MAURY USCG vessel records
← All vessels

DOLE ECUADOR

DOLE ECUADOR is a 1988 freight ship. The Coast Guard has recorded 47 inspections since 2016, most recently in June 2021, along with 14 deficiencies and 1 operational control.

Records from 2016 to 2021. Most recent: inspection, 28 June 2021.

Built
1988
Last inspected
28 June 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 June 2021
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8513479
328525
Flag
BAHAMAS, THE
Maury page id
psix-328525

Documentation record

Tonnage as PSIX records it16488 - Convention (Subpart B), Gross Ton
4946 - Convention (Subpart B), Net Ton
24875 - Displacement, Ton
16300 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

47 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 47

28 June 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7234677
8 April 2021 PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7170838
25 March 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7163385
24 March 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7161817
18 September 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7060939
10 March 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6923671
23 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6840324
8 October 2019 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6830348
22 September 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6817669
20 May 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6688341
10 April 2019 PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6659452
12 February 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6624300
3 September 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6530775
3 August 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6499894
2 August 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6498838
6 July 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6469147
22 June 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6452295
9 June 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6438624
25 May 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6423259
7 May 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6408257
30 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6402289
15 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6391757
1 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6382706
17 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6373489
1 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6363765
17 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6356721
3 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6348882
19 January 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6339875
20 December 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6327000
11 December 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6322015
26 November 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6312687
29 October 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6296922
16 October 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6288617
2 October 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6279403
17 September 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6268272
21 August 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6247073
24 July 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6219593
11 July 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6205027
28 May 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6158141
15 May 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6146260
17 April 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6126185
17 April 2017 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6221448
9 January 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6065899
23 November 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6046191
11 July 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5936525
1 July 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5925629
17 May 2016 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5879258

Deficiency record · 14

10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 8 April 2021 Resolved
All ships of 500 gross tonnage and upwards shall...have...rudder...indicators vessel was found with an inoperable rudder angle indicator. Crew replaced broken screw inside indicator gear.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 April 2021
Resolved 8 April 2021
Resolution: Coast guard and classification society satisfied with repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 March 2021 Resolved
ALL LIFESAVING APPLIANCES SHALL BE KEPT IN WORKING ORDER AND AVAILABLE FOR IMMEDIATE USE BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE. PSCO FOUND A CRACKED AND LEAKING WINDOW ON THE UPPER FORWARD HATCH OF THE STARBOARD SIDE LIFEBOAT
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 7 April 2021
Resolution: Classification society came onboard and rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2021 Resolved
EXPOSED METAL PARTS OF ELECTRICAL MACHINES OR EQUIPMENT WHICH ARE NOT INTENDED TO BE LIVE BUT WHICH ARE LIABLE UNDER FAULT CONDITIONS TO BECOME LIVE SHALL BE EARTHED. PSCO OBSERVED A BROKEN GROUNDING WIRE ON A CONTROL PANEL FOR THE MAIN ENGINE.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: DEFICIENCY RECTIFIED ON THE SPOT
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 March 2021 Resolved
HYDRAULIC POWER OPERATED STEERING GEAR SHALL BE PROVIDED WITH A FIXED STORAGE TANK HAVING SUFFICIENT CAPACITY TO RECHARGE AT LEAST ONE POWER ACTUATING SYSTEM INCLUDING THE RESERVOIR. VESSEL IS REQUIRED TO HAVE THE STORAGE TANK AT 80% CAPACTIY TO RECHARGE SYSTEM, PSCO OBSERVED STORAGE TANK AT 50% CAPACITY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: DEFICIENCY RECTIFIED ON THE SPOT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 March 2021 Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE VAPORS ARE LIKELY TO COLLECT UNLESS THAT EQUIPMENT IS CERTIFIED FOR SAFE USAGE IN THE VAPORS LIKELY TO BE ENCOUNTERED. PSCO OBSERVED AN EXPLOSION PROOF LIGHTING FIXTURE THAT WAS CRACKED, LIGHTING FIXTURE WAS LOCATED IN ACETYLENE STORAGE ROOM.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: DEFICIENCY RECTIFIED ON THE SPOT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2021 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. A REMOTE CONTROL VALVE ON THE BALLAST SYSTEM IN THE FORWARD PART OF THE ENGINE ROOM WAS FOUND DISCONNECTED AND CREW WAS MANUALLY CONTROLLING THE VALVE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 7 April 2021
Resolution: Classification society came onboard and rectified deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported a loss of propulsion while getting underway. 74 SOLAS (14) I/11.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 April 2021
Resolution: 25MAR21: Received documentation from RINA with causal analysis and rectification of the deficiency. Main engine was tested with a series of three ahead and astern commands, to the satisfaction of the attending class surveyor. Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 September 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel had a fire on generator #5 causing the generator to be inoperable. 74 SOLAS (2014) I/11(b) Def's due date to be reflected by the expiration date of the short term CSSC.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2019
Resolved 22 October 2019
Resolution: Vessel submitted class report certifying repair of Generator #5.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 22 September 2019 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Electrical wiring in vicinity of generator #5 is charred/burned from fire. 74SOLAS(81 amend) II-1/40.1.3
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2019
Resolution: Class report stating that the damaged electrical wiring affecting the space around the gen #5. Class assessed and cleared the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 February 2019 Resolved
All the life saving appliances shall be kept in working order and available for immediate use. The port and starboard lifeboats were found incapable of launching from inside the lifeboats.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 12 February 2019
Resolved 13 February 2019
Resolution: Received a class report from RINA. See the documents section.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 February 2019 Resolved
All the life saving appliances shall be kept in working order and available for immediate use. Propeller did not engage when perfomring operational test of Port Lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 February 2019
Resolved 12 February 2019
Resolution: PSCO varified proper operation.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 11 July 2017 Resolved
1099-An alarm system shall be provided indicating any fault requiring attention and shall: be capable of sounding an audible alarm in the main machinery control room or at the propulsion machinery control position, and indicate visually each seperate alarm function at a suitable position. Bilge alarms in E/R are inoperable. 74 SOLAS (81) II-1/51.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2017
Resolution: Receivd Class Survey Report attesting to deficiency
Construction/Loadline › Markings › Load Line Mark
Issued 11 July 2017 Resolved
1299 - The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The load line marks are painted blue.ICLL (2005) 8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2017
Resolution: Receivd Class Survey Report attesting to deficiency
Engineering › Lubricating Oil Service System › Pump
Issued 17 April 2017 Resolved
SOLAS 74(14) I/11(a) Vessel had a loss or propulsion due to a malfunction of the lube oil pump.Prior to MOVEMENT 60ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2017
Resolution: Class report

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.