Records from 2016 to 2026. Most recent: inspection, 26 May 2026.
Documentation record
Registered dimensions (L × B × D)34.4 ft × 12.4 ft × 4.0 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderT JASON BOATS INC. · STEUBEN, ME, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portMURRELLS INLET, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
26 May 2026
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8383496
18 December 2025
Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8285307
7 March 2025
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8089318
30 April 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7904202
8 December 2023
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7837322
9 May 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7684742
11 May 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7448875
10 February 2022
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7375591
27 April 2021
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7148106
16 September 2020
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7059386
27 February 2020
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6915515
18 February 2020
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6899766
31 May 2019
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6696434
7 December 2018
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6580483
31 January 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6349893
7 July 2017
DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6201416
2 March 2017
Examination of Repairs · Plan Review "T" Boat · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6277093
10 January 2017
Hull Examination · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6065525
4 May 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5868995
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 February 2020
Resolved
Primary deck stanchions for main cabin roof were found "deteriorated" IWO Port: 2,3,4,5 & Starboard: 3,4,5. Owner/Operator authorized temporary repairs through 2020 operating season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 27 April 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 February 2020
Resolved
Outer periphery of main cabin top/roof was found "deteriorated". Owner/Operator authorized temporary repairs through the 2020 operating season.
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 27 April 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 February 2020
Resolved
Fasteners for main cabin vertical stanchions (x4) were found "wasted". *all fasteners are above the waterline.
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 27 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 February 2020
Resolved
Dead ended wiring noted IWO fwd bilge pump terminal strip.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2020
Resolved 2 March 2020
Resolution: Attending Inspector received notification from O/O advising that repairs had been made to vessels bilge pump wiring/terminal strip.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 February 2020
Resolved
Keel plug sealant IWO port/fwd (keel) requires renewing due to deterioration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2020
Resolved 3 March 2020
Resolution: Attending Inspector(s) verified re-sealing of keel plug.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 31 January 2018
Resolved
Portable fire extinguishers required servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2018
Resolution: Attending Inspector(s) verified servicing/installation of portable fire extinguishers on board.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 January 2018
Resolved
Buoyant lifeline was (UV) deteriorated and required replacement.
Condition: Improper/Lack of Maintenance
Due 1 February 2018
Resolved 1 February 2018
Resolution: Attending Inspector(s) verified replacement of buoyant line in way of ring buoy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 January 2018
Resolved
Floating water light was not equipped with corrosion resistant clip.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 1 February 2018
Resolution: Attending Inspector(s) verified replacement of floating water light lanyard and corrosion resistant clip.
Navigation › Piloting/Steering › Marine Charts
Issued 7 July 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 28 July 2017
Resolution: Attending Inspectors verified carriage of current/up to date navigation publications for areas transited.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 July 2017
Resolved
Vessels current COD expired on 30MAY2017. O/O had filed for new document prior to expiration of existing document.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 6 November 2017
Resolution: Attending Inspector verified status of COD via NVDC.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 7 July 2017
Resolved
EAP (program) not implemented/posted on board.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 21 July 2017
Resolution: Attending Inspector verified carriage/implementation of EAP (program).
Stability › Watertight Integrity › General
Issued 7 July 2017
Resolved
Watertight hatch along main deck required adjustment for proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 28 July 2017
Resolution: Attending Inspector verified adjustments made to main deck watertight hatch.
Documentation › Markings/Placards › Warning Signs
Issued 7 July 2017
Resolved
Vessels main emergency exits along main deck were not properly marked/identified.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 21 July 2017
Resolution: Attending Inspector verified markings for emergency escapes along the main deck.
Engineering › Fuel Oil Service System › Hose
Issued 10 January 2017
Resolved
Primary fuel hose was attached to fuel fittings via plastic wire ties.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 11 January 2017
Resolution: Attending Inspector(s) witnesssed removal of plastic wire ties from fuel system. O/O elected to utilized stainless steel screw clamps.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 January 2017
Resolved
Provisions of the vessels COI were not accurate; H.P. of engines, pax count verbiage did not match stability letter.
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 11 January 2017
Resolution: Attending Inspector(s) corrected information on vessels COI (via Amendment).
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 4 May 2016
Resolved
Replace retro.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 1 February 2018
Resolution: Attending Inspectors verified installation of retro-reflective markings on all PFD's.