MAURY USCG vessel records
← All vessels

SPIRIT OF NEW JERSEY

Built
1989
Last inspected
19 February 2026
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 February 2026
…with no type recorded2
Operational controls 1 with no removal date recorded
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX9137
328227
Flag
UNITED STATES
Maury page id
psix-328227

Documentation record

Registered dimensions (L × B × D)157.7 ft × 33.0 ft × 9.5 ft
Registered tonnagegross 82 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERVICE MARINE INDUSTRIES · AMELIA, LA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 62 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

19 February 2026 Drydock Exam · Internal Structural Exam · Vessel Attendance · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8312388
17 February 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8311316
10 July 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8182051
3 June 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7925821
8 January 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7845370
6 August 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7762129
30 July 2023 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7755708
2 May 2023 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7679546
24 April 2022 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7437482
2 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7396724
9 December 2021 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7364544
2 September 2020 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7047610
19 August 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7035417
18 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6955193
6 January 2020 Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6883176
20 March 2019 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645475
19 February 2019 Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6630253
23 October 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6566358
1 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6552521
8 May 2018 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6408372
25 April 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6398877
24 April 2018 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6399125
18 January 2018 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339234
7 March 2017 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6099934
4 February 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5810336
2 February 2016 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5808255
14 January 2016 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5797455

Deficiency record · 62

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2026 Resolved
As the Spirit of New Jersey was being relaunched, a pinhole leak was identified in the forward port side galley area. Crop and renew the area prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 24 April 2026
Resolution: MI obsereved sat NDT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 February 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's Port Main engine is not operational. Submit causal analysis and repair plan.
Action required: 705 - Other - as specified
Resolved 14 June 2026
Resolution: The mechanic was working on the vessel before the shipyard and closed the keel cooler valve and it wasn't opened prior to departure. Engine is now fully operational w/ no damage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025 Resolved
46 CFR 182.05-1(a) "Old T" 701c Propulsion machinery shall be suitable in type... Exhaust leak observed on port side main engine. Submit repair plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2025
Resolution: Welds complete. SAT. Please see documents for photos/documentation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025 Resolved
46 CFR 182.05-1(a) "Old T" 701C Propulsion machinery shall be suitable in type... Starboard main engine raw water exhaust cooling leak observed. Submit a repair plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2025
Resolution: Welds complete. SAT. Please see documents for photos/documentation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025 Resolved
46 CFR 61.10-5(i) If your vessel's COI is renewed annual, the MI musut check the settings of the safety relief valve. Safety relief valve not tested, awaiting third party confirmation for inspection. complete w/i 7 days.
Action required: 705 - Other - as specified
Due 17 July 2025
Resolved 15 July 2025
Resolution: Servicing Completed. SAT. Please see documents for photos/documentation
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 February 2024 Resolved
Pin hole was found in bottom plating of the galley on the port side next to the doorway. Submit a repair plan for approval. Crop and renew to new metal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 February 2024
Resolution: Prior to credit DDX
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2024 Resolved
Stbd M/E water muffler is leaking and needs to be replaced to the satisfaction of attending CG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 April 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 January 2024 Resolved
Scaling was found in the fore-peak stbd aft bulkhead as well as a pin hole leading to the thruster compartment. Submit written repair plan for approval. Crop and renew to new metal.
Action required: 705 - Other - as specified
Resolved 1 February 2024
Resolution: Crop and renew was completed. Shipyard representatives conducted an air lance NDT. Test conducted was sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 January 2024 Resolved
Support framing was found cut in the thruster forward void aft of the tonnage bulkhead. Renew to original condition.
Action required: 705 - Other - as specified
Resolved 15 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 January 2024 Resolved
Thruster hydraulic motor was found leaking at the time of inspection. Replace/repair motor to the satisfaction of the USCG.
Action required: 705 - Other - as specified
Resolved 30 April 2024
Resolution: Vessel has completed repairs to bow thruster hydraulic leaks. This deficiency has been resolved.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2024 Resolved
Replace and properly install insulation in the thruster compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2024
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 8 January 2024 Resolved
starboard deck drain cover on 01 deck was found to be cracked and broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 January 2024 Resolved
Dead end wires were found above the office electrical distribution panel and the galley overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2024
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 January 2024 Resolved
Re-attach lanyard to either deck hatch for the for-peak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 January 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry dock exam and an internal structural exam at least once every two years. Vessel has outstanding work list items that must be cleared prior to receiving credit DDX and prior to carrying passengers. In addition, vessel has replaced Port and STBD generator ends. Both generators must be tested under load in the presence of CG MI and a technician prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Vessel has tested port and stbd generator's under load. This deficency has been resolved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 January 2024 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable...vessels contracted for on or after July 1st 1961, which carry more than 150 passengers shall meet the requirements of SubChapter H of this chapter. Vessel currently has plexi glass windows on the STBD side and windows on the main deck that are not sealed nor are installed properly as per original construction. In addition, vessel has sliding doors on the main deck Port and STBD side that are not weathertight. Watertight boundary and fire control boundary are not intact.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 January 2024 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Vessel's bilge pickup piping in the void space directly aft of the machinery space is severely corroded and must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2024 Resolved
Auxiliary machinery must be suitable in type and design for the purpose intended. Vessel has holes and active leaks in potable water piping. Replace piping IAW regulation and demonstrate proper operation of potable water system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 8 January 2024 Resolved
At each initial and subsequent inspection for certification and re inspection the marine inspector shall examine the passenger and crew quarters, toilet and washing spaces... to determine that they are serviceable and in sanitary condition. Vessel does not have working restroom facilities nor a fully operational sewage system. In addition, vessel has a strong sewage smell on the main deck. Rectify all hygiene issues to the satisfaction of CG MI prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Vessel has completed all repairs to washrooms. This worklist item has been resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2024 Resolved
Auxiliary machinery must be suitable in type and design for the purpose intended. Vessel's refrigeration compressor's relief valve was taped and covered in plastic as if to prevent leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2024 Resolved
n general, the electrical source located within the vessel and distribution system shall not be grounded. Vessel replaced both generating sets in kind. When conducting a load test, ground detection system appeared not to be functioning properly and was showing grounds in the system. Rectify prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 August 2023 Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated and shall be provided a means of closure. Starboard galley ventilation was damaged. Provide repair proposal and demonstrate proper operation of ventilation closure to the galley space.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2023
Resolved 10 August 2023
Resolution: Ventilation closures to galley space fully operational.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 6 August 2023 Resolved
Each device certified under this section which is installed aboard an inspected vessel must comply with 33 CFR 159.97. MI's discovered overflow of the currently installed Tyoe III MSD. Provide documentation attesting to type certification by the Marine Safety Center, any vessel specific operational procedures for timely discharge of the MSD and receipt of discharge to the shore facility.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2023
Resolution: specific operational procedures for timely discharge of the MSD and receipt of discharge to the shore facility were provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2023 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Damage to aft starboard transom bulwarks. Submit repair proposal to the satisfaction of the OCMI & provided acceptable procedures to ensure passengers are not permitted accidental or unauthorized access to the effected area.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2023
Resolution: Repair satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 August 2023 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operations in accordance with the terms on the COI. Water was allowed to penetrate the vessel through the temporary windows causing a pooling in way of the window in the passenger accommodation space. Ensure temporary windows have adequate seal to ensure a weather tight seal and submit an acceptable mitigation plan to remove all standing water from accommodation space.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2023
Resolution: temporary windows have adequate seal to ensure a weather tight seal. All standing water removed from accomodation area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 May 2023 Resolved
A power ventilation system must be capable of being shut down from the pilot house. Ventilation shutdown is inoperative. Vessel shall implement mitigating strategies until rectified. Rectify in 7 days. 46 CFR 116.600(b)
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 May 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 May 2023 Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air through the ventilation duct in the event of fire. 46 CFR 116.610 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2023
Resolved 9 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2023 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Vessel's PTO was inop. Rectify in 7 days. 46 CFR 182.25-10 (Old T)
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2023 Resolved
All electrical installations shall be to the satisfaction of the OCMI. All electrical equipment and circuits must be clearly marked and identified. Panel in second deck service space was not marked. Rectify in 7 days. 46 CFR 183.01-15(a) (Old T) 46 CFR 120.220(d)
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 25 July 2023
Resolution: Received photographic evidence breaker panel has been properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 May 2023 Resolved
Each floating waterlight must be approved in accordance with 161.010 in subchapter Q. Battery is expired. Rectify in 7 days. 46 CFR 117.70(d)(1)
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2022 Resolved
Life jackets must be stored in convenient places and must be readily available. During in-service inspection it was witnessed that the two adult life jacket storage areas forward on the main deck where blocked by food serving tables creating an obstacle to retrieve and distribute life jackets in the case of an emergency. Vessel crew immediately relocated tables to opposite bulkhead, clearing deficiency on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 April 2022
Resolved 24 April 2022
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 April 2022 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate high water level in shaft alley which is a normally unmanned space. During in-service inspection, there was nuisance water and oil in the shaft alley bilge. This space is equipped with two high water level bilge alarms, during testing of the high water level bilge alarms only one of the bilge alarms provided an audible and a visual alarm on the navigation bridge. Considering the redundancy of the alarms, deficiency was cleared on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 April 2022
Resolved 24 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2022 Resolved
water heater is not protected by a pressure temperature relief valve
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2022
Resolved 4 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2022 Resolved
Starboard engine room battery charger must be equipped with marine grade wire
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 23 March 2022
Resolution: MI observed marine grade wire on engine room battery charger.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 March 2022 Resolved
Carpet passed between fire doors on 2nd deck and wheel house.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 23 March 2022
Resolution: Vessel removed sections of carpet located below fire door on 2nd deck/wheel house.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 March 2022 Resolved
Upper deck do not have donning placards for vessel's life jacket
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 23 March 2022
Resolution: MI observed proper life jacket placards.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 March 2022 Resolved
Forward lazeret bulkhead penetration needs to be sealed
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 23 March 2022
Resolution: MI witnessed proper fire stop in fwd lazarette space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 December 2021 Resolved
Remove water from bow thruster space.
Action required: 705 - Other - as specified
Resolved 10 January 2022
Resolution: Water removed.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 20 March 2019 Resolved
During inspection it was noted that the port main engine exhaust manifold had a leak. Leak must be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Exhaust leak repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2019 Resolved
During inspection it was noted that hydraulic fluid was leaking from the bow thruster. Leak must be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Leak was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 March 2019 Resolved
During inspection it was noted that in the photo-genics room fire stop was missing in a cable penetration in the overhead. Fire stop must be provided to area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Fire stop was added to the cable penetration.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 March 2019 Resolved
During inspection it was noted that the bilges in the galley and engine room space need to be properly cleaned of grease, oil, and water.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Bilgews were clean
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 March 2019 Resolved
During inspection it was noted that the nozzle on the fire hose 3rd deck did not operate properly. Install nozzle that can provide stream and fog spray.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Vessel replaced fire nozzle
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 March 2019 Resolved
During inspection it was noted that the vessel did not have an approved first aid kit. Vessel must provide an approved first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Vessel provided an approved medical kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2019 Resolved
During inspection it was noted that there was a leak on the port side generator. Vessel must repair leak and clean up all oil on and around the generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2019
Resolved 8 April 2019
Resolution: Generator was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2019 Resolved
During inspection it was noted that the electrical panel in the tank space was not labeled. Label breaker panel.
Action required: 705 - Other - as specified
Due 27 March 2019
Resolved 25 March 2019
Resolution: Panel was labeled
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 March 2019 Resolved
During inspection it was noted that AIS was broadcasting the wrong call sign. Vessel must update call sign.
Action required: 705 - Other - as specified
Due 27 March 2019
Resolved 25 March 2019
Resolution: AIS was updated with correct information.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 February 2019 Resolved
Vessel loss steering while attempting to get u/w from its home port due to a loss of one generator that was operating in parallel with another. Vessel must find cause of this incident, make corrective repairs, submit a written report signed by the master, and conduct sea trials with a CGMI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
Resolution: Testing completed with CGMI
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 October 2018 Resolved
Vsl is broadcasting Invalid Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 September 2020
Resolution: Attending Marine Inspector witnessed correct call sign displayed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 May 2018 Resolved
A vessel must carry adequate and up to date U.S. Coast Pilot and Light List publications. Vessel was discovered with 2017 versions of each publication and requires the updated 2018 versions. 46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Vessel carries required publications.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 8 May 2018 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. New child and adult life jackets on board did not have vessel's name marked on them. 46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 8 May 2018
Resolution: Vessel stenciled all life jackets during inspection.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 8 May 2018 Resolved
At every vessel inspection, bilges must not have excessive accumulation of oil that might create a fire hazard. Engine room and bow thruster space were discovered to have significant oil accumulation, which must be removed and cleaned from each space. 46 CFR 176.830(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Bow thruster and engine room spaces were cleaned of all hazmat and oil.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 May 2018 Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. Battery trays in engine room were found deteriorated and must be replaced in kind. 46 CFR 183.350(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Battery trays were properly replaced.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 May 2018 Resolved
At each vessel inspection, all observed unsafe practices and other hazardous situations must be corrected. Compressed bottles in soda room were not stowed properly, and must either be removed or lashed down. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Compressed bottles were properly lashed down.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 May 2018 Resolved
Each lighting fixture globe must have a guard. Light covers were discovered missing in the liquor cabinet. Owner must replace all light covers. 46 CFR 183.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: All light covers properly replaced.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 8 May 2018 Resolved
A penetration in a watertight bulkhead must be made watertight. Wire run between galley and engine room was not sealed, and must be made watertight. 46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Wire run sealed through watertight bulkhead.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 8 May 2018 Resolved
Doors in A-Class fire control boundaries must be of the self-closing type. Door leading from the stairwell to the galley was not able to independently properly close. Owner must make door self-closing. 46 CFR 116.435(c)(6)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Galley door verified to close properly.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 May 2018 Resolved
At each vessel inspection, all observed unsafe practices and other hazardous situations must be corrected. Water was discovered sitting under the tiles outside the female head on second deck. Owner must remove excess water and make the area safe for passengers and crew.46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Verified all water hazard removed.
Electrical › Electric Generation Source (emergency) › Ground Indicator
Issued 8 May 2018 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Vessel discovered to have 2amps to ground; owner must determine the source and remove all amps to ground. 46 CFR 200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 1 June 2018
Resolution: Received documentation demonstrating satisfactory correction of ground.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 April 2018 Resolved
Duty Marine Inspector received from the CG Command Center notification that the vessel's bow thruster stopped working during docking maneuvers with passengers on board. The OCMI and Coast Guard Marine Inspector (CGMI)have determined that the bow thruster is essential to the routine operation of the vessel and require it to be fixed and prove proper operation to a CGMI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2018
Resolution: Provided paper work attesting to training held to operate vessel without bow thruster.
Communications › Public Address System › Loudspeaker
Issued 2 February 2016 Resolved
Vessel's public address system is not audible from upper most deck. Vessel is restricted from carrying passengers on upper most deck until repaired.
Due 3 March 2016
Resolved 4 February 2016
Resolution: Vessel proved function of PA system to attending marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 2 February 2016 Resolved
Door on child lifejacket locker on second deck aft port side is broken. Repair or replace.
Due 16 February 2016
Resolved 4 February 2016
Resolution: Vessel repaired hinge on lifejacket locker door.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.