← All vessels
SN FIVE 1
SN FIVE 1 is a freight ship. The Coast Guard has recorded 12 inspections since 2001, most recently in December 2010, along with 53 deficiencies — 12 with no resolution recorded — and 1 operational control.
Records from 2001 to 2010. Most recent: inspection, 27 December 2010.
- Built
- Not recorded
- Last inspected
- 27 December 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 53 recorded · 12 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it26 - Simplified, Net Ton
49 - Simplified, Gross Ton
49 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
27 December 2010
Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 3920737
17 November 2010
NPV Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3892899
18 January 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3397893
27 October 2008
NPV Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3353406
30 January 2007
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2863735
5 September 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2768848
25 August 2006
NPV Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2757800
5 December 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 296197
10 October 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 294788
8 October 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 443568
21 August 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 519621
28 July 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 504579
Deficiency record · 53
Construction/Loadline › Structures › Machinery Space Opening
Issued 17 November 2010
No resolution recorded
Found forward and aft hatches coaming to machinery space severely wasted and holed. Stability problem and engine room floading.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 November 2010
No resolution recorded
Found engine room forward bulkhead with major rust in several location, crack lower port of escape ladder, improper penetration of the bulkhead where hydraulic line passes. Water tight problem.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 November 2010
No resolution recorded
Found (02) main batteries stored in aft engine room on steel deck. Lost of electrical power and electrical hazard.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 17 November 2010
No resolution recorded
Found forward engine room bilge with estimate (02) gallons of oily water. Fire hazard and environement pollution.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 November 2010
No resolution recorded
Found deteriorated & rusted piping on bilge pump system in the engine room. Engine room floading.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 November 2010
No resolution recorded
Found wasted and holed areas around port and starboard engine's exhaust discharge. Engine room floading.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 17 November 2010
No resolution recorded
Found deteriorated and cracked on all flexible hoses on Jacket water system. Engine overheat and lose of propulsion.
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 November 2010
No resolution recorded
Found salt water suctions from the sea chest with deteriorated over expanded non-metallic hose. Engine room floading.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 17 November 2010
No resolution recorded
Found cracked non-metallic hose attached to secondary fuel filter secured with wire instead of hose clamps on both propulsion engines. Fuel leak and fire hazard.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 November 2010
No resolution recorded
Found exhaust manifold on both prolusion engines with severe rust and waste around manifold’s nuts and bolts. Engine room floading and exhaust smoke hazard.
Engineering › Lubricating Oil Service System › Cooler
Issued 17 November 2010
No resolution recorded
Found the under side of the oil cooler on both propulsion engines with major waste and deterioration. Major engine overheat.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 17 November 2010
No resolution recorded
Found oil leaks in forward gears case and aft flywheel areas on both propulsion engines. Fire hazard and environment pollution.
Lifesaving › Lifefloat › Paddle
Issued 17 November 2010
Resolved
Found (02) lifefloat's Paddles not marked. Stencil the vessel's name on the each paddle.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 25 August 2006
Resolved
Found vessel missing required Licensed mate. Prove vessel has required manning.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 25 August 2006
Resolved
Found vessel missing Crew List. Prove vessel has Crew List.
Personnel › Manning/Qualifications › Medical Fitness
Issued 25 August 2006
Resolved
Found crew was unable to prove medical fitness. Prove medical fitness of crew.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 25 August 2006
Resolved
Found wooden hand made ladder leading to cargo area. Install proper metal stairs with handrails from main deck to cargo area.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 25 August 2006
Resolved
Found vessel missing pier boarding ladder. Install pier side boarding ladder.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 August 2006
Resolved
Found main engine alternator missing guard. Install safety guard on alternator.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 August 2006
Resolved
Found vessel missing a Waste Management Plan. Prove vessel has an operational Waste Management Plan.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 August 2006
Resolved
Found vessel had no Waste Management Plan education program. Train crew on Waste Management Plan.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 August 2006
Resolved
Found vessel missing CG Light List. Prove vessel has current CG light List.
Navigation › Piloting/Steering › Marine Charts
Issued 25 August 2006
Resolved
Found Marine Charts not current. Prove vessel has current charts.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 25 August 2006
Resolved
Found vessel missing tide/current table. Prove vessel has current tide/current tables.
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 August 2006
Resolved
Found vessel missing US Coast Pilot. Prove vessel has current US Coast Pilot.
Navigation › Collision/Grounding Avoidance › Lead Line
Issued 25 August 2006
Resolved
Found vessel had not depth of water measuring device. Prove vessel can measure depth of water.
Communications › Audible Communications › Bell
Issued 25 August 2006
Resolved
Found vessel missing bell. Prove vessel has audible communication bell.
Lifesaving › Hand Flares › Quantity
Issued 25 August 2006
Resolved
Found vessel missing 3 orange smokes and 3 red flares. Prove vessel has proper quantity of hand flares.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 August 2006
Resolved
Found vessel missing Navigational Light Indicator Panel. Install Navigational Light Indicator Panel.
Construction/Loadline › Hull › Bottom Plating
Issued 25 August 2006
Resolved
Found vessel unable to provide hull gauging report from last dry-dock. Provide hull gauging report w/original thicknesses.
Construction/Loadline › Penetrations › Pipe Flange
Issued 25 August 2006
Resolved
Found bilge overboard hose missing valve. Install shutoff valve to bilge overboard.
Fire Fighting › Fire Pumps › Arrangement
Issued 25 August 2006
Resolved
Found emergency fire pump not operating properly. Prove proper operation of fire pump.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 25 August 2006
Resolved
Found fuel supply line to fire pump motor not an approve type. Repair fuel supply line with an approved type.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 25 August 2006
Resolved
Found fire pump mounting bracket worn. Repair or replace worn bracket.
Fire Fighting › Fire Main › Condition
Issued 25 August 2006
Resolved
Found fire main supply lines from fire pump with soft patches. Crop and renew as original.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 25 August 2006
Resolved
Found portable fire extinguisher not annually serviced. Service fire extinguishers.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 25 August 2006
Resolved
Found bilge pump discharge piping of not an approved material. Replace hose with approved metal piping.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 August 2006
Resolved
Found excess oil water in bilge. Properly remove all excess oil/water from bilge and retain receipt.
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 25 August 2006
Resolved
Found soft patch in way of keel cooler STBD side main engine. Crop and renew as original keel cooler piping.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 25 August 2006
Resolved
Found STBD main engine excessively smoking from the underside of the engine. Make permanent repairs to STBD engine.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 August 2006
Resolved
Found vessel fuel tanks missing emergency shutdown reach rods outside the engine room. Prove the vessel can remotely secure fuel from fuel tanks.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 25 August 2006
Resolved
Found vessel did not have adequate anchor rope. Prove vessel has proper length of rope or line to safety anchor vessel.
Operations/Management › Drills/Instruction › Fire
Issued 25 August 2006
Resolved
Prove vessel can abandon ship and fight fire onboard.
Personnel › Training › Cargo Safety
Issued 25 August 2006
Resolved
Found vessel was unable to prove HAZMAT training. Prove crew is properly trained in HAZMAT.
Lifesaving › Emergency Outfit › Boots
Issued 5 December 2001
Resolved
Company hazmat employee does not have job specific training in non- adherence with 49 CFR 172 Subpart H.
Lifesaving
Issued 5 December 2001
Resolved
200+ gallons of oil, debris, and water in cargo hold creating increased risk of pollution incident and personnel injury (ILO 147).
Electrical
Issued 5 December 2001
Resolved
Numerous deadended and poorly connected wiring at operating station. 33 CFR6.
Deck/Cargo
Issued 5 December 2001
Resolved
Stowage of compressed gas cylinders not in accordance with 49 CFR 176.200.
Documentation
Issued 5 December 2001
Resolved
Safe Manning Certificate expired 03SEP01.
Navigation
Issued 5 December 2001
Resolved
Navigation Lights inoperable due to faulty wiring and other reasons in non-adherence with International COLREGS.
Documentation
Issued 5 December 2001
Resolved
Master's license expired in non-adherence with STCW.
Navigation
Issued 5 December 2001
Resolved
Ship's horn inoperable in non-adherence with the International COLREGS.
Lifesaving
Issued 5 December 2001
Resolved
EPIRB not operable due to fractured housing and damaged antenna.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.