SPIRIT OF NEW JERSEY

SPIRIT OF NEW JERSEY is a 1989 passenger vessel (inspected). The Coast Guard has recorded 119 inspections since 1989, most recently in February 2026, along with 150 deficiencies, 2 operational controls, 1 with no removal date recorded and 3 casualty investigations between 2005 and 2015.

Records from 1989 to 2026. Most recent: inspection, 19 February 2026.

Built
1989
Last inspected
19 February 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WCX9137
328227
Flag
UNITED STATES
367016470
Maury page id
psix-328227

Inspections, by type

…with no type recorded23
Years with a record 37 calendar years (1989–2026)
The 119 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)157.7 ft × 33.0 ft × 9.5 ft
Registered tonnagegross 82 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERVICE MARINE INDUSTRIES · AMELIA, LA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9688MMSI 367016470 · active · compulsorily equipped · granted 21 March 2018, expires 21 March 2028
WCX9137MMSI 367016470 · terminated · compulsorily equipped · granted 29 December 2007, cancelled 22 February 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 119

19 February 2026 Drydock Exam · Internal Structural Exam · Vessel Attendance · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8312388
17 February 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8311316
10 July 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8182051
3 June 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7925821
8 January 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7845370
6 August 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7762129
30 July 2023 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7755708
2 May 2023 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7679546
24 April 2022 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7437482
2 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7396724
9 December 2021 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7364544
2 September 2020 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7047610
19 August 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7035417
18 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6955193
6 January 2020 Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6883176
20 March 2019 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645475
19 February 2019 Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6630253
23 October 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6566358
1 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6552521
8 May 2018 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6408372
25 April 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6398877
24 April 2018 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6399125
18 January 2018 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339234
7 March 2017 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6099934
4 February 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5810336
2 February 2016 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5808255
14 January 2016 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5797455
9 December 2015 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5778054
16 June 2014 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4893224
15 June 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4890964
12 March 2014 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4814581
11 January 2012 Plan Review (Other than "T") · Construction Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4223496
4 January 2012 Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4227484
3 February 2011 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3937018
27 October 2010 Examination of Repairs · Internal Structural Exam · Hull Examination · Deadweight Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3879223
27 January 2010 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3670536
16 January 2009 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3397522
16 January 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3401653
14 January 2009 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3390634
5 November 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3357545
12 September 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3323186
4 July 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3261922
23 June 2008 Plan Review "T" Boat · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3245304
21 February 2008 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3150940
12 February 2008 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3147543
2 April 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2908959
7 February 2007 MARPOL Annex V Examination · Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2871982
23 January 2007 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2860343
10 August 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2750833
10 August 2006 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2776605
15 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649860
2 February 2006 MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2579843
11 December 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2549564
17 August 2005 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2466217
11 August 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2464956
8 August 2005 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2455605
24 July 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2438672
16 July 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2429593
12 July 2005 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2424041
3 February 2005 Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2285773
10 November 2004 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2238387
10 August 2004 MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2162725
4 August 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2315453
29 January 2004 MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1996173
16 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1968361
3 February 2003 Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1738861
5 November 2002 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1701148
7 October 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1685922
26 August 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1667947
11 February 2002 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1485634
20 November 2001 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1391726
4 October 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423663
9 February 2001 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1361976
10 May 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1424908
21 March 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1047049
9 February 2000 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1395370
21 April 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 96216
3 February 1999 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1433441
20 November 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1408207
12 May 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1471978
2 May 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 97190
2 May 1998 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1471973
28 April 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1438722
10 April 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1125682
26 February 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1118423
23 January 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1413297
21 March 1997 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1104875
27 February 1997 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1108974
27 January 1997 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1102821
4 October 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1443759
1 March 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 885176
28 April 1995 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 864346
27 April 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 863799
27 April 1995 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1172789
3 March 1995 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 865804
7 December 1994 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1139897
23 May 1994 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 870815
8 March 1994 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1169881
31 January 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1162632
23 March 1993 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 837897
22 January 1993 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 828040
22 January 1993 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1178081
15 December 1992 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 830267
18 May 1992 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 948234
30 March 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 954168
15 March 1992 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1262237
12 March 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 948605
17 September 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1249722
21 June 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1209424
12 April 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1236363
3 April 1991 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1216460
13 February 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 905960
30 January 1991 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1237064
3 May 1990 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 912465
4 April 1990 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1238909
24 July 1989 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 898479
16 May 1989 Damage Survey · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1196914
9 May 1989 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1030897
10 April 1989 Hull Examination · Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043757

Deficiency record · 150

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2026 Resolved
As the Spirit of New Jersey was being relaunched, a pinhole leak was identified in the forward port side galley area. Crop and renew the area prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 24 April 2026
Resolution: MI obsereved sat NDT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 February 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's Port Main engine is not operational. Submit causal analysis and repair plan.
Action required: 705 - Other - as specified
Resolved 14 June 2026
Resolution: The mechanic was working on the vessel before the shipyard and closed the keel cooler valve and it wasn't opened prior to departure. Engine is now fully operational w/ no damage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025 Resolved
46 CFR 182.05-1(a) "Old T" 701c Propulsion machinery shall be suitable in type... Exhaust leak observed on port side main engine. Submit repair plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2025
Resolution: Welds complete. SAT. Please see documents for photos/documentation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025 Resolved
46 CFR 182.05-1(a) "Old T" 701C Propulsion machinery shall be suitable in type... Starboard main engine raw water exhaust cooling leak observed. Submit a repair plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2025
Resolution: Welds complete. SAT. Please see documents for photos/documentation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025 Resolved
46 CFR 61.10-5(i) If your vessel's COI is renewed annual, the MI musut check the settings of the safety relief valve. Safety relief valve not tested, awaiting third party confirmation for inspection. complete w/i 7 days.
Action required: 705 - Other - as specified
Due 17 July 2025
Resolved 15 July 2025
Resolution: Servicing Completed. SAT. Please see documents for photos/documentation
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 February 2024 Resolved
Pin hole was found in bottom plating of the galley on the port side next to the doorway. Submit a repair plan for approval. Crop and renew to new metal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 February 2024
Resolution: Prior to credit DDX
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2024 Resolved
Stbd M/E water muffler is leaking and needs to be replaced to the satisfaction of attending CG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 April 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 January 2024 Resolved
Scaling was found in the fore-peak stbd aft bulkhead as well as a pin hole leading to the thruster compartment. Submit written repair plan for approval. Crop and renew to new metal.
Action required: 705 - Other - as specified
Resolved 1 February 2024
Resolution: Crop and renew was completed. Shipyard representatives conducted an air lance NDT. Test conducted was sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 January 2024 Resolved
Support framing was found cut in the thruster forward void aft of the tonnage bulkhead. Renew to original condition.
Action required: 705 - Other - as specified
Resolved 15 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 January 2024 Resolved
Thruster hydraulic motor was found leaking at the time of inspection. Replace/repair motor to the satisfaction of the USCG.
Action required: 705 - Other - as specified
Resolved 30 April 2024
Resolution: Vessel has completed repairs to bow thruster hydraulic leaks. This deficiency has been resolved.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2024 Resolved
Replace and properly install insulation in the thruster compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2024
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 8 January 2024 Resolved
starboard deck drain cover on 01 deck was found to be cracked and broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 January 2024 Resolved
Dead end wires were found above the office electrical distribution panel and the galley overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2024
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 January 2024 Resolved
Re-attach lanyard to either deck hatch for the for-peak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 January 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry dock exam and an internal structural exam at least once every two years. Vessel has outstanding work list items that must be cleared prior to receiving credit DDX and prior to carrying passengers. In addition, vessel has replaced Port and STBD generator ends. Both generators must be tested under load in the presence of CG MI and a technician prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Vessel has tested port and stbd generator's under load. This deficency has been resolved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 January 2024 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable...vessels contracted for on or after July 1st 1961, which carry more than 150 passengers shall meet the requirements of SubChapter H of this chapter. Vessel currently has plexi glass windows on the STBD side and windows on the main deck that are not sealed nor are installed properly as per original construction. In addition, vessel has sliding doors on the main deck Port and STBD side that are not weathertight. Watertight boundary and fire control boundary are not intact.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 January 2024 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Vessel's bilge pickup piping in the void space directly aft of the machinery space is severely corroded and must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2024 Resolved
Auxiliary machinery must be suitable in type and design for the purpose intended. Vessel has holes and active leaks in potable water piping. Replace piping IAW regulation and demonstrate proper operation of potable water system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 8 January 2024 Resolved
At each initial and subsequent inspection for certification and re inspection the marine inspector shall examine the passenger and crew quarters, toilet and washing spaces... to determine that they are serviceable and in sanitary condition. Vessel does not have working restroom facilities nor a fully operational sewage system. In addition, vessel has a strong sewage smell on the main deck. Rectify all hygiene issues to the satisfaction of CG MI prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Vessel has completed all repairs to washrooms. This worklist item has been resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2024 Resolved
Auxiliary machinery must be suitable in type and design for the purpose intended. Vessel's refrigeration compressor's relief valve was taped and covered in plastic as if to prevent leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2024 Resolved
n general, the electrical source located within the vessel and distribution system shall not be grounded. Vessel replaced both generating sets in kind. When conducting a load test, ground detection system appeared not to be functioning properly and was showing grounds in the system. Rectify prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 August 2023 Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated and shall be provided a means of closure. Starboard galley ventilation was damaged. Provide repair proposal and demonstrate proper operation of ventilation closure to the galley space.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2023
Resolved 10 August 2023
Resolution: Ventilation closures to galley space fully operational.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 6 August 2023 Resolved
Each device certified under this section which is installed aboard an inspected vessel must comply with 33 CFR 159.97. MI's discovered overflow of the currently installed Tyoe III MSD. Provide documentation attesting to type certification by the Marine Safety Center, any vessel specific operational procedures for timely discharge of the MSD and receipt of discharge to the shore facility.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2023
Resolution: specific operational procedures for timely discharge of the MSD and receipt of discharge to the shore facility were provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2023 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Damage to aft starboard transom bulwarks. Submit repair proposal to the satisfaction of the OCMI & provided acceptable procedures to ensure passengers are not permitted accidental or unauthorized access to the effected area.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2023
Resolution: Repair satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 August 2023 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operations in accordance with the terms on the COI. Water was allowed to penetrate the vessel through the temporary windows causing a pooling in way of the window in the passenger accommodation space. Ensure temporary windows have adequate seal to ensure a weather tight seal and submit an acceptable mitigation plan to remove all standing water from accommodation space.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2023
Resolution: temporary windows have adequate seal to ensure a weather tight seal. All standing water removed from accomodation area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 May 2023 Resolved
A power ventilation system must be capable of being shut down from the pilot house. Ventilation shutdown is inoperative. Vessel shall implement mitigating strategies until rectified. Rectify in 7 days. 46 CFR 116.600(b)
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 May 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 May 2023 Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air through the ventilation duct in the event of fire. 46 CFR 116.610 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2023
Resolved 9 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2023 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Vessel's PTO was inop. Rectify in 7 days. 46 CFR 182.25-10 (Old T)
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2023 Resolved
All electrical installations shall be to the satisfaction of the OCMI. All electrical equipment and circuits must be clearly marked and identified. Panel in second deck service space was not marked. Rectify in 7 days. 46 CFR 183.01-15(a) (Old T) 46 CFR 120.220(d)
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 25 July 2023
Resolution: Received photographic evidence breaker panel has been properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 May 2023 Resolved
Each floating waterlight must be approved in accordance with 161.010 in subchapter Q. Battery is expired. Rectify in 7 days. 46 CFR 117.70(d)(1)
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2022 Resolved
Life jackets must be stored in convenient places and must be readily available. During in-service inspection it was witnessed that the two adult life jacket storage areas forward on the main deck where blocked by food serving tables creating an obstacle to retrieve and distribute life jackets in the case of an emergency. Vessel crew immediately relocated tables to opposite bulkhead, clearing deficiency on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 April 2022
Resolved 24 April 2022
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 April 2022 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate high water level in shaft alley which is a normally unmanned space. During in-service inspection, there was nuisance water and oil in the shaft alley bilge. This space is equipped with two high water level bilge alarms, during testing of the high water level bilge alarms only one of the bilge alarms provided an audible and a visual alarm on the navigation bridge. Considering the redundancy of the alarms, deficiency was cleared on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 April 2022
Resolved 24 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2022 Resolved
water heater is not protected by a pressure temperature relief valve
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2022
Resolved 4 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2022 Resolved
Starboard engine room battery charger must be equipped with marine grade wire
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 23 March 2022
Resolution: MI observed marine grade wire on engine room battery charger.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 March 2022 Resolved
Carpet passed between fire doors on 2nd deck and wheel house.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 23 March 2022
Resolution: Vessel removed sections of carpet located below fire door on 2nd deck/wheel house.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 March 2022 Resolved
Upper deck do not have donning placards for vessel's life jacket
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 23 March 2022
Resolution: MI observed proper life jacket placards.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 March 2022 Resolved
Forward lazeret bulkhead penetration needs to be sealed
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 23 March 2022
Resolution: MI witnessed proper fire stop in fwd lazarette space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 December 2021 Resolved
Remove water from bow thruster space.
Action required: 705 - Other - as specified
Resolved 10 January 2022
Resolution: Water removed.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 20 March 2019 Resolved
During inspection it was noted that the port main engine exhaust manifold had a leak. Leak must be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Exhaust leak repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2019 Resolved
During inspection it was noted that hydraulic fluid was leaking from the bow thruster. Leak must be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Leak was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 March 2019 Resolved
During inspection it was noted that in the photo-genics room fire stop was missing in a cable penetration in the overhead. Fire stop must be provided to area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Fire stop was added to the cable penetration.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 March 2019 Resolved
During inspection it was noted that the bilges in the galley and engine room space need to be properly cleaned of grease, oil, and water.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Bilgews were clean
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 March 2019 Resolved
During inspection it was noted that the nozzle on the fire hose 3rd deck did not operate properly. Install nozzle that can provide stream and fog spray.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Vessel replaced fire nozzle
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 March 2019 Resolved
During inspection it was noted that the vessel did not have an approved first aid kit. Vessel must provide an approved first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Vessel provided an approved medical kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2019 Resolved
During inspection it was noted that there was a leak on the port side generator. Vessel must repair leak and clean up all oil on and around the generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2019
Resolved 8 April 2019
Resolution: Generator was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2019 Resolved
During inspection it was noted that the electrical panel in the tank space was not labeled. Label breaker panel.
Action required: 705 - Other - as specified
Due 27 March 2019
Resolved 25 March 2019
Resolution: Panel was labeled
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 March 2019 Resolved
During inspection it was noted that AIS was broadcasting the wrong call sign. Vessel must update call sign.
Action required: 705 - Other - as specified
Due 27 March 2019
Resolved 25 March 2019
Resolution: AIS was updated with correct information.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 February 2019 Resolved
Vessel loss steering while attempting to get u/w from its home port due to a loss of one generator that was operating in parallel with another. Vessel must find cause of this incident, make corrective repairs, submit a written report signed by the master, and conduct sea trials with a CGMI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
Resolution: Testing completed with CGMI
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 October 2018 Resolved
Vsl is broadcasting Invalid Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 September 2020
Resolution: Attending Marine Inspector witnessed correct call sign displayed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 May 2018 Resolved
A vessel must carry adequate and up to date U.S. Coast Pilot and Light List publications. Vessel was discovered with 2017 versions of each publication and requires the updated 2018 versions. 46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Vessel carries required publications.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 8 May 2018 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. New child and adult life jackets on board did not have vessel's name marked on them. 46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 8 May 2018
Resolution: Vessel stenciled all life jackets during inspection.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 8 May 2018 Resolved
At every vessel inspection, bilges must not have excessive accumulation of oil that might create a fire hazard. Engine room and bow thruster space were discovered to have significant oil accumulation, which must be removed and cleaned from each space. 46 CFR 176.830(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Bow thruster and engine room spaces were cleaned of all hazmat and oil.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 May 2018 Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. Battery trays in engine room were found deteriorated and must be replaced in kind. 46 CFR 183.350(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Battery trays were properly replaced.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 May 2018 Resolved
At each vessel inspection, all observed unsafe practices and other hazardous situations must be corrected. Compressed bottles in soda room were not stowed properly, and must either be removed or lashed down. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Compressed bottles were properly lashed down.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 May 2018 Resolved
Each lighting fixture globe must have a guard. Light covers were discovered missing in the liquor cabinet. Owner must replace all light covers. 46 CFR 183.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: All light covers properly replaced.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 8 May 2018 Resolved
A penetration in a watertight bulkhead must be made watertight. Wire run between galley and engine room was not sealed, and must be made watertight. 46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Wire run sealed through watertight bulkhead.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 8 May 2018 Resolved
Doors in A-Class fire control boundaries must be of the self-closing type. Door leading from the stairwell to the galley was not able to independently properly close. Owner must make door self-closing. 46 CFR 116.435(c)(6)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Galley door verified to close properly.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 May 2018 Resolved
At each vessel inspection, all observed unsafe practices and other hazardous situations must be corrected. Water was discovered sitting under the tiles outside the female head on second deck. Owner must remove excess water and make the area safe for passengers and crew.46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Verified all water hazard removed.
Electrical › Electric Generation Source (emergency) › Ground Indicator
Issued 8 May 2018 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Vessel discovered to have 2amps to ground; owner must determine the source and remove all amps to ground. 46 CFR 200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 1 June 2018
Resolution: Received documentation demonstrating satisfactory correction of ground.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 April 2018 Resolved
Duty Marine Inspector received from the CG Command Center notification that the vessel's bow thruster stopped working during docking maneuvers with passengers on board. The OCMI and Coast Guard Marine Inspector (CGMI)have determined that the bow thruster is essential to the routine operation of the vessel and require it to be fixed and prove proper operation to a CGMI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2018
Resolution: Provided paper work attesting to training held to operate vessel without bow thruster.
Communications › Public Address System › Loudspeaker
Issued 2 February 2016 Resolved
Vessel's public address system is not audible from upper most deck. Vessel is restricted from carrying passengers on upper most deck until repaired.
Due 3 March 2016
Resolved 4 February 2016
Resolution: Vessel proved function of PA system to attending marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 2 February 2016 Resolved
Door on child lifejacket locker on second deck aft port side is broken. Repair or replace.
Due 16 February 2016
Resolved 4 February 2016
Resolution: Vessel repaired hinge on lifejacket locker door.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 9 December 2015 Resolved
STBD engine exhaust has pinhole leak which needs to be repaired PTCP
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2015
Resolved 11 December 2015
Resolution: Exhaust leak repaired; tested while stbd engine was running.
Engineering › Bilge Water Management System › Strainer
Issued 9 December 2015 Resolved
Bilge suction strainer is corroded in forepeak and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2015
Resolution: Bilge strainer replaced in forepeak.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 December 2015 Resolved
pumproom space has inoperatble bilge alarm.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2015
Resolution: Bilge alarm in pumproom tested and operable.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 19 June 2014 Resolved
Loss of power to port side main engine due to failure in reduction gear.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 July 2014
Resolved 19 June 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the Aris Low Profile LED Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the WAC 1 Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the WAC 2 Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the WAC 3 Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 25 April 2012
Resolution: Vessel did not install WAC 3 lighting.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the Leucos USA Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 25 April 2012
Resolution: Vessel did not install Leucos USA Lighting.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the WAC 4" Premium Low Voltage Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the MP Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the Interek Linear Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the [name withheld] L134 used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the Moda Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2012 Resolved
Provide additional information for the Artemide Dupla Indoor Double Halogen Lighting used in the Jan-Mar 2012 renovation and prove proper UL testing standards IAW 46 CFR 120.410.
Action required: 705 - Other - as specified
Resolved 23 May 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 January 2012 Resolved
Provide Electrical Line diagram with Load Analysis that documents the installation or removal of all lighting fixtures to CG [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2012
Resolution: Vessle rep provided Electrical line diagram.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 11 January 2012 Resolved
Provide results of Fire Load analysis to CG Marine Safety Center & [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2012
Resolution: CG MSC approved fire load calculations and structural fire protection plan.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 11 January 2012 Resolved
Provide additional information for the wall paper paste used in the hanging of the wall coverings on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 May 2012
Resolution: Wall covering in formation provided.
Stability › Watertight Integrity › General
Issued 11 January 2012 Resolved
Provide log book comparing the amount of weight added to/or removed from the vessel during the renovations conducted between Jan-Mar 2012 to CG [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2012
Resolution: Vessel is conducting a new deadweight survey see CG835 HA01.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 11 January 2012 Resolved
Provide proof of proper labeling to CG [name withheld] for the following items: Emergency Lighting, Exit Signs, Fire Extinguishers, Fuel Shut-Offs, Passenger Deck Capacity & Emerency Escape hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2012
Resolution: All signs and lableing found SAT.
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 27 January 2010 Resolved
Install tachometer on port generator.
Action required: 705 - Other - as specified
Due 27 February 2010
Resolved 28 January 2010
Resolution: Deficiency withdrawn.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 January 2010 Resolved
Label emergency light outside pilothouse.
Action required: 705 - Other - as specified
Due 27 February 2010
Resolved 29 January 2010
Resolution: Emergency light labeled. Deficiency cleared.
Construction/Loadline › Structures › Door
Issued 21 February 2008 Resolved
Galley Door is Mis-Aligned (Restricted Area).
Condition: Improper/Lack of Maintenance
Due 20 March 2008
Resolved 12 March 2008
Resolution: Galley door has been aligned properly.
Electrical › Electric Supply System (service) › Cable
Issued 21 February 2008 Resolved
Properly Secure Cabling Above Engine Room Watertight Door.
Condition: Placed in Improper Service
Due 20 March 2008
Resolved 12 March 2008
Resolution: Cable has been properly secured.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 21 February 2008 Resolved
Tighten Double-Clamping at Wet Exhaust at Muffler Canister. (Leaking)
Condition: Improper/Lack of Maintenance
Due 20 March 2008
Resolved 12 March 2008
Resolution: The double-clamping at the wet exhaust has been renewed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 February 2008 Resolved
Rubberized Matting Missing Beneath Main Switchboard.
Condition: Unknown
Due 20 March 2008
Resolved 12 March 2008
Resolution: Rubberized Matting has been placed Beneath Main Switchboard.
Electrical › Electrical Distribution System (service) › Cable
Issued 21 February 2008 Resolved
Repair Frayed Cable on Overhead Within Galley Space.
Condition: Improper/Lack of Maintenance
Due 20 March 2008
Resolved 12 March 2008
Resolution: Cable has been properly secured.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 21 February 2008 Resolved
Crop & Renew Air Intake Duct Work in Steering Space.
Condition: Improper/Lack of Maintenance
Due 20 March 2008
Resolved 12 March 2008
Resolution: The air intake duct work in the steering compartment was renewed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 February 2008 Resolved
Improve General Cleanliness in Galley/Bar Spaces.
Condition: Unknown
Due 20 March 2008
Resolved 12 March 2008
Resolution: Cleanliness has been improved.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 February 2008 Resolved
Vessel is restricted to carrying 400 passengers until CG Marine Safety Center has reviewed stability/weight change plans.
Action required: 705 - Other - as specified
Resolved 19 February 2008
Resolution: Received letter dated 19 FEB 2008 from MSC determining that a stability/deadweight survey does not need to be completed. The 400 passenger restriction is lifted.
Fire Fighting › Combustible Materials › Ceilings
Issued 12 February 2008 Resolved
Provide satisfactory fire test documentation for installed ceiling system.
Action required: 705 - Other - as specified
Resolved 23 June 2008
Resolution: Received satisfactory documentation for fire test conducted on installed ceiling system.
Fire Fighting › Firemans Outfit › Axe
Issued 2 April 2007 Resolved
Replace missing fire axe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 April 2007 Resolved
Replace port/stbd side windowns - main cabin space 01/02 deck (10 each).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 April 2007 Resolved
Replace aft pilot house window.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 April 2007 Resolved
Properly remove all broken glass from all passenger /crews spaces throughout vsl.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 February 2007 Resolved
Starboard side generator wet exhaust muffler has pin-holes and is leaking water/exhaust. Make permanent repairs or replace.
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 22 February 2007
Resolution: Muffler replaced.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 February 2007 Resolved
Port side generator wet exhaust flex hose/piping connection is leaking on top side of muffler. Secure water/exhaust leak.
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 22 February 2007
Resolution: Flex hose connection replaced.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 August 2006 Resolved
Prove proper operation of ship's radar to the satisfaction of the attending CG MI.
Due 24 August 2006
Resolved 24 August 2006
Resolution: Received tech report stating that radar was fixed.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 3 February 2005 Resolved
Electric system has a ground fault; determine nature of fault, correct and send tech report to marine inspectiors satisfaction.
Due 4 March 2005
Resolved 30 August 2005
Resolution: Ground fault is within acceptable limits.
Electrical › Lighting (service) › Outlet Box
Issued 3 February 2005 Resolved
Properly repair splice behind galley reefer.
Due 11 February 2005
Resolved 7 February 2005
Resolution: Observed new electrical cable properly connected in a junction box behind the forward portable refer.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 3 February 2005 Resolved
Secure all portable reefers.
Due 11 February 2005
Resolved 7 February 2005
Resolution: A wire cable was installed around all three portable refers.
Electrical › Lighting (service) › Lighting Fixture
Issued 3 February 2005 Resolved
Secure electrical connection on stern light on 02 deck
Due 11 February 2005
Resolved 7 February 2005
Resolution: The electrical connection on the sternlight was repaired.
Engineering › Bilge Water Management System › Pump
Issued 3 February 2005 Resolved
Bilge suction inop in forepeak, prove proper operation to marine inspector satisfaction - conduct and log 30 min rounds while pax onboard.
Due 11 February 2005
Resolved 7 February 2005
Resolution: Witnessed proper operation of the bilge pump dewatering the forepeak.
Electrical › Electrical Distribution System (service)
Issued 29 January 2004 Resolved
Remove old bow thruster controls in P/H. LEGACY COMPONENT DESC: Wiring
Due 5 February 2004
Resolved 29 January 2004
Fire Fighting › Structural - A Class Divisions › Doors
Issued 29 January 2004 Resolved
Install 3/4 inch throw to A-class door on 2nd deck.
Due 29 March 2004
Resolved 5 February 2004
Engineering › Generator (propulsion-electric)
Issued 29 January 2004 Resolved
Repair oil leaks on stbd MDE and generator fuel strainers.
Due 5 February 2004
Resolved 29 January 2004
Electrical › Lighting (service)
Issued 29 January 2004 Resolved
Replace broken light cover on port side aft deck
Due 5 February 2004
Resolved 5 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 29 January 2004 Resolved
C/R ladder rungs to fwd peak.
Due 5 February 2004
Resolved 5 February 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 3 February 2003 Resolved
Sanitize main deck bar, main deck serving station and galley. Vessel restricted from using these locations until inspected by an attending marine inspector.
Due 3 February 2003
Resolved 4 February 2003
Lifesaving › Lifejacket/PFD (General)
Issued 3 February 2003 Resolved
Provide means of separation between adult and childrens lifejackets in all combined storage locations. LEGACY COMPONENT DESC: Storage
Due 10 February 2003
Resolved 12 February 2003
Engineering › Pressure Vessel
Issued 3 February 2003 Resolved
Prove air receiver under wheelhouse console meets ASME 'U' or 'UM' approved certification.
Due 3 March 2003
Resolved 19 November 2003
Resolution: Viewed air receiver''s ASME UM stamp.
Engineering › Pressure Vessel
Issued 3 February 2003 Resolved
Replace relief valve on pressure vessel in E/R.
Due 3 February 2003
Resolved 4 February 2003
Engineering › Compressed Air System (control)
Issued 3 February 2003 Resolved
Repair oil leaks for gray and black water pumps at lower men's starboard head.
Due 3 March 2003
Resolved 19 November 2003
Engineering › Fuel Oil Service System
Issued 3 February 2003 Resolved
Make permanent repairs (minor) to port generator (#1) (fuel leak at filter) prior to use.
Due 3 February 2003
Resolved 4 February 2003
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 3 February 2003 Resolved
Make permanent repairs to A/C drain line in lazarette (broken pipe at union).
Due 10 February 2003
Resolved 12 February 2003
Documentation › Certificates/Documents
Issued 11 February 2002 Resolved
Post Certificate of Inspection in space accessible to passengers. LEGACY COMPONENT DESC: Certificate of Inspection
Due 19 February 2002
Resolved 20 February 2002
Resolution: Certificate posted on each deck.
Documentation › Markings/Placards
Issued 11 February 2002 Resolved
Remove expired COI sickers from vessel windows. LEGACY COMPONENT DESC: COI
Condition: Placed in Improper Service
Due 19 February 2002
Resolved 20 February 2002
Resolution: Expired stickers removed.
Lifesaving
Issued 11 February 2002 Resolved
Rewrite Station Bill to meet 46 CFR 122.514(c)1 & 4. LEGACY COMPONENT DESC: Station Bill
Condition: Design Flaw
Due 19 February 2002
Resolved 20 February 2002
Resolution: New Station Bill posted.
Electrical › Lighting (service)
Issued 11 February 2002 Resolved
Replace broken lighting fixture in stairwell prior to next excursion. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 14 February 2002
Resolved 20 February 2002
Resolution: Fixture replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 February 2002 Resolved
Replace two receptacles in engine room with approved type.
Condition: Placed in Improper Service
Due 26 February 2002
Resolved 12 February 2002
Resolution: Approved type installed.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 11 February 2002 Resolved
Clean chill box evaporator. LEGACY COMPONENT DESC: Evaporator
Condition: Improper/Lack of Maintenance
Due 14 February 2002
Resolved 20 February 2002
Resolution: Evaporator cleaned.
Accommodation/Occupational Safety › Messroom
Issued 11 February 2002 Resolved
Clean/sanitize galley and storage/chillbox shelves prior to next excursion.
Condition: Improper/Lack of Maintenance
Due 14 February 2002
Resolved 20 February 2002
Resolution: Galley/chillbox cleaned.
Accommodation/Occupational Safety › Messroom
Issued 11 February 2002 Resolved
Repair galley door and deck molding.
Condition: Unknown
Due 19 February 2002
Resolved 20 February 2002
Resolution: Molding & door repaired; handle installed.
Fire Fighting
Issued 9 February 2001 Resolved
Prove proper operation & maintenance of fire detection system. Vessel has an installed fire detection system which is not required, but IAW 46CFR118.120, must still be tested & maintained.
Condition: Unknown
Due 9 February 2001
Resolved 9 February 2001
Engineering
Issued 9 February 2000 Resolved
Tighten fuel cut out valve on stbd side of the line connecting to the fuel tanks.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Electrical
Issued 9 February 2000 Resolved
REPLACE BOTTOM OF BATTERY BOX FOR PORT MAIN.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Electrical
Issued 9 February 2000 Resolved
PROVIDE PROPER WIRE FOR THE BAND STAND AREA FOR BOTH DECKS.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Electrical
Issued 9 February 2000 Resolved
CAP OLD CONDUIT TO SHORE TIE ON PORT SIDE AFT ON MAIN DECK.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Construction/Loadline
Issued 9 February 2000 Resolved
REPLACE BROKEN OR MISSINGS DOGS TO BOTH CARGO DOORS POER AND STBD ON THE MAIN DECK.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Navigation
Issued 9 February 2000 Resolved
REPLACE PICK UP HOSE FROM RESERVOIR ON THE POWER TAKE OFF FROM THE GENERATOR FOR THE BOW THRUSTER.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Construction/Loadline
Issued 2 May 1998 Resolved
Effect permanent repairs to hole in hull plating, in way of first frame aftof fwd engine room bulkhead, stbd side, 1" outboard from keel. Repairs to be completed to satisfaction of attending marine inspector.
Condition: Unknown
Due 12 May 1998
Resolved 13 May 1998
Unknown
Issued 2 May 1998 Resolved
Vsl not to operate with passengers until hull repairs completed to satisfaction of attending marine inspector.
Condition: Unknown
Due 12 May 1998
Resolved 6 May 1998
Deck/Cargo
Issued 10 April 1998 Resolved
PROVE PROPER OPERATION OF BOW THRUSTER TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 10 April 1998
Resolved 10 April 1998
Deck/Cargo
Issued 23 January 1998 Resolved
Demonstrate proper operation of bow thruster to satisfaction of attending marine inspector.
Condition: Unknown
Due 23 January 1998
Resolved 26 January 1998
Unknown
Issued 23 March 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Lifesaving
Issued 3 April 1991 Resolved
REPAIR OR REPLACE SIX (6) DAMAGED BUOYANT APPARATUS.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Engineering
Issued 3 April 1991 Resolved
REPLACE SEA SUCTION HOSE STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Engineering
Issued 3 April 1991 Resolved
PROVIDE ADEQUATE RELIEF VALVE FOR AIR RECIEVER PROVIDING AIR FOR VESSEL BOWTHRUSTER CLUTCH AND WHISTLE. FAULTY RELIEF VALVE SETTING WAS 175 PSI, MAWP OF PRESSURE VESSEL 200 PSI.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Engineering
Issued 3 April 1991 Resolved
REPAIR GASKET AND INSTALL MISSING BOLT ON BILGE PUMP AND TEST FOR LEAKS PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Electrical
Issued 3 April 1991 Resolved
REPLACE OR REPAIR WARPED BATTERY CONTAINERS IN THE ENGINE ROOM.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Electrical
Issued 30 January 1991 Resolved
REINSTALL LATCH ON ENGINEROOM STARBOARD SIDE MAIN ELECTRICAL PANEL COVER TOSATISFACTION OF [name withheld].
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Construction/Loadline
Issued 30 January 1991 Resolved
INSTALL MEANS OF FIRE STOP PROTECTION EQUAL TO A-0 STRUCTURAL STANDARDS IN GALLEY AREA PORT SIDE OVERHEAD WIRING PENETRATION TO SATISFACTION OF [name withheld].
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Deck/Cargo
Issued 30 January 1991 Resolved
RENEW FUEL OIL VENT FLAME SCREENS TO SATISFACTION OF [name withheld]._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Engineering
Issued 4 April 1990 Resolved
PROVE OPERATION OF ALL GENERATOR AND MAIN ENGINE ALARMS AND TRIPS TO THE SATISFACTION OF [name withheld].
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Construction/Loadline
Issued 4 April 1990 Resolved
MAKE AFT BULKHEAD OF WATER TANK COMPARTMENT WATERTIGHT (PROVIDE GASKETS ANDSEAL FOR THROUGH BULKHEAD CONNECTIONS FOR SINKS AND HAND DRYER TO SATISFACTION OF [name withheld].
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Engineering
Issued 4 April 1990 Resolved
PROVE OPERATON OF PRESSURE VESSEL RELIEF VALVE TO SATISFACTION OF [name withheld].
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Engineering
Issued 4 April 1990 Resolved
PROVIDE ADEQUATE DRAINAGE/SUCTION & REMOVAL SYSTEM TO CLEAN GALLEY BILGES (DISPOSE OF GREASE) TO SATISFACTION OF [name withheld].
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Construction/Loadline
Issued 16 May 1989 Resolved
MAKE PERMANENT REPAIRS TO BROKEN MAIN DCK DINING ROOM STBD WINDOW (APPROX. MIDSHIP AREA) AMD TWO WINDOW FRAMING. THIS ITEM SHALL BE COMPLETED NO LATERTHAN 21MAY89. THIS ITEM SHALL BE COMPLETED TO THEEE STISFCTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989

Casualty record · 3

11 August 2005Routine · role: Involved in a Marine Casualty · activity 2464956
16 January 2009Routine · role: Involved in a Marine Casualty · activity 3401653
8 May 2015Routine · role: Involved in a Marine Casualty · activity 5123123
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.