MAURY USCG vessel records Sign in
← All vessels

DOLE ECUADOR

DOLE ECUADOR is a 1988 freight ship. The Coast Guard has recorded 122 inspections since 1989, most recently in June 2021, along with 33 deficiencies and 2 operational controls.

Records from 1989 to 2021. Most recent: inspection, 28 June 2021.

Built
1988
Last inspected
28 June 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8513479 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
328525
Flag
BAHAMAS, THE
—
Maury page id
psix-328525

Inspections, by type

…with no type recorded62
Years with a record 30 calendar years (1989–2021)
The 122 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it16488 - Convention (Subpart B), Gross Ton
4946 - Convention (Subpart B), Net Ton
24875 - Displacement, Ton
16300 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 122

28 June 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7234677
8 April 2021 PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7170838
25 March 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7163385
24 March 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7161817
18 September 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7060939
10 March 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6923671
23 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6840324
8 October 2019 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6830348
22 September 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6817669
20 May 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6688341
10 April 2019 PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6659452
12 February 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6624300
3 September 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6530775
3 August 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6499894
2 August 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6498838
6 July 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6469147
22 June 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6452295
9 June 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6438624
25 May 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6423259
7 May 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6408257
30 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6402289
15 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6391757
1 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6382706
17 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6373489
1 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6363765
17 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6356721
3 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6348882
19 January 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6339875
20 December 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6327000
11 December 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6322015
26 November 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6312687
29 October 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6296922
16 October 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6288617
2 October 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6279403
17 September 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6268272
21 August 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6247073
24 July 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6219593
11 July 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6205027
28 May 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6158141
15 May 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6146260
17 April 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6126185
17 April 2017 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6221448
9 January 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6065899
23 November 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6046191
11 July 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5936525
1 July 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5925629
17 May 2016 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5879258
28 December 2015 MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex VI Survey · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5788464
9 June 2014 Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4878353
6 February 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4236298
10 September 2010 MARPOL Annex I Examination · NPV Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3847070
16 December 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3378696
7 July 2008 ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3257755
26 March 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3171685
10 December 2007 Random ISPS/MTSA/PSC · Loadline Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3110858
17 September 2007 ISM Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3060031
17 July 2007 Ballast Water Examination · MARPOL Annex V Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2993798
22 May 2006 Random ISPS/MTSA/PSC · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2650990
9 April 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2620347
7 September 2005 Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2486633
18 June 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2394820
24 January 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2280231
2 January 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2267525
22 November 2004 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2317495
2 November 2004 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2233417
31 October 2004 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2231716
15 September 2004 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2196808
29 June 2004 ISPS II Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2115378
29 June 2004 Type not recorded
No type recorded · ACTIVITIES SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2115798
27 June 2004 Type not recorded
No type recorded · ACTIVITIES SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2113025
20 May 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2073041
17 March 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2026308
15 March 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2024823
15 March 2004 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2025102
24 August 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1886664
22 August 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1883779
23 July 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1856729
4 July 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1838472
2 July 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1833251
24 May 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1802630
21 May 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1798305
12 April 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1772532
10 April 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1771483
22 March 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1762755
21 March 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1758939
20 March 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1762749
15 March 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1758994
1 March 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1751337
27 February 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1750391
9 February 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1743008
6 February 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1741329
18 January 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1732261
16 January 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1731703
13 January 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1741036
28 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1723932
26 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1723370
6 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1715614
15 November 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1706043
30 October 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1699611
26 October 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1696513
11 March 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 288017
3 March 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275471
7 March 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 426284
2 March 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 413319
11 March 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 401467
20 March 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 389277
1 April 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 376884
4 December 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 373066
5 November 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 453304
9 July 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 173833
19 May 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 676605
18 May 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 358375
7 January 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 438468
18 March 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 349577
10 January 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 351910
20 September 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 531124
12 May 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1237605
25 March 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 342666
16 October 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 534109
18 March 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 335909
11 November 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 501002
30 March 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 329374

Deficiency record · 33

10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 8 April 2021 Resolved
All ships of 500 gross tonnage and upwards shall...have...rudder...indicators vessel was found with an inoperable rudder angle indicator. Crew replaced broken screw inside indicator gear.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 April 2021
Resolved 8 April 2021
Resolution: Coast guard and classification society satisfied with repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 March 2021 Resolved
ALL LIFESAVING APPLIANCES SHALL BE KEPT IN WORKING ORDER AND AVAILABLE FOR IMMEDIATE USE BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE. PSCO FOUND A CRACKED AND LEAKING WINDOW ON THE UPPER FORWARD HATCH OF THE STARBOARD SIDE LIFEBOAT
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2021
Resolved 7 April 2021
Resolution: Classification society came onboard and rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2021 Resolved
EXPOSED METAL PARTS OF ELECTRICAL MACHINES OR EQUIPMENT WHICH ARE NOT INTENDED TO BE LIVE BUT WHICH ARE LIABLE UNDER FAULT CONDITIONS TO BECOME LIVE SHALL BE EARTHED. PSCO OBSERVED A BROKEN GROUNDING WIRE ON A CONTROL PANEL FOR THE MAIN ENGINE.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: DEFICIENCY RECTIFIED ON THE SPOT
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 March 2021 Resolved
HYDRAULIC POWER OPERATED STEERING GEAR SHALL BE PROVIDED WITH A FIXED STORAGE TANK HAVING SUFFICIENT CAPACITY TO RECHARGE AT LEAST ONE POWER ACTUATING SYSTEM INCLUDING THE RESERVOIR. VESSEL IS REQUIRED TO HAVE THE STORAGE TANK AT 80% CAPACTIY TO RECHARGE SYSTEM, PSCO OBSERVED STORAGE TANK AT 50% CAPACITY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: DEFICIENCY RECTIFIED ON THE SPOT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 March 2021 Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE VAPORS ARE LIKELY TO COLLECT UNLESS THAT EQUIPMENT IS CERTIFIED FOR SAFE USAGE IN THE VAPORS LIKELY TO BE ENCOUNTERED. PSCO OBSERVED AN EXPLOSION PROOF LIGHTING FIXTURE THAT WAS CRACKED, LIGHTING FIXTURE WAS LOCATED IN ACETYLENE STORAGE ROOM.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: DEFICIENCY RECTIFIED ON THE SPOT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2021 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. A REMOTE CONTROL VALVE ON THE BALLAST SYSTEM IN THE FORWARD PART OF THE ENGINE ROOM WAS FOUND DISCONNECTED AND CREW WAS MANUALLY CONTROLLING THE VALVE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2021
Resolved 7 April 2021
Resolution: Classification society came onboard and rectified deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported a loss of propulsion while getting underway. 74 SOLAS (14) I/11.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 April 2021
Resolution: 25MAR21: Received documentation from RINA with causal analysis and rectification of the deficiency. Main engine was tested with a series of three ahead and astern commands, to the satisfaction of the attending class surveyor. Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 September 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel had a fire on generator #5 causing the generator to be inoperable. 74 SOLAS (2014) I/11(b) Def's due date to be reflected by the expiration date of the short term CSSC.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2019
Resolved 22 October 2019
Resolution: Vessel submitted class report certifying repair of Generator #5.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 22 September 2019 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Electrical wiring in vicinity of generator #5 is charred/burned from fire. 74SOLAS(81 amend) II-1/40.1.3
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2019
Resolution: Class report stating that the damaged electrical wiring affecting the space around the gen #5. Class assessed and cleared the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 February 2019 Resolved
All the life saving appliances shall be kept in working order and available for immediate use. The port and starboard lifeboats were found incapable of launching from inside the lifeboats.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 12 February 2019
Resolved 13 February 2019
Resolution: Received a class report from RINA. See the documents section.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 February 2019 Resolved
All the life saving appliances shall be kept in working order and available for immediate use. Propeller did not engage when perfomring operational test of Port Lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 February 2019
Resolved 12 February 2019
Resolution: PSCO varified proper operation.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 11 July 2017 Resolved
1099-An alarm system shall be provided indicating any fault requiring attention and shall: be capable of sounding an audible alarm in the main machinery control room or at the propulsion machinery control position, and indicate visually each seperate alarm function at a suitable position. Bilge alarms in E/R are inoperable. 74 SOLAS (81) II-1/51.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2017
Resolution: Receivd Class Survey Report attesting to deficiency
Construction/Loadline › Markings › Load Line Mark
Issued 11 July 2017 Resolved
1299 - The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The load line marks are painted blue.ICLL (2005) 8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2017
Resolution: Receivd Class Survey Report attesting to deficiency
Engineering › Lubricating Oil Service System › Pump
Issued 17 April 2017 Resolved
SOLAS 74(14) I/11(a) Vessel had a loss or propulsion due to a malfunction of the lube oil pump.Prior to MOVEMENT 60ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2017
Resolution: Class report
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 10 June 2014 Resolved
2515- Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship, the master or owner of the ship shall notify the Administration at the earliest opportunity. The ship was unable to use the # 1 SW pump for 5 days before class was notified. The master notified the company (as per the SMS) but the company did not pass along the non- conformity.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 July 2014
Resolution: Class was notified, and will access the findings at next survey.
Engineering › Sea-water System (primary cooling) › Pump
Issued 9 June 2014 Resolved
The machinery boilers and other pressure vessels, associated piping system and fittings shall be of a design construction adequate for the service or which they are intended. The number 1 freshwater pump has been secured due to a crack in the discharge line. SOLAS 74 (81 Amended) CH II-I Reg 26.1. (17A)
Action required: 705 - Other - as specified
Due 11 June 2014
Resolved 10 June 2014
Resolution: Received class report attesting to the repairs. Cracked welding has now been gouged and re-welded. The pipe has been pressure tested. No 1 sea water pump is now back in operation.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 June 2014 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. Several of the flow and temperature pressure sensors on the main engine were missing covers. Instead they were covered with plastic bags which were covered in oil. SOLAS 74 (81 Amended) CH II-I Reg 45.1.3 (17C)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 10 June 2014
Resolution: All the sensors were properly installed.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 9 June 2014 Resolved
Each magnetic compass shall be properly adjusted. From the main conning position to the steering room there was a 94 degree difference. SOLAS 74 (01 Cons.) Ch 5 Reg 12 (b) (ii) (10C)
Due 10 June 2014
Resolved 9 June 2014
Resolution: Gyro compas was synced succesfully
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 9 June 2014 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Most of the engine room and its equipment were found to be covered in oil on the bottom deck. SOLAS 74 (09 Cons) Ch 1 Reg 11(a) (40C)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 June 2014
Resolution: During the follow up inspection, the engine room was found to be in substantial compliance, with regards to the cleanliness.
Engineering › Fuel Oil Service System › Piping
Issued 1 February 2012 Resolved
The piping for Main Diesel Generator #8 shall be of design that is adequate for service. The fuel oil line has temporary repairs. Class is to verify temp repairs and shield w/ DNV pressure tape. SOLAS 74 (81cons.) Chap II-1 reg 26.1. 40b.
Action required: 705 - Other - as specified
Resolved 7 February 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 1 February 2012 Resolved
At each location there shall be instructions relating to the operation of CO2 system. The scavange space did not have said instructions. SOLAS 74 (81 cons.) Chap II-2 reg 5.1.7. 10c.
Action required: 705 - Other - as specified
Resolved 6 February 2012
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 December 2008 Resolved
Found emergency generator inoperable due to leaking fuel intake line. Engineers repaired on the spot.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2008
Resolved 16 December 2008
Resolution: Replaced leaking part.
Fire Fighting › Fire Main › Condition
Issued 17 July 2007 Resolved
Mechanical seal on emergency fire pump leaking. Repair/replace prior to next US port after sailing foreign.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 July 2007
Resolved 6 August 2007
Resolution: mechanical seal replaced. inspected satisfactory
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 July 2007 Resolved
Excess oil in engine room. Clean up and remove.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 August 2007
Resolution: inspected satisfactory
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 17 July 2007 Resolved
Cover on the side of sewage tank leaking and missing bolts. Repair cover and replace bolts
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 August 2007
Resolution: inspected leaking tank. repairs were made, bolts replaced. inspected satisfactory
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 July 2007 Resolved
Fuel oil heater insulation soaked in oil. Replace insulation
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 August 2007
Resolution: insulation replaced satisfactory.
Deck/Cargo › Holds/Tanks › Coaming
Issued 2 November 2004 Resolved
Cargo hold coaming corner brackets within the mid-body of the ship are fractured and/or wasted from corrosion. Provide class report on condition/repair of all cargo coaming brackets. OBSERVATION: There appears to be a lack of maintenace of the cargo deck structure. Excessive amounts of corrosion were observed. Recommend company improve maintenace procedures onboard vessel.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 November 2004
Engineering › Steering Gear System
Issued 21 March 2003 Resolved
Rudder angle indicator off greater than two degrees. Calibrate prior to next U.S. port of call. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 15 - Rectify deficiencies by next port
Resolved 3 July 2003
Resolution: RAI is within limits.
Navigation
Issued 18 May 1993 Resolved
FAILURE TO NOTIFY COTP OF AN INOPERABLE ARPA RADAR BEFORE ENTERING LA/LB HARBOR.
Condition: Unknown
Due 18 May 1993
Resolved 19 May 1993
Navigation
Issued 18 May 1993 Resolved
ARPA RADAR INOPERABLE.
Condition: Unknown
Due 18 May 1993
Resolved 19 May 1993
Navigation
Issued 18 March 1992 Resolved
VESSELS COMPASS DEVIATION TABLE WAS NOT CURRENT.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Navigation
Issued 18 March 1992 Resolved
VESSSELS N.O.S. CHARTS 18720, AND 18751 WERE NOT CORRECTED TO DATE.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Documentation
Issued 30 March 1989 Resolved
OIL TRANSFER PROCEDURES AS DISCRIBED IN 33CFR155.750 ONLY CONTAINED LINE DIAGRAM. WRITTEN PORTION OF PROCEDURES WERE MISSING AND ARE REQUIRED BY 33CFR155.740
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.