Documentation record
Registered dimensions (L × B × D)109.6 ft × 51.2 ft × 15.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNICHOLS BROS.BOAT BUILDER · FREELAND, WA, UNITED STATES · built 1989
Hull materialAluminum
PropulsionJet Drive
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW LONDON, CT
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 3 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 22 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 22
9 June 2026
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8394671
3 September 2025
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8225854
28 May 2025
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8146526
5 June 2024
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7927523
1 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7702061
3 April 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7659865
15 June 2021
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7221137
7 May 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7188905
20 November 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7099013
6 July 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6998348
3 September 2019
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6802484
2 September 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6814700
9 July 2019
MTSA Verification · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6741779
3 June 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6704292
26 June 2018
MTSA Verification · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6458187
3 April 2018
Internal Structural Exam · Plan Review (Other than "T") · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6384357
17 March 2017
MTSA Verification · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6106545
14 April 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5851878
7 April 2016
Examination of Repairs · Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5849469
6 April 2016
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5916709
7 March 2016
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5829471
12 January 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5796122
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2026
Resolved
Renew port and STBD emergency fuel shutoff pull cables.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2026
Resolution: New cables installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2026
Resolved
Lable emergency fuel shutoff valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2026
Resolved 10 June 2026
Resolution: New placards made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 June 2026
Resolved
Prove proper operation of bilge high level alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2026
Resolution: New bilge float installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 June 2026
Resolved
FCC station licence expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2026
Resolved 9 June 2026
Resolution: Operator provided valid FCC station licence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2023
Resolved
Label adult PFD stowage in main cabin stbd side midships (2 lockers) & upper cabin stbd side fwd)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 5 June 2023
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2023
Resolved
Provide type II retro tape for ring bouy on top deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 1 June 2023
Resolution: Completed.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 1 June 2023
Resolved
Clean Ice maker. Excessive mold found.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 5 June 2023
Resolution: Completed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 June 2023
Resolved
Provide current tide tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 1 June 2023
Resolution: Completed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2023
Resolved
Replace portable fire extinguisher bracket on stbd side wheel house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 5 June 2023
Resolution: Completed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 9 July 2019
Resolved
De-water and clean the PORT and STBD jet rooms and STBD engine room
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 31 July 2019
Resolution: All spaces cleaned and dewatered.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2019
Resolved
Make permanent repairs stbd M/E cylinder #5. The cylinder is leaking jacket water and oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 31 July 2019
Resolution: Cylinder liner replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 July 2019
Resolved
Repair or replace port and stbd engine room high water alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 31 July 2019
Resolution: High water alarms replaced and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2019
Resolved
Make permanent repairs to stbd shaft seal in jet room. The dripless seal was leaking causing water to accumulate in the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 31 July 2019
Resolution: Shaft seal tightened.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 July 2019
Resolved
Prove proper operation of port and stbd fire pumps. Each pump was only capable of producing 25 to 30 PSI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2019
Resolved 31 July 2019
Resolution: Fire pump replaced and tested.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 April 2017
Resolved
Repair latch on breaker panel door #8, Port engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 11 April 2017
Resolution: Latch repaired.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 3 April 2017
Resolved
Repair aft fire damper to port engine room.
Condition: Improper/Lack of Maintenance
Due 3 May 2017
Resolved 11 April 2017
Resolution: Damper repaired.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 3 April 2017
Resolved
Secure radar electrical boxes under pilot house console.
Due 3 May 2017
Resolved 11 April 2017
Resolution: Boxes secured.
Electrical › Electric Supply System (service) › Cable
Issued 3 April 2017
Resolved
Remove dead-end wires under pilot-house console.
Condition: Improper/Lack of Maintenance
Due 3 May 2017
Resolved 11 April 2017
Resolution: Wires removed.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 3 April 2017
Resolved
Seal cable penetration on forward bulkhead, void #2
Condition: Improper Installation
Due 3 May 2017
Resolved 11 April 2017
Resolution: Penetrations sealed.
Communications › Alarms/Indicators › Fire Alarm
Issued 3 April 2017
Resolved
Indentify source of trouble alarm on fire detection panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 April 2017
Resolution: Trouble alarm caused by unused control module in central panel box. Parts are no longer availible. As vessel is certificated under old T-L,fire dectection is not required. Vessel POC plans top renew system with ANSUL Check Fire at the end of the season
Construction/Loadline › Structures › Scuttle
Issued 14 April 2016
Resolved
Renew port jet room scuttle.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 17 April 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 April 2016
Resolved
Repair sheared bracket on the stbd engine exhaust cooling piping.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 17 April 2017