MAURY USCG vessel records Sign in
← All vessels

VAGABOND

VAGABOND is a 1973 freight ship. The Coast Guard has recorded 25 inspections since 1992, most recently in September 1997, along with 71 deficiencies and 3 operational controls.

Records from 1992 to 1997. Most recent: inspection, 11 September 1997.

Built
1973
Last inspected
11 September 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

329040
Flag
PANAMA
—
Maury page id
psix-329040

Inspections, by type

…with no type recorded24
Years with a record 5 calendar years (1992–1997)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it1 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

11 September 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 407792
28 August 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 407329
19 August 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 407154
7 August 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 406379
7 July 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 405462
17 March 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 401556
11 December 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 398478
16 November 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 397715
11 May 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 391145
25 March 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 709171
22 March 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 87737
15 June 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 379568
20 April 1995 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1430029
4 April 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 143723
30 January 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 374776
20 January 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 374475
7 June 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 668331
18 May 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 668332
14 May 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 358728
30 April 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 358359
2 April 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 668330
2 April 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 668333
10 March 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 357353
1 March 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 357352
30 August 1992 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 42208

Deficiency record · 71

Accommodation/Occupational Safety
Issued 19 August 1997 Resolved
CLEAN DECK PLATES IN ENGINE ROOM, KEEP THEM FREE OF OIL.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Engineering
Issued 19 August 1997 Resolved
REPAIR BROKEN BRACKET OF OIL COOLER OF PORT ENGINE.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Engineering
Issued 19 August 1997 Resolved
PROVIDE OIL TRANSFER PROCEDURES BEFORE DO ANY TRANSFER IN U.S. WATERS.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Fire Fighting
Issued 19 August 1997 Resolved
PROVIDE AN OIL RECORD BOOK.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Navigation
Issued 19 August 1997 Resolved
REPLACE MISSSING NUT OUT OF RUDDERD PACKING GLAND FLANGE.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Fire Fighting
Issued 19 August 1997 Resolved
PROVIDE PROOF THAT THE FIXED HALON SYSTEM WORKS. PROVIDE COPY OF CLAAS REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Electrical
Issued 19 August 1997 Resolved
REPLACE MISSING LIGHT COVERS THROUGOUT THE SHIP. RE-ISSUED FOR SECOND TIME.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Engineering
Issued 19 August 1997 Resolved
RENEW BROKEN LUBE OIL STOWAGE TANK SIGHT GLASS. THIS DEFICIENCY WAS RE- ISSUED FOR SECOND TIME.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Fire Fighting
Issued 7 July 1997 Resolved
EXCESSIVE WATER FROM FIRE PUMP PACKING GLAND. RENEW PACKING MATERIAL.
Condition: Unknown
Due 8 July 1997
Resolved 21 July 1997
Deck/Cargo › Ballast › Segregated Ballast Tank
Issued 7 July 1997 Resolved
MAKE PERMANENT REPAIRS TO #5 PORT/STBD BALLAST TANK AND #3 STBD BALLAST TANK IN WAS OF WELDED TEMP DOUBLERS LOCATED ON BULKHEAD IN E/R ALLEY ACCESS. REPAIRS WILL BE MADE AT NEX DRY DOCK. MUST HAVE COMPLETED REPAIRS NO LATER THAN 30 JAN 98.
Condition: Unknown
Due 30 January 1998
Resolved 5 October 2004
Resolution: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation
Issued 7 July 1997 Resolved
RENEW OR REPAIR BENT RUDDER POST, ENSURE WATER TIGHT.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Lifesaving
Issued 7 July 1997 Resolved
HAVE LIFERAFTS SERVICED AT AUTHORIZED LIFERAFT SERVICE FACILITY.
Condition: Unknown
Due 8 July 1997
Resolved 21 July 1997
Accommodation/Occupational Safety
Issued 7 July 1997 Resolved
FREE UP AND REPAIR EMERGENCY ESCAPE HATCH ON MAIN DECK FROM ENGINE ROOM.
Condition: Unknown
Due 8 July 1997
Resolved 21 July 1997
Electrical
Issued 7 July 1997 Resolved
INSTALL RUBBER MAT IN FRONT OF ELECTRICAL SWITCHBOARD.
Condition: Unknown
Due 8 July 1997
Resolved 21 July 1997
Engineering
Issued 7 July 1997 Resolved
REPAIR HOLED WATER EXPANSION TANK ON STARBOARD ENGINE.
Condition: Unknown
Due 28 August 1997
Resolved 25 August 1997
Electrical
Issued 7 July 1997 Resolved
REPLACE MISSING LIGHT COVERS THROUGHOUT SHIP.
Condition: Unknown
Due 28 August 1997
Resolved 25 August 1997
Engineering
Issued 7 July 1997 Resolved
REPAIR BROKEN REMOTE FUEL TANK CUT OFF VALVE.
Condition: Unknown
Due 28 August 1997
Resolved 25 August 1997
Engineering
Issued 7 July 1997 Resolved
RENEW BROKEN LUBE OIL STOWAGE TANK SIGHT GLASS.
Condition: Unknown
Due 28 August 1997
Resolved 25 August 1997
Fire Fighting
Issued 7 July 1997 Resolved
PROVIDE INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 7 July 1997 Resolved
LOOSEN SEIZED DOGS ON DOOR IN ENGINE ROOM LEADING TO EMERGENCY ESCAPE.
Condition: Unknown
Due 8 July 1997
Resolved 21 July 1997
Fire Fighting
Issued 7 July 1997 Resolved
MAIN VALVE DOWNSTREAM OF FIRE PUMP WASTED, HOLED. REPAIR OR RENEW.
Condition: Unknown
Due 8 July 1997
Resolved 21 July 1997
Unknown
Issued 17 March 1997 Resolved
MAKE PERMANENT REPAIRS TO #5 PORT/STBD BALLAST TANK AND #3 STBD BALLAST TANK IN WAY OF WELDED TEMP DOUBLERS LOCATED ON BULKHEAD IN E/R ALLEY ACCESS. REPAIRS WILL BE MADE AT NEXT DRY DOCK. MUST HAVE COMPLETED REPAIRSNO LATER THAN 30 JUNE 1997.
Condition: Unknown
Due 30 January 1998
Resolved 8 July 1997
Lifesaving
Issued 16 November 1996 Resolved
REPLACE LOWER RIGHT DOG ON WEATHER TIGHT DOOR AT ENTRANCE TO PILOT HOUSE ONPORT SIDE OF VESSEL AT NEXT DRYDOCK, BUT IN NO CASE LATER THAN 31JAN97. ALLREPAIRS MUST BE TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Deck/Cargo
Issued 16 November 1996 Resolved
REPAIR #4 STBD FUEL VENT TO SATISFACTION OF CLASS SOCIETY DURING NEXT DRYDOCKING PERIOD, BUT IN NO CASE LATER THAN 31JAN97.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Fire Fighting
Issued 16 November 1996 Resolved
REPAIR/REPLACE MAIN FIRE PUMP TO SATISFACTION OF CLASS SOCIETY PRIOR TO DEPARTURE.
Condition: Unknown
Due 20 January 1997
Resolved 20 January 1997
Fire Fighting
Issued 16 November 1996 Resolved
REPAIR/REPLACE ALL WASTED AREAS OF FIREMAIN AND PROVE PROPER OPERATION TO SATISFACTION OF CLASS SOCIETY PRIOR TO DEPARTURE.
Condition: Unknown
Due 20 January 1997
Resolved 20 January 1997
Construction/Loadline
Issued 16 November 1996 Resolved
MAKE PERMANANT REPAIRS TO #5 PORT/STBD BALLST TANKS AND #3 STARBOARD BALLAST TANK IN WAY OF WELDED TEMP DOULERS LOCATED ON BULKHEADS IN E/R ALLEY ACCESS. REPAIRS ARE TO BE MADE AT NEXT DRYDOCKING, BUT IN NO CASE LATER THAN 31JAN97. REPAIRS MUST BE TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Fire Fighting
Issued 11 May 1996 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS_x001C_ SOLAS CHAPT. 2, REG 57(d)
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Documentation
Issued 11 May 1996 Resolved
PROVIDE CURRENT TIDE/TIDE CURRENT TABLES._x001C_ 46 CFR 97.05(f)(g)
Condition: Unknown
Due 20 May 1996
Resolved 10 June 1996
Documentation
Issued 11 May 1996 Resolved
PROVIDE CURRENT INLAND NAVIGATIONAL RULES_x001C_ 33 CFR 88.05
Condition: Unknown
Due 20 May 1996
Resolved 10 June 1996
Navigation
Issued 11 May 1996 Resolved
SERVICE EPIRB_x001C_ 46 CFR 94.60/NAVIC9.93_x001C_ TO BE CORRECTED BY/BEFORE JUNE OF 1996.
Condition: Unknown
Due 1 June 1996
Resolved 10 June 1996
Construction/Loadline
Issued 11 May 1996 Resolved
REPAIR FRACTURES TO #5 BALLAST TANK, PORT AND STARBOARD _x001C_
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1996
Lifesaving
Issued 11 May 1996 Resolved
INSTALL COVERS ON ALL LIGHTS_x001C_ ILO
Condition: Unknown
Due 20 May 1996
Resolved 10 June 1996
Documentation
Issued 11 May 1996 Resolved
PROVIDE LICENSED CHIEF MATE_x001C_ STCW
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Fire Fighting
Issued 11 May 1996 Resolved
PROVE PROPER OPERATION OF FIRE PUMP_x001C_ SOLAS 60, CHAP 2, REG 56
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Unknown
Issued 11 May 1996 Resolved
MAKE PERMANENT REPAIRS TO MAIN DECK INWAY OF DAMAGE_x001C_ SOLAS CHAPT II-I, REG 19(1)
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Construction/Loadline
Issued 11 May 1996 Resolved
Restencil both port and starboard load-line markings.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Construction/Loadline
Issued 11 May 1996 Resolved
Locate repair wastage/fracture in bulkhead between #5 starboard aft ballasttank and adjacent diesel fuel tank. All repairs are to be completed to the satisfaction of the attending class surveyor. No ballast operations allowedin #5 stbd ballast tank until repairs completed.
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Fire Fighting
Issued 11 May 1996 Resolved
REPAIR ENGINE ROOM ESCAPE SCUTTLE HATCH
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Navigation
Issued 11 May 1996 Resolved
STARBOARD STEERING COMPARTMENT COVER NEEDS REPLACEMENT
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Construction/Loadline
Issued 11 May 1996 Resolved
REPAIR HOLD #3 STARBOARD BALLAST TANK _x001C_
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Fire Fighting
Issued 11 May 1996 Resolved
PROPERLY INSTALL FIXED FIRE EXTINGUISHING SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Deck/Cargo
Issued 11 May 1996 Resolved
PROPERLY REPAIR PORT WINDLASS BREAK
Condition: Unknown
Due 20 May 1996
Resolved 10 June 1996
Lifesaving
Issued 11 May 1996 Resolved
INSTALL WHISTLES AND LIGHTS ON LIFEJACKETS.
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Lifesaving
Issued 11 May 1996 Resolved
ENSURE ALL LIFERINGS REMOVABLE/ACCESSIBLE
Condition: Unknown
Due 11 May 1996
Resolved 10 June 1996
Documentation
Issued 11 May 1996 Resolved
MAKE CORRECTIONS TO CHARTS_x001C_ 46 CFR 97.05-5(a)
Condition: Unknown
Due 20 May 1996
Resolved 10 June 1996
Documentation
Issued 11 May 1996 Resolved
PROVIDE CURRENT U.S. COAST PILOT_x001C_ 46 CFR 97.05(c)
Condition: Unknown
Due 20 May 1996
Resolved 10 June 1996
Documentation
Issued 11 May 1996 Resolved
PROVIDE CURRENT U.S. LIGHT LIST_x001C_ 46 CFR 97.05(d)
Condition: Unknown
Due 20 May 1996
Resolved 10 June 1996
Fire Fighting
Issued 11 May 1996 Resolved
PROVIDE PROOF IN THROUGH A QUALIFIED TECHNICIANS REPORT THAT THE HALON FIREEXTINGUISHING SYSTEM WORKS. PROOF SHOULD INCLUDE: TEST OF TIME DELAY, ALARM, SHUTDOWNS AND RELEASE. (PIPING SHOULD BE AIR TESTED.
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Navigation
Issued 11 May 1996 Resolved
PROPERLY REPAIR #4 FUEL VENT, (STARBOARD)
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Lifesaving
Issued 11 May 1996 Resolved
REPLACE LOWER RIGHT DOG ON WEATHER TIGHT DOOR AT ENTRANCE TO PILOT HOUSE ONTHE PORT SIDE OF VESSEL.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Construction/Loadline
Issued 11 May 1996 Resolved
MAKE PERMANENT REPAIRS TO BALLAST TANKS #5 PORT AND STARBOARD AND #3 STARBOARD BALLAST TANKS. TO BE DONE AT NEXT DRY DOCK BUT NO LATER THAN 10JUN96.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Fire Fighting
Issued 11 May 1996 Resolved
MAKE PERMANENT REPAIRS TO HOLED FIRE MAIN PIPING IN ENGINE ROOM.
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Construction/Loadline
Issued 20 April 1995 Resolved
MAKE APPROPRIATE REPAIRS TO AFTER BULKHEAD OF FOREPEAK TANK IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE CLASSIFICATION SOCIETY OR FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 20 April 1995
Resolved 26 April 1995
Navigation
Issued 20 January 1995 Resolved
CHART #25640 IS NOT CURRENTLY CORRECTED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Navigation
Issued 20 January 1995 Resolved
VESSEL DOES NOT HAVE A CHART OF SAN JUAN HARBOR.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Documentation
Issued 20 January 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Lifesaving
Issued 20 January 1995 Resolved
49 C.F.R. 94.90_x001C_ VESSEL HAS 10(TEN) PARACHUTE SIGNALS, REQUIRED TO HAVE 12(TWELVE).
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Navigation
Issued 20 January 1995 Resolved
72 COLREGS_x001C_ NAVIGATIONAL LIGHT ARE INOPERABLE.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Navigation
Issued 20 January 1995 Resolved
SOLAS 74 CHAPTER V REGULATION 12(b)_x001C_ MAGNETIC STEERING COMPASS HAS NO ILLUMINATION.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Navigation
Issued 20 January 1995 Resolved
SOLAS 74 CHAPTER V REGULATION 12(b)_x001C_ VESSEL NEEDS A CURRENT DEVIATION TABLE.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Lifesaving
Issued 20 January 1995 Resolved
46 C.F.R. 94.60_x001C_ SHOW EVIDENCE THAT THE EPIRB HAS BEEN INSPECTED.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Navigation
Issued 20 January 1995 Resolved
46 C.F.R. 97.05-5(c)&(d) _x001C_ U.S. COAST PILOT AND LIGHT LIST ARE NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Electrical
Issued 20 January 1995 Resolved
46 C.F.R. 90.25_x001C_ BOW THRUSTER BATTERIES NEED TO BE IN A CASE TO KEEP FROM MOVING ABOUT.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Accommodation/Occupational Safety
Issued 20 January 1995 Resolved
VESSEL DOES NOT HAVE A SEWAGE HOLDING TANK.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Navigation
Issued 20 January 1995 Resolved
49 C.F.R. 97.05-5(g)_x001C_ VESSEL DOES NOT HAVE CURRENT TIDAL CURRENT TABLE._x001C_
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Documentation
Issued 20 January 1995 Resolved
VESSEL DOES NOT HAVE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 20 January 1995
Resolved 25 January 1995
Accommodation/Occupational Safety
Issued 14 May 1993 Resolved
1. Plastic materials requiring disposal were used aboard the vessel._x001C_ 2. There were no plastics in the vessel's trash for disposal ashore._x001C_ 3. There was no functional incinerator or any other disposal method aboard.4. Captian could not produce garbage pick up receipts._x001C_
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Documentation
Issued 30 April 1993 Resolved
1. Plastic materials requiring disposal were used aboard the vessel._x001C_ 2. There were no plastics in the vessel's trash for disposal ashore._x001C_ 3. There was no functional incinerator or any other disposal method aboard.4. Captain could not produce garbage pick up receipt.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Documentation
Issued 10 March 1993 Resolved
1. Plastic materials requiring disposal were used aboard the vessel._x001C_ 2. There were no waste plastics in the vessel's trash for disposal ashore._x001C_3. There was no functional incinerator or any other dispossal method aboard4. Captain could not produce garbage pick up receipt._x001C_
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Documentation
Issued 1 March 1993 Resolved
1. Plastic materials requiring disposal were used aboard the vessel. _x001C_ 2. There were no plastics in the vessel's trash for disposal ashore._x001C_ 3. There was no functional incinerator or any other disposal method aboard.4. Captain could not produce garbage pick up receipt.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.