Resolved 27 May 2009
Resolution: Throttle cable adjusted properly.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 May 2008 Resolved
Provide proof of compliance with the Great Lakes Agreement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 12 August 2008
Resolution: 12AUG08: Received report from Dock Side Electronics for proof of Great Lakes Agreement. Outstanding deficiency cleared. MM
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 15 May 2008 Resolved
Provide MIS Report for 2007.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 19 June 2008
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 May 2008 Resolved
Provide onboard navigation rules, charts, light list and notice to mariners IAW 46CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 19 June 2008
Engineering › Fuel Oil Service System › Filter
Issued 23 May 2007 Resolved
Replace fuel strainer with one that meets 46 CFR 182.455(b)(6).
Due 30 May 2007
Resolved 29 June 2007
Resolution: Vessel removed existing F/O strainer and replaced with a fully contained metallic marine grade strainer that meets regulations.
Engineering › Bilge Water Management System › Pump
Issued 11 May 2006 Resolved
Properly install approved bilge pump in accordance with 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 26 May 2006
Resolution: Proper CG approved bilge pump was installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 May 2005 Resolved
Repair or replace radio equipment and prove its proper operation. Provide hand held radio until fixed.
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 19 May 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 13 May 2005 Resolved
Provide proof of training in first aid and CPR for crew.
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 29 June 2005
Resolution: Crew received CPR/First Aid training
Construction/Loadline › Hull › Side Shell
Issued 24 November 2003 Resolved
Repair cracking IWO ladder on port side shell (inside boat)
Due 30 May 2004
Resolved 13 May 2004
Resolution: Sighted this date [name withheld]
Construction/Loadline › Hull › Side Shell
Issued 24 November 2003 Resolved
Repair crack in stbd forward side shell (inside boat) IWO former repair. (poor work first time)
Due 13 May 2004
Resolved 13 May 2004
Resolution: Sighted this date [name withheld]
Documentation › Certificates/Documents
Issued 9 May 2002 Resolved
Provide proof that operators hold valid FCC radio operator permit.
Due 1 August 2002
Resolved 7 June 2002
Resolution: Faxed and received by [name withheld].
Fire Fighting
Issued 5 May 2000 Resolved
Provide & install breakglass enclosure for remote pull to fixed firefight- ing extinguishing system, in accordance with 46 CFR 181.410(b)(4), and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Fire Fighting
Issued 5 May 2000 Resolved
Prove proper operation of fixed firefighting extinguishing system remote pull and provide proof of the same to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 22 May 2000
Resolved 11 May 2000
Engineering
Issued 12 May 1999 Resolved
Properly repair or correct propulsion shaft packing leakage prior to the carraige of passengers and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Navigation
Issued 12 May 1999 Resolved
Provide means of auxiliary steering system prior to the carraige of passen-gers and to the satisfction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Navigation
Issued 12 May 1999 Resolved
Provide proper steering system double nut or cotter pin for tiller arm con-nection prior to the carraige of passengers and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Fire Fighting
Issued 12 May 1999 Resolved
Install fixed fire fighting system on vessel in accordance with manufactur-er's instructions and in accordance with 46 CFR 176. 810(a) prior to the carraige of passengers & to the satisfaction of attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Fire Fighting
Issued 12 May 1999 Resolved
Provide proof of proper operation of fixed fire fighting system engine shutdown test in accordance with manufacturer's instructions prior to the car- raige of passengers and to the satisfaction of attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Construction/Loadline
Issued 12 May 1999 Resolved
Properly install and prove proper operation of bilge high level alarm system prior to the carraige of passengers and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Documentation
Issued 12 May 1999 Resolved
Provide proof of employee training and logs for same prior to the carraige of passengers and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Fire Fighting
Issued 12 May 1999 Resolved
Provide proof of proper operation of fixed fire fighting system engine shutdown test in accordance with manufacturer's instructions prior to the car- raige of passengers and to the satisfaction of attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Documentation
Issued 12 May 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Documentation
Issued 12 May 1999 Resolved
Provided proof of stability letter prior to the carraige of passengers and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Electrical
Issued 12 May 1999 Resolved
Provide two portable flash lights in accordance with 46 CFR 183.430 prior to the carraige of passengers and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Construction/Loadline
Issued 12 May 1999 Resolved
Remove all oil, water and debris from all bilge areas of vessel prior to the carraige of passengers and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Unknown
Issued 12 May 1999 Resolved
Renew first aid kit due to falling in bilge and filling with oil/water mix-ture, in accordance with 46 CFR 184.710 prior to the carraige of passengersand to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Documentation
Issued 12 May 1999 Resolved
Provide for a means of making Certificate of Inspection, stability letter and all other required documents available on vessel prior to the carraige of passengers and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Construction/Loadline
Issued 12 May 1999 Resolved
Make proper repairs to electrical connections for vessel bilge pump system and prove proper operation of same prior to the carraige of passengers and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 June 1999
Resolved 27 May 1999
Electrical
Issued 12 May 1997 Resolved
Provide 01 flashlight for vessel.
Condition: Unknown
Due 27 May 1997
Resolved 28 May 1997
Engineering
Issued 12 May 1997 Resolved
Restencil "Fuel Shutoff" markings on main deck.
Condition: Unknown
Due 27 May 1997
Resolved 28 May 1997
Construction/Loadline
Issued 12 May 1997 Resolved
Prove proper operation of bilge pump system in all modes.
Condition: Unknown
Due 27 May 1997
Resolved 28 May 1997
Lifesaving
Issued 13 May 1996 Resolved
Renew grablines on life ring buoy.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Lifesaving
Issued 13 May 1996 Resolved
Attach retroreflective tape.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Lifesaving
Issued 13 May 1996 Resolved
Mark life ring buoy with vessels name.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Navigation
Issued 18 May 1990 Resolved
PLACE RED LENS IN PORT RUNNING LIGHT PRIOR TO NIGHT OPERATIONS AND IN NO CASE LATER THAN 31MAY90.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Deck/Cargo
Issued 18 May 1990 Resolved
PLACE ANCHOR AND ANCHOR LINE ON BOARD NOT LATER THAN 31MAY90.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990