Records from 1989 to 2026. Most recent: inspection, 14 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
14 May 2026
COI Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 8372432
23 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 8355220
22 May 2025
Deficiency Check
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 8141677
17 April 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8078833
18 April 2024
Internal Structural Exam · Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7887099
20 April 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7656403
6 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7429321
11 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7409532
26 April 2021
COI Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7183318
16 June 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6978389
7 April 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6921170
2 May 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6669276
30 April 2018
Drydock Exam · Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6418095
28 April 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6136955
27 April 2016
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5864073
11 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5842603
7 February 2012
Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4239895
11 May 2009
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3463589
14 April 2009
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3443757
28 April 2008
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3184592
8 May 2007
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2914379
27 March 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2896204
2 May 2006
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2627271
25 April 2005
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2327607
6 April 2005
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2327651
3 May 2004
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2058044
6 May 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1785020
15 April 2003
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1770142
22 April 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1494448
2 August 2001
Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1070750
25 July 2001
Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 66163
11 May 2001
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1393733
23 April 2001
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1393732
5 May 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1386827
28 July 1999
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1107971
12 May 1999
Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1130500
7 May 1998
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1125948
14 April 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 788465
1 May 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1099969
6 May 1996
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1082493
8 May 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1360102
2 May 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1227381
17 May 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1414303
27 May 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1434010
20 May 1992
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1261162
15 May 1991
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1222349
22 May 1990
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1217356
15 March 1989
Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1031056
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 April 2025
Resolved
Each flare must be stowed in a portable watertight container marked as required by 185.614 of this chapter, carried at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2025
Resolved 6 May 2025
Resolution: Operator provided watertight container to the satisfaction of the reviewing Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2025
Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation in which case no floating water light is required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2025
Resolved 6 May 2025
Resolution: Vessel operator repaired floating water light to the satisfaction of the reviewing Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 May 2024
Resolved
A vessel must carry an approved first-aid kit in a suitable, watertight container that is marked "First-Aid Kit" and made easily visible and available to the crew. Vessel's pre-packaged first-aid kit was expired and insufficient. Install a serviceable first-aid kit that meets the criteria of ISO 18813 (see Federal Register Vol. 87, No. 218).
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 9 May 2024
Resolution: Operator submitted photographic evidence of corrective action.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 May 2024
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) three hand red flare distress signals; and (2) three hand orange smoke distress signals. Vessel's flares were expired upon inspection. Replace all expired flare distress signals with serviceable items.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 9 May 2024
Resolution: Operator submitted photographic evidence of corrective action.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2024
Resolved
A vessel not required to have a power driven fire pump must have three 2.5-gallon buckets with an attached lanyard satisfactory to the [name withheld] three fire buckets were unequipped with lanyards. Attach lanyards of adequate size and reach to all three fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 10 May 2024
Resolution: Operator submitted photographic evidence of corrective action.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 May 2024
Resolved
The person in command of a registered vessel must have on board that vessel the original registration currently in effect for that vessel. Vessel's state registration was expired upon inspection. Additionally, the lapsed registration specified a pleasure vessel registration. Obtain a valid state registration for commercial carriage of passengers prior to operating.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Operator submitted photographic evidence of corrective action.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2023
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring buoy is not marked with retroreflective material. Provide retroreflective material on the ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 14 May 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2023
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of
crewmembers on inspected vessels who occupy a position, or perform the duties and functions of a position, required
by the vessel’s Certificate of Inspection. Prove all launch operators are in full compliance with the Maritime Consortium drug program prior to operating the launch.
Action required: 705 - Other - as specified
Resolved 21 April 2023
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 April 2023
Resolved
Fire and Man Overboard drills must be conducted and logged at least once within a 3 month period before the vessel gets underway with passengers. Vessel is missing log book, provide log book and conduct drills with each operator prior to carriage of passengers. Document drills in log book.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 April 2023
Resolved
Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at
the vessel’s normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Passenger count was not available, provide a means to communicate passenger count to shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 14 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2022
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2.5 gallon fire buckets, with an attached lanyard satisfactory to the OCMI, placed so as to be easily available during an emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Vessel was outfitted with three fire bucket, but no lanyards were attached, nor were the words "FIRE BUCKET" stenciled on the items. Attach lanyard of sufficient length to collect water with regard to the vessel's freeboard, and stencil the words "FIRE BUCKET" on each of the items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 11 May 2022
Resolution: Operator submitted photos to the OCMI, showing that all three fire buckets were stenciled appropriately, and that lanyards were attached pursuant to 46 CFR 181.610.
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 11 May 2009
Resolved
Retroreflective material on all lifejackets worn.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2009
Resolved 19 May 2009
Resolution: Replaced retroreflective material (tape) on all lifejackets.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 April 2005
Resolved
Service all portable and fixed fire extinquishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2005
Resolved 5 May 2005
Resolution: cleared
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 April 2005
Resolved
Replace battey cover for vessel main battery.
Due 16 May 2005
Resolved 5 May 2005
Resolution: Battery cover is installed.
Lifesaving › Lifejacket/PFD (General)
Issued 6 May 2003
Resolved
Relocate 03 child Type II PFD's aft to assigned location. PFD's were stored together with adult PFD's forward. LEGACY COMPONENT DESC: Storage
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2003
Resolved 21 July 2003
Resolution: PFD''S RELOCATED FORWARD
Fire Fighting › Ventilation Systems
Issued 6 May 2003
Resolved
Provide means to secure engine compartment vents in conjuction with fixed fire system. LEGACY COMPONENT DESC: Ducts
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2003
Resolution: INSTALLED SINGLE LOUVER TYPE VENT.
Engineering
Issued 2 August 2001
Resolved
Propeller was bent due to striking submerged object. Issued requirement forinspection and u/w trials after repairs, and prior to carrying passengers.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Engineering
Issued 2 August 2001
Resolved
Shaft was bent due to striking submerged object. Issued requirement for inspection and underway trials after repairs, and prior to carrying passengers.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Lifesaving
Issued 7 May 1998
Resolved
Properly repair/replace ring buoy periphery line
Condition: Unknown
Due 7 May 1998
Resolved 11 May 1998
Lifesaving
Issued 6 May 1996
Resolved
Properly label the three child life jackets
Condition: Unknown
Due 17 May 1996
Resolved 31 May 1996
Lifesaving
Issued 6 May 1996
Resolved
Provide four additional adult lifejackets.
Condition: Unknown
Due 17 May 1996
Resolved 31 May 1996
Fire Fighting
Issued 6 May 1996
Resolved
Properly service the fixed firefighting system. The vessel is not authorized to operate until this item is completed.
Condition: Unknown
Due 17 May 1996
Resolved 31 May 1996
Lifesaving
Issued 8 May 1995
Resolved
PROPERLY ATTACH 60 FT LINE TO RINGBUOY.
Condition: Unknown
Due 8 May 1995
Resolved 11 May 1995
Lifesaving
Issued 8 May 1995
Resolved
POST EMERGENCY CHECK LIST.
Condition: Unknown
Due 8 May 1995
Resolved 11 May 1995
Lifesaving
Issued 8 May 1995
Resolved
REPLACE WATERLIGHT.
Condition: Unknown
Due 8 May 1995
Resolved 11 May 1995
Deck/Cargo
Issued 8 May 1995
Resolved
ATTACHED SUFFICIENT LINE TO ANCHOR FOR DEPTH VSL IS OPERATED IN.
Condition: Unknown
Due 8 May 1995
Resolved 11 May 1995
Fire Fighting
Issued 8 May 1995
Resolved
CHANGE LOCATION OF BI FIRE EXTINGUISHER FROM AFT STEERING SPACE TO ON DECK NEAR OPERATOR.
Condition: Unknown
Due 8 May 1995
Resolved 11 May 1995
Fire Fighting
Issued 8 May 1995
Resolved
REPLACE BI FIRE EXTINGUISHER.
Condition: Unknown
Due 8 May 1995
Resolved 11 May 1995